A novel and individualized robust optimization method using normalized dose interval volume constraints (NDIVC) for intensity-modulated proton radiotherapy.

Abstract:

PURPOSE:Intensity-modulated proton therapy (IMPT) is known to be sensitive to patient setup and range uncertainty issues. Multiple robust optimization methods have been developed to mitigate the impact of these uncertainties. Here, we propose a new robust optimization method, which provides an alternative way of robust optimization in IMPT, and is clinically practical, which will enable users to control the balance between nominal plan quality and plan robustness in a user-defined fashion. METHOD:We calculated nine individual dose distributions which corresponded to one nominal and eight extreme scenarios caused by patient setup and proton beam's range uncertainties. For each voxel, the normalized dose interval (NDI) is defined as the full dose range variation divided by the maximum dose in all uncertainty scenarios (NDI = [max - min dose]/max dose), which was then used to calculate the normalized dose interval volume histogram (NDIVH) curves. The areas under the NDIVH curves were used to quantify plan robustness. A normalized dose interval volume constraint (NDIVC) applied to the target was incorporated to specify the desired robustness which was user-defined. Users could then explore the trade-off between nominal plan quality and plan robustness by adjusting the position of the NDIVCs on the NDIVH curves freely. We benchmarked our method using one lung, five head and neck (H&N), and three prostate cases by comparing our results to those derived using the voxel-wise worst-case robust optimization. RESULTS:Using the benchmark cases, our new method achieved quality IMPT plans comparable to those derived from the voxel-wise worst-case robust optimization for both nominal plan quality and plan robustness in general; even more conformal and more homogeneous target dose distributions in some cases, if proper NDIVCs were applied. The AUC under NDIVH, as a precise quantitative index of plan robustness, was consistent with DVH bandwidths. Additionally, we demonstrated the feasibility of adjusting the position of NDIVCs in the NDIVH curves which allowed users to explore the trade-off between nominal plan quality and plan robustness. CONCLUSIONS:The NDIVH-based robust optimization method provided a novel and individualized way of robust optimization in IMPT, and enables users to adjust the balance between nominal plan quality and plan robustness in a user-defined fashion. This method is applicable for continued improvement and developing the next generation of IMPT planning algorithms in the future.

journal_name

Med Phys

journal_title

Medical physics

authors

Shan J,Sio TT,Liu C,Schild SE,Bues M,Liu W

doi

10.1002/mp.13276

subject

Has Abstract

pub_date

2019-01-01 00:00:00

pages

382-393

issue

1

eissn

0094-2405

issn

2473-4209

journal_volume

46

pub_type

杂志文章
  • Characterization of the nanoDot OSLD dosimeter in CT.

    abstract:PURPOSE:The extensive use of computed tomography (CT) in diagnostic procedures is accompanied by a growing need for more accurate and patient-specific dosimetry techniques. Optically stimulated luminescent dosimeters (OSLDs) offer a potential solution for patient-specific CT point-based surface dosimetry by measuring a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4914398

    authors: Scarboro SB,Cody D,Alvarez P,Followill D,Court L,Stingo FC,Zhang D,McNitt-Gray M,Kry SF

    更新日期:2015-04-01 00:00:00

  • Intercomparison of methods for image quality characterization. I. Modulation transfer function.

    abstract::The modulation transfer function (MTF) and the noise power spectrum (NPS) are widely recognized as the most relevant metrics of resolution and noise performance in radiographic imaging. These quantities have commonly been measured using various techniques, the specifics of which can have a bearing on the accuracy of t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2188816

    authors: Samei E,Ranger NT,Dobbins JT 3rd,Chen Y

    更新日期:2006-05-01 00:00:00

  • Displacement-based binning of time-dependent computed tomography image data sets.

    abstract::Respiration can cause tumors in the thorax or abdomen to move by as much as 3 cm; this movement can adversely affect the planning and delivery of radiation treatment. Several techniques have been used to compensate for respiratory motion, but all have shortcomings. Manufacturers of computed tomography (CT) equipment h...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2044427

    authors: Fitzpatrick MJ,Starkschall G,Antolak JA,Fu J,Shukla H,Keall PJ,Klahr P,Mohan R

    更新日期:2006-01-01 00:00:00

  • X-ray imaging with amorphous selenium: optimal spectra for digital mammography.

    abstract::The optimum x-ray spectra for acquisition of digital mammographic images using an amorphous selenium (a-Se) photoconductor are investigated. The recorded images consist of latent charge distributions on the surface of an a-Se plate, which are then read out using two methods, laser discharge, or flat panel recharge. Th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597688

    authors: Fahrig R,Rowlands JA,Yaffe MJ

    更新日期:1996-04-01 00:00:00

  • X-ray imaging technique for in vitro tissue composition measurements using saline/iodine displacement: technique optimization.

