Noise, resolution, and sensitivity considerations in the design of a single-slice emission-transmission computed tomographic system.

Abstract:

:A prototype Emission-Transmission Computed Tomography (ETCT) system is being developed that will acquire single-slice x-ray transmission CT images simultaneously with single photon emission computed tomography (SPECT) images. This system will permit the correlation of anatomical information from x-ray CT with functional information from SPECT images. The patient-specific attenuation map derived from the x-ray CT images can be used to perform attenuation correction of the SPECT images, so that accurate quantitative information can be obtained. The fan-beam scanning geometry and the use of a segmented HPGe detector array impose special constraints on the design of the collimator for the system. Based on a signal detection model, an efficiency-resolution figure of merit (ERFM) as a function of the collimator geometric efficiency, system resolution width, and object diameter is defined. The ERFM is proportional to the square of the detection signal-to-noise ratio. The collimator design parameters can then be optimized by optimizing the ERFM for an anticipated object diameter. The collimator point-spread function, geometric efficiency, and resolution are calculated. The collimator optimized for the detection of a 1-cm object will have a single-slice point source efficiency of 1.2 X 10(-4), and a FWHM of 6.5 mm at the center of the reconstruction circle, at 12 cm from the collimator face. The minimum object contrast which will give a detection SNR of 5 is 74%, for a total accumulated count per slice of 2 X 10(6).

journal_name

Med Phys

journal_title

Medical physics

authors

Liew SC,Hasegawa BH

doi

10.1118/1.596643

subject

Has Abstract

pub_date

1991-09-01 00:00:00

pages

1002-15

issue

5

eissn

0094-2405

issn

2473-4209

journal_volume

18

pub_type

杂志文章
  • An algorithm for fast beam angle selection in intensity modulated radiotherapy.

    abstract:PURPOSE:This article aims to introduce a novel algorithm for fast beam angle selection in intensity modulated radiotherapy (IMRT). METHODS:The algorithm models the optimization problem as a beam angle ranking problem and chooses suitable beam angles according to their rank. A new parameter called "beam intensity profi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3517866

    authors: Vaitheeswaran R,Narayanan VK,Bhangle JR,Nirhali A,Kumar N,Basu S,Maiya V

    更新日期:2010-12-01 00:00:00

  • An experimentally validated couch and MLC tracking simulator used to investigate hybrid couch-MLC tracking.

    abstract:PURPOSE/OBJECTIVE:Couch and MLC tracking are two novel techniques to mitigate intrafractional tumor motion on a conventional linear accelerator, but both techniques still have residual dosimetric errors. Here, we first propose and experimentally validate a software tool to simulate couch and MLC tracking, and then use ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12104

    authors: Toftegaard J,Hansen R,Ravkilde T,Macek K,Poulsen PR

    更新日期:2017-03-01 00:00:00

  • A convolution method for constructing primary beam profiles in the presence of beam modifiers.

    abstract::Empirical functions that describe primary beam profiles for radiotherapy treatment planning systems generally account for finite source size only on beams unmodified by blocks, wedges, or compensating filters. To incorporate the effects of extended sources on such modified beams and to treat the effect of an extended ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596222

    authors: Starkschall G

    更新日期:1988-09-01 00:00:00

  • Soft-tissue detectability in cone-beam CT: evaluation by 2AFC tests in relation to physical performance metrics.

    abstract::Soft-tissue detectability in cone-beam computed tomography (CBCT) was evaluated via two-alternative forced-choice (2AFC) tests. Investigations included the dependence of detectability on radiation dose, the influence of the asymmetric three-dimensional (3D) noise-power spectrum (NPS) in axial and sagittal or coronal p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2790586

    authors: Tward DJ,Siewerdsen JH,Daly MJ,Richard S,Moseley DJ,Jaffray DA,Paul NS

    更新日期:2007-11-01 00:00:00

  • A novel PET tumor delineation method based on adaptive region-growing and dual-front active contours.

    abstract::To more accurately and precisely delineate a tumor in a 3D PET image, we proposed a novel, semi-automatic, two-stage method by utilizing an adaptive region-growing algorithm and a dual-front active contour model. First, a rough region of interest (ROI) is manually drawn by a radiation oncologist that encloses a tumor....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2956713

    authors: Li H,Thorstad WL,Biehl KJ,Laforest R,Su Y,Shoghi KI,Donnelly ED,Low DA,Lu W

