Low-dose cone-beam CT via raw counts domain low-signal correction schemes: Performance assessment and task-based parameter optimization (Part II. Task-based parameter optimization).

Abstract:

PURPOSE:Different low-signal correction (LSC) methods have been shown to efficiently reduce noise streaks and noise level in CT to provide acceptable images at low-radiation dose levels. These methods usually result in CT images with highly shift-variant and anisotropic spatial resolution and noise, which makes the parameter optimization process highly nontrivial. The purpose of this work was to develop a local task-based parameter optimization framework for LSC methods. METHODS:Two well-known LSC methods, the adaptive trimmed mean (ATM) filter and the anisotropic diffusion (AD) filter, were used as examples to demonstrate how to use the task-based framework to optimize filter parameter selection. Two parameters, denoted by the set P, for each LSC method were included in the optimization problem. For the ATM filter, these parameters are the low- and high-signal threshold levels pl and ph ; for the AD filter, the parameters are the exponents δ and γ in the brightness gradient function. The detectability index d' under the non-prewhitening (NPW) mathematical observer model was selected as the metric for parameter optimization. The optimization problem was formulated as an unconstrained optimization problem that consisted of maximizing an objective function d'(P), where i and j correspond to the i-th imaging task and j-th spatial location, respectively. Since there is no explicit mathematical function to describe the dependence of d' on the set of parameters P for each LSC method, the optimization problem was solved via an experimentally measured d' map over a densely sampled parameter space. In this work, three high-contrast-high-frequency discrimination imaging tasks were defined to explore the parameter space of each of the LSC methods: a vertical bar pattern (task I), a horizontal bar pattern (task II), and a multidirectional feature (task III). Two spatial locations were considered for the analysis, a posterior region-of-interest (ROI) located within the noise streaks region and an anterior ROI, located further from the noise streaks region. Optimal results derived from the task-based detectability index metric were compared to other operating points in the parameter space with different noise and spatial resolution trade-offs. RESULTS:The optimal operating points determined through the d' metric depended on the interplay between the major spatial frequency components of each imaging task and the highly shift-variant and anisotropic noise and spatial resolution properties associated with each operating point in the LSC parameter space. This interplay influenced imaging performance the most when the major spatial frequency component of a given imaging task coincided with the direction of spatial resolution loss or with the dominant noise spatial frequency component; this was the case of imaging task II. The performance of imaging tasks I and III was influenced by this interplay in a smaller scale than imaging task II, since the major frequency component of task I was perpendicular to imaging task II, and because imaging task III did not have strong directional dependence. For both LSC methods, there was a strong dependence of the overall d' magnitude and shape of the contours on the spatial location within the phantom, particularly for imaging tasks II and III. The d' value obtained at the optimal operating point for each spatial location and imaging task was similar when comparing the LSC methods studied in this work. CONCLUSIONS:A local task-based detectability framework to optimize the selection of parameters for LSC methods was developed. The framework takes into account the potential shift-variant and anisotropic spatial resolution and noise properties to maximize the imaging performance of the CT system. Optimal parameters for a given LSC method depend strongly on the spatial location within the image object.

journal_name

Med Phys

journal_title

Medical physics

authors

Gomez-Cardona D,Hayes JW,Zhang R,Li K,Cruz-Bastida JP,Chen GH

doi

10.1002/mp.12855

subject

Has Abstract

pub_date

2018-05-01 00:00:00

pages

1957-1969

issue

5

eissn

0094-2405

issn

2473-4209

journal_volume

45

pub_type

杂志文章
  • Characterization of trabecular bone plate-rod microarchitecture using multirow detector CT and the tensor scale: Algorithms, validation, and applications to pilot human studies.

    abstract:PURPOSE:Osteoporosis is a common bone disease associated with increased risk of low-trauma fractures leading to substantial morbidity, mortality, and financial costs. Clinically, osteoporosis is defined by low bone mineral density (BMD); however, increasing evidence suggests that trabecular bone (TB) microarchitectural...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4928481

    authors: Saha PK,Liu Y,Chen C,Jin D,Letuchy EM,Xu Z,Amelon RE,Burns TL,Torner JC,Levy SM,Calarge CA

