SU-E-J-142: Gafchromic Film Dosimetry in Fluoroscopy for Dynamic Tumor Tracking Irradiation of the Lung Using XR-SP2 Model - A Phantom Study.

Abstract:

PURPOSE:We have recently developed a dynamic tumor tracking irradiation system using Vero4DRT (MHI-Tm2 000). It is needed to create a 4D correlation model between a fiducial marker implanted near a tumor and an external surrogate as a function of time by continuously acquiring both fluoroscopy images and external surrogate signals. The purpose of this study was to propose a new dosimetry method using Gafchromic XR-SP2 films to measure surface dose by fluoroscopy imaging. METHODS:First, half-value layers (HVLs) were measured using aluminum (Al) thicknesses (15 mm) at 40125 kVp. Subsequently, several films were irradiated using various milliampere second values on a solid water phantom. The surface air kerma were also measured using the chamber to calculate the surface doses under the same condition. Then, the calibration curve of dose vs. pixel values was calculated. Finally, surface dose by fluoroscopy imaging was measured using several pieces of film taped on the chest phantom. Orthogonal X-ray fluoroscopy imaging was simultaneously performed until completion of data acquisition for creating a 4D correlation model. Those films were scanned after irradiation using a flat-bed scanner and converted to dose by calibration curve. RESULTS:The HVLs for tube voltage within 40125 kVp ranged from 2.35 to 5.98 mm Al. The calibration curve between surface dose and pixel values was reasonably smooth. The differences between the measured and the calibrated doses were less than 3%. The hot spots with the maximum dose of 37.12 mGy were observed around the area overlapped by both fluoroscopic fields. CONCLUSIONS:We have proposed a new dosimetry method using Gafchromic XR-SP2 films to measure surface dose by fluoroscopy imaging. This phantom study has demonstrated that it may be feasible to assess surface dose to patients during dynamic tumor tracking irradiation in clinic with ease after further investigation. This research was supported by the Japan Society for the Promotion of Science (JSPS) through its Funding Program for World-Leading Innovation R&D on Science and Technology (FIRST Program). Research sponsored in part by Mitsubishi Heavy Industries, Ltd.

journal_name

Med Phys

journal_title

Medical physics

authors

Shiinoki T,Sawada A,Ishihara Y,Miyabe Y,Fujimoto T,Nakai T,Matsuo Y,Mizowaki T,Kokubo M,Hiraoka M

doi

10.1118/1.4734978

subject

Has Abstract

pub_date

2012-06-01 00:00:00

pages

3685

issue

6Part8

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • Shimming with permanent magnets for the x-ray detector in a hybrid x-ray/ MR system.

    abstract::In this x-ray/MR hybrid system an x-ray flat panel detector is placed under the patient cradle, close to the MR volume of interest (VOI), where the magnetic field strength is approximately 0.5 T. Immersed in this strong field, several electronic components inside the detector become magnetized and create an additional...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2963994

    authors: Wen Z,Fahrig R,Williams ST,Pelc NJ

    更新日期:2008-09-01 00:00:00

  • Fast contour propagation for MR-guided prostate radiotherapy using convolutional neural networks.

    abstract:PURPOSE:To quickly and automatically propagate organ contours from pretreatment to fraction images in magnetic resonance (MR)-guided prostate external-beam radiotherapy. METHODS:Five prostate cancer patients underwent 20 fractions of image-guided external-beam radiotherapy on a 1.5 T MR-Linac system. For each patient,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13994

    authors: Eppenhof KAJ,Maspero M,Savenije MHF,de Boer JCJ,van der Voort van Zyp JRN,Raaymakers BW,Raaijmakers AJE,Veta M,van den Berg CAT,Pluim JPW

    更新日期:2020-03-01 00:00:00

  • Dosimetric characterization of radionuclides for systemic tumor therapy: influence of particle range, photon emission, and subcellular distribution.

    abstract::Various radionuclides have been proposed for systemic tumor therapy. However, in most dosimetric analysis of proposed radionuclides the charged particles are taken into consideration while the potential photons are ignored. The photons will cause undesirable irradiation of normal tissue, and increase the probability o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2229428

    authors: Uusijärvi H,Bernhardt P,Ericsson T,Forssell-Aronsson E

    更新日期:2006-09-01 00:00:00

  • TU-G-BRB-01: Continuous Path Optimization for Non-Coplanar Variant SAD IMRT Delivery Using C-Arm Machines.

