An observer study comparing spot imaging regions selected by radiologists and a computer for an automated stereo spot mammography technique.

Abstract:

:We are developing an automated stereo spot mammography technique for improved imaging of suspicious dense regions within digital mammograms. The technique entails the acquisition of a full-field digital mammogram, automated detection of a suspicious dense region within that mammogram by a computer aided detection (CAD) program, and acquisition of a stereo pair of images with automated collimation to the suspicious region. The latter stereo spot image is obtained within seconds of the original full-field mammogram, without releasing the compression paddle. The spot image is viewed on a stereo video display. A critical element of this technique is the automated detection of suspicious regions for spot imaging. We performed an observer study to compare the suspicious regions selected by radiologists with those selected by a CAD program developed at the University of Michigan. True regions of interest (TROIs) were separately determined by one of the radiologists who reviewed the original mammograms, biopsy images, and histology results. We compared the radiologist and computer-selected regions of interest (ROIs) to the TROIs. Both the radiologists and the computer were allowed to select up to 3 regions in each of 200 images (mixture of 100 CC and 100 MLO views). We computed overlap indices (the overlap index is defined as the ratio of the area of intersection to the area of interest) to quantify the agreement between the selected regions in each image. The averages of the largest overlap indices per image for the 5 radiologist-to-computer comparisons were directly related to the average number of regions per image traced by the radiologists (about 50% for 1 region/image, 84% for 2 regions/image and 96% for 3 regions/image). The average of the overlap indices with all of the TROIs was 73% for CAD and 76.8% +/- 10.0% for the radiologists. This study indicates that the CAD determined ROIs could potentially be useful for a screening technique that includes stereo spot mammography imaging.

journal_name

Med Phys

journal_title

Medical physics

authors

Goodsitt MM,Chan HP,Lydick JT,Gandra CR,Chen NG,Helvie MA,Bailey JE,Roubidoux MA,Paramagul C,Blane CE,Sahiner B,Petrick NA

doi

10.1118/1.1737492

subject

Has Abstract

pub_date

2004-06-01 00:00:00

pages

1558-67

issue

6

eissn

0094-2405

issn

2473-4209

journal_volume

31

pub_type

杂志文章
  • A Monte Carlo approach to validation of FFF VMAT treatment plans for the TrueBeam linac.

    abstract:PURPOSE:To commission and benchmark a vendor-supplied (Varian Medical Systems) Monte Carlo phase-space data for the 6 MV flattening filter free (FFF) energy mode on a TrueBeam linear accelerator for the purpose of quality assurance of clinical volumetric modulated arc therapy (VMAT) treatment plans. A method for render...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4773883

    authors: Gete E,Duzenli C,Milette MP,Mestrovic A,Hyde D,Bergman AM,Teke T

    更新日期:2013-02-01 00:00:00

  • Measurements of magnetism-related forces and torque moments affecting medical instruments, implants, and foreign objects during magnetic resonance imaging at all degrees of freedom.

    abstract::We designed a novel force/torque moment transducer with six degrees of freedom. This new sensor is used for measuring the forces and torque moments exerted by static magnetic resonance imaging (MRI) fields on various medical implants, instruments, and ballistic shell fragments. To determine the location of strongest e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597853

    authors: Planert J,Modler H,Vosshenrich R

    更新日期:1996-06-01 00:00:00

  • A multipinhole small animal SPECT system with submillimeter spatial resolution.

    abstract::Single photon emission computed tomography (SPECT) is an important technology for molecular imaging studies of small animals. In this arena, there is an increasing demand for high performance imaging systems that offer improved spatial resolution and detection efficiency. We have designed a multipinhole small animal i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2190332

    authors: Funk T,Després P,Barber WC,Shah KS,Hasegawa BH

    更新日期:2006-05-01 00:00:00

  • Evaluation of three types of reference image data for external beam radiotherapy target localization using digital tomosynthesis (DTS).

    abstract::Digital tomosynthesis (DTS) is a fast, low-dose three-dimensional (3D) imaging approach which yields slice images with excellent in-plane resolution, though low plane-to-plane resolution. A stack of DTS slices can be reconstructed from a single limited-angle scan, with typical scan angles ranging from 10 degrees to 40...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2756941

    authors: Godfrey DJ,Ren L,Yan H,Wu Q,Yoo S,Oldham M,Yin FF

    更新日期:2007-08-01 00:00:00

  • Determining Pion, the correction factor for recombination losses in an ionization chamber.

