A quality management program in intravascular brachytherapy.

Abstract:

:While simple, intravascular brachytherapy (IVB) presents a considerable potential for harm to the patient. The medical physicist maintains the responsibility to minimize the likelihood of operational problems or dosimetric errors. The principals for safe operation remain the same as with any radiotherapy treatment: to deliver the correct dose, to the correct location, safety. To develop an effective and comprehensive quality management (QM) program for IVB, a physicist should utilize proven risk assessment techniques rather than simply thinking of things to check, and follow guidances such as ISO9001:2000. The proposed QM program includes the following: Procedures designed to assure the safety of the patient. Identification of the patient; tests of the integrity and patency for the delivery catheter, operation of the source train, and patency of the catheter in the treatment position; a check for recovery preparations; and verification of source recovery. Procedures to assure positional accuracy of the treatment: Verification of the positioning the catheter in the artery and of the sources in the catheter. Procedures to assure dosimetry accuracy: Acceptance testing of the device, including verification of the source strength and uniformity, and of the treatment duration tables; verification of the treatment prescription and duration for each patient; and control measures that minimize the likelihood of errors removing the source at the correct time.

journal_name

Med Phys

journal_title

Medical physics

authors

Chakri A,Thomadsen B

doi

10.1118/1.1524167

subject

Has Abstract

pub_date

2002-12-01 00:00:00

pages

2850-60

issue

12

eissn

0094-2405

issn

2473-4209

journal_volume

29

pub_type

杂志文章
  • Magnetic resonance and ultrasound image-guided navigation system using a needle manipulator.

    abstract:PURPOSE:Image guidance is crucial for percutaneous tumor ablations, enabling accurate needle-like applicator placement into target tumors while avoiding tissues that are sensitive to injury and/or correcting needle deflection. Although ultrasound (US) is widely used for image guidance, magnetic resonance (MR) is prefer...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13958

    authors: Yamada A,Tokuda J,Naka S,Murakami K,Tani T,Morikawa S

    更新日期:2020-03-01 00:00:00

  • Measurement of dose distributions using film in therapeutic electron beams.

    abstract::The feasibility of using film dosimetry data as the input data for patient treatment planning was evaluated. The central-axis depth dose and the off-axis ratios obtained from film measurements in a solid phantom were compared with those of ion-chamber measurements in water. Two techniques were used to generate isodose...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596409

    authors: Shiu AS,Otte VA,Hogstrom KR

    更新日期:1989-11-01 00:00:00

  • Multipinhole collimator with 20 apertures for a brain SPECT application.

    abstract:PURPOSE:Several new technologies for single photon emission computed tomography (SPECT) instrumentation with parallel-hole collimation have been proposed to improve detector sensitivity and signal collection efficiency. Benefits from improved signal efficiency include shorter acquisition times and lower dose requiremen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4897567

    authors: Lee TC,Ellin JR,Huang Q,Shrestha U,Gullberg GT,Seo Y

    更新日期:2014-11-01 00:00:00

  • Elements of microdosimetry.

    abstract::This is an introductory tutorial to the field of microdosimetry. Following a brief historical outline, we review the physics of experimental and theoretical microdosimetry and the application of microdosimetry to radiation biology within the so-called "site" approximation. Modern interpretations of microdosimetry that...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.596616

    authors: Rossi HH,Zaider M

    更新日期:1991-11-01 00:00:00

  • Scanned-projection digital mammography.

    abstract::The effectiveness of film-screen mammography is limited by tradeoffs between latitude and contrast, film granularity, and the need to increase dose when antiscatter methods are used. We are currently developing a scanned-projection digital mammography (SPDM) system to overcome these limitations. The system consists of...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596147

    authors: Nishikawa RM,Mawdsley GE,Fenster A,Yaffe MJ

    更新日期:1987-09-01 00:00:00

  • An automated dosimetry data-acquisition and analysis system at the LAMPF pion therapy facility.

    abstract::An automated data-acquisition and analysis system has been developed for dosimetry measurements on the pion therapy beam at the Clinton P. Anderson Meson Physics Facility Biomedical Channel in Los Alamos using a PDP-11/45 computer and CAMAC interface. Initialization, test, and monitor programs allow the user to set th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594418

    authors: Rosen I,Smith A,Lane R,Kelsey C,Lake D,Hogstrom K,Somers J,Helland J,Kittell R,Amols H,Bradbury J,Richman C