    abstract:PURPOSE:To develop and investigate a continuous path optimization methodology to traverse prescribed non-coplanar IMRT beams with variant SADs, by orchestrating the couch and gantry movement with zero-collision, minimal patient motion consequence and machine travel time. METHODS:We convert the given collision zone def...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735996

    authors: Ruan D,Dong P,Low D,Sheng K

    更新日期:2012-06-01 00:00:00

  • Quantification of breast density with dual energy mammography: a simulation study.

    abstract::Breast density, the percentage of glandular breast tissue, has been identified as an important yet underutilized risk factor in the development of breast cancer. A quantitative method to measure breast density with dual energy imaging was investigated using a computer simulation model. Two configurations to measure br...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3002308

    authors: Ducote JL,Molloi S

    更新日期:2008-12-01 00:00:00

  • SU-C-218-06: Evaluation of a CT-Based, Semi-Automated Lung Mass Estimation Method Under Varying Acquisition Conditions.

    abstract:PURPOSE:To evaluate a simple, semi-automated lung mass estimation method on CT scans from a variety of acquisition techniques for mass correction of MIRD dose estimates. METHODS:CT scans from ten patients undergoing stereotactic body radiation therapy treatment planning on a GE DST PET/CT scanner were analyzed retrosp...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734654

    authors: Busse N,Erwin W,Pan T

    更新日期:2012-06-01 00:00:00

  • Spectrally resolved bioluminescence tomography using the reciprocity approach.

    abstract::Spectrally resolved bioluminescence optical tomography is an approach to recover images of, for example, Luciferase activity within a volume using multiwavelength emission data from internal bioluminescence sources. The underlying problem of uniqueness associated with nonspectrally resolved intensity-based bioluminesc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2982138

    authors: Dehghani H,Davis SC,Pogue BW

    更新日期:2008-11-01 00:00:00

  • Quantitative classification of breast tumors in digitized mammograms.

    abstract::The goal of this study was to develop a technique to distinguish benign and malignant breast lesions in secondarily digitized mammograms. A set of 51 mammograms (two views/patient) containing lesions of known pathology were evaluated using six different morphological descriptors: circularity, mu R/sigma R (where mu R ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597707

    authors: Pohlman S,Powell KA,Obuchowski NA,Chilcote WA,Grundfest-Broniatowski S

    更新日期:1996-08-01 00:00:00

  • Validation of deformable registration in head and neck cancer using analysis of variance.

    abstract:PURPOSE:Deformable image registration (DIR) is often validated based on a distance-to-agreement (DTA) criterion of automatically propagated anatomical landmarks that were manually identified. Due to human observer variability, however, the performance of the registration method is diluted. The purpose of this study was...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4760990

    authors: Mencarelli A,van Beek S,van Kranen S,Rasch C,van Herk M,Sonke JJ

    更新日期:2012-11-01 00:00:00

  • Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy.

    abstract::The objective of this work is to assess the suitability and performance of a new dosimeter system with a novel geometry for the quality assurance (QA) of volumetric modulated arc therapy (VMAT). The new dosimeter system consists of a hollow cylinder (15 and 25 cm inner and outer diameters) with 124 diodes embedded in ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3117563

    authors: Létourneau D,Publicover J,Kozelka J,Moseley DJ,Jaffray DA

    更新日期:2009-05-01 00:00:00

  • Practical reconstruction protocol for quantitative (90)Y bremsstrahlung SPECT/CT.

    abstract:PURPOSE:To develop a practical background compensation (BC) technique to improve quantitative (90)Y-bremsstrahlung single-photon emission computed tomography (SPECT)/computed tomography (CT) using a commercially available imaging system. METHODS:All images were acquired using medium-energy collimation in six energy wi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4960629

    authors: Siman W,Mikell JK,Kappadath SC

    更新日期:2016-09-01 00:00:00

  • Acceptance testing and quality assurance of automated scanning film densitometers used in the dosimetry of electron and photon therapy beams.

    abstract::Scanning film densitometry routinely used for obtaining dosimetric information about therapy treatment beams is subject to several sources of inaccuracies. The most significant of these are described and appropriate methods of testing are presented. This establishes the need for adequate acceptance testing followed by...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595407

    authors: Holmes TW,McCullough EC

    更新日期:1983-09-01 00:00:00

  • SU-E-T-582: Assessment of Improved Critical Structure Sparing Using Biologically- Based Optimization for Volumetric Modulated Arc Therapy of Head and Neck Cancer.