    更新日期:2015-09-01 00:00:00

  • Cascaded systems analysis of noise reduction algorithms in dual-energy imaging.

    abstract::An important aspect of dual-energy (DE) x-ray image decomposition is the incorporation of noise reduction techniques to mitigate the amplification of quantum noise. This article extends cascaded systems analysis of imaging performance to DE imaging systems incorporating linear noise reduction algorithms. A general ana...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2826556

    authors: Richard S,Siewerdsen JH

    更新日期:2008-02-01 00:00:00

  • Dose planning with comparison to in vivo dosimetry for epithermal neutron irradiation of the dog brain.

    abstract::Boron neutron capture therapy (BNCT) is an experimental type of radiotherapy, presently being used to treat glioblastoma and melanoma. To improve patient safety and to determine the radiobiological characteristics of the epithermal neutron beam of Finnish BNCT facility (FiR 1) dose-response studies were carried on the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1517048

    authors: Seppälä T,Auterinen I,Aschan C,Serén T,Benczik J,Snellman M,Huiskamp R,Ramadan UA,Kankaanranta L,Joensuu H,Savolainen S

    更新日期:2002-11-01 00:00:00

  • Technical Note: Immunohistochemical evaluation of mouse brain irradiation targeting accuracy with 3D-printed immobilization device.

    abstract:PURPOSE:Small animal immobilization devices facilitate positioning of animals for reproducible imaging and accurate focal radiation therapy. In this study, the authors demonstrate the use of three-dimensional (3D) printing technology to fabricate a custom-designed mouse head restraint. The authors evaluate the accuracy...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4933200

    authors: Zarghami N,Jensen MD,Talluri S,Foster PJ,Chambers AF,Dick FA,Wong E

    更新日期:2015-11-01 00:00:00

  • Sci-Thur PM: YIS - 08: The effect of copper conversion plates on low-Z target image quality.

    abstract::Current generation electronic portal imaging devices (EPID) contain a 1.0 mm copper conversion plate to increase detection efficiency of a therapeutic megavoltage spectrum. When using these EPIDs for low-Z target imaging, the conversion plate largely attenuates the large populations of diagnostic energy photons, there...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740105

    authors: Parsons D,Robar JL

    更新日期:2012-07-01 00:00:00

  • Strategies for scatter correction in dual source CT.

    abstract:PURPOSE:Dual source CT (DSCT) systems utilize two measurement systems (A) and (B) offset by about 90 degrees. A special challenge in DSCT is cross-scattered radiation, i.e., scattered radiation from x-ray tube (B) detected in detector (A) and vice versa. Cross-scattered radiation can produce artifacts and degrade the c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3504606

    authors: Petersilka M,Stierstorfer K,Bruder H,Flohr T

    更新日期:2010-11-01 00:00:00

  • A voxel-based multiscale model to simulate the radiation response of hypoxic tumors.

    abstract:PURPOSE:In radiotherapy, it is important to predict the response of tumors to irradiation prior to the treatment. This is especially important for hypoxic tumors, which are known to be highly radioresistant. Mathematical modeling based on the dose distribution, biological parameters, and medical images may help to impr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4903298

    authors: Espinoza I,Peschke P,Karger CP

    更新日期:2015-01-01 00:00:00

  • Determination of the reference air kerma rate for 192Ir brachytherapy sources and the related uncertainty.

    abstract::Different methods exist to determine the air kerma calibration factor of an ionization chamber for the spectrum of a 192Ir high-dose-rate (HDR) or pulsed-dose-rate (PDR) source. An analysis of two methods to obtain such a calibration factor was performed: (i) the method recommended by [Goetsch et al., Med. Phys. 18, 4...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1791352

    authors: van Dijk E,Kolkman-Deurloo IK,Damen PM

    更新日期:2004-10-01 00:00:00

  • Unwanted radiation produced by leakage neutrons from medical electron accelerators.

