Abstract:
PURPOSE/OBJECTIVE:Couch and MLC tracking are two novel techniques to mitigate intrafractional tumor motion on a conventional linear accelerator, but both techniques still have residual dosimetric errors. Here, we first propose and experimentally validate a software tool to simulate couch and MLC tracking, and then use the simulator to study hybrid couch-MLC tracking for improved tracking performance. MATERIALS AND METHODS:The tracking simulator requires a treatment plan and a motion trajectory as input and simulates the delivered monitor units and motion of all accelerator parts as function of time. The simulator outputs accelerator log files synchronized with the target motion as well as the MLC exposure error, which is a simple dose error surrogate. A series of couch and MLC tracking experiments were used to determine appropriate parameters for the simulator dynamics and to validate the simulator by its ability to reproduce the experimental tracking accuracy. Three hybrid couch-MLC tracking strategies were investigated. All strategies divided the target motion in beam's eye view into motion perpendicular and parallel to the MLC leaves. In the hybrid strategies, couch tracking compensated for the following target motion components (in order of decreasing couch tracking contribution): (a) all perpendicular motion, (b) residual perpendicular motion less than half a leaf width, and (c) persistent residual perpendicular motion that was stable at a time scale of 1s. MLC tracking compensated for the remaining target motion. All tracking strategies were simulated with two prostate and two lung cancer single-arc VMAT plans using 695 prostate trajectories and 160 lung tumor trajectories. The tracking error was quantified as the MLC exposure error. The couch motion was quantified as the mean speed, acceleration, and jerk of the couch. RESULTS:The simulator reproduced the experimental gantry position with a mean (maximum) root-mean-square (rms) error of 0.07°(0.2°). The geometrical rms tracking error was reproduced with mean (maximum) absolute errors of 0.20 mm(0.23 mm) and 0.1 mm(0.23 mm) for MLC tracking parallel and perpendicular to the MLC leaves, and 0.40 mm(0.46 mm), 0.09 mm(0.25 mm), and 0.20 mm(0.46 mm) for couch tracking in the left-right, anterior-posterior, and cranio-caudal directions. The MLC exposure error of VMAT MLC tracking was reproduced with a mean absolute error of 5.6%. All hybrid tracking strategies reduced the couch motion relative to pure couch tracking and improved the tracking accuracy compared with pure MLC tracking. The mean MLC exposure error reduction relative to no tracking was 66.6% (couch tracking), 72.9% (hybrid (1)), 70.2% (2), 59.1% (3), and 55.6% (MLC tracking) for lung tumor motion and 76.5% (couch tracking), 76.1% (1), 74.3% (2), 72.3% (3), and 35.9% (MLC tracking) for prostate motion. For prostate motion, pure MLC tracking resulted in rather large MLC exposure errors that were more than halved with all hybrid tracking strategies. CONCLUSION:A couch and MLC tracking simulator was developed and experimentally validated against a series of tracking experiments. All hybrid couch-MLC tracking strategies improved MLC tracking. Two strategies also improved couch tracking of lung tumors. In particular, MLC tracking of prostate may be greatly improved by a modest degree of couch motion.
