X-ray imaging with amorphous selenium: optimal spectra for digital mammography.

Abstract:

:The optimum x-ray spectra for acquisition of digital mammographic images using an amorphous selenium (a-Se) photoconductor are investigated. The recorded images consist of latent charge distributions on the surface of an a-Se plate, which are then read out using two methods, laser discharge, or flat panel recharge. The investigation is based on a model of the breast previously developed for a phosphor-based digital readout system, and has been extended to include the effects specific to the use of photoconductors. The effects of plate thickness, x-ray scatter, readout noise, dose, and the kind of breast tissue on the nature of the optimum spectrum are explored for the two readout methods. The results indicate that use of a kilovoltage setting in the current mammographic range, and a molybdenum target spectrum is appropriate for digital readout of a-Se detectors. This conclusion contrasts with the appreciably higher kilovoltages traditionally used with the xerographic (toner) readout of latent charge images on a-Se.

journal_name

Med Phys

journal_title

Medical physics

authors

Fahrig R,Rowlands JA,Yaffe MJ

doi

10.1118/1.597688

subject

Has Abstract

pub_date

1996-04-01 00:00:00

pages

557-67

issue

4

eissn

0094-2405

issn

2473-4209

journal_volume

23

pub_type

杂志文章
  • Reference standard and statistical model for intersite and temporal comparisons of CT attenuation in a multicenter quantitative lung study.

    abstract:PURPOSE:The purpose of this study was to detect and analyze anomalies between a large number of computed tomography (CT) scanners, tracked over time, utilized to collect human pulmonary CT data for a national multicenter study: chronic obstructive pulmonary disease genetic epidemiology study (COPDGene). METHODS:A cust...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4747342

    authors: Sieren JP,Newell JD,Judy PF,Lynch DA,Chan KS,Guo J,Hoffman EA

    更新日期:2012-09-01 00:00:00

  • Radiofrequency transmit calibration: A multi-center evaluation of vendor-provided radiofrequency transmit mapping methods.

    abstract:PURPOSE:To determine the accuracy and test-retest repeatability of fast radiofrequency (RF) transmit measurement approaches used in Dynamic Contrast Enhanced Magnetic Resonance Imaging (DCE-MRI). Spatial variation in the transmitted RF field introduces bias and increased variance in quantitative DCE-MRI metrics includi...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1002/mp.13518

    authors: Bliesener Y,Zhong X,Guo Y,Boss M,Bosca R,Laue H,Chung C,Sung K,Nayak KS

    更新日期:2019-06-01 00:00:00

  • SU-E-J-11: Characterization of Interfractioanal Anatomical Variations in Post-Operative Radiation Therapy for Prostate Bed.

    abstract:PURPOSE:To quantitatively characterize the interfractional anatomic variations in post-operative radiation therapy (RT) for prostate bed, so that appropriate strategy that can fully address these variations can be developed. METHODS:A total of 102 daily pre-treatment CT acquired using an in-room CT (CTVision, Siemens)...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734844

    authors: Liu F,Ahunbay E,Christian R,Lawton C,Wang D,Li X

    更新日期:2012-06-01 00:00:00

  • The effects of motion on quantitative vessel measurements.

    abstract::Optimal visualization of moving structures such as the heart and coronary arteries using digital radiographic imaging systems is a difficult problem that can involve tradeoffs between temporal, spatial, and density resolution. The motion dependence of four angiographic measures of vessel dimensions is given and demons...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595651

    authors: Parker DL,Clayton PD,Gustafson DE

    更新日期:1985-11-01 00:00:00

  • Automated registration of diagnostic to prediagnostic x-ray mammograms: evaluation and comparison to radiologists' accuracy.

    abstract:PURPOSE:To compare and evaluate intensity-based registration methods for computation of serial x-ray mammogram correspondence. METHODS:X-ray mammograms were simulated from MRIs of 20 women using finite element methods for modeling breast compressions and employing a MRI/x-ray appearance change model. The parameter con...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3457470

    authors: Pinto Pereira SM,Hipwell JH,McCormack VA,Tanner C,Moss SM,Wilkinson LS,Khoo LA,Pagliari C,Skippage PL,Kliger CJ,Hawkes DJ,Silva IM

    更新日期:2010-09-01 00:00:00

  • Monitoring radiation use in cardiac fluoroscopy imaging procedures.