    abstract::Monte Carlo calculations have been made to determine the energy delivered to a phantom by neutrons escaping from the head of a Varian Clinac 35 medical accelerator at an SSD of 1 m. The energy was sorted into two regions: inside and outside a volume defined by a circular beam of area 100 and 600 cm2. For the two beam ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595067

    authors: Ing H,Shore RA

    更新日期:1982-01-01 00:00:00

  • Direct aperture deformation: an interfraction image guidance strategy.

    abstract::A new scheme, called direct aperture deformation (DAD), for online correction of interfraction geometric uncertainties under volumetric imaging guidance is presented. Using deformable image registration, the three-dimensional geometric transformation matrix can be derived that associates the planning image set and the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2374675

    authors: Feng Y,Castro-Pareja C,Shekhar R,Yu C

    更新日期:2006-12-01 00:00:00

  • Dose distributions of a proton beam for eye tumor therapy: hybrid pencil-beam ray-tracing calculations.

    abstract::For the case of eye tumor therapy with protons, improvements are introduced compared to the standard dose calculation which implies straight-line optics and the constant-density assumption for the eye and its surrounding. The progress consists of (i) taking account of the lateral scattering of the protons in tissue by...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2168067

    authors: Rethfeldt C,Fuchs H,Gardey KU

    更新日期:2006-03-01 00:00:00

  • Optimized radial and angular positions in Monte Carlo modeling.

    abstract::In Monte Carlo simulations of light transport in tissues, a grid system is set up to score physical quantities. This study of cylindrically symmetrical problems found that the optimized radial and angular positions for the averaged physical quantities in each grid element are off-center. The error of the extrapolated ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597351

    authors: Wang L,Jacques SL

    更新日期:1994-07-01 00:00:00

  • Noise, resolution, and sensitivity considerations in the design of a single-slice emission-transmission computed tomographic system.

    abstract::A prototype Emission-Transmission Computed Tomography (ETCT) system is being developed that will acquire single-slice x-ray transmission CT images simultaneously with single photon emission computed tomography (SPECT) images. This system will permit the correlation of anatomical information from x-ray CT with function...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596643

    authors: Liew SC,Hasegawa BH

    更新日期:1991-09-01 00:00:00

  • Subvoxel precise skeletons of volumetric data based on fast marching methods.

    abstract::The accurate calculation of the skeleton of an object is a problem not satisfactorily solved by existing approaches. Most algorithms require a significant amount of user interaction and use a voxel grid to compute discrete and often coarse approximations of this representation of the data. We present a novel, automati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2409238

    authors: Van Uitert R,Bitter I

    更新日期:2007-02-01 00:00:00

  • Development of a silicon diode detector for skin dosimetry in radiotherapy.

    abstract:PURPOSE:The aim of in vivo skin dosimetry was to measure the absorbed dose to the skin during radiotherapy, when treatment planning calculations cannot be relied on. It is of particularly importance in hypo-fractionated stereotactic modalities, where excessive dose can lead to severe skin toxicity. Currently, commercia...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12469

    authors: Vicoroski N,Espinoza A,Duncan M,Oborn BM,Carolan M,Metcalfe P,Menichelli D,Perevertaylo VL,Lerch MLF,Rosenfeld AB,Petasecca M

    更新日期:2017-10-01 00:00:00

  • The influence of phantom size on output, peak scatter factor, and percentage depth dose in large-field photon irradiation.

    abstract::Machine outputs, peak scatter factors, and central axis percentage depth dose distributions were measured for various phantom sizes in large radiation fields produced at extended distances by cobalt, 6-MV, and 10-MV photon beams. The results can be applied to practical total body irradiation procedures which usually i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595686

    authors: Podgorsak EB,Pla C,Evans MD,Pla M

    更新日期:1985-09-01 00:00:00

  • Validation for 2D/3D registration. I: A new gold standard data set.