    更新日期:1978-03-01 00:00:00

  • SAPHIRE (scintillator avalanche photoconductor with high resolution emitter readout) for low dose x-ray imaging: spatial resolution.

    abstract::An indirect flat panel imager (FPI) with programmable avalanche gain and field emitter array (FEA) readout is being investigated for low-dose and high resolution x-ray imaging. It is made by optically coupling a structured x-ray scintillator, e.g., thallium (Tl) doped cesium iodide (CsI), to an amorphous selenium (a-S...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2937652

    authors: Li D,Zhao W

    更新日期:2008-07-01 00:00:00

  • Task Group 284 Report: Magnetic Resonance Imaging Simulation in Radiotherapy: Considerations for Clinical Implementation, Optimization, and Quality Assurance.

    abstract::The use of dedicated magnetic resonance simulation (MR-SIM) platforms in Radiation Oncology has expanded rapidly, introducing new equipment and functionality with the overall goal of improving the accuracy of radiation treatment planning. However, this emerging technology presents a new set of challenges that need to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14695

    authors: Glide-Hurst CK,Paulson ES,McGee K,Tyagi N,Hu Y,Balter J,Bayouth J

    更新日期:2021-01-01 00:00:00

  • Reverse mapping of normal tissue complication probabilities onto dose volume histogram space: the problem of randomness of the dose volume histogram sampling.

    abstract::A very important issue in contemporary inverse treatment radiotherapy planning is the specification of proper dose-volume constraints limiting the treatment planning algorithm from delivering high doses to the normal tissue surrounding the tumor. Recently we have proposed a method called reverse mapping of normal tiss...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2198307

    authors: Markov K,Schinkel C,Stavreva N,Stavrev P,Weldon M,Fallone BG

    更新日期:2006-09-01 00:00:00

  • DMLC tracking and gating can improve dose coverage for prostate VMAT.

    abstract:PURPOSE:To assess and compare the dosimetric impact of dynamic multileaf collimator (DMLC) tracking and gating as motion correction strategies to account for intrafraction motion during conventionally fractionated prostate radiotherapy. METHODS:A dose reconstruction method was used to retrospectively assess the dose d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4892605

    authors: Colvill E,Poulsen PR,Booth JT,O'Brien RT,Ng JA,Keall PJ

    更新日期:2014-09-01 00:00:00

  • Intensity inhomogeneity correction for magnetic resonance imaging of human brain at 7T.

    abstract:PURPOSE:To evaluate the performance and efficacy for intensity inhomogeneity correction of various sequences of the human brain in 7T MRI using the extended version of the unified segmentation algorithm. MATERIALS:Ten healthy volunteers were scanned with four different sequences (2D spin echo [SE], 3D fast SE, 2D fast...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4860954

    authors: Uwano I,Kudo K,Yamashita F,Goodwin J,Higuchi S,Ito K,Harada T,Ogawa A,Sasaki M

    更新日期:2014-02-01 00:00:00

  • Noise in stenosis measurement using digital subtraction angiography.

    abstract::This paper examines statistical errors in the measurement of arterial stenoses by digital videodensitometry. Images of vessel phantoms were acquired using digital subtraction angiographic techniques with low concentrations of an iodine contrast medium and low levels of x-ray exposure. Effects of the spatial and tempor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595652

    authors: Wright GA,Taylor KW,Rowlands JA

    更新日期:1985-11-01 00:00:00

  • A Dirichlet process mixture model for automatic (18)F-FDG PET image segmentation: Validation study on phantoms and on lung and esophageal lesions.

    abstract:PURPOSE:The aim of this study was to implement a Dirichlet process mixture (DPM) model for automatic tumor edge identification on (18)F-fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) images by optimizing the parameters on which the algorithm depends, to validate it experimentally, and to test its robus...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4947123

    authors: Giri MG,Cavedon C,Mazzarotto R,Ferdeghini M

    更新日期:2016-05-01 00:00:00

  • Evaluation of three types of reference image data for external beam radiotherapy target localization using digital tomosynthesis (DTS).