    abstract::The 1983 AAPM protocol for the determination of absorbed dose from high-energy photon and electron beams recommends using Pion (the reciprocal of collection efficiency), as determined by the two-voltage technique, to correct for recombination losses in ionization chambers. Methods and data for the determination of ion...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595574

    authors: Weinhous MS,Meli JA

    更新日期:1984-11-01 00:00:00

  • Automated segmentation of anatomic regions in chest radiographs using an adaptive-sized hybrid neural network.

    abstract::The purposes of this research are to investigate the effectiveness of our novel image features for segmentation of anatomic regions such as the lungs and the mediastinum in chest radiographs and to develop an automatic computerized method for image processing. A total of 85 screening chest radiographs from Johns Hopki...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598277

    authors: Tsujii O,Freedman MT,Mun SK

    更新日期:1998-06-01 00:00:00

  • Monte Carlo assessment of computed tomography dose to tissue adjacent to the scanned volume.

    abstract::The assessment of the radiation dose to internal organs or to an embryo or fetus is required on occasion for risk assessment or for comparing imaging studies. Limited resources hinder the ability to accurately assess the radiation dose received to locations outside the tissue volume actually scanned during computed to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1312809

    authors: Boone JM,Cooper VN 3rd,Nemzek WR,McGahan JP,Seibert JA

    更新日期:2000-10-01 00:00:00

  • Fast technetium-99m liver SPECT for evaluation of the pretreatment procedure for radioembolization dosimetry.

    abstract:PURPOSE:The efficiency of radioembolization procedures could be greatly enhanced if results of the 99m Tc-MAA pretreatment procedure were immediately available in the interventional suite, enabling 1-day procedures as a result of direct estimation of the hepatic radiation dose and lung shunt fraction. This would, howev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13253

    authors: van der Velden S,Dietze MMA,Viergever MA,de Jong HWAM

    更新日期:2019-01-01 00:00:00

  • A novel and individualized robust optimization method using normalized dose interval volume constraints (NDIVC) for intensity-modulated proton radiotherapy.

    abstract:PURPOSE:Intensity-modulated proton therapy (IMPT) is known to be sensitive to patient setup and range uncertainty issues. Multiple robust optimization methods have been developed to mitigate the impact of these uncertainties. Here, we propose a new robust optimization method, which provides an alternative way of robust...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13276

    authors: Shan J,Sio TT,Liu C,Schild SE,Bues M,Liu W

    更新日期:2019-01-01 00:00:00

  • Calculation of photon energy deposition kernels and electron dose point kernels in water.

    abstract::Effects of changes in the physics of EGSnrc compared to EGS4/PRESTA on energy deposition kernels for monoenergetic photons and on dose point kernels for beta sources in water are investigated. In the diagnostic energy range, Compton binding corrections were found to increase the primary energy fraction up to 4.5% at 3...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1861412

    authors: Mainegra-Hing E,Rogers DW,Kawrakow I

    更新日期:2005-03-01 00:00:00

  • An accelerated threshold-based back-projection algorithm for compton camera image reconstruction.

    abstract:PURPOSE:Compton camera imaging (CCI) systems are currently under investigation for radiotherapy dose reconstruction and verification. The ability of such a system to provide real-time images during dose delivery will be limited by the computational speed of the image reconstruction algorithm. In this work, the authors ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3519873

    authors: Mundy DW,Herman MG

    更新日期:2011-01-01 00:00:00

  • Validation of GPUMCD for low-energy brachytherapy seed dosimetry.

    abstract:PURPOSE:To validate GPUMCD, a new package for fast Monte Carlo dose calculations based on the GPU (graphics processing unit), as a tool for low-energy single seed brachytherapy dosimetry for specific seed models. As the currently accepted method of dose calculation in low-energy brachytherapy computations relies on sev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3598441

    authors: Hissoiny S,Ozell B,Després P,Carrier JF

    更新日期:2011-07-01 00:00:00

  • Efficient implementations of a pseudodynamical stochastic filtering strategy for static elastography.

    abstract::A computationally efficient pseudodynamical filtering setup is established for elasticity imaging (i.e., reconstruction of shear modulus distribution) in soft-tissue organs given statically recorded and partially measured displacement data. Unlike a regularized quasi-Newton method (QNM) that needs inversion of ill-con...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3158808

    authors: Banerjee B,Roy D,Vasu RM

    更新日期:2009-08-01 00:00:00

  • Comparison of internal dose estimates obtained using organ-level, voxel S value, and Monte Carlo techniques.

