X-ray imaging with amorphous selenium: X-ray to charge conversion gain and avalanche multiplication gain.

Abstract:

:Fluoroscopy is a low dose imaging technique. As such, a very sensitive detector is required to create images of good quality. Present day flat panel active matrix read out systems introduce an amount of noise that inhibits present direct and indirect methods from producing optimal quality images at fluoroscopic exposure rates (0.1-10 microR per frame). The gain of the direct conversion approach using amorphous selenium (a-Se) was investigated to determine whether by increasing the applied electric field, a gain sufficient to overcome the noise limitations of the active matrix could be achieved. Conversion gain and avalanche multiplication in a-Se were investigated as a function of electric field from 10 to 100 V/microm. Our results show a factor of 4 increase in conversion gain is available by increasing electric field from the current standard of 10 V/microm to 100 V/microm. Furthermore, we show that avalanche multiplication can provide an additional gain of up to 25. This increase in signal is sufficient to overcome the noise level encountered in flat panel detectors and permit fully quantum noise limited operation across the whole fluoroscopic range of exposure.

journal_name

Med Phys

journal_title

Medical physics

authors

Hunt DC,Kirby SS,Rowlands JA

doi

10.1118/1.1513157

subject

Has Abstract

pub_date

2002-11-01 00:00:00

pages

2464-71

issue

11

eissn

0094-2405

issn

2473-4209

journal_volume

29

pub_type

杂志文章
  • Postal intercomparison of absorbed dose for high energy x rays with thermoluminescence dosimeters.

    abstract::This study concerns the accuracy and precision of the IAEA/WHO LiF TLD system used in intercomparison by mail of absorbed doses from 60Co gamma-radiation and 4-25 MV x rays. The system employs 160 mg LiF powder in polystyrene capsules, which are placed at 5 or 7 cm depth in water and irradiated to doses close to 200 r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594746

    authors: Bjärngard BE,Kase KR,Rudén BI,Biggs PJ,Boyer AL,Johansson KA

    更新日期:1980-09-01 00:00:00

  • Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain.

    abstract:PURPOSE:The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. METHODS:The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4918321

    authors: Jung JH,Choi Y,Jung J,Kim S,Lim HK,Im KC,Oh CH,Park HW,Kim KM,Kim JG

    更新日期:2015-05-01 00:00:00

  • Simultaneous respiratory motion correction and image reconstruction in 4D-multi pinhole small animal SPECT.

    abstract:PURPOSE:Respiratory motion in the chest region during single photon emission computed tomography (SPECT) is a major degrading factor that reduces the accuracy of image quantification. This effect is more notable when the tumor is very small, or the spatial resolution of the imaging system is less than the respiratory m...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13807

    authors: Naseri M,Rajabi H,Wang J,Abbasi M,Kalantari F

    更新日期:2019-11-01 00:00:00

  • Factors influencing the performance of patient specific quality assurance for pencil beam scanning IMPT fields.

    abstract:PURPOSE:A detailed analysis of 2728 intensity modulated proton therapy (IMPT) fields that were clinically delivered to patients between 2007 and 2013 at Paul Scherrer Institute (PSI) was performed. The aim of this study was to analyze the results of patient specific dosimetric verifications and to assess possible corre...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4964449

    authors: Trnková P,Bolsi A,Albertini F,Weber DC,Lomax AJ

    更新日期:2016-11-01 00:00:00

  • Classifier performance prediction for computer-aided diagnosis using a limited dataset.

    abstract::In a practical classifier design problem, the true population is generally unknown and the available sample is finite-sized. A common approach is to use a resampling technique to estimate the performance of the classifier that will be trained with the available sample. We conducted a Monte Carlo simulation study to co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2868757

    authors: Sahiner B,Chan HP,Hadjiiski L

    更新日期:2008-04-01 00:00:00

  • A Monte Carlo comparison of the response of the PTW-diamond and the TL-diamond detectors in megavoltage photon beams.

