Accuracy of EGSnrc calculations at 60Co energies for the response of ion chambers configured with various wall materials and cavity dimensions.

Abstract:

:In this investigation, five experimental data sets are used to evaluate the ability of the EGSnrc Monte Carlo code to calculate the change in chamber response associated with changes in wall material and cavity dimension at 60Co energies. Calculations of the ratios of response per unit mass of air as a function of cavity volume for walls ranging from polystyrene to lead are generally within 1%-3% of experiments. A few exceptions, which are discussed, include 20%-30% discrepancies with experiments involving lead-walled chambers used by Attix et al. [J. Res. Natl. Bur. Stand. 60, 235-243 (1958)] and Cormack and Johns [Radiat. Res. 1, 133-157 (1954)], and 5% discrepancies for the graphite chamber of Attix et al. (relative to data for other wall materials). Simulations of the experiment by Whyte [Radiat. Res. 6, 371-379 (1957)], which varied cavity air pressure in a large cylindrical chamber, are generally within 0.5% (wall/electrode materials ranging from beryllium to copper). In all cases, the agreement between measurements and EGSnrc calculations is much better when the response as a function of cavity height or air pressure is considered for each wall material individually. High-precision measurements [Burns et al., Phys. Med. Biol. 52, 7125-7135 (2007)] of the response per unit mass as a function of cavity height for a graphite chamber are also accurately reproduced, and validate previous tests of the transport mechanics of EGSnrc. Based on the general agreement found in this work between corresponding experimental results and EGSnrc calculations it can be concluded that EGSnrc can reliably be used to calculate changes in response with changes in various wall materials and cavity dimensions at 60Co energies within a accuracy of a few percent or less.

journal_name

Med Phys

journal_title

Medical physics

authors

La Russa DJ,Rogers DW

doi

10.1118/1.3013701

subject

Has Abstract

pub_date

2008-12-01 00:00:00

pages

5629-40

issue

12

eissn

0094-2405

issn

2473-4209

journal_volume

35

pub_type

杂志文章
  • A study of effective attenuation coefficient for calculating tissue compensator thickness.

    abstract::Dose uniformity throughout the treatment volume is essential to precision radiation therapy. Tissue compensators are often used as a means to eliminate dose nonuniformity resulting from surface contour irregularities. This paper evaluates the accuracy of using an effective attenuation coefficient for calculating the t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596561

    authors: Bagne FR,Samsami N,Hoke SW,Bronn DG

    更新日期:1990-01-01 00:00:00

  • Computation of energy imparted in diagnostic radiology.

    abstract::Energy imparted is a measure of the total ionizing energy deposited in the patient during a radiologic examination and may be used to quantify the patient dose in diagnostic radiology. Values of the energy imparted per unit exposure-area product, omega (z), absorbed by a semi-infinite water phantom with a thickness z,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597939

    authors: Gkanatsios NA,Huda W

    更新日期:1997-04-01 00:00:00

  • Novel detector design for reducing intercell x-ray cross-talk in the variable resolution x-ray CT scanner: a Monte Carlo study.

    abstract:PURPOSE:The variable resolution x-ray (VRX) CT scanner provides substantial improvement in the spatial resolution by matching the scanner's field of view (FOV) to the size of the object being imaged. Intercell x-ray cross-talk is one of the most important factors limiting the spatial resolution of the VRX detector. In ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3555035

    authors: Arabi H,Asl AR,Ay MR,Zaidi H

    更新日期:2011-03-01 00:00:00

  • A moving slanted-edge method to measure the temporal modulation transfer function of fluoroscopic systems.

    abstract::Lag in fluoroscopic systems introduces a frame-averaging effect that reduces measurements of image noise and incorrectly inflates measurements of the detective quantum efficiency (DQE). A correction can be implemented based on measurements of the temporal modulation transfer function (MTF). We introduce a method of me...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2919724

    authors: Friedman SN,Cunningham IA

    更新日期:2008-06-01 00:00:00

  • Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging.

    abstract:PURPOSE:The possible clinical applications which can be performed using a newly developed detector depend on the detector's characteristic performance in a number of metrics including the dynamic range, resolution, uniformity, and stability. The authors have evaluated a prototype energy resolved fast photon counting x-...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4892174

    authors: Cho HM,Barber WC,Ding H,Iwanczyk JS,Molloi S

    更新日期:2014-09-01 00:00:00

  • L-curve analysis of radiotherapy optimization problems.