    更新日期:2008-08-01 00:00:00

  • A localization algorithm and error analysis for stereo x-ray image guidance.

    abstract::Stereo x-ray radiography attracts increasing attention in major clinical applications. The purpose of this paper is to analyze the 3D localization error for breast biopsy procedures and provide guidelines for improving its accuracy. Our prototype is a CCD based digital stereo x-ray imaging system. The mathematical mod...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598953

    authors: Jiang H,Liu H,Wang G,Chen W,Fajardo LL

    更新日期:2000-05-01 00:00:00

  • A moving slanted-edge method to measure the temporal modulation transfer function of fluoroscopic systems.

    abstract::Lag in fluoroscopic systems introduces a frame-averaging effect that reduces measurements of image noise and incorrectly inflates measurements of the detective quantum efficiency (DQE). A correction can be implemented based on measurements of the temporal modulation transfer function (MTF). We introduce a method of me...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2919724

    authors: Friedman SN,Cunningham IA

    更新日期:2008-06-01 00:00:00

  • SU-E-T-382: An Analysis of VMAT Monthly Quality Assurance.

    abstract:PURPOSE:The purpose of this study is to quantify the change in monthly VMAT quality assurance (QA) and determine the tests to maintain consistent delivery with a baseline. METHODS:VMAT monthly QA has been performed for over 14 months on two Elekta Synergy LINACs. A baseline was established at acceptance and the monthl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735470

    authors: Stenbeck J,Oves S,Gebreamlak W,Alkhatib H

    更新日期:2012-06-01 00:00:00

  • A framework for defining FLASH dose rate for pencil beam scanning.

    abstract:PURPOSE:To develop a method of (a) calculating the dose rate of voxels within a proton field delivered using pencil beam scanning (PBS), and (b) reporting a representative dose rate for the PBS treatment field that enables correspondence between multiple treatment modalities. This method takes into account the unique s...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14456

    authors: Folkerts MM,Abel E,Busold S,Perez JR,Krishnamurthi V,Ling CC

    更新日期:2020-12-01 00:00:00

  • A method to compare supra-pubic ultrasound and CT images of the prostate: technique and early clinical results.

    abstract::We describe a unique method that allows the comparison of spatially registered ultrasound (SRUS) images and computed tomography-derived contours (CTDCs) that were acquired with a minimal time lapse. As such, we have a tool that will provide validation of the spatial accuracy of the US system and that will allow compar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1644515

    authors: Molloy JA,Srivastava S,Schneider BF

    更新日期:2004-03-01 00:00:00

  • Analytical probabilistic modeling of dose-volume histograms.

    abstract:PURPOSE:Radiotherapy, especially with charged particles, is sensitive to executional and preparational uncertainties that propagate to uncertainty in dose and plan quality indicators, for example, dose-volume histograms (DVHs). Current approaches to quantify and mitigate such uncertainties rely on explicitly computed e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14414

    authors: Wahl N,Hennig P,Wieser HP,Bangert M

    更新日期:2020-10-01 00:00:00

  • Correcting magnetic resonance k-space data for in-plane motion using an optical position tracking system.

    abstract:PURPOSE:Motion is a major confound of image quality in MRI. A method of retrospectively correcting the effects of rotations and translations on the acquired k-space data is presented. METHODS:In two phantom experiments of well-controlled translation and rotation, two MRI-compatible infrared cameras recorded motion dat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3254189

    authors: Marxen M,Marmurek J,Baker N,Graham SJ

    更新日期:2009-12-01 00:00:00

  • Vision 20/20: Mammographic breast density and its clinical applications.

    abstract::Breast density is a strong predictor of the failure of mammography screening to detect breast cancer and is a strong predictor of the risk of developing breast cancer. The many imaging options that are now available for imaging dense breasts show great promise, but there is still the question of determining which wome...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.4935141

    authors: Ng KH,Lau S

    更新日期:2015-12-01 00:00:00

  • An observer study comparing spot imaging regions selected by radiologists and a computer for an automated stereo spot mammography technique.