    abstract:PURPOSE:In this article, the authors propose a new gold standard data set for the validation of two-dimensional/three-dimensional (2D/3D) and 3D/3D image registration algorithms. METHODS:A gold standard data set was produced using a fresh cadaver pig head with attached fiducial markers. The authors used several imagin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3553402

    authors: Pawiro SA,Markelj P,Pernus F,Gendrin C,Figl M,Weber C,Kainberger F,Nöbauer-Huhmann I,Bergmeister H,Stock M,Georg D,Bergmann H,Birkfellner W

    更新日期:2011-03-01 00:00:00

  • SU-E-T-217: Automated Data Mining of Lung SBRT Cases for Predicting Dosimetric Indices in Prospective Plans.

    abstract:PURPOSE:To develop an automated technique for evaluating lung stereotactic body radiotherapy (SBRT) plan quality and predicting achievable lung dose constraints. METHODS:We examined the workflow scripting capabilities of a radiation oncology software package (MIM Software Inc) for automatically generating mean dose gr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735279

    authors: Atwood T,Xing L,Hristov D

    更新日期:2012-06-01 00:00:00

  • Quantitative assessment of bone mineral by photon scattering: accuracy and precision considerations.

    abstract::A method to determine the bone mineral density of the calcaneum has been reported earlier by our laboratory. In this method, the calcaneum is irradiated by a 60-keV photon beam from 241Am source and both the coherent and Compton scattered photons are detected by a high-purity Ge detector. The bone mineral density is d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595669

    authors: Shukla SS,Karellas A,Leichter I,Craven JD,Greenfield MA

    更新日期:1985-07-01 00:00:00

  • Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology.

    abstract::The performance of an indirect-detection, active matrix flat-panel imager (FPI) at diagnostic energies is reported in terms of measured and theoretical signal size, noise power spectrum (NPS), and detective quantum efficiency (DQE). Based upon a 1536 x 1920 pixel, 127 microns pitch array of a-Si:H thin-film transistor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598243

    authors: Siewerdsen JH,Antonuk LE,el-Mohri Y,Yorkston J,Huang W,Cunningham IA

    更新日期:1998-05-01 00:00:00

  • Monte Carlo dosimetry for 103Pd, 125I, and 131Cs ocular brachytherapy with various plaque models using an eye phantom.

    abstract:PURPOSE:To investigate dosimetry for ocular brachytherapy for a range of eye plaque models containing(103)Pd, (125)I, or (131)Cs seeds with model-based dose calculations. METHODS:Five representative plaque models are developed based on a literature review and are compared to the standardized COMS plaque, including pla...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4864474

    authors: Lesperance M,Martinov M,Thomson RM

    更新日期:2014-03-01 00:00:00

  • Monte Carlo dosimetry for I125 and Pd103 eye plaque brachytherapy.

    abstract::A Monte Carlo study of dosimetry for eye plaque brachytherapy is performed. BrachyDose, an EGSnrc user code which makes use of Yegin's multi-geometry package, is used to fully model I125 (model 6711) and Pd103 (model 200) brachytherapy seeds and the standardized plaques of the Collaborative Ocular Melanoma Study (COMS...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3002412

    authors: Thomson RM,Taylor REP,Rogers DWO

    更新日期:2008-12-01 00:00:00

  • Evaluation of a compact multicontrast and multiresolution X-ray phase contrast edge illumination system for small animal imaging.

    abstract:PURPOSE:In this work the performance of a compact multiresolution and multicontrast x-ray phase system based on edge illumination is investigated. It has been designed for small animal imaging and with a limited footprint for ease of deployment in laboratories. METHODS:The presented edge illumination system is based o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14553

    authors: Massimi L,Meganck JA,Towns R,Olivo A,Endrizzi M

    更新日期:2020-10-27 00:00:00

  • Traceable micro-CT scaling accuracy phantom for applications requiring exact measurement of distances or volumes.