    abstract::Digital tomosynthesis (DTS) is a fast, low-dose three-dimensional (3D) imaging approach which yields slice images with excellent in-plane resolution, though low plane-to-plane resolution. A stack of DTS slices can be reconstructed from a single limited-angle scan, with typical scan angles ranging from 10 degrees to 40...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2756941

    authors: Godfrey DJ,Ren L,Yan H,Wu Q,Yoo S,Oldham M,Yin FF

    更新日期:2007-08-01 00:00:00

  • Verification of absorbed dose determined with plane-parallel chambers in clinical electron beams following AAPM Task Group 39 protocol using ferrous sulphate dosimetry.

    abstract::The absorbed dose values determined with the Exradin and PTW-Markus plane-parallel chambers were compared to the values obtained with the ferrous sulphate dosimetry for a number of the Philips SL25 and the Therac 20 electron beams. For the plane-parallel chambers, the cavity-gas calibration factor Ngaspp, was derived ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597800

    authors: Xu Z,Li H,Almond PR,Guan TY

    更新日期:1996-03-01 00:00:00

  • Tracking the dynamic seroma cavity using fiducial markers in patients treated with accelerated partial breast irradiation using 3D conformal radiotherapy.

    abstract:PURPOSE:The purpose of the present study was to perform an analysis of the changes in the dynamic seroma cavity based on fiducial markers in early stage breast cancer patients treated with accelerated partial breast irradiation (APBI) using three-dimensional conformal external beam radiotherapy (3D-CRT). METHODS:A pro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4788644

    authors: Yue NJ,Haffty BG,Kearney T,Kirstein L,Chen S,Goyal S

    更新日期:2013-02-01 00:00:00

  • A method for determining multileaf collimator transmission and scatter for dynamic intensity modulated radiotherapy.

    abstract::The main purpose of this work is to demonstrate a practical means of determining the leaf transmission and scatter characteristics of a multileaf collimator (MLC) pertinent to the commissioning of dynamic intensity modulated radiotherapy, especially for the sweeping window technique. The data are necessary for the con...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1312190

    authors: Arnfield MR,Siebers JV,Kim JO,Wu Q,Keall PJ,Mohan R

    更新日期:2000-10-01 00:00:00

  • A new data augmentation method based on local image warping for medical image segmentation.

    abstract:PURPOSE:The segmentation accuracy of medical images was improved by increasing the number of training samples using a local image warping technique. The performance of the proposed method was evaluated in the segmentation of breast masses, prostate and brain tumors, and lung nodules. METHODS:We propose a simple data a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14651

    authors: Liu H,Cao H,Song E,Ma G,Xu X,Jin R,Liu T,Liu L,Liu D,Hung CC

    更新日期:2020-12-10 00:00:00

  • Image resolution of a microchannel plate x-ray image intensifier.

    abstract::The resolution has been evaluated for an experimental x-ray image intensifier employing three microchannel plates (MCPs) as the photon absorber and electron multipliers. The line spread function (LSF) was measured and used for determination of the modulation transfer function (MTF). The MTF was found to be independent...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594463

    authors: Gould RG

    更新日期:1978-01-01 00:00:00

  • Unequal weighting of given doses in opposed fields in treatment of cancer of the tonsillar region using 60Co, 4-, 8-, 15-, 24-MVp photons.

    abstract::Weighting of given doses from parallel opposed fields is a widespread practice in radiation therapy of cancer in the tonsillar region. In order to determine when weighting is useful, dose distributions on the central axis were calculated for various energies (60Co, 4-, 8-, 15-, and MVp photons), weighting factors, and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594276

    authors: Wollin M,Gilbert HA,Kagan AR

    更新日期:1976-03-01 00:00:00

  • Evaluating the impact of extended field-of-view CT reconstructions on CT values and dosimetric accuracy for radiation therapy.

    abstract:PURPOSE:Wide bore CT scanners use extended field-of-view (eFOV) reconstruction algorithms to attempt to recreate tissue truncated due to large patient habitus. Radiation therapy planning systems rely on accurate CT numbers in order to correctly plan and calculate radiation dose. This study looks at the impact of eFOV r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13299

    authors: Cheung JP,Shugard E,Mistry N,Pouliot J,Chen J

    更新日期:2019-02-01 00:00:00

  • Exposure artifacts in raster scanned equalization radiography.

    abstract::The image artifacts characteristic of a scanning chest radiographic system are reviewed. The technique employs a pulsed beam of radiation swept in an overlapping raster pattern that can result in severe ripple and scan line artifacts with improper scanning parameters. A one-dimensional treatment of the scanner geometr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595492

    authors: Plewes DB,Vogelstein E

    更新日期:1984-03-01 00:00:00

  • Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging.