    abstract::We are developing an automated stereo spot mammography technique for improved imaging of suspicious dense regions within digital mammograms. The technique entails the acquisition of a full-field digital mammogram, automated detection of a suspicious dense region within that mammogram by a computer aided detection (CAD...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1737492

    authors: Goodsitt MM,Chan HP,Lydick JT,Gandra CR,Chen NG,Helvie MA,Bailey JE,Roubidoux MA,Paramagul C,Blane CE,Sahiner B,Petrick NA

    更新日期:2004-06-01 00:00:00

  • WE-D-213AB-03: Preparing for the ABR Diagnostic Medical Physics Board Exams - Oral Exam.

    abstract::Part III (oral exam) is the final part of ABR board exam for Diagnostic Medical Physics. In this exam, each of five oral examiners questions the candidate in each of five question categories. Oral exam has unique challenges to the candidate compared with the written exams. The candidate is expected to have not only ad...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736136

    authors: Leng S,Chen L,Shu Y,McCollough C

    更新日期:2012-06-01 00:00:00

  • X-ray imaging with amorphous selenium: X-ray to charge conversion gain and avalanche multiplication gain.

    abstract::Fluoroscopy is a low dose imaging technique. As such, a very sensitive detector is required to create images of good quality. Present day flat panel active matrix read out systems introduce an amount of noise that inhibits present direct and indirect methods from producing optimal quality images at fluoroscopic exposu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1513157

    authors: Hunt DC,Kirby SS,Rowlands JA

    更新日期:2002-11-01 00:00:00

  • Development of a novel high quantum efficiency MV x-ray detector for image-guided radiotherapy: A feasibility study.

    abstract:PURPOSE:To develop a new scintillating fiber-based electronic portal imaging device (EPID) with a high quantum efficiency (QE) while preserving an adequate spatial resolution. METHODS:Two prototypes were built: one with a single pixel readout and the other with an active matrix flat-panel imager (AMFPI) for readout. T...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13900

    authors: Liu J,Xu Y,Teymurazyan A,Papandreou Z,Pang G

    更新日期:2020-01-01 00:00:00

  • Development and clinical implementation of semi-automated treatment planning including 3D printable applicator holders in complex skin brachytherapy.

    abstract:PURPOSE:High-dose-rate brachytherapy (HDR-BT) is a treatment option for malignant skin diseases compared to external beam radiation therapy, HDR-BT provides improved target coverage, better organ sparing, and has comparable treatment times. This is especially true for large clinical targets with complex topologies. To ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13975

    authors: Guthier CV,Devlin PM,Harris TC,O'Farrell DA,Cormack RA,Buzurovic I

    更新日期:2020-03-01 00:00:00

  • Anthropomorphic 1H MRS head phantom.

    abstract::An anthropomorphic 1H MRS head phantom has been developed which mimics the in vivo structure, metabolite concentrations, and relaxation times (for both water and metabolites) of human brain tissue. Different brain regions and two tumor types, fluid-containing ventricles, and air-filled sinus, and subcutaneous fat are ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598306

    authors: Rice JR,Milbrandt RH,Madsen EL,Frank GR,Boote EJ,Blechinger JC

    更新日期:1998-07-01 00:00:00

  • Design for an accelerator-based orthogonal epithermal neutron beam for boron neutron capture therapy.

    abstract::This paper is concerned with the proposed Birmingham accelerator-based epithermal neutron beam for boron neutron capture therapy (BNCT). In particular, the option of producing a therapy beam at an orthogonal direction to the incoming protons is considered. Monte Carlo radiation transport simulations, both with and wit...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598479

    authors: Allen DA,Beynon TD,Green S

    更新日期:1999-01-01 00:00:00

  • Task-based assessment of breast tomosynthesis: effect of acquisition parameters and quantum noise.

    abstract:PURPOSE:Tomosynthesis is a promising modality for breast imaging. The appearance of the tomosynthesis reconstructed image is greatly affected by the choice of acquisition and reconstruction parameters. The purpose of this study was to investigate the limitations of tomosynthesis breast imaging due to scan parameters an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3357288

    authors: Reiser I,Nishikawa RM

    更新日期:2010-04-01 00:00:00

  • Reconstruction of 4-MV bremsstrahlung spectra from measured transmission data.