    abstract::A detailed Monte Carlo study of the PTW-diamond solid state detector response in megavoltage photon beams (60Co gamma rays to 25 MV x rays) has been performed with the EGS4 Monte Carlo Code. The sensitive volume of the diamond detector is a disk of diameter 4.4 mm and thickness 0.40 mm. The phantom material was water ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598771

    authors: Mobit PN,Sandison GA

    更新日期:1999-11-01 00:00:00

  • SU-E-T-267: Construction and Evaluation of a Neutron Wall to Shield a 15 MV Linac in a Low-Energy Vault.

    abstract:PURPOSE:To design and quantify the shielding efficacy of an inner Borated Polyethylene (BPE)wall for a 15 MV linac in a low energy vault. METHODS:A Varian TrueBeam linac with a maximum photon energy of 15 MV was installed in asmaller, preexisting vault. This vault originally housed a low-energy machine and did not hav...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735334

    authors: Speiser M,Hager F,Foster R,Solberg T

    更新日期:2012-06-01 00:00:00

  • Analysis of Fourier-domain task-based detectability index in tomosynthesis and cone-beam CT in relation to human observer performance.

    abstract:PURPOSE:Design and optimization of medical imaging systems benefit from accurate theoretical modeling that identifies the physical factors governing image quality, particularly in the early stages of system development. This work extends Fourier metrics of imaging performance and detectability index (d') to tomosynthes...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3560428

    authors: Gang GJ,Lee J,Stayman JW,Tward DJ,Zbijewski W,Prince JL,Siewerdsen JH

    更新日期:2011-04-01 00:00:00

  • Accounting for the fringe magnetic field from the bending magnet in a Monte Carlo accelerator treatment head simulation.

    abstract:PURPOSE:Monte Carlo (MC) simulation can be used for accurate electron beam treatment planning and modeling. Measurement of large electron fields, with the applicator removed and secondary collimator wide open, has been shown to provide accurate simulation parameters, including asymmetry in the measured dose, for the fu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3592640

    authors: O'Shea TP,Foley MJ,Faddegon BA

    更新日期:2011-06-01 00:00:00

  • Quantitative study of focused ultrasound enhanced doxorubicin delivery to prostate tumor in vivo with MRI guidance.

    abstract:PURPOSE:The purpose of this study was to investigate the potential of MR-guided pulsed focused ultrasound (pFUS) for the enhancement of drug uptake in prostate tumors in vivo using doxorubicin (Dox). METHODS:An antitumor drug Dox, an orthotopic animal prostate tumor model using human prostate cancer, LNCaP cell line, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4705346

    authors: Chen X,Cvetkovic D,Ma CM,Chen L

    更新日期:2012-05-01 00:00:00

  • Calibration of 192Ir high-dose-rate afterloading systems.

    abstract::A method is described for calibration of 192Ir high-dose-rate (HDR) brachytherapy afterloading systems. Since NIST does not offer calibration of ionization chambers with the gamma-ray spectrum of iridium-192, an interpolation procedure is employed, using calibrations above (137Cs, 662 keV) and below (250 kVcp, 146-keV...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596649

    authors: Goetsch SJ,Attix FH,Pearson DW,Thomadsen BR

    更新日期:1991-05-01 00:00:00

  • Accuracy of EGSnrc calculations at 60Co energies for the response of ion chambers configured with various wall materials and cavity dimensions.

    abstract::In this investigation, five experimental data sets are used to evaluate the ability of the EGSnrc Monte Carlo code to calculate the change in chamber response associated with changes in wall material and cavity dimension at 60Co energies. Calculations of the ratios of response per unit mass of air as a function of cav...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3013701

    authors: La Russa DJ,Rogers DW

    更新日期:2008-12-01 00:00:00

  • Computational modeling of 915 MHz microwave ablation: Comparative assessment of temperature-dependent tissue dielectric models.

    abstract:PURPOSE:The objective of this study is to develop a computational model for simulating 915 MHz microwave ablation (MWA), and verify the simulation predictions of transient temperature profiles against experimental measurements. Due to the limited experimental data characterizing temperature-dependent changes of tissue ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12359

    authors: Deshazer G,Hagmann M,Merck D,Sebek J,Moore KB,Prakash P

    更新日期:2017-09-01 00:00:00

  • Automatic quantitative low contrast analysis of digital chest phantom radiographs.