    abstract::An in vitro radiographic technique which uses saline/iodine displacement has been developed to study the thickness of bone-equivalent and soft-tissue-equivalent materials within atherosclerotic plaques in arterial specimens which have been cut open longitudinally and laid flat. Results concerning the optimization of t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597916

    authors: Moreau M,Holdsworth DW,Fenster A

    更新日期:1997-01-01 00:00:00

  • An optimization algorithm for 3D real-time lung tumor tracking during arc therapy using kV projection images.

    abstract:PURPOSE:To develop a real-time markerless 3D tumor tracking using kilovoltage (kV) cone-beam CT (CBCT) projection images during volumetric modulated arc therapy (VMAT) treatment of lung tumors. METHODS:The authors have developed a method to identify the position of lung tumors during VMAT treatment, where the current ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4821545

    authors: Zhuang L,Liang J,Yan D,Zhang T,Marina O,Ionascu D

    更新日期:2013-10-01 00:00:00

  • Dose and dose averaged LET comparison of ¹H, ⁴He, ⁶Li, ⁸Be, ¹⁰B, ¹²C, ¹⁴N, and ¹⁶O ion beams forming a spread-out Bragg peak.

    abstract:PURPOSE:Modern clinical accelerators are capable of producing ion beams from protons up to neon. This work compares the depth dose distribution and corresponding dose averaged linear energy transfer (LET) distribution, which is related to the biological effectiveness, for different ion beams (¹H, ⁴He, ⁶Li, ⁸Be, ¹⁰B, ¹²...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3662911

    authors: Kantemiris I,Karaiskos P,Papagiannis P,Angelopoulos A

    更新日期:2011-12-01 00:00:00

  • Model-based geometric calibration for medical x-ray systems.

    abstract:PURPOSE:Currently applied calibration approaches lead to satisfying 3D roadmapping overlay and 3D reconstruction accuracies; however, the required calibration times are extensive. The aim of this paper is the introduction of a novel model-based approach for geometric system calibrations, leading to a significant reduct...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4931964

    authors: van der Maas R,de Jager B,Steinbuch M,Dries J

    更新日期:2015-11-01 00:00:00

  • Determination of x-ray tube focal spot position.

    abstract::In x-ray spectral measurement using a semiconductor detector system, accurate positioning of the detector in front of the anode is very important. This needs accurate determination of the focal spot position on the target in an x-ray tube. We present a simple technique to determine the focal spot position accurately. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597122

    authors: Kubota H,Ozaki Y,Matsumoto M,Kanamori H

    更新日期:1993-07-01 00:00:00

  • Noise, sampling, and the number of projections in cone-beam CT with a flat-panel detector.

    abstract:PURPOSE:To investigate the effect of the number of projection views on image noise in cone-beam CT (CBCT) with a flat-panel detector. METHODS:This fairly fundamental consideration in CBCT system design and operation was addressed experimentally (using a phantom presenting a uniform medium as well as statistically moti...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4875688

    authors: Zhao Z,Gang GJ,Siewerdsen JH

    更新日期:2014-06-01 00:00:00

  • Ytterbium-169: calculated physical properties of a new radiation source for brachytherapy.

    abstract::Seeds containing radioactive Ytterbium-169 (169Yb) have recently been manufactured for possible application to brachytherapy. Ytterbium-169 emits photons with an average energy of 93 keV (excluding energies less than 10 keV), and decays with a half-life of 32 days. Analytic and Monte Carlo computations have been used ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596813

    authors: Mason DL,Battista JJ,Barnett RB,Porter AT

    更新日期:1992-05-01 00:00:00

  • A dosimetry study of the Oncoseed 6711 using glass rod dosimeters and EGS5 Monte Carlo code in a geometry lacking radiation equilibrium scatter conditions.

    abstract:PURPOSE:The aim of this study was to develop a dose calculation method which is applicable to the interseed attenuation and the geometry lacking the equilibrium radiation scatter conditions in brachytherapy. METHODS:The dose obtained from measurement with a radiophotoluminescent glass rod dosimeter (GRD) was compared ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3590370

    authors: Tanaka K,Tateoka K,Asanuma O,Kamo K,Bengua G,Sato K,Ueda T,Takeda H,Takagi M,Hareyama M,Takada J

    更新日期:2011-06-01 00:00:00

  • Comparison of ROC and AFC methods in a visual detection task.