    abstract::We attempt to select an optimal value of regularization parameter in the optimization problems for intensity-modulated radiotherapy which are solved using a variational regularization technique. We apply to inverse treatment planning the L-curve method which was developed to determine the regularization parameter in t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1949750

    authors: Chvetsov AV

    更新日期:2005-08-01 00:00:00

  • Feasibility of a simple method of hybrid collimation for megavoltage grid therapy.

    abstract:PURPOSE:Megavoltage grid therapy is currently delivered with step-and-shoot multisegment techniques or using a high attenuation block with divergent holes. However, the commercial availability of grid blocks is limited, their construction is difficult, and step-and-shoot techniques require longer treatment times and ar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4801902

    authors: Almendral P,Mancha PJ,Roberto D

    更新日期:2013-05-01 00:00:00

  • Dynamic multiatlas selection-based consensus segmentation of head and neck structures from CT images.

    abstract:PURPOSE:Manual delineation of head and neck (H&N) organ-at-risk (OAR) structures for radiation therapy planning is time consuming and highly variable. Therefore, we developed a dynamic multiatlas selection-based approach for fast and reproducible segmentation. METHODS:Our approach dynamically selects and weights the a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13854

    authors: Haq R,Berry SL,Deasy JO,Hunt M,Veeraraghavan H

    更新日期:2019-12-01 00:00:00

  • SU-E-J-170: Clinical Evaluation of Positioning Accuracy of Two Immobilization Devices for Stereotactic Body Radiotherapy Using Cone Beam CT.

    abstract:PURPOSE:To evaluate the patient positioning accuracy and reproducibility of two commercially available immobilization systems for Stereotactic Body Radiotherapy (SBRT) treatment. METHODS:Forty one patients with lung (n=21) or liver (n=20) malignancies were assigned to one of the two immobilization devices: Elekta ster...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735009

    authors: Cao M,Cao N,Cardenes H,Fakiris A,Desrosiers C,Das I

    更新日期:2012-06-01 00:00:00

  • Experimental test of theoretical models for time-resolved reflectance.

    abstract::Four different expressions, derived from the diffusion theory or the random walk model, were used to fit time-resolved reflectance data for the evaluation of tissue optical properties. The experimental reflectance curves were obtained from phantoms of known optical parameters (absorption and transport scattering coeff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597739

    authors: Cubeddu R,Pifferi A,Taroni P,Torricelli A,Valentini G

    更新日期:1996-09-01 00:00:00

  • Radionuclide photon dose kernels for internal emitter dosimetry.

    abstract::Photon point dose kernels and absorbed fractions were generated in water for the full photon emission spectrum of each radionuclide of interest in nuclear medicine, by simulating the transport of particles using Monte Carlo. The kernels were then fitted to a mathematical expression. Absorbed fractions for point source...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597670

    authors: Furhang EE,Sgouros G,Chui CS

    更新日期:1996-05-01 00:00:00

  • Calculating output factors for photon beam radiotherapy using a convolution/superposition method based on a dual source photon beam model.

    abstract::A realistic photon beam model based on Monte Carlo simulation of clinical linear accelerators was implemented in a convolution/superposition dose calculation algorithm. A primary and an extra-focal sources were used in this beam model to represent the direct photons from the target and the scattered photons from other...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598111

    authors: Liu HH,Mackie TR,McCullough EC

    更新日期:1997-12-01 00:00:00

  • Evaluation of a commercial MRI Linac based Monte Carlo dose calculation algorithm with GEANT4.

    abstract:PURPOSE:This paper provides a comparison between a fast, commercial, in-patient Monte Carlo dose calculation algorithm (GPUMCD) and geant4. It also evaluates the dosimetric impact of the application of an external 1.5 T magnetic field. METHODS:A stand-alone version of the Elekta™ GPUMCD algorithm, to be used within th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4939808

    authors: Ahmad SB,Sarfehnia A,Paudel MR,Kim A,Hissoiny S,Sahgal A,Keller B

    更新日期:2016-02-01 00:00:00

  • Small-field electron dosimetry for the Philips SL25 linear accelerator.

