Motion tracking of low-activity fiducial markers using adaptive region of interest with list-mode positron emission tomography.

Abstract:

PURPOSE:Motion compensated positron emission tomography (PET) imaging requires detecting and monitoring of patient body motion. We developed a semiautomatic list-mode method to track the three-dimensional (3D) motion of fiducial positron-emitting markers during PET imaging. METHODS:A previously developed motion tracking method using positron-emitting markers (PeTrack) was enhanced to work with PET imaging. A novel combination of filtering methods was developed to reject physiological tracer background, which would drown out the events from the marker if unfiltered. The most critical filter rejects events whose line-of-response (LOR) is outside an adaptive region of interest (ADROI). The size of ROI was optimized by exploiting the distinct differences between the distributions of events from background and marker. The ADROI PeTrack method was evaluated with Monte Carlo and phantom studies. A 92.5-kBq 22 Na marker moving sinusoidally in 3D was simulated with Monte Carlo methods. The simulated events were combined with list-mode data from cardiac PET imaging patients to evaluate the performance of the tracking. In phantom studies, three 22 Na markers were placed on a dynamic torso phantom with an initial activity of 680 MBq of 82 Rb in its cardiac insert. The motion of the markers was tracked while the phantom simulated various types of patient motion. Motion correction on an event-by-event basis of the list-mode data was then applied and images were reconstructed. RESULTS:Simulation results show that the background rejection methods can significantly suppress the tracer background and increase the fraction of marker events by a factor of up to 2500. A 92.5-kBq marker can be tracked in 3D at a frequency of 2.0 Hz with an accuracy of 0.8 mm and a precision of 0.3 mm. The phantom study experimentally confirms that the algorithm can track various types of motion. The relative accuracy of the experimental tracking is 0.26 ± 0.14 mm. Motion-corrected images from the phantom study show reduced blurring. CONCLUSIONS:An algorithm and background rejection methods were developed that can track the 3D motion of low-activity positron-emitting markers during PET imaging. The motion information may be used for motion-compensated PET imaging.

journal_name

Med Phys

journal_title

Medical physics

authors

Chamberland MJP,deKemp RA,Xu T

doi

10.1002/mp.14206

subject

Has Abstract

pub_date

2020-08-01 00:00:00

pages

3402-3414

issue

8

eissn

0094-2405

issn

2473-4209

journal_volume

47

pub_type

杂志文章
  • Noise power spectra of images from digital mammography detectors.

    abstract::Noise characterization through estimation of the noise power spectrum (NPS) is a central component of the evaluation of digital x-ray systems. We begin with a brief review of the fundamentals of NPS theory and measurement, derive explicit expressions for calculation of the one- and two-dimensional (1D and 2D) NPS, and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598623

    authors: Williams MB,Mangiafico PA,Simoni PU

    更新日期:1999-07-01 00:00:00

  • Evaluation of the local dose enhancement in the combination of proton therapy and nanoparticles.

    abstract:PURPOSE:The outcome of radiotherapy can be further improved by combining irradiation with dose enhancers such as high-Z nanoparticles. Since 2004, spectacular results have been obtained when low-energy x-ray irradiations have been combined with nanoparticles. Recently, the same combination has been explored in hadron t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4934370

    authors: Martínez-Rovira I,Prezado Y

    更新日期:2015-11-01 00:00:00

  • Choice of material for HVL measurements in megavoltage x-ray beams.

    abstract::The relative sensitivity of the half-value layer (HVL) method as a quality index for megavoltage x-ray beams is examined by theoretical calculation and experimental measurements for 4-, 6-, 10-, and 25-MV x-ray beams. It is shown that lower atomic number materials are more sensitive to beam quality changes than higher...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595794

    authors: Meli JA,Nath R

    更新日期:1985-01-01 00:00:00

  • Sci-Thur PM: YIS - 08: The effect of copper conversion plates on low-Z target image quality.

    abstract::Current generation electronic portal imaging devices (EPID) contain a 1.0 mm copper conversion plate to increase detection efficiency of a therapeutic megavoltage spectrum. When using these EPIDs for low-Z target imaging, the conversion plate largely attenuates the large populations of diagnostic energy photons, there...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740105

    authors: Parsons D,Robar JL

    更新日期:2012-07-01 00:00:00

  • Gadolinium neutron capture therapy for brain tumors: a computer study.

