An observer study comparing spot imaging regions selected by radiologists and a computer for an automated stereo spot mammography technique.

Abstract:

:We are developing an automated stereo spot mammography technique for improved imaging of suspicious dense regions within digital mammograms. The technique entails the acquisition of a full-field digital mammogram, automated detection of a suspicious dense region within that mammogram by a computer aided detection (CAD) program, and acquisition of a stereo pair of images with automated collimation to the suspicious region. The latter stereo spot image is obtained within seconds of the original full-field mammogram, without releasing the compression paddle. The spot image is viewed on a stereo video display. A critical element of this technique is the automated detection of suspicious regions for spot imaging. We performed an observer study to compare the suspicious regions selected by radiologists with those selected by a CAD program developed at the University of Michigan. True regions of interest (TROIs) were separately determined by one of the radiologists who reviewed the original mammograms, biopsy images, and histology results. We compared the radiologist and computer-selected regions of interest (ROIs) to the TROIs. Both the radiologists and the computer were allowed to select up to 3 regions in each of 200 images (mixture of 100 CC and 100 MLO views). We computed overlap indices (the overlap index is defined as the ratio of the area of intersection to the area of interest) to quantify the agreement between the selected regions in each image. The averages of the largest overlap indices per image for the 5 radiologist-to-computer comparisons were directly related to the average number of regions per image traced by the radiologists (about 50% for 1 region/image, 84% for 2 regions/image and 96% for 3 regions/image). The average of the overlap indices with all of the TROIs was 73% for CAD and 76.8% +/- 10.0% for the radiologists. This study indicates that the CAD determined ROIs could potentially be useful for a screening technique that includes stereo spot mammography imaging.

journal_name

Med Phys

journal_title

Medical physics

authors

Goodsitt MM,Chan HP,Lydick JT,Gandra CR,Chen NG,Helvie MA,Bailey JE,Roubidoux MA,Paramagul C,Blane CE,Sahiner B,Petrick NA

doi

10.1118/1.1737492

subject

Has Abstract

pub_date

2004-06-01 00:00:00

pages

1558-67

issue

6

eissn

0094-2405

issn

2473-4209

journal_volume

31

pub_type

杂志文章
  • Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter - Part I: Core algorithms and validation.

    abstract:PURPOSE:To describe Acuros® CTS, a new software tool for rapidly and accurately estimating scatter in x-ray projection images by deterministically solving the linear Boltzmann transport equation (LBTE). METHODS:The LBTE describes the behavior of particles as they interact with an object across spatial, energy, and dir...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12850

    authors: Maslowski A,Wang A,Sun M,Wareing T,Davis I,Star-Lack J

    更新日期:2018-05-01 00:00:00

  • A fast, noniterative approach for accelerated high-temporal resolution cine-CMR using dynamically interleaved streak removal in the power-spectral encoded domain with low-pass filtering (DISPEL) and modulo-prime spokes (MoPS).

    abstract:PURPOSE:To introduce a pair of accelerated non-Cartesian acquisition principles that when combined, exploit the periodicity of k-space acquisition, and thereby enable acquisition of high-temporal cine Cardiac Magnetic Resonance (CMR). METHODS:The mathematical formulation of a noniterative, undersampled non-Cartesian c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12234

    authors: Kawaji K,Patel MB,Cantrell CG,Tanaka A,Marino M,Tamura S,Wang H,Wang Y,Carroll TJ,Ota T,Patel AR

    更新日期:2017-07-01 00:00:00

  • Pharmacokinetic modeling.

    abstract::For radiation dosimetry calculations of radiolabeled monoclonal antibodies, (MAB), pharmacokinetics are critical. Specifically, pharmacokinetic modeling is a useful component of estimation of cumulated activity in various source organs in the body. It is thus important to formulate general methods of pharmacokinetic m...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.597047

    authors: Strand SE,Zanzonico P,Johnson TK

    更新日期:1993-03-01 00:00:00

  • Dosimetric verification of IMAT delivery with a conventional EPID system and a commercial portal dose image prediction tool.

    abstract:PURPOSE:The electronic portal imaging device (EPID) is a system for checking the patient setup; as a result of its integration with the linear accelerator and software customized for dosimetry, it is increasingly used for verification of the delivery of fixed-field intensity-modulated radiation therapy (IMRT). In order...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3271107

    authors: Iori M,Cagni E,Paiusco M,Munro P,Nahum AE

    更新日期:2010-01-01 00:00:00

  • Accuracy of respiratory motion measurement of 4D-MRI: A comparison between cine and sequential acquisition.

