A novel computer-aided lung nodule detection system for CT images.

Abstract:

PURPOSE:The paper presents a complete computer-aided detection (CAD) system for the detection of lung nodules in computed tomography images. A new mixed feature selection and classification methodology is applied for the first time on a difficult medical image analysis problem. METHODS:The CAD system was trained and tested on images from the publicly available Lung Image Database Consortium (LIDC) on the National Cancer Institute website. The detection stage of the system consists of a nodule segmentation method based on nodule and vessel enhancement filters and a computed divergence feature to locate the centers of the nodule clusters. In the subsequent classification stage, invariant features, defined on a gauge coordinates system, are used to differentiate between real nodules and some forms of blood vessels that are easily generating false positive detections. The performance of the novel feature-selective classifier based on genetic algorithms and artificial neural networks (ANNs) is compared with that of two other established classifiers, namely, support vector machines (SVMs) and fixed-topology neural networks. A set of 235 randomly selected cases from the LIDC database was used to train the CAD system. The system has been tested on 125 independent cases from the LIDC database. RESULTS:The overall performance of the fixed-topology ANN classifier slightly exceeds that of the other classifiers, provided the number of internal ANN nodes is chosen well. Making educated guesses about the number of internal ANN nodes is not needed in the new feature-selective classifier, and therefore this classifier remains interesting due to its flexibility and adaptability to the complexity of the classification problem to be solved. Our fixed-topology ANN classifier with 11 hidden nodes reaches a detection sensitivity of 87.5% with an average of four false positives per scan, for nodules with diameter greater than or equal to 3 mm. Analysis of the false positive items reveals that a considerable proportion (18%) of them are smaller nodules, less than 3 mm in diameter. CONCLUSIONS:A complete CAD system incorporating novel features is presented, and its performance with three separate classifiers is compared and analyzed. The overall performance of our CAD system equipped with any of the three classifiers is well with respect to other methods described in literature.

journal_name

Med Phys

journal_title

Medical physics

authors

Tan M,Deklerck R,Jansen B,Bister M,Cornelis J

doi

10.1118/1.3633941

subject

Has Abstract

pub_date

2011-10-01 00:00:00

pages

5630-45

issue

10

eissn

0094-2405

issn

2473-4209

journal_volume

38

pub_type

杂志文章
  • Gafchromic EBT2 film dosimetry in reflection mode with a novel plan-based calibration method.

    abstract:PURPOSE:A dosimetric system formed by Gafchromic EBT2 radiochromic film and Epson Expression 10000XL flatbed scanner was commissioned for dosimetry. In this paper, several open questions concerning the commissioning of radiochromic films for dosimetry were addressed: (a) is it possible to employ this dosimetric system ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4772075

    authors: Mendez I,Hartman V,Hudej R,Strojnik A,Casar B

    更新日期:2013-01-01 00:00:00

  • Sci-Fri PM: Planning-04: Dose escalation study using anatomy-based aperture IMRT and SPECT perfusion images for lung cancer.

    abstract::In the case of non-small cell lung cancer, doses typically prescribed (60-66 Gy) are not sufficient to ensure a satisfactory tumor control probability. Dose escalation needs to be realized, but dose to organs at risk (OARs) must be kept under widely accepted clinical thresholds. Also, lung functionality is not homogen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965976

    authors: St-Hilaire J,Lavoie C,Beaulieu F,Dagnault A,Morin F,Gingras L,Tremblay D,Beaulieu L

    更新日期:2008-07-01 00:00:00

  • Registration of central paths and colonic polyps between supine and prone scans in computed tomography colonography: pilot study.

    abstract::Computed tomography colonography (CTC) is a minimally invasive method that allows the evaluation of the colon wall from CT sections of the abdomen/pelvis. The primary goal of CTC is to detect colonic polyps, precursors to colorectal cancer. Because imperfect cleansing and distension can cause portions of the colon wal...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1796171

    authors: Li P,Napel S,Acar B,Paik DS,Jeffrey RB Jr,Beaulieu CF

    更新日期:2004-10-01 00:00:00

  • The application of sparse arrays in high frequency transcranial focused ultrasound therapy: a simulation study.

    abstract:PURPOSE:Transcranial focused ultrasound is an emerging therapeutic modality that can be used to perform noninvasive neurosurgical procedures. The current clinical transcranial phased array operates at 650 kHz, however the development of a higher frequency array would enable more precision, while reducing the risk of st...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4829510

    authors: Pajek D,Hynynen K

    更新日期:2013-12-01 00:00:00

  • Diamond detector versus silicon diode and ion chamber in photon beams of different energy and field size.