    abstract:PURPOSE:The possible clinical applications which can be performed using a newly developed detector depend on the detector's characteristic performance in a number of metrics including the dynamic range, resolution, uniformity, and stability. The authors have evaluated a prototype energy resolved fast photon counting x-...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4892174

    authors: Cho HM,Barber WC,Ding H,Iwanczyk JS,Molloi S

    更新日期:2014-09-01 00:00:00

  • SU-E-T-429: Image-Guided Eye Plaque Brachytherapy Optimization: Implications for Patients at 2-Year Follow-up.

    abstract:PURPOSE:Episcleral eye plaque brachytherapy has been utilized in the treatment of intra-ocular malignancies, delivering large prescription doses to the apex of the tumor. Advances in dose calculation and image guidance, via calibrated fundus images, enable localization of the tumor and determination of dose to the macu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735518

    authors: Guida K,Niermann K,Malcolm A,Sternberg P,Munn G,Coffey C

    更新日期:2012-06-01 00:00:00

  • A comparative study of rectal dose histograms in prostate brachytherapy: some analytic and numerical results.

    abstract::A cumulative dose histogram is the graph of an integral function integrated over a domain VCR3 and is dubbed the dose-volume histogram (DVH), the dose-surface histogram (DSH) or the dose-wall histogram (DWH), depending on the dimension and structure of the region V. This paper presents a comparative study of the three...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1852811

    authors: Song JS,Albert M,D'Amico AV,Cormack RA

    更新日期:2005-02-01 00:00:00

  • The spatial resolution in dosimetry with normoxic polymer-gels investigated with the dose modulation transfer approach.

    abstract::The verification of dose distributions with high dose gradients as appearing in brachytherapy or stereotactic radiotherapy for example, calls for dosimetric methods with sufficiently high spatial resolution. Polymer gels in combination with a MR or optical scanner as a readout device have the potential of performing t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2898173

    authors: Bayreder C,Schön R,Wieland M,Georg D,Moser E,Berg A

    更新日期:2008-05-01 00:00:00

  • Characterization of the homogeneous tissue mixture approximation in breast imaging dosimetry.

    abstract:PURPOSE:To compare the estimate of normalized glandular dose in mammography and breast CT imaging obtained using the actual glandular tissue distribution in the breast to that obtained using the homogeneous tissue mixture approximation. METHODS:Twenty volumetric images of patient breasts were acquired with a dedicated...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4737025

    authors: Sechopoulos I,Bliznakova K,Qin X,Fei B,Feng SS

    更新日期:2012-08-01 00:00:00

  • Reduction of motion blurring artifacts using respiratory gated CT in sinogram space: a quantitative evaluation.

    abstract::Techniques have been developed for reducing motion blurring artifacts by using respiratory gated computed tomography (CT) in sinogram space and quantitatively evaluating the artifact reduction. A synthetic sinogram was built from multiple scans intercepting a respiratory gating window. A gated CT image was then recons...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2074187

    authors: Lu W,Parikh PJ,Hubenschmidt JP,Politte DG,Whiting BR,Bradley JD,Mutic S,Low DA

    更新日期:2005-11-01 00:00:00

  • Comparative dosimetry of diode and diamond detectors in electron beams for intraoperative radiation therapy.

    abstract::The aim of the present study is to examine the validity of using silicon semiconductor detectors in degraded electron beams with a broad energy spectrum and a wide angular distribution. A comparison is made with diamond detector measurements, which is the dosimeter considered to give the best results provided that dos...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1315317

    authors: Björk P,Knöös T,Nilsson P

    更新日期:2000-11-01 00:00:00

  • Postal intercomparison of absorbed dose for high energy x rays with thermoluminescence dosimeters.

    abstract::This study concerns the accuracy and precision of the IAEA/WHO LiF TLD system used in intercomparison by mail of absorbed doses from 60Co gamma-radiation and 4-25 MV x rays. The system employs 160 mg LiF powder in polystyrene capsules, which are placed at 5 or 7 cm depth in water and irradiated to doses close to 200 r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594746

    authors: Bjärngard BE,Kase KR,Rudén BI,Biggs PJ,Boyer AL,Johansson KA

    更新日期:1980-09-01 00:00:00