    abstract::Up to the present, the majority of low contrast object evaluations performed on phantom images have been accomplished in a subjective fashion. This is mainly due to the time and effort required to manually measure each radiograph with a densitometer to obtain quantitative results. However, with the development of digi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1543153

    authors: Kwan AL,Filipow LJ,Le LH

    更新日期:2003-03-01 00:00:00

  • Intensity-modulation radiotherapy using independent collimators: an algorithm study.

    abstract::The purpose of this work is to investigate algorithms for the delivery of intensity-modulated fields using independent collimators (IC). Two heuristic algorithms are proposed to calculate jaw-setting sequences for arbitrary 2D intensity distributions. The first algorithm is based on searching the whole intensity matri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598794

    authors: Dai JR,Hu YM

    更新日期:1999-12-01 00:00:00

  • Radiofrequency transmit calibration: A multi-center evaluation of vendor-provided radiofrequency transmit mapping methods.

    abstract:PURPOSE:To determine the accuracy and test-retest repeatability of fast radiofrequency (RF) transmit measurement approaches used in Dynamic Contrast Enhanced Magnetic Resonance Imaging (DCE-MRI). Spatial variation in the transmitted RF field introduces bias and increased variance in quantitative DCE-MRI metrics includi...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1002/mp.13518

    authors: Bliesener Y,Zhong X,Guo Y,Boss M,Bosca R,Laue H,Chung C,Sung K,Nayak KS

    更新日期:2019-06-01 00:00:00

  • Characteristics of sensitometric curves of radiographic films.

    abstract::A new type of radiographic film, EDR (extended dose range) film, has been recently become available for film dosimetry. It is particularly attractive for composite isodose verification of intensity modulated radiation therapy because of its low sensitivity relative to the more common Kodak XV film. For XV film, the re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1568979

    authors: Zhu XR,Yoo S,Jursinic PA,Grimm DF,Lopez F,Rownd JJ,Gillin MT

    更新日期:2003-05-01 00:00:00

  • A quality assurance program for monitor unit calculators.

    abstract::A quality assurance protocol has been developed to assess the relative accuracy of computerized monitor unit calculations. Results from this testing reveal that errors (defined as the difference between the computer results and those obtained using a standard formula with manual calculation) in monitor unit calculator...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596539

    authors: Dahl RA,McCullough EC,Mellenberg DE

    更新日期:1990-01-01 00:00:00

  • The effect of pitch in multislice spiral/helical CT.

    abstract::The purpose of this study is to understand the effect of pitch on raw data interpolation in multislice spiral/helical computed tomography (CT) and provide guidelines for scanner design and protocol optimization. Multislice spiral CT is mainly characterized by the three parameters: the number of detector arrays, the de...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598804

    authors: Wang G,Vannier MW

    更新日期:1999-12-01 00:00:00

  • Introduction of a novel dose saving acquisition mode for the PortalVision aS500 EPID to facilitate on-line patient setup verification.

    abstract::In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1668391

    authors: Vetterli D,Riem H,Aebersold DM,Greiner RH,Manser P,Cossmann P,Kemmerling L,Born EJ,Mini R

    更新日期:2004-04-01 00:00:00

  • Cascaded-systems analyses and the detective quantum efficiency of single-Z x-ray detectors including photoelectric, coherent and incoherent interactions.

    abstract:PURPOSE:Theoretical models of the detective quantum efficiency (DQE) of x-ray detectors are an important step in new detector development by providing an understanding of performance limitations and benchmarks. Previous cascaded-systems analysis (CSA) models accounted for photoelectric interactions only. This paper des...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4794495

    authors: Yun S,Tanguay J,Kim HK,Cunningham IA

    更新日期:2013-04-01 00:00:00

  • Photon attenuation in computed tomography.

    abstract::The analysis and understanding of results of computed tomography (CT) require an understanding of photon attenuation in matter. The high sensitivity and resolution of these devices coupled with the use of a polychromatic photon source require a level and breadth of understanding about photon attenuation not usually re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594199

    authors: McCullough EC

    更新日期:1975-11-01 00:00:00

  • A quality management program in intravascular brachytherapy.