    abstract::The aim of this work was to test the suitability of a PTW diamond detector for nonreference condition dosimetry in photon beams of different energy (6 and 25 MV) and field size (from 2.6 cm x 2.6 cm to 10 cm x 10 cm). Diamond behavior was compared to that of a Scanditronix p-type silicon diode and a Scanditronix RK io...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1591431

    authors: Bucciolini M,Buonamici FB,Mazzocchi S,De Angelis C,Onori S,Cirrone GA

    更新日期:2003-08-01 00:00:00

  • A novel 3D printing method for accurate anatomy replication in patient-specific phantoms.

    abstract:PURPOSE:A novel 3D printing method has been developed, which employs human CT images to construct patient specific phantoms by controlling the filament extrusion rate. METHODS:An in-house software was developed comprising pixel-by-pixel (PbP) reading of the Hounsfield Units (HU) values in the original patient DICOM im...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13154

    authors: Okkalidis N

    更新日期:2018-10-01 00:00:00

  • Energy dependent calibration of XR-QA2 radiochromic film with monochromatic and polychromatic x-ray beams.

    abstract:PURPOSE:This work investigates the energy response and dose-response curve determinations for XR-QA2 radiochromic film dosimetry system used for synchrotron radiation work and for quality assurance in diagnostic radiology, in the range of effective energies 18-46.5 keV. METHODS:Pieces of XR-QA2 films were irradiated, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4939063

    authors: Di Lillo F,Mettivier G,Sarno A,Tromba G,Tomic N,Devic S,Russo P

    更新日期:2016-01-01 00:00:00

  • Measurement of neutron ambient dose equivalent in passive carbon-ion and proton radiotherapies.

    abstract::Secondary neutron ambient dose equivalents per the treatment absorbed dose in passive carbon-ion and proton radiotherapies were measured using a rem meter, WENDI-II at two carbon-ion radiotherapy facilities and four proton radiotherapy facilities in Japan. Our measured results showed that (1) neutron ambient dose equi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2989019

    authors: Yonai S,Matsufuji N,Kanai T,Matsui Y,Matsushita K,Yamashita H,Numano M,Sakae T,Terunuma T,Nishio T,Kohno R,Akagi T

    更新日期:2008-11-01 00:00:00

  • Lag measurement in an a-Se active matrix flat-panel imager.

    abstract::Lag and residual contrast have been quantified in an amorphous selenium (a-Se) active-matrix flat-panel imager (AMFPI) as a function of frame time, kilovoltage (kV) and megavoltage (MV) x-ray photon energies and amount of radiation incident on the detector. The AMFPI contains a 200 microm thick a-Se layer deposited on...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1713298

    authors: Schroeder C,Stanescu T,Rathee S,Fallone BG

    更新日期:2004-05-01 00:00:00

  • An accelerator based system for in vivo neutron activation analysis measurements of manganese in human hand bones.

    abstract::Manganese (Mn) is an essential nutrient for growth and development. Unfortunately, overexposure can lead to neurological damage, which is manifested as a movement disorder marked by tremors. Preclinical symptoms have been found in populations occupationally exposed to the element, and it is suggested that in late stag...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1517613

    authors: Arnold ML,McNeill FE,Stronach IM,Pejovic-Milic A,Chettle DR,Waker A

    更新日期:2002-11-01 00:00:00

  • SU-E-T-610: Impact of Variable Beam Spot Size on Treatment Time in Particle Therapy.

    abstract:PURPOSE:The dosimetric advantage of particle therapy comes with a much higher infrastructure investment and operation costs. Increasing patient throughput is a key factor to manage operation costs. We investigate the impact of variable beam spot sizes on treatment time and discuss the tradeoffs involved. METHODS:The f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735699

    authors: Riofrio D,Sellner S,Cabal G,Keyes R,Holzscheiter M,Jaekel O,Luan S

    更新日期:2012-06-01 00:00:00

  • A Monte Carlo study on the collimation of pencil beam scanning proton therapy beams.

    abstract:PURPOSE:The lateral edge of a proton therapy beam is commonly used to achieve conformality to the treatment volume where critical structures reside close to the target. However, when treating shallow depths, the lateral edge of a pencil beam scanning (PBS) system may be broader than that of a double scattered (DS) syst...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4941957

    authors: Charlwood FC,Aitkenhead AH,Mackay RI

    更新日期:2016-03-01 00:00:00

  • Portal dose image (PDI) prediction for dosimetric treatment verification in radiotherapy. I. An algorithm for open beams.