    abstract:PURPOSE:Timely identification of systematic changes in radiation delivery of an imaging system can lead to a reduction in risk for the patients involved. However, existing quality assurance programs involving the routine testing of equipment performance using phantoms are limited in their ability to effectively carry o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3524224

    authors: Stevens NT,Steiner SH,Smith IR,MacKay RJ

    更新日期:2011-01-01 00:00:00

  • Vision 20/20: Molecular-guided surgical oncology based upon tumor metabolism or immunologic phenotype: Technological pathways for point of care imaging and intervention.

    abstract::Surgical guidance with fluorescence has been demonstrated in individual clinical trials for decades, but the scientific and commercial conditions exist today for a dramatic increase in clinical value. In the past decade, increased use of indocyanine green based visualization of vascular flow, biliary function, and tis...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4951732

    authors: Pogue BW,Paulsen KD,Samkoe KS,Elliott JT,Hasan T,Strong TV,Draney DR,Feldwisch J

    更新日期:2016-06-01 00:00:00

  • Efficient implementations of a pseudodynamical stochastic filtering strategy for static elastography.

    abstract::A computationally efficient pseudodynamical filtering setup is established for elasticity imaging (i.e., reconstruction of shear modulus distribution) in soft-tissue organs given statically recorded and partially measured displacement data. Unlike a regularized quasi-Newton method (QNM) that needs inversion of ill-con...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3158808

    authors: Banerjee B,Roy D,Vasu RM

    更新日期:2009-08-01 00:00:00

  • Computer-assisted beam modeling for particle therapy.

    abstract:PURPOSE:To develop a computer-driven and thus less user-dependent method, allowing for a simple and straightforward generation of a Monte Carlo (MC) beam model of a scanned proton and carbon ion beam delivery system. METHODS:In a first step, experimental measurements were performed for proton and carbon ion energies i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14647

    authors: Fuchs H,Elia A,Resch AF,Kuess P,Lühr A,Vidal M,Grevillot L,Georg D

    更新日期:2020-12-07 00:00:00

  • Dosimetric comparison of helical tomotherapy treatment plans for total marrow irradiation created using GPU and CPU dose calculation engines.

    abstract:PURPOSE:To compare optimization characteristics, plan quality, and treatment delivery efficiency between total marrow irradiation (TMI) plans using the new TomoTherapy graphic processing unit (GPU) based dose engine and CPU/cluster based dose engine. METHODS:Five TMI plans created on an anthropomorphic phantom were op...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4810936

    authors: Nalichowski A,Burmeister J

    更新日期:2013-07-01 00:00:00

  • A respiratory-gated treatment system for proton therapy.

    abstract::Proton therapy offers the potential for excellent dose conformity and reduction in integral dose. The superior dose distribution is, however, much more sensitive to changes in radiological depths along the beam path than for photon fields. Respiratory motion can cause such changes for treatments sites like lung, liver...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2756602

    authors: Lu HM,Brett R,Sharp G,Safai S,Jiang S,Flanz J,Kooy H

    更新日期:2007-08-01 00:00:00

  • Characteristics of an OSLD in the diagnostic energy range.

    abstract:PURPOSE:Optically stimulated luminescence (OSL) dosimetry has been recently introduced in radiation therapy as a potential alternative to the thermoluminescent dosimeter (TLD) system. The aim of this study was to investigate the feasibility of using OSL point dosimeters in the energy range used in diagnostic imaging. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3602456

    authors: Al-Senan RM,Hatab MR

    更新日期:2011-07-01 00:00:00

  • Patient specific optimization of the relation between CT-hounsfield units and proton stopping power with proton radiography.

    abstract::The purpose of this work is to show the feasibility of using in vivo proton radiography of a radiotherapy patient for the patient individual optimization of the calibration from CT-Hounsfield units to relative proton stopping power. Water equivalent tissue (WET) calibrated proton radiographs of a dog patient treated f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1833041

    authors: Schneider U,Pemler P,Besserer J,Pedroni E,Lomax A,Kaser-Hotz B

    更新日期:2005-01-01 00:00:00

  • On the constancy in composition of polystyrene and polymethylmethacrylate plastics.