    abstract:PURPOSE:The authors have recently developed a cine-mode T2*/T1-weighted 4D-MRI technique and a sequential-mode T2-weighted 4D-MRI technique for imaging respiratory motion. This study aims at investigating which 4D-MRI image acquisition mode, cine or sequential, provides more accurate measurement of organ motion during ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4938066

    authors: Liu Y,Yin FF,Rhee D,Cai J

    更新日期:2016-01-01 00:00:00

  • SU-E-T-622: A Rapid Hybrid VMAT-IMRT Planning Method Using an Abbreviated Beam Angle Optimization Search.

    abstract:PURPOSE:To generate hybrid VMAT-IMRT treatment plans by utilizing an IMRT beam-angle-optimality (BAO) search under a commercially available TPS without the aid of custom optimization software or high performance computing. METHODS:The high dose modulation provided by IMRT beams can be exploited to improve the quality ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735712

    authors: Schulze D,Ionascu D,Tyagi N

    更新日期:2012-06-01 00:00:00

  • Experimental implementation of a joint statistical image reconstruction method for proton stopping power mapping from dual-energy CT data.

    abstract:PURPOSE:To experimentally commission a dual-energy CT (DECT) joint statistical image reconstruction (JSIR) method, which is built on a linear basis vector model (BVM) of material characterization, for proton stopping power ratio (SPR) estimation. METHODS:The JSIR-BVM method builds on the relationship between the energ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13287

    authors: Zhang S,Han D,Williamson JF,Zhao T,Politte DG,Whiting BR,O'Sullivan JA

    更新日期:2019-01-01 00:00:00

  • A sparse representation-based radiomics for outcome prediction of higher grade gliomas.

    abstract:PURPOSE:Accurately predicting outcome (i.e., overall survival (OS) time) for higher grade glioma (HGG) has great clinical value and would provide optimized guidelines for treatment planning. Radiomics focuses on revealing underlying pathophysiological information in biomedical images for disease analysis and demonstrat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13288

    authors: Wu G,Shi Z,Chen Y,Wang Y,Yu J,Lv X,Chen L,Ju X,Chen Z

    更新日期:2019-01-01 00:00:00

  • GateCT™ surface tracking system for respiratory signal reconstruction in 4DCT imaging.

    abstract:PURPOSE:To assess the temporal and spatial accuracy of the GateCT™ system (VisionRT, London, UK), a recently released respiratory tracking system for 4DCT, under both ideal and nonideal respiratory conditions. METHODS:Three experiments were performed by benchmarking and comparing its results with the ground-truth inpu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3671941

    authors: Kauweloa KI,Ruan D,Park JC,Sandhu A,Kim GY,Pawlicki T,Watkins WT,Song B,Song WY

    更新日期:2012-01-01 00:00:00

  • Backscatter factors in the mammographic energy range.

    abstract::Backscatter factors for kVps and half-value layers typical of mammographic beams have been determined as a function of beam diameter and half-value layer. The method utilized thin TLD-100 chips with the scattering medium alternately present and absent. Results indicate that the field-size dependence of the backscatter...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594312

    authors: Dubuque GL,Cacak RK,Hendee WR

    更新日期:1977-09-01 00:00:00

  • A system for intensity modulated dose plan verification based on an experimental pencil beam kernel obtained by deconvolution.

    abstract::The number of intensity modulated radiation therapy (IMRT) procedures is continuously growing worldwide and it is necessary to develop tools for patient specific quality assurance (QA) that avoid using machine time that could be employed in treating additional patients. One way of achieving this goal is to perform a m...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2815359

    authors: Azcona JD,Burguete J

    更新日期:2008-01-01 00:00:00

  • Technical note: An algorithm to calculate the tissue phantom ratio from depth dose in radiosurgery.

    abstract:PURPOSE:To propose a method to calculate the tissue phantom ratio (TPR) using the depth dose and to compare the proposed method with two other methods. METHODS:An analytical dose model from Bjärngard was used to describe the depth dose and the TPR. The parameters of the model were derived from depth dose measurements,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3570575

    authors: Ramos Garcia LI,Almansa JF

    更新日期:2011-05-01 00:00:00

  • Noninvasive cardiac arrhythmia ablation with particle beams.