    abstract::A method is presented for calculation of transmission functions for high energy photon beams through patients. These functions are being used in our clinic for prediction of portal dose images (PDIs) which are compared with PDIs measured with an electronic portal imaging device (EPID). The calculations are based on th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598293

    authors: Pasma KL,Heijmen BJ,Kroonwijk M,Visser AG

    更新日期:1998-06-01 00:00:00

  • Multigroup discrete ordinates modeling of 125I 6702 seed dose distributions using a broad energy-group cross section representation.

    abstract::Our purpose in this work is to demonstrate that the efficiency of dose-rate computations in 125I brachytherapy, using multigroup discrete ordinates radiation transport simulations, can be significantly enhanced using broad energy group cross sections without a loss of accuracy. To this end, the DANTSYS multigroup disc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1429238

    authors: Daskalov GM,Baker RS,Rogers DW,Williamson JF

    更新日期:2002-02-01 00:00:00

  • Computational modeling of 915 MHz microwave ablation: Comparative assessment of temperature-dependent tissue dielectric models.

    abstract:PURPOSE:The objective of this study is to develop a computational model for simulating 915 MHz microwave ablation (MWA), and verify the simulation predictions of transient temperature profiles against experimental measurements. Due to the limited experimental data characterizing temperature-dependent changes of tissue ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12359

    authors: Deshazer G,Hagmann M,Merck D,Sebek J,Moore KB,Prakash P

    更新日期:2017-09-01 00:00:00

  • Low dose positron emission tomography emulation from decimated high statistics: A clinical validation study.

    abstract:PURPOSE:The fundamental nature of positron emission tomography (PET), as an event detection system, provides some flexibility for data handling, including retrospective data manipulation. The reorganization of acquisition data allows the emulation of new scans arising from identical radiotracer spatial distributions, b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13517

    authors: Schaefferkoetter J,Nai YH,Reilhac A,Townsend DW,Eriksson L,Conti M

    更新日期:2019-06-01 00:00:00

  • Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart.

    abstract::Subsecond single-slice, multi-slice or cone-beam spiral computed tomography (SSCT, MSCT, CBCT) offer great potential for improving heart imaging. Together with the newly developed phase-correlated cardiac reconstruction algorithms 180 degrees MCD and 180 degrees MCI [Med. Phys. 27, 1881-1902 (2000)] or related algorit...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1487861

    authors: Kachelriess M,Sennst DA,Maxlmoser W,Kalender WA

    更新日期:2002-07-01 00:00:00

  • Effect of lateral boundaries on contrast functions in time-resolved transillumination measurements.

    abstract::The method of images is employed to insert the effects of the presence of a single lateral boundary on contrast functions previously derived for an infinite slab using a random walk model of photon transport. The predictions of the model for zero and extrapolated boundary conditions are compared with Monte Carlo (MC) ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598687

    authors: Chernomordik V,Gandjbakhche AH,Hebden JC,Zaccanti G

    更新日期:1999-09-01 00:00:00

  • X-ray scatter correction in breast tomosynthesis with a precomputed scatter map library.

    abstract:PURPOSE:To develop and evaluate the impact on lesion conspicuity of a software-based x-ray scatter correction algorithm for digital breast tomosynthesis (DBT) imaging into which a precomputed library of x-ray scatter maps is incorporated. METHODS:A previously developed model of compressed breast shapes undergoing mamm...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4866229

    authors: Feng SS,D'Orsi CJ,Newell MS,Seidel RL,Patel B,Sechopoulos I

    更新日期:2014-03-01 00:00:00

  • Projection-based improvement of 3D reconstructions from motion-impaired dental cone beam CT data.

    abstract:PURPOSE:Computed tomography (CT) and, in particular, cone beam CT (CBCT) have been increasingly used as a diagnostic tool in recent years. Patient motion during acquisition is common in CBCT due to long scan times. This results in degraded image quality and may potentially increase the number of retakes. Our aim was to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13731

    authors: Niebler S,Schömer E,Tjaden H,Schwanecke U,Schulze R

    更新日期:2019-10-01 00:00:00

  • SU-E-J-106: Atlas-Based Segmentation: Evaluation of a Multi-Atlas Approach for Lung Cancer.

    abstract:PURPOSE:Previous studies have shown atlas-based segmentation using a single best matched (SBM) atlas subject can significantly reduce contouring time. A new multi-atlas approach has been shown to provide greater accuracy than SBM for cancer of the head and neck. The goal of this study was to evaluate the multi-atlas te...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734942

    authors: Pirozzi S,Horvat M,Piper J,Nelson A

    更新日期:2012-06-01 00:00:00

  • Analysis of generalized rosette trajectory for compressed sensing MRI.