    abstract::Electron-beam characteristics of a Philips SL25 linear accelerator have been studied. Central-axis percentage depth doses, cross-beam profiles and beam output factors of 6-, 10-, and 20-MeV beams, selected from the available energy range of 4 to 22 MeV, are reported in this paper. The main thrust of this work is to de...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596471

    authors: Rashid H,Islam MK,Gaballa H,Rosenow UF,Ting JY

    更新日期:1990-07-01 00:00:00

  • An automated dosimetry data-acquisition and analysis system at the LAMPF pion therapy facility.

    abstract::An automated data-acquisition and analysis system has been developed for dosimetry measurements on the pion therapy beam at the Clinton P. Anderson Meson Physics Facility Biomedical Channel in Los Alamos using a PDP-11/45 computer and CAMAC interface. Initialization, test, and monitor programs allow the user to set th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594418

    authors: Rosen I,Smith A,Lane R,Kelsey C,Lake D,Hogstrom K,Somers J,Helland J,Kittell R,Amols H,Bradbury J,Richman C

    更新日期:1978-03-01 00:00:00

  • Dead time of an anger camera in dual-energy-window-acquisition mode.

    abstract::Two side-by-side energy windows are sometimes employed in quantitative single photon emission computed tomography (SPECT) studies. The count-rate losses at high activities for a GE400AT camera were measured in such a dual-window-acquisition mode by imaging a decaying source composed of a hot sphere within a warm cylin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597008

    authors: Zasadny KR,Koral KF,Swailem FM

    更新日期:1993-07-01 00:00:00

  • Unwanted radiation produced by leakage neutrons from medical electron accelerators.

    abstract::Monte Carlo calculations have been made to determine the energy delivered to a phantom by neutrons escaping from the head of a Varian Clinac 35 medical accelerator at an SSD of 1 m. The energy was sorted into two regions: inside and outside a volume defined by a circular beam of area 100 and 600 cm2. For the two beam ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595067

    authors: Ing H,Shore RA

    更新日期:1982-01-01 00:00:00

  • SU-E-T-07: Edema Induced Changes in Tumor Cell Survival Fraction and Tumor Control Probability in 131Cs Permanent Prostate Implant Patients.

    abstract:PURPOSE:The purpose of this study is to estimate the effect of edema, developed during implant procedure, on tumor cell surviving fraction(SF) and tumor control probability(TCP) in the patients of prostate cancer who underwent 131 Cs permanent seed implants. METHODS:The impact of edema on SF and TCP, was calculated us...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735061

    authors: Kehwar TS,Huq MS,Smith RP

    更新日期:2012-06-01 00:00:00

  • Tomosynthesis-based localization of radioactive seeds in prostate brachytherapy.

    abstract::Accurately assessing the quality of prostate brachytherapy intraoperatively would be valuable for improved clinical outcome by ensuring the delivery of a prescribed tumoricidal radiation dose to the entire prostate gland. One necessary step towards this goal is the robust and rapid localization of implanted seeds. Sev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1624755

    authors: Tutar IB,Managuli R,Shamdasani V,Cho PS,Pathak SD,Kim Y

    更新日期:2003-12-01 00:00:00

  • Registration of clinical volumes to beams-eye-view images for real-time tracking.

    abstract:PURPOSE:The authors combine the registration of 2D beam's eye view (BEV) images and 3D planning computed tomography (CT) images, with relative, markerless tumor tracking to provide automatic absolute tracking of physician defined volumes such as the gross tumor volume (GTV). METHODS:During treatment of lung SBRT cases...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4900603

    authors: Bryant JH,Rottmann J,Lewis JH,Mishra P,Keall PJ,Berbeco RI

    更新日期:2014-12-01 00:00:00

  • SU-E-T-302: A Simulation Study with Geant4 Investigating the Secondary Prompt Gamma Emissions from Incident 40 MeV Protons Onto Various Materials.

    abstract:PURPOSE:This study aims to investigate the prompt secondary gamma spectrum and thedepth-dose distributions of incident 40 MeV protons onto various phantom materials.The goal is to find a relationship between the secondary prompt gamma emissions andthe range of the incident particles. METHODS:An application was constru...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735388

    authors: Lau A,Chen Y,Ahmad S

    更新日期:2012-06-01 00:00:00

  • An accurate method for direct dual-energy calibration and decomposition.