    abstract::A Monte Carlo computer study of the total dose distribution from neutrons and prompt gamma emissions (but excluding the contribution from conversion and Auger electrons) for gadolinium neutron capture therapy of brain tumors has been carried out in order to test the theoretic feasibility of this modality using commerc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596761

    authors: Masiakowski JT,Horton JL,Peters LJ

    更新日期:1992-09-01 00:00:00

  • Calibration of a scintillation dosemeter for beta rays using an extrapolation ionization chamber.

    abstract::A scintillation dosemeter is calibrated for 90Sr/90Y beta rays from an ophthalmic applicator, using an extrapolation ionization chamber as a reference instrument. The calibration factor for the scintillation dosemeter agrees with that given by the manufacturer of the dosemeter within ca. 2%. The estimated overall unce...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1709490

    authors: Hakanen AT,Sipilä PM,Kosunen A

    更新日期:2004-05-01 00:00:00

  • Efficient implementations of a pseudodynamical stochastic filtering strategy for static elastography.

    abstract::A computationally efficient pseudodynamical filtering setup is established for elasticity imaging (i.e., reconstruction of shear modulus distribution) in soft-tissue organs given statically recorded and partially measured displacement data. Unlike a regularized quasi-Newton method (QNM) that needs inversion of ill-con...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3158808

    authors: Banerjee B,Roy D,Vasu RM

    更新日期:2009-08-01 00:00:00

  • Semiautomated four-dimensional computed tomography segmentation using deformable models.

    abstract::The purpose of this work is to demonstrate a proof of feasibility of the application of a commercial prototype deformable model algorithm to the problem of delineation of anatomic structures on four-dimensional (4D) computed tomography (CT) image data sets. We acquired a 4D CT image data set of a patient's thorax that...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1929207

    authors: Ragan D,Starkschall G,McNutt T,Kaus M,Guerrero T,Stevens CW

    更新日期:2005-07-01 00:00:00

  • Analyzing the impact of intrafraction motion: correlation of different dose metrics with changes in target D95%.

    abstract:PURPOSE:A number of techniques are available to determine the dosimetric impact of intrafraction motion during intensity modulated radiation therapy (IMRT). Motion-induced dose perturbations can be determined both computationally and experimentally using a number of different dosimetric metrics. However, these measures...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3605633

    authors: Waghorn BJ,Meeks SL,Langen KM

    更新日期:2011-08-01 00:00:00

  • A dosimetric comparison of 169Yb and 192Ir for HDR brachytherapy of the breast, accounting for the effect of finite patient dimensions and tissue inhomogeneities.

    abstract::Monte Carlo simulation dosimetry is used to compare 169Yb to 192Ir for breast high dose rate (HDR) brachytherapy applications using multiple catheter implants. Results for bare point sources show that while 169Yb delivers a greater dose rate per unit air kerma strength at the radial distance range of interest to brach...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2392408

    authors: Lymperopoulou G,Papagiannis P,Angelopoulos A,Karaiskos P,Georgiou E,Baltas D

    更新日期:2006-12-01 00:00:00

  • Elements of microdosimetry.

    abstract::This is an introductory tutorial to the field of microdosimetry. Following a brief historical outline, we review the physics of experimental and theoretical microdosimetry and the application of microdosimetry to radiation biology within the so-called "site" approximation. Modern interpretations of microdosimetry that...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.596616

    authors: Rossi HH,Zaider M

    更新日期:1991-11-01 00:00:00

  • Region-oriented CT image representation for reducing computing time of Monte Carlo simulations.

    abstract:PURPOSE:We propose a new method for efficient particle transportation in voxelized geometry for Monte Carlo simulations. We describe its use for calculating dose distribution in CT images for radiation therapy. MATERIAL AND METHODS:The proposed approach, based on an implicit volume representation named segmented volum...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2884854

    authors: Sarrut D,Guigues L

    更新日期:2008-04-01 00:00:00

  • Generation of arbitrary intensity profiles by combining the scanning beam with dynamic multileaf collimation.