    abstract::The visual observer performance for detecting low-contrast patterns by employing both the receiver operating characteristic (ROC) and the 9-alternative forced choice (9-AFC) method is investigated. For each observer and each experimental technique, the results were reproducible with respect to a repeated observation. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596986

    authors: Herrmann C,Buhr E,Hoeschen D,Fan SY

    更新日期:1993-05-01 00:00:00

  • A segmented 32P source Monte Carlo model to derive AAPM TG-60 dosimetric parameters used for intravascular brachytherapy.

    abstract::A new high dose rate 20 mm 32P intravascular brachytherapy (IVB) beta source used with automated stepping has recently been introduced. The AAPM Task Group 60 recommends that beta IVB sources should have well characterized dosimetric parameters in water. In this study, Monte Carlo simulations (MCNPX v 2.4) were used t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1646651

    authors: Mourtada F,Soares CG,Horton JL

    更新日期:2004-03-01 00:00:00

  • Tomotherapy dose distribution verification using MAGIC-f polymer gel dosimetry.

    abstract:PURPOSE:This paper presents the application of MAGIC-f gel in a three-dimensional dose distribution measurement and its ability to accurately measure the dose distribution from a tomotherapy unit. METHODS:A prostate intensity-modulated radiation therapy (IMRT) irradiation was simulated in the gel phantom and the treat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4704496

    authors: Pavoni JF,Pike TL,Snow J,DeWerd L,Baffa O

    更新日期:2012-05-01 00:00:00

  • Comparison of exposure standards in the mammography x-ray region.

    abstract::Direct comparisons of the National Institute of Standards and Technology's (NIST) Ritz 20 kV to 100 kV standard free-air ionization chamber and a portable variable-length free-air ionization chamber designed by the University of Wisconsin-Madison Accredited Dosimetry Calibration Laboratory (UW-ADCL) were made on NISTs...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598148

    authors: Coletti JG,Pearson DW,DeWerd LA,O'Brien CM,Lamperti PJ

    更新日期:1997-08-01 00:00:00

  • A 4 x 500 mm2 cloverleaf detector system for in vivo bone lead measurement.

    abstract::A 4 x 500 mm2 "cloverleaf" low energy germanium detector array has been assembled for the purpose of in vivo bone lead measurement through x-ray fluorescence. Using 109Cd as an exciting source, results are reported from a leg phantom simulating measurement of lead in a human tibia. For high activity (4.0-4.4 GBq) and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2436973

    authors: Fleming DE,Mills CE

    更新日期:2007-03-01 00:00:00

  • Invertibility of the dual energy x-ray data transform.

    abstract:PURPOSE:The Alvarez-Macovski method extracts the x-ray energy-dependent information by expanding the attenuation coefficient as a linear combination of functions of energy multiplied by basis set coefficients. Since the basis functions are known a priori, the coefficients represent all the energy-dependent information....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13255

    authors: Alvarez RE

    更新日期:2019-01-01 00:00:00

  • Calculation of surface dose in rotational total skin electron irradiation.

    abstract::A single-field rotational total skin electron irradiation technique has recently been developed at the McGill University for treatment of skin malignancies. The dose received by a given surface point during rotation in a uniform large electron field depends on the radius of rotation of the surface point, on the local ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595524

    authors: Pla C,Heese R,Pla M,Podgorsak EB

    更新日期:1984-07-01 00:00:00

  • Temporal and spectral imaging with micro-CT.

    abstract:PURPOSE:Micro-CT is widely used for small animal imaging in preclinical studies of cardiopulmonary disease, but further development is needed to improve spatial resolution, temporal resolution, and material contrast. We present a technique for visualizing the changing distribution of iodine in the cardiac cycle with du...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736809

    authors: Johnston SM,Johnson GA,Badea CT

    更新日期:2012-08-01 00:00:00

  • SU-E-T-429: Image-Guided Eye Plaque Brachytherapy Optimization: Implications for Patients at 2-Year Follow-up.

    abstract:PURPOSE:Episcleral eye plaque brachytherapy has been utilized in the treatment of intra-ocular malignancies, delivering large prescription doses to the apex of the tumor. Advances in dose calculation and image guidance, via calibrated fundus images, enable localization of the tumor and determination of dose to the macu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735518

    authors: Guida K,Niermann K,Malcolm A,Sternberg P,Munn G,Coffey C

    更新日期:2012-06-01 00:00:00

  • Phantoms with 10BF3 detectors for boron neutron capture therapy applications.

    abstract::Two acrylic cube phantoms have been constructed for BNCT applications that allow the depth distribution of neutrons to be measured with miniature 10BF3 detectors in 0.5-cm steps beginning at 1-cm depth. Sizes and weights of the cubes are 14 cm, 3.230 kg, and 11 cm, 1.567 kg. Tests were made with the epithermal neutron...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598354

    authors: Alburger DE,Raparia D,Zucker MS

    更新日期:1998-09-01 00:00:00

  • Temporal stability assessment in shear wave elasticity images validated by deep learning neural network for chronic liver disease fibrosis stage assessment.