    abstract::We propose the use of conic and cubic surface equations (surfaces of second and third order) to directly approximate the dual-energy equations (the integral equations for the dual-energy log-signal functions, i.e., the negative logarithms of the relative detector signals, considered as functions of the basis-material ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596512

    authors: Cardinal HN,Fenster A

    更新日期:1990-05-01 00:00:00

  • SU-E-T-485: Validation of Acuros XB Dose Calculations in SBRT Lung Planning with Monte Carlo Methods.

    abstract:PURPOSE:The Acuros XB (AXB) Advanced Dose algorithm (Varian Medical Systems) represents a dramatic shift in clinical photon dose calculation methodology from pencil-beam superposition/convolution methods. Early studies evaluating the accuracy of the algorithm in lung have found good agreement with both measurement and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735574

    authors: Bush K,Wang L,Mok E

    更新日期:2012-06-01 00:00:00

  • Controlled mold geometry for surgical deficit treatment planning.

    abstract::The relatively precise placement of brachytherapy sources afforded by stereotactic frames for brain implants is not generally achievable for other sites, which lack the fixed geometry of the cranium and its contents. An exception is a source-containing rigid mold that delivers brachytherapy when inserted securely in a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597454

    authors: Anderson LL,Zlotolow IM,McCormick B,Harrison LB

    更新日期:1995-03-01 00:00:00

  • Reliability of water proton chemical shift temperature calibration for focused ultrasound ablation therapy.

    abstract::Our purpose in this work was to assess the reliability of the calibration coefficient for magnetic resonance water proton chemical shift temperature mapping. Over a six month period, the calibration coefficient was measured 15 times in several different phantoms. A highly linear relationship between water proton chemi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598864

    authors: Wu T,Kendell KR,Felmlee JP,Lewis BD,Ehman RL

    更新日期:2000-01-01 00:00:00

  • A method to estimate transmission profiles of bow-tie filters using rotating tube measurements.

    abstract:PURPOSE:The purpose of this paper was to present a method of determining the dose profile of the beam bow-tie filter (BTF) without the need for fixing the x ray tube in a position or using special instruments or dosimeters other than the ordinary types of ion chambers used for CT dosimetry (e.g., Farmer chamber). METH...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13203

    authors: Al-Senan R

    更新日期:2018-11-01 00:00:00

  • Diffuse-diffuse photon coupling via nonscattering void in the presence of refractive index mismatch on the void boundary.

    abstract::It is well established that the diffusion approximation (DA) is valid for light propagation in highly scattering media, but it breaks down in nonscattering void regions. The methods that handle the void with refractive index matched boundary were previously developed. For the void with refractive index mismatched boun...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1766418

    authors: Lee JH,Kim S,Kim YT

    更新日期:2004-08-01 00:00:00

  • Analytic microdosimetry for radioimmunotherapeutic alpha emitters.

    abstract::Analytic microdosimetry using Fourier transform techniques has been applied to internal alpha emitters. These techniques need revision and simplification for use with short-lived radionuclides such as those which may be useful for radioimmunotherapy. Analytic methods may have advantages over Monte Carlo methods in som...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596770

    authors: Stinchcomb TG,Roeske JC

    更新日期:1992-11-01 00:00:00

  • A limit on dose reduction possible with CT reconstruction algorithms without prior knowledge of the scan subject.

    abstract:PURPOSE:To find an upper bound on the maximum dose reduction possible for any reconstruction algorithm, analytic or iterative, that result from the inclusion of the data statistics. The authors do not analyze noise reduction possible from prior knowledge or assumptions about the object. METHODS:The authors examined th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4941954

    authors: Hsieh SS,Chesler DA,Fleischmann D,Pelc NJ

    更新日期:2016-03-01 00:00:00

  • A dose-point-kernel model for a low energy gamma-emitting stent in a heterogeneous medium.

    abstract::A computer dose model for a low energy gamma-emitting stent in a heterogeneous medium is described. The method is based on the Sievert model which is adapted to the dose-point-kernel (DPK) model to compute the dose distribution about filtered gamma sources (Sievert-DPK model). The new gamma stent model can take into a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1380214

    authors: Janicki C,Duggan DM,Rahdert DA

    更新日期:2001-07-01 00:00:00