    abstract:PURPOSE:The authors' objective was to compare internal dose estimates obtained using the Organ Level Dose Assessment with Exponential Modeling (OLINDA/EXM) software, the voxel S value technique, and Monte Carlo simulation. Monte Carlo dose estimates were used as the reference standard to assess the impact of patient-sp...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4892606

    authors: Grimes J,Celler A

    更新日期:2014-09-01 00:00:00

  • SU-E-T-382: An Analysis of VMAT Monthly Quality Assurance.

    abstract:PURPOSE:The purpose of this study is to quantify the change in monthly VMAT quality assurance (QA) and determine the tests to maintain consistent delivery with a baseline. METHODS:VMAT monthly QA has been performed for over 14 months on two Elekta Synergy LINACs. A baseline was established at acceptance and the monthl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735470

    authors: Stenbeck J,Oves S,Gebreamlak W,Alkhatib H

    更新日期:2012-06-01 00:00:00

  • Direction modulated brachytherapy (DMBT) for treatment of cervical cancer: A planning study with 192 Ir, 60 Co, and 169 Yb HDR sources.

    abstract:PURPOSE:To evaluate plan quality of a novel MRI-compatible direction modulated brachytherapy (DMBT) tandem applicator using 192 Ir, 60 Co, and 169 Yb HDR brachytherapy sources, for various cervical cancer high-risk clinical target volumes (CTVHR ). MATERIALS AND METHODS:The novel DMBT tandem applicator has six periphe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12598

    authors: Safigholi H,Han DY,Mashouf S,Soliman A,Meigooni AS,Owrangi A,Song WY

    更新日期:2017-12-01 00:00:00

  • Clinical implementation and commissioning of the MedAustron Particle Therapy Accelerator for non-isocentric scanned proton beam treatments.

    abstract:PURPOSE:This paper describes the clinical implementation and medical commissioning of the MedAustron Particle Therapy Accelerator (MAPTA) for non-isocentric scanned proton beam treatments. METHODS:Medical physics involvement during technical commissioning work is presented. Acceptance testing procedures, including adv...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13928

    authors: Grevillot L,Osorio Moreno J,Letellier V,Dreindl R,Elia A,Fuchs H,Carlino A,Kragl G,Palmans H,Vatnitsky S,Stock M

    更新日期:2020-02-01 00:00:00

  • A real time dose monitoring and dose reconstruction tool for patient specific VMAT QA and delivery.

    abstract:PURPOSE:To develop a real time dose monitoring and dose reconstruction tool to identify and quantify sources of errors during patient specific volumetric modulated arc therapy (VMAT) delivery and quality assurance. METHODS:The authors develop a VMAT delivery monitor tool called linac data monitor that connects to the ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4764482

    authors: Tyagi N,Yang K,Gersten D,Yan D

    更新日期:2012-12-01 00:00:00

  • Octavius 4D characterization for flattened and flattening filter free rotational deliveries.

    abstract:PURPOSE:In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans. METHODS:The response o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4817482

    authors: McGarry CK,O'Connell BF,Grattan MW,Agnew CE,Irvine DM,Hounsell AR

    更新日期:2013-09-01 00:00:00

  • Iodine quantification in limited angle tomography.

    abstract:PURPOSE:To develop and test the feasibility of a two-pass iterative reconstruction algorithm with material decomposition designed to obtain quantitative iodine measurements in digital breast tomosynthesis. METHODS:Contrast-enhanced mammography has shown promise as a cost-effective alternative to magnetic resonance ima...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14400

    authors: Michielsen K,Rodríguez-Ruiz A,Reiser I,Nagy JG,Sechopoulos I

    更新日期:2020-10-01 00:00:00

  • Comparisons of treatment optimization directly incorporating systematic patient setup uncertainty with a margin-based approach.

    abstract:PURPOSE:To develop a probabilistic treatment planning (PTP) method which is robust to systematic patient setup errors and to compare PTP plans with plans generated using a planning target volume (PTV) margin optimized to give the same target coverage probability as the PTP plan. METHODS:Plans adhering to the RTOG-0126...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3679856

    authors: Moore JA,Gordon JJ,Anscher M,Silva J,Siebers JV

    更新日期:2012-02-01 00:00:00

  • High dose-per-pulse electron beam dosimetry: Usability and dose-rate independence of EBT3 Gafchromic films.