    abstract:PURPOSE:To investigate the critical structure sparing achievable by biological optimization for modulated volumetric arc (VMAT) of head and neck (H&N) cancer. METHODS:Ten H&N VMAT patients who were originally planned and treated with simultaneous integrated boost technique using dose-volume based optimization, were se...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735671

    authors: Dogan N,Wu Y

    更新日期:2012-06-01 00:00:00

  • Evaluation of dual energy quantitative CT for determining the spatial distributions of red marrow and bone for dosimetry in internal emitter radiation therapy.

    abstract:PURPOSE:To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy. METHODS:The DEQCT method was applied to 80/140 kVp images of patient-simulating lumb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4870378

    authors: Goodsitt MM,Shenoy A,Shen J,Howard D,Schipper MJ,Wilderman S,Christodoulou E,Chun SY,Dewaraja YK

    更新日期:2014-05-01 00:00:00

  • Effect of T1-mapping technique and diminished image resolution on quantification of infarct mass and its ability in predicting appropriate ICD therapy.

    abstract:PURPOSE:Myocardial infarct (MI) may consist of an infarct core (IC) and a heterogeneous, semi-viable border zone (BZ). Patients with chronic MI in the left ventricular (LV) myocardium are at increased risk of developing ventricular arrhythmias, and may therefore qualify for implantable cardioverter defibrillator (ICD) ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12840

    authors: Farrag NA,Ramanan V,Wright GA,Ukwatta E

    更新日期:2018-04-01 00:00:00

  • Principles in positioning cross-projecting lasers.

    abstract::With the increased sophistication of lasers used for patient positioning in radiotherapy comes increased possibilities for mistakes in installing the lasers, which can result in serious patient positioning errors. Two principles must be followed when mounting cross-projecting lasers: (1) the horizontal line must be on...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594960

    authors: Thomadsen BR

    更新日期:1981-05-01 00:00:00

  • Technical Note: Introduction of variance component analysis to setup error analysis in radiotherapy.

    abstract:PURPOSE:The purpose of this technical note is to introduce variance component analysis to the estimation of systematic and random components in setup error of radiotherapy. METHODS:Balanced data according to the one-factor random effect model were assumed. RESULTS:Analysis-of-variance (anova)-based computation was ap...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4961397

    authors: Matsuo Y,Nakamura M,Mizowaki T,Hiraoka M

    更新日期:2016-09-01 00:00:00

  • SU-E-T-558: Assessing the Effect of Inter-Fractional Motion in Esophageal Sparing Plans.

    abstract:PURPOSE:To compare esophageal dose distributions in esophageal sparing IMRT plans with predicted dose distributions which include the effect of inter-fraction motion. METHODS:Seven lung cancer patients were used, each with a standard and an esophageal sparing plan (74Gy, 2Gy fractions). The average max dose to esophag...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735647

    authors: Williamson R,Bluett J,Niedzielski J,Liao Z,Gomez D,Court L

    更新日期:2012-06-01 00:00:00

  • VMAT and IMRT plan-specific correction factors for linac-based ionization chamber dosimetry.

    abstract:PURPOSE:The determination of absorbed dose to water from external beam radiotherapy using radiation detectors is currently rooted in calibration protocols that do not account for modulations encountered in patient-specific deliveries. Detector response in composite clinical fields has not been extensively studied due t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13293

    authors: Desai VK,Labby ZE,Hyun MA,DeWerd LA,Culberson WS

    更新日期:2019-02-01 00:00:00

  • SU-E-T-283: Carbon Ion Therapy Innovations in Dosimetry and Dose Delivery.

    abstract:OBJECTIVE:Carbon ion particle therapy delivers sharp Bragg's peaks, and hence can produce dose delivery of very high precision and conformality. To complement this characteristic, particle therapy centers implement a number of technologies unique to these centers, and are not commonly known to the medical physics commu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735351

    authors: Cernica G,Mun S

    更新日期:2012-06-01 00:00:00

  • Tracking the dynamic seroma cavity using fiducial markers in patients treated with accelerated partial breast irradiation using 3D conformal radiotherapy.

    abstract:PURPOSE:The purpose of the present study was to perform an analysis of the changes in the dynamic seroma cavity based on fiducial markers in early stage breast cancer patients treated with accelerated partial breast irradiation (APBI) using three-dimensional conformal external beam radiotherapy (3D-CRT). METHODS:A pro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4788644

    authors: Yue NJ,Haffty BG,Kearney T,Kirstein L,Chen S,Goyal S

    更新日期:2013-02-01 00:00:00

  • Fluid-filled dynamic bowtie filter: Description and comparison with other modulators.