    abstract::Cardiac arrhythmias are a major health burden, associated with reduced quality of life and substantial morbidity and mortality. Current therapy includes moderately effective medication and catheter-based ablation of arrhythmogenic substrates in the heart. Catheter interventions frequently have to be repeated due to re...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.12595

    authors: Graeff C,Bert C

    更新日期:2018-11-01 00:00:00

  • The role of humidity and other correction factors in the AAPM TG-21 dosimetry protocol.

    abstract::A detailed derivation is presented of the formulas required to determine Ngas and Dmed in the AAPM TG-21 dosimetry protocol. This protocol specifies how to determine the absorbed dose in an electron or photon beam when using exposure or absorbed dose calibrated ion chambers. It is shown that the expression given in TG...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596292

    authors: Rogers DW,Ross CK

    更新日期:1988-01-01 00:00:00

  • A beam intensity monitor for the Loma Linda cancer therapy proton accelerator.

    abstract::A beam intensity monitor was tested in a 230-MeV proton beam at the Loma Linda Proton Therapy Accelerator during its commissioning at Fermi National Accelerator Laboratory. The intensity monitor was designed to regulate the beam intensity extracted from the proton synchrotron. The proton beam is tunable between 70 and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596636

    authors: Coutrakon G,Miller D,Kross BJ,Anderson DF,DeLuca P Jr,Siebers J

    更新日期:1991-07-01 00:00:00

  • Technical Note: exploring the limit for the conversion of energy-subtracted CT number to electron density for high-atomic-number materials.

    abstract:PURPOSE:For accurate tissue inhomogeneity correction in radiotherapy treatment planning, the authors had previously proposed a novel conversion of the energy-subtracted CT number to an electron density (ΔHU-ρe conversion), which provides a single linear relationship between ΔHU and ρe over a wide ρe range. The purpose ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4881327

    authors: Saito M,Tsukihara M

    更新日期:2014-07-01 00:00:00

  • Image reconstruction for positron emission tomography based on patch-based regularization and dictionary learning.

    abstract:PURPOSE:Positron emission tomography (PET) is an important tool for nuclear medical imaging. It has been widely used in clinical diagnosis, scientific research, and drug testing. PET is a kind of emission computed tomography. Its basic imaging principle is to use the positron annihilation radiation generated by radionu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13804

    authors: Zhang W,Gao J,Yang Y,Liang D,Liu X,Zheng H,Hu Z

    更新日期:2019-11-01 00:00:00

  • Reconstruction of 4-MV bremsstrahlung spectra from measured transmission data.

    abstract::Transmission data for 4-MV bremsstrahlung beams have been measured with a combination of lead and aluminum attenuators. From these data, the original energy spectra have been reconstructed using an iterative least-squares technique, previously evaluated by simulation studies. The spectra on the central axis for three ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595356

    authors: Huang PH,Kase KR,Bjärngard BE

    更新日期:1983-11-01 00:00:00

  • Acceptance testing and quality assurance of automated scanning film densitometers used in the dosimetry of electron and photon therapy beams.

    abstract::Scanning film densitometry routinely used for obtaining dosimetric information about therapy treatment beams is subject to several sources of inaccuracies. The most significant of these are described and appropriate methods of testing are presented. This establishes the need for adequate acceptance testing followed by...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595407

    authors: Holmes TW,McCullough EC

    更新日期:1983-09-01 00:00:00

  • DCE-MRI defined subvolumes of a brain metastatic lesion by principle component analysis and fuzzy-c-means clustering for response assessment of radiation therapy.

    abstract:PURPOSE:To develop a pharmacokinetic modelfree framework to analyze the dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) data for assessment of response of brain metastases to radiation therapy. METHODS:Twenty patients with 45 analyzable brain metastases had MRI scans prior to whole brain radiation thera...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4842556

    authors: Farjam R,Tsien CI,Lawrence TS,Cao Y

    更新日期:2014-01-01 00:00:00

  • Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology.

    abstract::The performance of an indirect-detection, active matrix flat-panel imager (FPI) at diagnostic energies is reported in terms of measured and theoretical signal size, noise power spectrum (NPS), and detective quantum efficiency (DQE). Based upon a 1536 x 1920 pixel, 127 microns pitch array of a-Si:H thin-film transistor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598243

    authors: Siewerdsen JH,Antonuk LE,el-Mohri Y,Yorkston J,Huang W,Cunningham IA

    更新日期:1998-05-01 00:00:00

  • X-ray diffraction computed tomography.

