The spatial resolution in dosimetry with normoxic polymer-gels investigated with the dose modulation transfer approach.

Abstract:

:The verification of dose distributions with high dose gradients as appearing in brachytherapy or stereotactic radiotherapy for example, calls for dosimetric methods with sufficiently high spatial resolution. Polymer gels in combination with a MR or optical scanner as a readout device have the potential of performing the verification of a three-dimensional dose distribution within a single measurement. The purpose of this work is to investigate the spatial resolution achievable in MR-based polymer gel dosimetry. The authors show that dosimetry on a very small spatial scale (voxel size: 94 x 94 x 1000 microm3) can be performed with normoxic polymer gels using parameter selective T2 imaging. In order to prove the spatial resolution obtained we are relying on the dose-modulation transfer function (DMTF) concept based on very fine dose modulations at half periods of 200 microm. Very fine periodic dose modulations of a 60Co photon field were achieved by means of an absorption grid made of tungsten-carbide, specifically designed for quality control. The dose modulation in the polymer gel is compared with that of film dosimetry in one plane via the DMTF concept for general access to the spatial resolution of a dose imaging system. Additionally Monte Carlo simulations were performed and used for the calculation of the DMTF of both, the polymer gel and film dosimetry. The results obtained by film dosimetry agree well with those of Monte Carlo simulations, whereas polymer gel dosimetry overestimates the amplitude value of the fine dose modulations. The authors discuss possible reasons. The in-plane resolution achieved in this work competes with the spatial resolution of standard clinical film-scanner systems.

journal_name

Med Phys

journal_title

Medical physics

authors

Bayreder C,Schön R,Wieland M,Georg D,Moser E,Berg A

doi

10.1118/1.2898173

subject

Has Abstract

pub_date

2008-05-01 00:00:00

pages

1756-69

issue

5

eissn

0094-2405

issn

2473-4209

journal_volume

35

pub_type

杂志文章
  • Motion tracking of low-activity fiducial markers using adaptive region of interest with list-mode positron emission tomography.

    abstract:PURPOSE:Motion compensated positron emission tomography (PET) imaging requires detecting and monitoring of patient body motion. We developed a semiautomatic list-mode method to track the three-dimensional (3D) motion of fiducial positron-emitting markers during PET imaging. METHODS:A previously developed motion tracki...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14206

    authors: Chamberland MJP,deKemp RA,Xu T

    更新日期:2020-08-01 00:00:00

  • The feasibility study and characterization of a two-dimensional diode array in "magic phantom" for high dose rate brachytherapy quality assurance.

    abstract:PURPOSE:High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly (192)Ir with an air KERMA strength range between 20,000 and 40,000 U, where 1 U = 1 μGy m(2)/h in a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4822736

    authors: Espinoza A,Beeksma B,Petasecca M,Fuduli I,Porumb C,Cutajar D,Corde S,Jackson M,Lerch ML,Rosenfeld AB

    更新日期:2013-11-01 00:00:00

  • Patch-based generation of a pseudo CT from conventional MRI sequences for MRI-only radiotherapy of the brain.

    abstract:PURPOSE:In radiotherapy (RT) based on magnetic resonance imaging (MRI) as the only modality, the information on electron density must be derived from the MRI scan by creating a so-called pseudo computed tomography (pCT). This is a nontrivial task, since the voxel-intensities in an MRI scan are not uniquely related to e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4914158

    authors: Andreasen D,Van Leemput K,Hansen RH,Andersen JA,Edmund JM

    更新日期:2015-04-01 00:00:00

  • An artificial neural network for estimating scatter exposures in portable chest radiography.

    abstract::An adaptive linear element (Adaline) was developed to estimate the two-dimensional scatter exposure distribution in digital portable chest radiographs (DPCXR). DPCXRs and quantitative scatter exposure measurements at 64 locations throughout the chest were acquired for ten radiographically normal patients. The Adaline ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596978

    authors: Lo JY,Floyd CE Jr,Baker JA,Ravin CE

    更新日期:1993-07-01 00:00:00

  • Predicting radiotherapy-induced cardiac perfusion defects.

    abstract::The purpose of this work is to compare the efficacy of mathematical models in predicting the occurrence of radiotherapy-induced left ventricular perfusion defects assessed using single-photon emission computed tomography (SPECT). The basis of this study is data from 73 left-sided breast/ chestwall patients treated wit...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1823571

    authors: Das SK,Baydush AH,Zhou S,Miften M,Yu X,Craciunescu O,Oldham M,Light K,Wong T,Blazing M,Borges-Neto S,Dewhirst MW,Marks LB