    abstract::An algorithm, which combines the scanning beam with dynamic collimation to generate any arbitrary intensity profile, is presented. The desired intensity profile is assumed to be piecewise linear. The dynamic collimation method used is the "sliding window." The algorithm can be used either for a given scanning beam pro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597672

    authors: Spirou SV,Chui CS

    更新日期:1996-01-01 00:00:00

  • Evaluation of a direct motion estimation/correction method in respiratory-gated PET/MRI with motion-adjusted attenuation.

    abstract:PURPOSE:Respiratory motion compensation in PET/CT and PET/MRI is essential as motion is a source of image degradation (motion blur, attenuation artifacts). In previous work, we developed a direct method for joint image reconstruction/motion estimation (JRM) for attenuation-corrected (AC) respiratory-gated PET, which us...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12253

    authors: Bousse A,Manber R,Holman BF,Atkinson D,Arridge S,Ourselin S,Hutton BF,Thielemans K

    更新日期:2017-06-01 00:00:00

  • Measurement of energy dependence for XRCT radiochromic film.

    abstract::Gafchromic XRCT, radiochromic film is assessed over a broad energy range, from kilovoltage to megavoltage x rays for variations in reflected optical density to dose response. A large energy dependence was found with reflected optical density output for the same delivered dose varying from 7.8 +/- 0.35 at 25.5 keV (50 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2219330

    authors: Butson MJ,Cheung T,Yu PK

    更新日期:2006-08-01 00:00:00

  • A Monte Carlo estimation of effective dose in chest tomosynthesis.

    abstract:PURPOSE:The recent introduction of digital tomosynthesis imaging into routine clinical use has enabled the acquisition of volumetric patient data within a standard radiographic examination. Tomosynthesis requires the acquisition of multiple projection views, requiring additional dose compared to a standard projection e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3250907

    authors: Sabol JM

    更新日期:2009-12-01 00:00:00

  • WE-G-BRB-03: On the Detectability of Jaw Decalibrations with the DAVID System.

    abstract:PURPOSE:To evaluate if the recently described problems with the calibration of jaws at Varian linear accelerators can be detected with the DAVID system. METHODS:Recently Varian Clinac field size issues resulted in a widespread medical device correction notice, stating that incorrect jaw positioning due to excessive co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736189

    authors: Poppe B,Looe H,Harder D

    更新日期:2012-06-01 00:00:00

  • Scan pattern optimization for uniform proton beam scanning.

    abstract::Magnetic beam scanning allows one to spread proton beam over the desired radiation field area, improving beam utilization and conformity to the target area. This article discusses generic scan forms for generating uniform circular and rectangular fields and establishes criteria that can be applied to optimize selected...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3158731

    authors: Anferov VA

    更新日期:2009-08-01 00:00:00

  • Estimation of the axial wall strains induced by an arterial stenosis at peak flow.

    abstract::In the last 30 years, thousands of basic or clinical studies have been devoted to atherosclerosis or to the problem of restenosis after angioplasty. In these studies, axial stresses in the vessel wall have received practically no attention, contrary to circumferential stress and purely biological aspects. Based on a r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1844432

    authors: Doriot PA,Dorsaz PA

    更新日期:2005-02-01 00:00:00

  • Evaluation of the Gafchromic(®) EBT2 film for the dosimetry of radiosurgical beams.

    abstract:PURPOSE:Radiosurgery uses small fields and high-radiation doses to treat intra- and extracranial lesions in a single session. The lack of a lateral electronic equilibrium and the presence of high-dose gradients in these fields are challenges for adequate measurements. The availability of radiation detectors with the hi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4752211

    authors: Larraga-Gutierrez JM,Garcia-Hernandez D,Garcia-Garduno OA,Galvan de la Cruz OO,Ballesteros-Zebadua P,Esparza-Moreno KP

    更新日期:2012-10-01 00:00:00

  • Technical Note: Experimental determination of the effective point of measurement of two cylindrical ionization chambers in a clinical proton beam.

    abstract:PURPOSE:IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4921617

    authors: Sugama Y,Nishio T,Onishi H

    更新日期:2015-07-01 00:00:00

  • Nine-degrees-of-freedom flexmap for a cone-beam computed tomography imaging device with independently movable source and detector.