    abstract:PURPOSE:A dynamic bowtie filter can modulate flux along both fan and view angles for reduced patient dose, scatter, and required photon flux, which is especially important for photon counting detectors (PCDs). Among the proposed dynamic bowtie designs, the piecewise-linear attenuator (Hsieh and Pelc, Med Phys. 2013;40:...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13272

    authors: Shunhavanich P,Hsieh SS,Pelc NJ

    更新日期:2019-01-01 00:00:00

  • Calibration of a scintillation dosemeter for beta rays using an extrapolation ionization chamber.

    abstract::A scintillation dosemeter is calibrated for 90Sr/90Y beta rays from an ophthalmic applicator, using an extrapolation ionization chamber as a reference instrument. The calibration factor for the scintillation dosemeter agrees with that given by the manufacturer of the dosemeter within ca. 2%. The estimated overall unce...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1709490

    authors: Hakanen AT,Sipilä PM,Kosunen A

    更新日期:2004-05-01 00:00:00

  • Ethics and professionalism in medical physics: a survey of AAPM members.

    abstract:PURPOSE:To assess current education, practices, attitudes, and perceptions pertaining to ethics and professionalism in medical physics. METHODS:A link to a web-based survey was distributed to the American Association of Physicists in Medicine (AAPM) e-mail membership list, with a follow-up e-mail sent two weeks later....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4797463

    authors: Ozturk N,Armato SG 3rd,Giger ML,Serago CF,Ross LF

    更新日期:2013-04-01 00:00:00

  • SU-E-T-398: Verification of Gamma Knife EXtend System Based Fractionated Treatment Planning Using EBT2 Film.

    abstract:PURPOSE:To present EBT2 film verification of treatment planning with the eXtend System, a relocatable frame system for multiple-fraction or serial multiple-session radiosurgery. METHODS:A human head shaped phantom simulated the verification process for fractionated Gamma Knife (GK) treatment. Phantom preparation for e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735487

    authors: Gopishankar N,Bisht RK

    更新日期:2012-06-01 00:00:00

  • Analysis of generalized rosette trajectory for compressed sensing MRI.

    abstract:PURPOSE:The application of compressed sensing (CS) technology in magnetic resonance imaging (MRI) is to accelerate the MRI scan speed by incoherent undersampling of k-space data and nonlinear iterative reconstruction of MRI images. This paper generalizes the existing rosette trajectories to configure the sampling patte...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4928152

    authors: Li Y,Yang R,Zhang C,Zhang J,Jia S,Zhou Z

    更新日期:2015-09-01 00:00:00

  • Design and optimization of large area thin-film CdTe detector for radiation therapy imaging applications.

    abstract:PURPOSE:The authors investigate performance of thin-film cadmium telluride (CdTe) in detecting high-energy (6 MV) x rays. The utilization of this material has become technologically feasible only in recent years due to significant development in large area photovoltaic applications. METHODS:The CdTe film is combined w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3438082

    authors: Parsai EI,Shvydka D,Kang J

    更新日期:2010-08-01 00:00:00

  • A novel total variation based ring artifact suppression method for CBCT imaging with two-dimensional antiscatter grids.

    abstract:PURPOSE:Two-dimensional antiscatter grids (2DASG) for cone beam computed tomography (CBCT) is a new area of research to reduce scatter intensity, and consequently improve CBCT image quality. One of the challenges in implementation of 2DASGs is their septa shadows that are impinged on the projections. If these artifacts...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13456

    authors: Alexeev T,Kavanagh B,Miften M,Altunbas C

    更新日期:2019-05-01 00:00:00

  • Maximum likelihood analysis of free-response receiver operating characteristic (FROC) data.

    abstract::Receiver operating characteristic (ROC) methodology is widely used in evaluating medical imaging modalities. While appropriate in some cases, it has several drawbacks when the detection task, e.g., nodule detection, involves localizing the abnormality. Free-response receiver operating characteristic (FROC) methodology...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596358

    authors: Chakraborty DP

    更新日期:1989-07-01 00:00:00

  • Measurement of backscatter to the monitor chamber of medical accelerators using target charge.

    abstract::A simple noninvasive method is described for determining the backscatter to a monitor chamber of a medical accelerator based on the measurement of charge deposited in the target. This method is compared quantitatively to the more elaborate telescopic method for photon beams of 6 MV and 15 MV on linear accelerators hav...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598203

    authors: Lam KL,Muthuswamy MS,Ten Haken RK

    更新日期:1998-03-01 00:00:00