    abstract::Transmission data for 4-MV bremsstrahlung beams have been measured with a combination of lead and aluminum attenuators. From these data, the original energy spectra have been reconstructed using an iterative least-squares technique, previously evaluated by simulation studies. The spectra on the central axis for three ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595356

    authors: Huang PH,Kase KR,Bjärngard BE

    更新日期:1983-11-01 00:00:00

  • Kilovoltage stereotactic radiosurgery for age-related macular degeneration: assessment of optic nerve dose and patient effective dose.

    abstract::Age-related macular degeneration (AMD) is a leading cause for vision loss for people over the age of 65 in the United States and a major health problem worldwide. Research for new treatments of the wet form of the disease using kilovoltage stereotactic radiosurgery is currently underway at Oraya Therapeutics, Inc. In ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3168554

    authors: Hanlon J,Lee C,Chell E,Gertner M,Hansen S,Howell RW,Bolch WE

    更新日期:2009-08-01 00:00:00

  • Dosimetric verification of helical tomotherapy for total scalp irradiation.

    abstract::Total scalp irradiation is a treatment technique used for a variety of superficial malignancies. Helical tomotherapy is an effective technique used for total scalp irradiation. Recent published work has shown the TomoTherapy planning system to overestimate the superficial dose. In this study, the superficial doses for...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2996288

    authors: Hardcastle N,Soisson E,Metcalfe P,Rosenfeld AB,Tome WA

    更新日期:2008-11-01 00:00:00

  • Feasibility of estimating volumetric breast density from mammographic x-ray spectra using a cadmium telluride photon-counting detector.

    abstract:PURPOSE:Mammographic density of glandular breast tissue has a masking effect that can reduce lesion detection accuracy and is also a strong risk factor for breast cancer. Therefore, accurate quantitative estimation of breast density is clinically important. In this study, we investigate experimentally the feasibility o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13031

    authors: Ghammraoui B,Badal A,Glick SJ

    更新日期:2018-06-03 00:00:00

  • A novel computer-aided lung nodule detection system for CT images.

    abstract:PURPOSE:The paper presents a complete computer-aided detection (CAD) system for the detection of lung nodules in computed tomography images. A new mixed feature selection and classification methodology is applied for the first time on a difficult medical image analysis problem. METHODS:The CAD system was trained and t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3633941

    authors: Tan M,Deklerck R,Jansen B,Bister M,Cornelis J

    更新日期:2011-10-01 00:00:00

  • Patient motion effects on the quantification of regional myocardial blood flow with dynamic PET imaging.

    abstract:PURPOSE:Patient motion is a common problem during dynamic positron emission tomography (PET) scans for quantification of myocardial blood flow (MBF). The purpose of this study was to quantify the prevalence of body motion in a clinical setting and evaluate with realistic phantoms the effects of motion on blood flow qua...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4943565

    authors: Hunter CR,Klein R,Beanlands RS,deKemp RA

    更新日期:2016-04-01 00:00:00

  • Assessing radiation and light field congruence with a video based electronic portal imaging device.

    abstract::Projected light fields are used on treatment simulators and teletherapy treatment units to delineate the size and position of the radiation beam. Any discrepancy between these fields will lead to a systematic field placement error, with possibly serious implications with regard to the accuracy of the delivered dose di...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597867

    authors: Luchka K,Chen D,Shalev S,Gluhchev G,Rajapakshe R

    更新日期:1996-07-01 00:00:00

  • Measurement of dose distributions using film in therapeutic electron beams.

    abstract::The feasibility of using film dosimetry data as the input data for patient treatment planning was evaluated. The central-axis depth dose and the off-axis ratios obtained from film measurements in a solid phantom were compared with those of ion-chamber measurements in water. Two techniques were used to generate isodose...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596409

    authors: Shiu AS,Otte VA,Hogstrom KR

    更新日期:1989-11-01 00:00:00

  • Rigid 2D/3D slice-to-volume registration and its application on fluoroscopic CT images.

    abstract::Registration of single slices from FluoroCT, CineMR, or interventional magnetic resonance imaging to three dimensional (3D) volumes is a special aspect of the two-dimensional (2D)/3D registration problem. Rather than digitally rendered radiographs (DRR), single 2D slice images obtained during interventional procedures...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2401661

    authors: Birkfellner W,Figl M,Kettenbach J,Hummel J,Homolka P,Schernthaner R,Nau T,Bergmann H

    更新日期:2007-01-01 00:00:00