journal_name
Med Physjournal_title
Medical physicsauthors
Toftegaard J,Hansen R,Ravkilde T,Macek K,Poulsen PRdoi
10.1002/mp.12104subject
Has Abstractpub_date
2017-03-01 00:00:00pages
798-809issue
3eissn
0094-2405issn
2473-4209journal_volume
44pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::By design, the range of beam directions in conventional radiosurgery are constrained to an isocentric array. However, the recent introduction of robotic radiosurgery dramatically increases the flexibility of targeting, and as a consequence, beams need be neither coplanar nor isocentric. Such a nonisocentric design per...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2357020
更新日期:2006-11-01 00:00:00
abstract::Intensity Modulated Arc Therapy (IMAT) is a rotational variant of Intensity Modulated Radiation Therapy (IMRT) that can be implemented with or without angular dose rate optimization. The purpose of this study is to determine the inter-relationship among arc range, Multi-Leaf Collimator (MLC) leaf positions and angular...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965975
更新日期:2008-07-01 00:00:00
abstract:PURPOSE:Carpal tunnel syndrome (CTS) is the common entrapment neuropathy that occurs due to compression of the median nerve at the wrist. Ultrasound images have been used to highlight anatomical variants of the median nerve, and CTS is thought to be associated to enlargement of the cross-sectional area (CSA) of the med...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4767754
更新日期:2012-12-01 00:00:00
abstract::A new high dose rate 20 mm 32P intravascular brachytherapy (IVB) beta source used with automated stepping has recently been introduced. The AAPM Task Group 60 recommends that beta IVB sources should have well characterized dosimetric parameters in water. In this study, Monte Carlo simulations (MCNPX v 2.4) were used t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1646651
更新日期:2004-03-01 00:00:00
abstract::Numerical reconstruction of x-ray spectra from narrow-beam transmission data was tested with published spectra in the range from 45 to 100 kVp. Transmission curves were calculated from the spectra to simulate measured data. Spectra were reconstructed from these transmission curves with use of an iterative numerical an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595834
更新日期:1986-09-01 00:00:00
abstract:PURPOSE:The limited-angle intrafractional verification (LIVE) system was developed to track tumor movement during stereotactic body radiation therapy (SBRT). However, the four-dimensional (4D) MV/kV imaging procedure results in additional radiation dose to patients. This study is to quantify imaging radiation dose from...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13511
更新日期:2019-06-01 00:00:00
abstract:PURPOSE:Wide-angle free-air chambers (WAFACs) are used as primary standard measurement devices for establishing the air-kerma strength of low-energy, low-dose rate brachytherapy seeds. The National Research Council of Canada (NRC) is commissioning a primary standard wide-angle free-air chamber (NRC WAFAC) to serve the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4951727
更新日期:2016-07-01 00:00:00
abstract:PURPOSE:To present the results of a patient dose evaluation program in pediatric cardiology and propose local diagnostic reference levels (DRLs) for different types of procedure and age range, in addition to suggesting approaches to correlate patient dose values with patient weight. This study was the first conducted i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4905116
更新日期:2015-02-01 00:00:00
abstract::Quantitation of planar radionuclide images is hampered by structures containing radioactivity which overlie or underlie the organ of interest. The introduction of single photon emission computerized tomography (SPECT) overcame this problem to a large extent and enhanced the contrast of the images. Attenuation of photo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596684
更新日期:1991-05-01 00:00:00
abstract::In many of brachytherapy procedures, a large amount of radioactive sources are used to deliver desired doses to the target volume. It is both the federal regulation recommendation (U.S. Nuclear Regulatory Commission, 10 CFR 35.432) and recommendations of the American Association of Physicists in Medicine (AAPM) [Kutch...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2734723
更新日期:2007-06-01 00:00:00
abstract::The physical imaging performance of ST-V, ST-VA, and ST-VN computed radiography image plates, read with a Philips AC3 acquisition system, was investigated at 70 kVp with 0.5 mm of copper beam filtration for four different entrance air kerma values: 0.5, 2.6, 26, and 260 micro Gy. Measurements included characteristic r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598412
更新日期:1998-11-01 00:00:00
abstract::Various techniques have been developed to localize radioactive sources in brachytherapy implants. The most common methods include the orthogonal film method, the stereo-shift film method, and recently, direct localization from a series of contiguous CT transverse images. The major advantage of the CT method is that it...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598548
更新日期:1999-04-01 00:00:00
abstract::Monte Carlo calculations have been made to determine the energy delivered to a phantom by neutrons escaping from the head of a Varian Clinac 35 medical accelerator at an SSD of 1 m. The energy was sorted into two regions: inside and outside a volume defined by a circular beam of area 100 and 600 cm2. For the two beam ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595067
更新日期:1982-01-01 00:00:00
abstract::Electron spectral reconstruction of medical accelerators from measured depth doses is a practical method for providing the input initial phase space distribution at the patient surface that is required by Monte Carlo treatment planning systems. The posed inverse problem of spectral reconstruction is ill conditioned an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2161404
更新日期:2006-02-01 00:00:00