    abstract::Coherent scattering of x-ray photons leads to the phenomenon of x-ray diffraction, which is widely used for determining atomic structure in materials science. A technique [x-ray diffraction computed tomography (CT)] is described, analogous to conventional CT, in which the x-ray diffraction properties of a stack of two...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596063

    authors: Harding G,Kosanetzky J,Neitzel U

    更新日期:1987-07-01 00:00:00

  • Real-time direct diaphragm tracking using kV imaging on a standard linear accelerator.

    abstract:PURPOSE:As the predominant driver of respiratory motion, the diaphragm represents a key surrogate for motion management during the irradiation of thoracic cancers. Existing approaches to diaphragm tracking often produce phase-based estimates, suffer from lateral side failures or are not executable in real-time. In this...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13738

    authors: Hindley N,Keall P,Booth J,Shieh CC

    更新日期:2019-10-01 00:00:00

  • Wavelength dependence of the precision of noninvasive optical measurement of oxy-, deoxy-, and total-hemoglobin concentration.

    abstract::The precision of noninvasive optical measurement of the concentration changes in oxy-, deoxy-, and total-hemoglobin depends on wavelength. For estimating the precision, we calculated the noise level of the concentration changes as the uncertainty in measurements using several wavelength pairs of light. Seven laser dio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1373401

    authors: Yamashita Y,Maki A,Koizumi H

    更新日期:2001-06-01 00:00:00

  • "SABER": A new software tool for radiotherapy treatment plan evaluation.

    abstract:PURPOSE:Both spatial and biological information are necessary in order to perform true optimization of a treatment plan and for predicting clinical outcome. The goal of this work is to develop an enhanced treatment plan evaluation tool which incorporates biological parameters and retains spatial dose information. METH...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3497152

    authors: Zhao B,Joiner MC,Orton CG,Burmeister J

    更新日期:2010-11-01 00:00:00

  • Feasibility of MRI-only treatment planning for proton therapy in brain and prostate cancers: Dose calculation accuracy in substitute CT images.

    abstract:PURPOSE:Magnetic resonance imaging (MRI) is increasingly used for radiotherapy target delineation, image guidance, and treatment response monitoring. Recent studies have shown that an entire external x-ray radiotherapy treatment planning (RTP) workflow for brain tumor or prostate cancer patients based only on MRI refer...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4958677

    authors: Koivula L,Wee L,Korhonen J

    更新日期:2016-08-01 00:00:00

  • An anthropomorphic torso section phantom for ultrasonic imaging.

    abstract::Using stable materials capable of mimicking any soft tissues of the human body--quantitatively with respect to speed of sound, density, and attenuation coefficient and semiquantitatively with respect to scatter--we have constructed a torso section phantom containing simulated bowel gas, kidney, kidney fat pad, liver, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594657

    authors: Madsen EL,Zagzebski JA,Ghilardi-Netto T

    更新日期:1980-01-01 00:00:00

  • Solid-tumor radionuclide therapy dosimetry: new paradigms in view of tumor microenvironment and angiogenesis.

    abstract:PURPOSE:The objective of this study is to evaluate requirements for radionuclide-based solid tumor therapy by assessing the radial dose distribution of beta-particle-emitting and alpha-particle-emitting molecules localized either solely within endothelial cells of tumor vasculature or diffusing from the vasculature thr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3431999

    authors: Zhu X,Palmer MR,Makrigiorgos GM,Kassis AI

    更新日期:2010-06-01 00:00:00

  • SU-E-J-160: 4D Dynamic Arc of Non-Modulated Variable-Dose-Rate Fields for Lung SBRT: A Feasibility Study.

    abstract:PURPOSE:Conformal SBRT plans for Lung cancer with static gantry angles are ideal candidates for applying motion tracking because of: (1) better dosimetric conformity with reduced target margin and (2) easier and more faithful target tracking without intensity modulation. This work is to demonstrate that by delivering t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734998

    authors: Yi B,Yang X,Niu Y,Yu C

    更新日期:2012-06-01 00:00:00

  • A novel and individualized robust optimization method using normalized dose interval volume constraints (NDIVC) for intensity-modulated proton radiotherapy.

    abstract:PURPOSE:Intensity-modulated proton therapy (IMPT) is known to be sensitive to patient setup and range uncertainty issues. Multiple robust optimization methods have been developed to mitigate the impact of these uncertainties. Here, we propose a new robust optimization method, which provides an alternative way of robust...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13276

    authors: Shan J,Sio TT,Liu C,Schild SE,Bues M,Liu W

    更新日期:2019-01-01 00:00:00