    abstract:PURPOSE:Couch-mounted cone-beam computed tomography (CBCT) imaging devices with independently rotatable x-ray source and flat-panel detector arms for acquisitions of arbitrary regions of interest (ROI) have recently been introduced in image-guided radiotherapy (IGRT). This work analyzes mechanical limitations and gravi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12033

    authors: Keuschnigg P,Kellner D,Fritscher K,Zechner A,Mayer U,Huber P,Sedlmayer F,Deutschmann H,Steininger P

    更新日期:2017-01-01 00:00:00

  • Comparisons of treatment optimization directly incorporating systematic patient setup uncertainty with a margin-based approach.

    abstract:PURPOSE:To develop a probabilistic treatment planning (PTP) method which is robust to systematic patient setup errors and to compare PTP plans with plans generated using a planning target volume (PTV) margin optimized to give the same target coverage probability as the PTP plan. METHODS:Plans adhering to the RTOG-0126...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3679856

    authors: Moore JA,Gordon JJ,Anscher M,Silva J,Siebers JV

    更新日期:2012-02-01 00:00:00

  • An optimization algorithm for intensity modulated radiotherapy--the simulated dynamics with dose-volume constraints.

    abstract::We have developed a new method for optimization in intensity modulated radiation therapy (IMRT) that makes use of simulated dynamics in a classical system of interacting particles. An analogy is drawn between intensity profile optimization in IMRT and relaxation to the equilibrium configuration in a dynamic system. Th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1528179

    authors: Hou Q,Wang J,Chen Y,Galvin JM

    更新日期:2003-01-01 00:00:00

  • Dose rate and SDD dependence of commercially available diode detectors.

    abstract::The dose-rate dependence of commercially available diode detectors was measured under both high instantaneous dose-rate (pulsed) and low dose rate (continuous, Co-60) radiation. The dose-rate dependence was measured in an acrylic miniphantom at a 5-cm depth in a 10 x 10 cm2 collimator setting, by varying source-to-det...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1650563

    authors: Saini AS,Zhu TC

    更新日期:2004-04-01 00:00:00

  • Automatic tumor segmentation in breast ultrasound images using a dilated fully convolutional network combined with an active contour model.

    abstract:PURPOSE:Due to the low contrast, blurry boundaries, and large amount of shadows in breast ultrasound (BUS) images, automatic tumor segmentation remains a challenging task. Deep learning provides a solution to this problem, since it can effectively extract representative features from lesions and the background in BUS i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13268

    authors: Hu Y,Guo Y,Wang Y,Yu J,Li J,Zhou S,Chang C

    更新日期:2019-01-01 00:00:00

  • Technical Note: A benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system with a high-power x-ray source and transmission CT imaging capability.

    abstract:PURPOSE:This report describes upgrades and performance characterization of an experimental benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system capable of determining the spatial distribution and concentration of metal probes such as gold nanoparticles (GNPs). Specifically, a high-power (~3 kW) indus...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13138

    authors: Manohar N,Reynoso FJ,Cho SH

    更新日期:2018-10-01 00:00:00

  • Iterative algebraic reconstruction algorithms for emission computed tomography: a unified framework and its application to positron emission tomography.

    abstract::In this paper, a unified framework of iterative algebraic reconstruction for emission computed tomography (ECT) and its application to positron emission tomography (PET) is presented. The unified framework is based on an algebraic image restoration model and contains conventional iterative algebraic reconstruction alg...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596954

    authors: Xu XL,Liow JS,Strother SC

    更新日期:1993-11-01 00:00:00

  • A Laplace transform pair model for spectral reconstruction.

    abstract::A four-parameter Laplace transform pair model, which accurately reconstructs an experimental bremsstrahlung spectrum from attenuation data, is presented. Computed spectral values with both aluminum and copper attenuators generally agree with experimental 70-kVp data to better than 2%. Reconstructed spectra at other kV...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595193

    authors: Archer BR,Wagner LK

    更新日期:1982-11-01 00:00:00

  • Evaluations of two solid water parallel-plate chambers in high-energy photon and electron beams.

    abstract::Using high-energy photon and electron beams, the response of two solid water parallel-plate chambers is evaluated against a PTW (Physicallsch-Technische Werkstatten) Farmer-type chamber. These two chambers are (1) a Memorial "Holt" chamber which was further modified by this author to take advantage of electrically con...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597074

    authors: Kubo H

    更新日期:1993-03-01 00:00:00