    更新日期:2005-01-01 00:00:00

  • A data-mining framework for large scale analysis of dose-outcome relationships in a database of irradiated head and neck cancer patients.

    abstract:PURPOSE:To develop a hypothesis-generating framework for automatic extraction of dose-outcome relationships from an in-house, analytic oncology database. METHODS:Dose-volume histograms (DVH) and clinical outcomes have been routinely stored to the authors' database for 684 head and neck cancer patients treated from 200...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4922686

    authors: Robertson SP,Quon H,Kiess AP,Moore JA,Yang W,Cheng Z,Afonso S,Allen M,Richardson M,Choflet A,Sharabi A,McNutt TR

    更新日期:2015-07-01 00:00:00

  • A novel and individualized robust optimization method using normalized dose interval volume constraints (NDIVC) for intensity-modulated proton radiotherapy.

    abstract:PURPOSE:Intensity-modulated proton therapy (IMPT) is known to be sensitive to patient setup and range uncertainty issues. Multiple robust optimization methods have been developed to mitigate the impact of these uncertainties. Here, we propose a new robust optimization method, which provides an alternative way of robust...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13276

    authors: Shan J,Sio TT,Liu C,Schild SE,Bues M,Liu W

    更新日期:2019-01-01 00:00:00

  • The use of a diode matrix in commissioning activities for electron energies > or = 9 MeV: a feasibility study.

    abstract::The contribution of a commercially available diode matrix (MapCHECK, provided by Sun Nuclear, Melbourne, FL) for the commissioning procedures of the voxel based Monte Carlo (VMC++) algorithm for electron beams of MasterPlan treatment planning system was investigated. The attention is mainly focused on the calculation ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3081414

    authors: Borca VC,Pasquino M,Ozzello F,Tofani S

    更新日期:2009-04-01 00:00:00

  • Establishment of technical prerequisites for cell irradiation experiments with laser-accelerated electrons.

    abstract:PURPOSE:In recent years, laser-based acceleration of charged particles has rapidly progressed and medical applications, e.g., in radiotherapy, might become feasible in the coming decade. Requirements are monoenergetic particle beams with long-term stable and reproducible properties as well as sufficient particle intens...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3301598

    authors: Beyreuther E,Enghardt W,Kaluza M,Karsch L,Laschinsky L,Lessmann E,Nicolai M,Pawelke J,Richter C,Sauerbrey R,Schlenvoigt HP,Baumann M

    更新日期:2010-04-01 00:00:00

  • Establishment of a beam line at the Fermi National Accelerator Laboratory for proton radiography.

    abstract::A proton beam is extracted from the 200-MeV linear accelerator at the Fermi National Accelerator Laboratory to investigate the efficacy of proton radiography in medical diagnosis. Fluence rates from 2 X 10(3) to 2 X 10(5) protons/cm2s over a 28-cm diameter field are obtained with a full width at half-maximum beam-ener...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594426

    authors: Curry J,Steward VW

    更新日期:1978-05-01 00:00:00

  • High correlation between radiation dose estimates for 256-slice CT obtained by highly parallelized hybrid Monte Carlo computation and solid-state metal-oxide semiconductor field-effect transistor measurements in physical anthropomorphic phantoms.

    abstract:PURPOSE:Accurate, patient-specific radiation dosimetry for CT scanning is critical to optimize radiation doses and balance dose against image quality. While Monte Carlo (MC) simulation is often used to estimate doses from CT, comparison of estimates to experimentally measured values is lacking for advanced CT scanners ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13780

    authors: Prinsen P,Trattner S,Wiegert J,Gerland EL,Shefer E,Morton T,Thompson CM,Cheng B,Halliburton SS,Einstein AJ

    更新日期:2019-11-01 00:00:00

  • A dose-point-kernel model for a low energy gamma-emitting stent in a heterogeneous medium.

    abstract::A computer dose model for a low energy gamma-emitting stent in a heterogeneous medium is described. The method is based on the Sievert model which is adapted to the dose-point-kernel (DPK) model to compute the dose distribution about filtered gamma sources (Sievert-DPK model). The new gamma stent model can take into a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1380214

    authors: Janicki C,Duggan DM,Rahdert DA

    更新日期:2001-07-01 00:00:00

  • Inspection of visible components in urine based on deep learning.

    abstract:PURPOSE:Urinary particles are particularly important parameters in clinical urinalysis, especially for the diagnosis of nephropathy. Therefore, it is highly important to precisely detect urinary particles in the clinical setting. However, artificial microscopy is subjective and time consuming, and various previous dete...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14118

    authors: Li Q,Yu Z,Qi T,Zheng L,Qi S,He Z,Li S,Guan H

    更新日期:2020-07-01 00:00:00

  • Projection-based improvement of 3D reconstructions from motion-impaired dental cone beam CT data.