    abstract:PURPOSE:The aim of this study was to assess the suitability of Gafchromic EBT3 films for reference dose measurements in the beam of a prototype high dose-per-pulse linear accelerator (linac), capable of delivering electron beams with a mean dose-rate (Ḋm ) ranging from 0.07 to 3000 Gy/s and a dose-rate in pulse (Ḋp ) o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12066

    authors: Jaccard M,Petersson K,Buchillier T,Germond JF,Durán MT,Vozenin MC,Bourhis J,Bochud FO,Bailat C

    更新日期:2017-02-01 00:00:00

  • Robust optimization in IMPT using quadratic objective functions to account for the minimum MU constraint.

    abstract:PURPOSE:Currently, in clinical practice of intensity-modulated proton therapy (IMPT), the influence of the minimum monitor unit (MU) constraint is taken into account through postprocessing after the optimization is completed. This may degrade the plan quality and plan robustness. This study aims to mitigate the impact ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12677

    authors: Shan J,An Y,Bues M,Schild SE,Liu W

    更新日期:2018-01-01 00:00:00

  • X-ray imaging with amorphous selenium: optimal spectra for digital mammography.

    abstract::The optimum x-ray spectra for acquisition of digital mammographic images using an amorphous selenium (a-Se) photoconductor are investigated. The recorded images consist of latent charge distributions on the surface of an a-Se plate, which are then read out using two methods, laser discharge, or flat panel recharge. Th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597688

    authors: Fahrig R,Rowlands JA,Yaffe MJ

    更新日期:1996-04-01 00:00:00

  • Differences in the lesion formation process between focused ultrasound and microwave ablations.

    abstract::The objective is to understand the differences in the lesion formation processes between microwave and high-intensity focused ultrasound (HIFU) ablation. The lesions formed by microwaves and HIFU were real-time monitored and compared using transparent tissue-mimicking phantoms at 60 and 70 W of driving electrical powe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2193689

    authors: Chen WS,Wu CC,Fang HY,Liu HL

    更新日期:2006-05-01 00:00:00

  • Development of a silicon diode detector for skin dosimetry in radiotherapy.

    abstract:PURPOSE:The aim of in vivo skin dosimetry was to measure the absorbed dose to the skin during radiotherapy, when treatment planning calculations cannot be relied on. It is of particularly importance in hypo-fractionated stereotactic modalities, where excessive dose can lead to severe skin toxicity. Currently, commercia...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12469

    authors: Vicoroski N,Espinoza A,Duncan M,Oborn BM,Carolan M,Metcalfe P,Menichelli D,Perevertaylo VL,Lerch MLF,Rosenfeld AB,Petasecca M

    更新日期:2017-10-01 00:00:00

  • The x-ray time of flight method for investigation of ghosting in amorphous selenium-based flat panel medical x-ray imagers.

    abstract::Amorphous selenium (a-Se) based real-time flat-panel imagers (FPIs) are finding their way into the digital radiology department because they offer the practical advantages of digital x-ray imaging combined with an image quality that equals or outperforms that of conventional systems. The temporal imaging characteristi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2042248

    authors: Rau AW,Bakueva L,Rowlands JA

    更新日期:2005-10-01 00:00:00

  • Technical Note: Automatic segmentation of CT images for ventral body composition analysis.

    abstract:PURPOSE:Body composition is known to be associated with many diseases including diabetes, cancers, and cardiovascular diseases. In this paper, we developed a fully automatic body tissue decomposition procedure to segment three major compartments that are related to body composition analysis - subcutaneous adipose tissu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14465

    authors: Fu Y,Ippolito JE,Ludwig DR,Nizamuddin R,Li HH,Yang D

    更新日期:2020-11-01 00:00:00

  • A comparative study of rectal dose histograms in prostate brachytherapy: some analytic and numerical results.

    abstract::A cumulative dose histogram is the graph of an integral function integrated over a domain VCR3 and is dubbed the dose-volume histogram (DVH), the dose-surface histogram (DSH) or the dose-wall histogram (DWH), depending on the dimension and structure of the region V. This paper presents a comparative study of the three...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1852811

    authors: Song JS,Albert M,D'Amico AV,Cormack RA

    更新日期:2005-02-01 00:00:00

  • Dose distributions of a proton beam for eye tumor therapy: hybrid pencil-beam ray-tracing calculations.

    abstract::For the case of eye tumor therapy with protons, improvements are introduced compared to the standard dose calculation which implies straight-line optics and the constant-density assumption for the eye and its surrounding. The progress consists of (i) taking account of the lateral scattering of the protons in tissue by...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2168067

    authors: Rethfeldt C,Fuchs H,Gardey KU

    更新日期:2006-03-01 00:00:00