    abstract:PURPOSE:The application of compressed sensing (CS) technology in magnetic resonance imaging (MRI) is to accelerate the MRI scan speed by incoherent undersampling of k-space data and nonlinear iterative reconstruction of MRI images. This paper generalizes the existing rosette trajectories to configure the sampling patte...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4928152

    authors: Li Y,Yang R,Zhang C,Zhang J,Jia S,Zhou Z

    更新日期:2015-09-01 00:00:00

  • Anisotropy functions for 103Pd, 125I, and 192Ir interstitial brachytherapy sources.

    abstract::Anisotropy of dose distributions around 103Pd, 125I, and 192Ir sources for interstitial brachytherapy was examined. Dose rates around 125I models 6702 and 6711 and 192Ir sources were measured using lithium fluoride thermoluminescence dosimeters (LiF TLDs) in a water-equivalent, solid phantom. From these measured data ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597110

    authors: Nath R,Meigooni AS,Muench P,Melillo A

    更新日期:1993-09-01 00:00:00

  • Accurate assessment and prediction of noise in clinical CT images.

    abstract:PURPOSE:The objectives of this study were (a) to devise a technique for measuring quantum noise in clinical body computed tomography (CT) images and (b) to develop a model for predicting that noise with high accuracy. METHODS:The study included 83 clinical image sets at two dose levels (clinical and 50% reduced dose l...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4938588

    authors: Tian X,Samei E

    更新日期:2016-01-01 00:00:00

  • Simplifying volumes-of-interest (VOIs) definition in quantitative SPECT: Beyond manual definition of 3D whole-organ VOIs.

    abstract:PURPOSE:We investigated the feasibility of using simpler methods than manual whole-organ volume-of-interest (VOI) definition to estimate the organ activity concentration in single photon emission computed tomography (SPECT) in cases where the activity in the organ can be assumed to be uniformly distributed on the scale...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12164

    authors: Vicente EM,Lodge MA,Rowe SP,Wahl RL,Frey EC

    更新日期:2017-05-01 00:00:00

  • A correction-based dose calculation algorithm for kilovoltage x rays.

    abstract::Frequent and repeated imaging procedures such as those performed in image-guided radiotherapy (IGRT) programs may add significant dose to radiosensitive organs of radiotherapy patients. It has been shown that kV-CBCT results in doses to bone that are up to a factor of 3-4 higher than those in surrounding soft tissue. ...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.3014197

    authors: Ding GX,Pawlowski JM,Coffey CW

    更新日期:2008-12-01 00:00:00

  • Modification of the TASMIP x-ray spectral model for the simulation of microfocus x-ray sources.

    abstract:PURPOSE:The availability of accurate and simple models for the estimation of x-ray spectra is of great importance for system simulation, optimization, or inclusion of photon energy information into data processing. There is a variety of publicly available tools for estimation of x-ray spectra in radiology and mammograp...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4837220

    authors: Sisniega A,Desco M,Vaquero JJ

    更新日期:2014-01-01 00:00:00

  • SU-D-211-06: The Effect of Motion in RapidArc Lung SBRT Delivery.

    abstract:PURPOSE:RapidArc is routinely used for stereotactic radiotherapy for lung cancer. While treatment dose is optimized and calculated on a static CT image, the motion of the target in conjunction with the motion of the MLC may Result in a delivered dose deviating from the planed dose. In this study, we investigate the dos...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734660

    authors: Zou J,Yin L,Shen J,Corradetti M,Kirk M,Rengan R,Teo BK

    更新日期:2012-06-01 00:00:00

  • Repeatability of SUV measurements in serial PET.

    abstract:PURPOSE:The standardized uptake value (SUV) is a quantitative measure of FDG tumor uptake frequently used as a tool to monitor therapeutic response. This study aims to (i) assess the reproducibility and uncertainty of SUV max and SUV mean, due to purely statistical, i.e., nonbiological, effects and (ii) to establish th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3578604

    authors: Schwartz J,Humm JL,Gonen M,Kalaigian H,Schoder H,Larson SM,Nehmeh SA

    更新日期:2011-05-01 00:00:00

  • Displacement-based binning of time-dependent computed tomography image data sets.

    abstract::Respiration can cause tumors in the thorax or abdomen to move by as much as 3 cm; this movement can adversely affect the planning and delivery of radiation treatment. Several techniques have been used to compensate for respiratory motion, but all have shortcomings. Manufacturers of computed tomography (CT) equipment h...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2044427

    authors: Fitzpatrick MJ,Starkschall G,Antolak JA,Fu J,Shukla H,Keall PJ,Klahr P,Mohan R

    更新日期:2006-01-01 00:00:00