    abstract:PURPOSE:Computed tomography (CT) and, in particular, cone beam CT (CBCT) have been increasingly used as a diagnostic tool in recent years. Patient motion during acquisition is common in CBCT due to long scan times. This results in degraded image quality and may potentially increase the number of retakes. Our aim was to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13731

    authors: Niebler S,Schömer E,Tjaden H,Schwanecke U,Schulze R

    更新日期:2019-10-01 00:00:00

  • Ultrasonic tissue characterization via 2-D spectrum analysis: theory and in vitro measurements.

    abstract::A theoretical model is described for application in ultrasonic tissue characterization using a calibrated 2-D spectrum analysis method. This model relates 2-D spectra computed from ultrasonic backscatter signals to intrinsic physical properties of tissue microstructures, e.g., size, shape, and acoustic impedance. The ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2436978

    authors: Liu T,Lizzi FL,Ketterling JA,Silverman RH,Kutcher GJ

    更新日期:2007-03-01 00:00:00

  • Absorbed dose in the presence of contrast agents during pediatric cardiac catheterization.

    abstract::Administration of x-ray contrast agents during heart catheterization examination increases the absorbed radiation dose in tissue. To estimate the dose absorbed by the blood of children undergoing diagnostic heart catheterization and angiocardiography, a number of measurements and calculations were conducted. First, en...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594613

    authors: Callisen HH,Norman A,Adams FH

    更新日期:1979-11-01 00:00:00

  • SU-E-J-142: Gafchromic Film Dosimetry in Fluoroscopy for Dynamic Tumor Tracking Irradiation of the Lung Using XR-SP2 Model - A Phantom Study.

    abstract:PURPOSE:We have recently developed a dynamic tumor tracking irradiation system using Vero4DRT (MHI-Tm2 000). It is needed to create a 4D correlation model between a fiducial marker implanted near a tumor and an external surrogate as a function of time by continuously acquiring both fluoroscopy images and external surro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734978

    authors: Shiinoki T,Sawada A,Ishihara Y,Miyabe Y,Fujimoto T,Nakai T,Matsuo Y,Mizowaki T,Kokubo M,Hiraoka M

    更新日期:2012-06-01 00:00:00

  • Indirect flat-panel detector with avalanche gain: fundamental feasibility investigation for SHARP-AMFPI (scintillator HARP active matrix flat panel imager).

    abstract::An indirect flat-panel imager (FPI) with avalanche gain is being investigated for low-dose x-ray imaging. It is made by optically coupling a structured x-ray scintillator CsI(Tl) to an amorphous selenium (a-Se) avalanche photoconductor called HARP (high-gain avalanche rushing photoconductor). The final electronic imag...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2008428

    authors: Zhao W,Li D,Reznik A,Lui BJ,Hunt DC,Rowlands JA,Ohkawa Y,Tanioka K

    更新日期:2005-09-01 00:00:00

  • Beam shaper with optimized dose utility for helical cone-beam CT.

    abstract:PURPOSE:To develop a new design of an x-ray beam shaper for helical computed tomography (CT) that increases the dose utilization. METHODS:For typical reconstruction algorithms in helical CT, different data are utilized with different weights during back-projection. In particular, data of the outer detector rows, i.e.,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3577766

    authors: Köhler T,Brendel B,Proksa R

    更新日期:2011-07-01 00:00:00

  • Approaches to calculating AAPM TG-43 brachytherapy dosimetry parameters for 137Cs, 125I, 192Ir, 103Pd, and 169Yb sources.

    abstract::Underlying characteristics in brachytherapy dosimetry parameters for medical radionuclides 137Cs, 125I, 192Ir, 103Pd, and 169Yb were examined using Monte Carlo methods. Sources were modeled as unencapsulated point or line sources in liquid water to negate variations due to materials and construction. Importance of pha...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2199987

    authors: Melhus CS,Rivard MJ

    更新日期:2006-06-01 00:00:00

  • QA procedures for multimodality preclinical tumor drug response testing.

    abstract:PURPOSE:There are growing expectations that imaging biomarkers for tumor therapeutic drug response assessment will speed up preclinical testing of anticancer drugs in rodent models. The only imaging biomarker presently approved by the U.S. Food and Drug Administration is tumor size measurement based on either World Hea...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3464491

    authors: Lee YC,Goins BA,Fullerton GD

    更新日期:2010-09-01 00:00:00

  • Iodine kinetics and dosimetry in the salivary glands during repeated courses of radioiodine therapy for thyroid cancer.