    abstract:PURPOSE:To automatically detect and isolate areas of low and high stiffness temporal stability in shear wave elastography (SWE) image sequences and define their impact in chronic liver disease (CLD) diagnosis improvement by means of clinical examination study and deep learning algorithm employing convolutional neural n...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13521

    authors: Gatos I,Tsantis S,Spiliopoulos S,Karnabatidis D,Theotokas I,Zoumpoulis P,Loupas T,Hazle JD,Kagadis GC

    更新日期:2019-05-01 00:00:00

  • SU-E-T-555: Weighted Four-Dimensional IMRT Planning for Dynamic MLC Tracking Using a Practical and Simple Framework.

    abstract:PURPOSE:We present a simple, practical framework for truly 4D lung IMRT planning based on a weighted individual-phase optimization paradigm. This strategy is specifically developed for use in real-time tumor tracking delivery systems so as to utilize respiratory motion as an additional degree of freedom rather than a c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735644

    authors: Tachibana H,Cheung Y,Jain S,Sawant A

    更新日期:2012-06-01 00:00:00

  • Use of CEA TVS film for measuring high energy photon beam dose distributions.

    abstract::CEA TVS film is a therapy verification film that has been recently introduced in the North American market. This film features linear characteristic curves for photon energies from 137Cs to 18 MV as reported by Cheng and Das [Med. Phys. 23, 1225 (1996)]. In Saskatoon, TVS film was investigated for its application in t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598316

    authors: Cadman P

    更新日期:1998-08-01 00:00:00

  • Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT.

    abstract::The physical factors that govern 2D and 3D imaging performance may be understood from quantitative analysis of the spatial-frequency-dependent signal and noise transfer characteristics [e.g., modulation transfer function (MTF), noise-power spectrum (NPS), detective quantum efficiency (DQE), and noise-equivalent quanta...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3002414

    authors: Tward DJ,Siewerdsen JH

    更新日期:2008-12-01 00:00:00

  • Toward adaptive radiotherapy for head and neck patients: Uncertainties in dose warping due to the choice of deformable registration algorithm.

    abstract:PURPOSE:The aims of this work were to evaluate the performance of several deformable image registration (DIR) algorithms implemented in our in-house software (NiftyReg) and the uncertainties inherent to using different algorithms for dose warping. METHODS:The authors describe a DIR based adaptive radiotherapy workflow...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4905050

    authors: Veiga C,Lourenço AM,Mouinuddin S,van Herk M,Modat M,Ourselin S,Royle G,McClelland JR

    更新日期:2015-02-01 00:00:00

  • An evaluation of the TSE MR sequence for time efficient data acquisition in polymer gel dosimetry of applications involving high doses and steep dose gradients.

    abstract::The use of magnetic resonance imaging as a readout method for polymer gel dosimetry commonly involves long imaging sessions, particularly when high spatial resolution is required in all three dimensions, for the investigation of dose distributions with steep dose gradients and stringent dose delivery specifications. I...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2065367

    authors: Baras P,Seimenis I,Sandilos P,Vlahos L,Bieganski T,Georgiou E,Pantelis E,Papagiannis P,Sakelliou L

    更新日期:2005-11-01 00:00:00

  • Gamma dose measurement in a d(80) + Be neutron beam.

    abstract::The gamma-ray dose component of a d(80) + Be neutron beam was measured with a 6Li-shielded Geiger-Mueller counter in a tissue-equivalent liquid phantom. The proportion of gamma-ray dose to total dose increased from 0.07 near the surface to 0.09 at 25 cm depth. Due to thermal neutron sensitivity, the G-M count rate inc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594571

    authors: Harrison GH,Cox CR

    更新日期:1979-05-01 00:00:00

  • High resolution stationary digital breast tomosynthesis using distributed carbon nanotube x-ray source array.

    abstract:PURPOSE:The purpose of this study is to investigate the feasibility of increasing the system spatial resolution and scanning speed of Hologic Selenia Dimensions digital breast tomosynthesis (DBT) scanner by replacing the rotating mammography x-ray tube with a specially designed carbon nanotube (CNT) x-ray source array,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3694667

    authors: Qian X,Tucker A,Gidcumb E,Shan J,Yang G,Calderon-Colon X,Sultana S,Lu J,Zhou O,Spronk D,Sprenger F,Zhang Y,Kennedy D,Farbizio T,Jing Z

    更新日期:2012-04-01 00:00:00