    abstract::While simple, intravascular brachytherapy (IVB) presents a considerable potential for harm to the patient. The medical physicist maintains the responsibility to minimize the likelihood of operational problems or dosimetric errors. The principals for safe operation remain the same as with any radiotherapy treatment: to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1524167

    authors: Chakri A,Thomadsen B

    更新日期:2002-12-01 00:00:00

  • The use of PET images for radiotherapy treatment planning: an error analysis using radiobiological endpoints.

    abstract:PURPOSE:There is significant current interest in the use of biological image guidance in radiotherapy planning. In lung-cancer treatment, tumor motion due to respiration is known to be a limitation. This is particularly true in PET, where image data are collected over a number of minutes. An in-house-developed 4D PET a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3276776

    authors: Perrin R,Evans PM,Webb S,Partridge M

    更新日期:2010-02-01 00:00:00

  • Fast reconstruction with uniform noise properties in halfscan computed tomography.

    abstract::The hybrid algorithms developed recently for the reconstruction of fan-beam images possess computational and noise properties superior to those of the fan-beam filtered backprojection (FFBP) algorithm. However, the hybrid algorithms cannot be applied directly to a halfscan fan-beam sinogram because they require knowle...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1288239

    authors: Pan X

    更新日期:2000-09-01 00:00:00

  • Biomechanical modeling constrained surface-based image registration for prostate MR guided TRUS biopsy.

    abstract:PURPOSE:Adding magnetic resonance (MR)-derived information to standard transrectal ultrasound (TRUS) images for guiding prostate biopsy is of substantial clinical interest. A tumor visible on MR images can be projected on ultrasound (US) by using MR-US registration. A common approach is to use surface-based registratio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4917481

    authors: van de Ven WJ,Hu Y,Barentsz JO,Karssemeijer N,Barratt D,Huisman HJ

    更新日期:2015-05-01 00:00:00

  • A Monte Carlo study on the collimation of pencil beam scanning proton therapy beams.

    abstract:PURPOSE:The lateral edge of a proton therapy beam is commonly used to achieve conformality to the treatment volume where critical structures reside close to the target. However, when treating shallow depths, the lateral edge of a pencil beam scanning (PBS) system may be broader than that of a double scattered (DS) syst...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4941957

    authors: Charlwood FC,Aitkenhead AH,Mackay RI

    更新日期:2016-03-01 00:00:00

  • Validation of GPU-accelerated superposition-convolution dose computations for the Small Animal Radiation Research Platform.

    abstract:PURPOSE:The Small Animal Radiation Research Platform (SARRP) has been developed for conformal microirradiation with on-board cone beam CT (CBCT) guidance. The graphics processing unit (GPU)-accelerated Superposition-Convolution (SC) method for dose computation has been integrated into the treatment planning system (TPS...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12862

    authors: Cho N,Tsiamas P,Velarde E,Tryggestad E,Jacques R,Berbeco R,McNutt T,Kazanzides P,Wong J

    更新日期:2018-05-01 00:00:00

  • SU-E-T-118: Characterization of EBT3 Films in Photon and Proton Beams.

    abstract:PURPOSE:To measure the calibration curves of EBT3 dosimetry films in photon and proton beams and to quantify the related uncertainties from one beam type to another. METHODS:EBT3 Gafchromic films have similar properties than EBT2 with a symmetric construction and a matte polyester substrate to prevent Newton's ring ar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735176

    authors: Sorriaux J,Rossomme S,Kacperek A,Bertrand D,Vynckier S,Sterpin E

    更新日期:2012-06-01 00:00:00

  • Evaluation of dual energy quantitative CT for determining the spatial distributions of red marrow and bone for dosimetry in internal emitter radiation therapy.

    abstract:PURPOSE:To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy. METHODS:The DEQCT method was applied to 80/140 kVp images of patient-simulating lumb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4870378

    authors: Goodsitt MM,Shenoy A,Shen J,Howard D,Schipper MJ,Wilderman S,Christodoulou E,Chun SY,Dewaraja YK

    更新日期:2014-05-01 00:00:00