    abstract:PURPOSE:The present study was conducted to investigate salivary iodine kinetics and dosimetry during repeated courses of radioiodine ((131)I) therapy for differentiated thyroid cancer (DTC). Such data could provide a better understanding of the mechanisms of (131)I induced salivary toxicity and help to develop appropri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3602459

    authors: Liu B,Huang R,Kuang A,Zhao Z,Zeng Y,Wang J,Tian R

    更新日期:2011-10-01 00:00:00

  • Effect of surrounding vasculature on intravoxel BOLD signal.

    abstract:PURPOSE:The nonlocal influence from distant magnetization will affect the magnetic field at a voxel in question. Existing reports on BOLD simulation only consider vasculature inside a single voxel, thus omitting the contribution from the surrounding regions. In this article, the authors study the effect of the surround...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3366251

    authors: Chen Z,Caprihan A,Calhoun V

    更新日期:2010-04-01 00:00:00

  • Radiation dose to the lungs from ventilation studies with 133Xe.

    abstract::The radiation dose to the lungs from 133Xe in lung air is directly proportional to the time integral of 133Xe concentration; i.e., the cumulated concentration in the lungs. Using kinetic models developed to fit clinical observations, we have studied the effect of retention on cumulated concentration in lung air. The m...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594341

    authors: Watson EE,Cloutier RJ

    更新日期:1977-11-01 00:00:00

  • Comparisons of treatment optimization directly incorporating systematic patient setup uncertainty with a margin-based approach.

    abstract:PURPOSE:To develop a probabilistic treatment planning (PTP) method which is robust to systematic patient setup errors and to compare PTP plans with plans generated using a planning target volume (PTV) margin optimized to give the same target coverage probability as the PTP plan. METHODS:Plans adhering to the RTOG-0126...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3679856

    authors: Moore JA,Gordon JJ,Anscher M,Silva J,Siebers JV

    更新日期:2012-02-01 00:00:00

  • An algorithm for fast beam angle selection in intensity modulated radiotherapy.

    abstract:PURPOSE:This article aims to introduce a novel algorithm for fast beam angle selection in intensity modulated radiotherapy (IMRT). METHODS:The algorithm models the optimization problem as a beam angle ranking problem and chooses suitable beam angles according to their rank. A new parameter called "beam intensity profi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3517866

    authors: Vaitheeswaran R,Narayanan VK,Bhangle JR,Nirhali A,Kumar N,Basu S,Maiya V

    更新日期:2010-12-01 00:00:00

  • Validation for 2D/3D registration. I: A new gold standard data set.

    abstract:PURPOSE:In this article, the authors propose a new gold standard data set for the validation of two-dimensional/three-dimensional (2D/3D) and 3D/3D image registration algorithms. METHODS:A gold standard data set was produced using a fresh cadaver pig head with attached fiducial markers. The authors used several imagin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3553402

    authors: Pawiro SA,Markelj P,Pernus F,Gendrin C,Figl M,Weber C,Kainberger F,Nöbauer-Huhmann I,Bergmeister H,Stock M,Georg D,Bergmann H,Birkfellner W

    更新日期:2011-03-01 00:00:00

  • A new data augmentation method based on local image warping for medical image segmentation.

    abstract:PURPOSE:The segmentation accuracy of medical images was improved by increasing the number of training samples using a local image warping technique. The performance of the proposed method was evaluated in the segmentation of breast masses, prostate and brain tumors, and lung nodules. METHODS:We propose a simple data a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14651

    authors: Liu H,Cao H,Song E,Ma G,Xu X,Jin R,Liu T,Liu L,Liu D,Hung CC

    更新日期:2020-12-10 00:00:00

  • Effects of point configuration on the accuracy in 3D reconstruction from biplane images.

    abstract::Two or more angiograms are being used frequently in medical imaging to reconstruct locations in three-dimensional (3D) space, e.g., for reconstruction of 3D vascular trees, implanted electrodes, or patient positioning. A number of techniques have been proposed for this task. In this simulation study, we investigate th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2008467

    authors: Dmochowski J,Hoffmann KR,Singh V,Xu J,Nazareth DP

    更新日期:2005-09-01 00:00:00

  • Characterization of a mammographic system based on single photon counting pixel arrays coupled to GaAs x-ray detectors.

    abstract::The authors report on the imaging capabilities of a mammographic system demonstrator based on GaAs pixel detectors operating in single photon counting (SPC) mode. The system imaging performances have been assessed by means of the transfer functions: The modulation transfer function (MTF), the normalized noise power sp...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3097284

    authors: Amendolia SR,Bisogni MG,Delogu P,Fantacci ME,Paternoster G,Rosso V,Stefanini A

    更新日期:2009-04-01 00:00:00