abstract:PURPOSE:To investigate the difference of MR percent breast density measured from fat-suppressed versus nonfat-suppressed imaging sequences. METHODS:Breast magnetic resonance imaging (MRI) with and without fat suppression was acquired from 38 subjects. Breasts were divided into subgroups of different morphological patt...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3646756
更新日期:2011-11-01 00:00:00
abstract:PURPOSE:The authors investigate performance of thin-film cadmium telluride (CdTe) in detecting high-energy (6 MV) x rays. The utilization of this material has become technologically feasible only in recent years due to significant development in large area photovoltaic applications. METHODS:The CdTe film is combined w...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3438082
更新日期:2010-08-01 00:00:00
abstract:PURPOSE:IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4921617
更新日期:2015-07-01 00:00:00
abstract:PURPOSE:The collimator monitoring fill factor (CM-FF) introduced by Stelljes et al. (2017) and the FWHM fill factor (FWHM-FF) introduced by Gago-Arias et al. (2012) were determined using the measured photon fluence response functions of various 2D-arrays. The error detection capabilities of 2D-arrays were studied by co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13417
更新日期:2019-04-01 00:00:00
abstract::New x-ray radiographic systems based on large-area flat-panel technology have revolutionized our capability to produce digital x-ray images. However, these imagers are extraordinarily expensive compared to the systems they are replacing. Hence, there is a need for a low-cost digital imaging system for general applicat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2837288
更新日期:2008-03-01 00:00:00
abstract::A simple approach was developed that calculates the output factors and tissue maximum ratio of an asymmetric field at any point within the open field, and specifically both at the central axis (when the jaws do not shadow it) and at the effective center of the open field, using the existing tables for symmetric fields...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597524
更新日期:1995-01-01 00:00:00
abstract::The purpose of this work is to compare the efficacy of mathematical models in predicting the occurrence of radiotherapy-induced left ventricular perfusion defects assessed using single-photon emission computed tomography (SPECT). The basis of this study is data from 73 left-sided breast/ chestwall patients treated wit...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1823571
更新日期:2005-01-01 00:00:00
abstract:PURPOSE:An improved method of image guidance for lung tumor biopsies could help reduce the high rate of false negatives. The aim of this work is to optimize the geometry of the scanning-beam digital tomography system (SBDX) for providing real-time 3D tomographic reconstructions for target verification. The unique geome...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4826159
更新日期:2013-11-01 00:00:00
abstract:PURPOSE:To evaluate the replacement of Cerrobend by copper for electron beam cutouts. METHODS:The dosimetric comparisons for circular copper-and Cerrobend-cutouts with diameters (1.0, 2.0, 3.0, 5.0, 7.5, 10.0, and 12.5 cm) were made using electron beams with energies (6, 9, 12, 16, and 20 MeV) from 3 Varian accelerato...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735336
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Radiopharmaceutical applications in nuclear medicine require a detailed dosimetry estimate of the radiation energy delivered to the human tissues. Over the past years, several publications addressed the problem of internal dose estimate in volumes of several sizes considering photon and electron sources. Most o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3242304
更新日期:2009-11-01 00:00:00
abstract::This study compared air exposures during conventional dental and maxillofacial radiography and similar views using free-focus radiography with conventional image receptors. The results show that periapical type surveys on nonscreen film placed extraorally or in the buccal fold may be carried out with an exposure to th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594690
更新日期:1980-07-01 00:00:00
abstract:PURPOSE:The purpose of this study is to investigate whether the microvascular pseudodiffusion effects resulting with non-monoexponential behavior are present in breast cancer, taking into account tumor spatial heterogeneity. Additionally, methodological factors affecting the signal in low and high diffusion-sensitizing...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4927255
更新日期:2015-08-01 00:00:00
abstract:PURPOSE:Diffusion magnetic resonance imaging (MRI) in combination with functional MRI promises a whole new vista for scientists to investigate noninvasively the structural and functional connectivity of the human brain-the human connectome, which had heretofore been out of reach. As with other imaging modalities, diffu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3700166
更新日期:2012-05-01 00:00:00
abstract::Setting up and maintaining video display monitors properly will help to reduce display variation and improve overall presentation of the radiological image. Display monitor gray-scale characteristics were examined using the SMPTE test pattern. This test pattern may be used as a standard for adjusting brightness and co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596846
更新日期:1992-05-01 00:00:00
abstract:PURPOSE:To assess current education, practices, attitudes, and perceptions pertaining to ethics and professionalism in medical physics. METHODS:A link to a web-based survey was distributed to the American Association of Physicists in Medicine (AAPM) e-mail membership list, with a follow-up e-mail sent two weeks later....
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4797463
更新日期:2013-04-01 00:00:00
abstract:PURPOSE:Particle therapy is becoming increasingly available world-wide for precise tumor targeting, its favorable depth dose deposition, and increased biological damage to tumor tissue compared to conventional photon therapy. As demand increases for improved robustness and conformality, next-generation secondary dose c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14417
更新日期:2020-10-01 00:00:00