    abstract::Variations in the atomic composition, and mass and electron densities of polystyrene and polymethylmethacrylate (PMM) plastics were assessed from experimentally determined mass attenuation coefficients for 125I and 137Cs gamma rays. The means and standard deviations in the mass densities of 16 samples of PMM and 10 sa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594528

    authors: Schulz RJ,Nath R

    更新日期:1979-03-01 00:00:00

  • Resolution of pinhole collimators used with gamma cameras.

    abstract::The line spread function (LSF) of an imaging system incorporating a pinhole of 0.275 cm radius and a scintillation camera has been measured and its full width at half maximum (FWHM) compared to the values predicted by an expression based on the resolution index of Anger. In most cases, the actual resolution of the sys...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594755

    authors: Goulet P,Joy ML

    更新日期:1980-09-01 00:00:00

  • Changes realized from extended bit-depth and metal artifact reduction in CT.

    abstract:PURPOSE:High-Z material in computed tomography (CT) yields metal artifacts that degrade image quality and may cause substantial errors in dose calculation. This study couples a metal artifact reduction (MAR) algorithm with enhanced 16-bit depth (vs standard 12-bit) to quantify potential gains in image quality and dosim...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4805102

    authors: Glide-Hurst C,Chen D,Zhong H,Chetty IJ

    更新日期:2013-06-01 00:00:00

  • Reference dataset of users' photon beam modeling parameters for the Eclipse, Pinnacle, and RayStation treatment planning systems.

    abstract:PURPOSE:The aim of this work was to provide a novel description of how the radiotherapy community configures treatment planning system (TPS) radiation beam models for clinically used treatment machines. Here we describe the results of a survey of self-reported TPS beam modeling parameter values across different C-arm l...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13892

    authors: Glenn MC,Peterson CB,Followill DS,Howell RM,Pollard-Larkin JM,Kry SF

    更新日期:2020-01-01 00:00:00

  • Influence of phantom diameter, kVp and scan mode upon computed tomography dose index.

    abstract::The computed tomography (CT) radiation dose to pediatric patients has received considerable attention recently. Moreover, it is important to be able to determine CT radiation doses for various patient sizes ranging from infants to large adults. The current AAPM protocol only measures CT radiation dose using a 16 cm ac...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1543149

    authors: Nickoloff EL,Dutta AK,Lu ZF

    更新日期:2003-03-01 00:00:00

  • Convolutional neural network-based dosimetry evaluation of esophageal radiation treatment planning.

    abstract:PURPOSE:A dosimetry evaluation model for treatment planning of esophageal radiation therapy is developed using a deep learning model. The model predicts dose volume histogram (DVH) from distance to target histogram (DTH) based on stacked de-noise auto-encoder (SDAE) and one-dimensional convolutional network (1D-CN). M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14434

    authors: Jiang D,Yan H,Chang N,Li T,Mao R,Du C,Guo B,Liu J

    更新日期:2020-10-01 00:00:00

  • Small-field electron dosimetry for the Philips SL25 linear accelerator.

    abstract::Electron-beam characteristics of a Philips SL25 linear accelerator have been studied. Central-axis percentage depth doses, cross-beam profiles and beam output factors of 6-, 10-, and 20-MeV beams, selected from the available energy range of 4 to 22 MeV, are reported in this paper. The main thrust of this work is to de...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596471

    authors: Rashid H,Islam MK,Gaballa H,Rosenow UF,Ting JY

    更新日期:1990-07-01 00:00:00

  • SU-E-T-142: Evaluation of the Energy Dependence of Gafchromic EBT3 Film for Electron Beams.

    abstract:PURPOSE:To evaluate the energy dependence of Gafchromic EBT3 film for establishing a quality assurance method of bolus electron conformal radiotherapy. METHODS:We irradiated electron beam to EBT3 films, which were set in the water tank. The linear accelerator used was Varian Clinac 21EX. The energy of electron beams w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735200

    authors: Inoue T,Sugimoto S,Fukata K,Kurokawa C,Ozawa S,Sasai K

    更新日期:2012-06-01 00:00:00

  • Impact of calibration methods for color medical displays on interpreting brain SPECT images.