    abstract:PURPOSE:Volumetric x-ray microcomputed tomography (CT) can be employed in a variety of quantitative research applications such as image-guided interventions or characterization of medical devices. To ensure the highest geometric fidelity of images for these applications, a phantom and image processing algorithm have be...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4752083

    authors: Waring CS,Bax JS,Samarabandu A,Holdsworth DW,Fenster A,Lacefield JC

    更新日期:2012-10-01 00:00:00

  • SU-E-J-170: Clinical Evaluation of Positioning Accuracy of Two Immobilization Devices for Stereotactic Body Radiotherapy Using Cone Beam CT.

    abstract:PURPOSE:To evaluate the patient positioning accuracy and reproducibility of two commercially available immobilization systems for Stereotactic Body Radiotherapy (SBRT) treatment. METHODS:Forty one patients with lung (n=21) or liver (n=20) malignancies were assigned to one of the two immobilization devices: Elekta ster...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735009

    authors: Cao M,Cao N,Cardenes H,Fakiris A,Desrosiers C,Das I

    更新日期:2012-06-01 00:00:00

  • A Monte Carlo comparison of the response of the PTW-diamond and the TL-diamond detectors in megavoltage photon beams.

    abstract::A detailed Monte Carlo study of the PTW-diamond solid state detector response in megavoltage photon beams (60Co gamma rays to 25 MV x rays) has been performed with the EGS4 Monte Carlo Code. The sensitive volume of the diamond detector is a disk of diameter 4.4 mm and thickness 0.40 mm. The phantom material was water ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598771

    authors: Mobit PN,Sandison GA

    更新日期:1999-11-01 00:00:00

  • Toward the combined optimization of dynamic axes (CODA) for stereotactic radiotherapy and radiosurgery using fixed couch trajectories.

    abstract:PURPOSE:To develop a novel system for patient-specific combined optimization of couch, collimator, and gantry angles for use in volumetric modulated arc therapy (VMAT) treatment planning. The system was designed to produce highly compact dose distributions by extensively sampling the 4π space. Automated fixed couch tra...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13887

    authors: MacDonald RL,Syme A,Little B,Ward L,Thomas CG

    更新日期:2020-02-01 00:00:00

  • Selecting registration schemes in case of interstitial lung disease follow-up in CT.

    abstract:PURPOSE:Primary goal of this study is to select optimal registration schemes in the framework of interstitial lung disease (ILD) follow-up analysis in CT. METHODS:A set of 128 multiresolution schemes composed of multiresolution nonrigid and combinations of rigid and nonrigid registration schemes are evaluated, utilizi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4923170

    authors: Vlachopoulos G,Korfiatis P,Skiadopoulos S,Kazantzi A,Kalogeropoulou C,Pratikakis I,Costaridou L

    更新日期:2015-08-01 00:00:00

  • Transcranial phase aberration correction using beam simulations and MR-ARFI.

    abstract:PURPOSE:Transcranial magnetic resonance-guided focused ultrasound surgery is a noninvasive technique for causing selective tissue necrosis. Variations in density, thickness, and shape of the skull cause aberrations in the location and shape of the focal zone. In this paper, the authors propose a hybrid simulation-MR-AR...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4865778

    authors: Vyas U,Kaye E,Pauly KB

    更新日期:2014-03-01 00:00:00

  • Measurement of primary bremsstrahlung spectrum from an 8-MeV linear accelerator.

    abstract::The bremsstrahlung spectrum from an 8-MeV linear accelerator has been measured using a NaI(T1) spectrometer system. The spectrum shows a low-energy cutoff at 0.4 MeV and the maximum photon energy to be approximately 6% greater than the nominal energy. The maximum emission of energy fluence was 1.6 and 1.8 MeV for meas...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594221

    authors: Levy LB,Waggener RG,Wright AE

    更新日期:1976-05-01 00:00:00