    abstract:PURPOSE:Color images are visualized on medical monitors that are adjusted by a grayscale standard display function (GSDF) or γ2.2. Although the GSDF is visually displayed as a linear graded grayscale, it does not specify how color medical images should be presented. On the other hand, the usual gamma setting for color ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13532

    authors: Shibutani T,Onoguchi M,Yoneyama H,Nakajima K,Matsuo S,Bamba Y,Saito S

    更新日期:2019-06-01 00:00:00

  • Dosimetric problems at low monitor unit settings for scanned and scattering foil electron beams.

    abstract::Electron beam dosimetry at low monitor unit (MU) settings is important for dosimetric applications. Dose linearity, beam flatness, and beam energies were studied at low MU settings with various dose rates for different types of linear accelerators. It is observed that for the scattering foil units, the dose/MU is a sm...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597328

    authors: Das IJ,Harrington JC,Akber SF,Tomer AF,Murray JC,Cheng CW

    更新日期:1994-06-01 00:00:00

  • Radionuclide photon dose kernels for internal emitter dosimetry.

    abstract::Photon point dose kernels and absorbed fractions were generated in water for the full photon emission spectrum of each radionuclide of interest in nuclear medicine, by simulating the transport of particles using Monte Carlo. The kernels were then fitted to a mathematical expression. Absorbed fractions for point source...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597670

    authors: Furhang EE,Sgouros G,Chui CS

    更新日期:1996-05-01 00:00:00

  • Investigation of effective decision criteria for multiobjective optimization in IMRT.

    abstract:PURPOSE:To investigate how using different sets of decision criteria impacts the quality of intensity modulated radiation therapy (IMRT) plans obtained by multiobjective optimization. METHODS:A multiobjective optimization evolutionary algorithm (MOEA) was used to produce sets of IMRT plans. The MOEA consisted of two i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3589128

    authors: Holdsworth C,Stewart RD,Kim M,Liao J,Phillips MH

    更新日期:2011-06-01 00:00:00

  • Phantoms with 10BF3 detectors for boron neutron capture therapy applications.

    abstract::Two acrylic cube phantoms have been constructed for BNCT applications that allow the depth distribution of neutrons to be measured with miniature 10BF3 detectors in 0.5-cm steps beginning at 1-cm depth. Sizes and weights of the cubes are 14 cm, 3.230 kg, and 11 cm, 1.567 kg. Tests were made with the epithermal neutron...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598354

    authors: Alburger DE,Raparia D,Zucker MS

    更新日期:1998-09-01 00:00:00

  • Development and validation of a measurement-based source model for kilovoltage cone-beam CT Monte Carlo dosimetry simulations.

    abstract:PURPOSE:The purpose of this study is to adapt an equivalent source model originally developed for conventional CT Monte Carlo dose quantification to the radiation oncology context and validate its application for evaluating concomitant dose incurred by a kilovoltage (kV) cone-beam CT (CBCT) system integrated into a lin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4823795

    authors: McMillan K,McNitt-Gray M,Ruan D

    更新日期:2013-11-01 00:00:00

  • A pencil beam algorithm for magnetic resonance image-guided proton therapy.

    abstract:PURPOSE:The feasibility of magnetic resonance image (MRI)-based proton therapy is based, among several other factors, on the implementation of appropriate extensions on current dose calculation methods. This work aims to develop a pencil beam algorithm (PBA) for dose calculation of proton beams within magnetic field re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12854

    authors: Padilla-Cabal F,Georg D,Fuchs H

    更新日期:2018-05-01 00:00:00

  • SU-E-T-162: Rapid Assessment of Cyberknife IRIS Variable Collimator Performance Using a Commercial Diode Array.

    abstract:PURPOSE:To describe an efficient method for verifying the size and centering of the radiation field from the Cyberknife IRIS variable collimator with sub-millimeter accuracy using a general purpose commercially available diode array. METHODS:We present a technique using a conventional diode array (Sun Nuclear Profiler...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735220

    authors: Gibbs G,White G,Bulz G

    更新日期:2012-06-01 00:00:00

  • Mapping structural changes in breast tissue disease using x-ray scattering.

    abstract::Spread of invasive carcinoma throughout breast tissue is believed to occur at supramolecular levels, beyond the range of standard histopathology identification. Small angle x-ray scattering (SAXS) is capable of characterizing the structural properties of collagen and tissue found in the breast at the scale of tens to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3147144

    authors: Sidhu S,Siu KK,Falzon G,Hart SA,Foxe JG,Lewis RA

    更新日期:2009-07-01 00:00:00