Maximum likelihood analysis of free-response receiver operating characteristic (FROC) data.

Abstract:

:Receiver operating characteristic (ROC) methodology is widely used in evaluating medical imaging modalities. While appropriate in some cases, it has several drawbacks when the detection task, e.g., nodule detection, involves localizing the abnormality. Free-response receiver operating characteristic (FROC) methodology offers a more natural framework to describe observer performance in such studies and has other advantages. Due to the lack of a statistical analysis procedure comparable to the maximum likelihood procedure (ROCFIT program) available for ROC studies, the FROC method has not gained widespread acceptance. This work presents and solves a two parameter model for the statistical analysis of FROC data. The model assumes that the probability density of the signal stimuli is normally distributed, as is the probability density for producing one or more false positives per image. A program (FROCFIT) is described for estimating the parameters and their uncertainties from experimental data. An index of performance is proposed to quantify observer performance in FROC experiments. Application of this methodology to several FROC data sets produced good to excellent fits.

journal_name

Med Phys

journal_title

Medical physics

authors

Chakraborty DP

doi

10.1118/1.596358

subject

Has Abstract

pub_date

1989-07-01 00:00:00

pages

561-8

issue

4

eissn

0094-2405

issn

2473-4209

journal_volume

16

pub_type

杂志文章
  • A general algorithm for calculation of recombination losses in ionization chambers exposed to ion beams.

    abstract:PURPOSE:Dosimetry with ionization chambers in clinical ion beams for radiation therapy requires correction for recombination effects. However, common radiation protocols discriminate between initial and general recombination and provide no universal correction method for the presence of both recombination types in ion ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4962483

    authors: Christensen JB,Tölli H,Bassler N

    更新日期:2016-10-01 00:00:00

  • A Dirichlet process mixture model for automatic (18)F-FDG PET image segmentation: Validation study on phantoms and on lung and esophageal lesions.

    abstract:PURPOSE:The aim of this study was to implement a Dirichlet process mixture (DPM) model for automatic tumor edge identification on (18)F-fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) images by optimizing the parameters on which the algorithm depends, to validate it experimentally, and to test its robus...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4947123

    authors: Giri MG,Cavedon C,Mazzarotto R,Ferdeghini M

    更新日期:2016-05-01 00:00:00

  • Gold nanoparticle enhanced proton therapy: A Monte Carlo simulation of the effects of proton energy, nanoparticle size, coating material, and coating thickness on dose and radiolysis yield.

    abstract:PURPOSE:Radiosensitizer enhanced radiotherapy provides the possibility of improved treatment outcomes by preferentially increasing the effectiveness of radiation within the tumor. Proton therapy offers improved sparing of tissue distal of the tumor along the beam path and reduced integral dose compared to conventional ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13923

    authors: Peukert D,Kempson I,Douglass M,Bezak E

    更新日期:2020-02-01 00:00:00

  • Poster - Thurs Eve-38: CT Imaging in high dose rate brachytherapy for treatment of cervical cancer: Estimation of dose to bowel.

    abstract::Treatment of cervical cancer often involves intracavitary high dose rate (HDR) brachytherapy. Dose delivered to the bladder and rectum are typically estimated using the ICRU reference points. Dose to the sigmoid and small bowel are not estimated, yet these organs typically exhibit significant complication rates. The o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965957

    authors: Lekx-Toniolo KS,Hunter R,Patel M,Voruganti S,Johanson C,Dhamanaskar K,Farrell T

    更新日期:2008-07-01 00:00:00

  • Modification and benchmarking of MCNP for low-energy tungsten spectra.

    abstract::The MCNP Monte Carlo radiation transport code was modified for diagnostic medical physics applications. In particular, the modified code was thoroughly benchmarked for the production of polychromatic tungsten x-ray spectra in the 30-150 kV range. Validating the modified code for coupled electron-photon transport with ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1288397

    authors: Mercier JR,Kopp DT,McDavid WD,Dove SB,Lancaster JL,Tucker DM

    更新日期:2000-12-01 00:00:00

  • Design and evaluation of an MRI-compatible linear motion stage.

    abstract:PURPOSE:To develop and evaluate a tool for accurate, reproducible, and programmable motion control of imaging phantoms for use in motion sensitive magnetic resonance imaging (MRI) appli cations. METHODS:In this paper, the authors introduce a compact linear motion stage that is made of nonmagnetic material and is actua...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4937780

    authors: Tavallaei MA,Johnson PM,Liu J,Drangova M

    更新日期:2016-01-01 00:00:00

  • Dependence with air density of the response of the PTW SourceCheck ionization chamber for low energy brachytherapy sources.

    abstract:PURPOSE:Air-communicating well ionization chambers are commonly used to assess air kerma strength of sources used in brachytherapy. The signal produced is supposed to be proportional to the air density within the chamber and, therefore, a density-independent air kerma strength is obtained when the measurement is correc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4831757

    authors: Tornero-López AM,Guirado D,Perez-Calatayud J,Ruiz-Arrebola S,Simancas F,Gazdic-Santic M,Lallena AM

    更新日期:2013-12-01 00:00:00

  • QA procedures for multimodality preclinical tumor drug response testing.

    abstract:PURPOSE:There are growing expectations that imaging biomarkers for tumor therapeutic drug response assessment will speed up preclinical testing of anticancer drugs in rodent models. The only imaging biomarker presently approved by the U.S. Food and Drug Administration is tumor size measurement based on either World Hea...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3464491

    authors: Lee YC,Goins BA,Fullerton GD

    更新日期:2010-09-01 00:00:00

  • Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques.

    abstract:PURPOSE:To characterize a new air vented ionization chamber technology, suitable to build detector arrays with small pixel pitch and independence of sensitivity on dose per pulse. METHODS:The prototype under test is a linear array of air vented ionization chambers, consisting of 80 pixels with 3.5 mm pixel pitch dista...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4945414

    authors: Togno M,Wilkens JJ,Menichelli D,Oechsner M,Perez-Andujar A,Morin O

    更新日期:2016-05-01 00:00:00

  • Sample size requirements for estimating effective dose from computed tomography using solid-state metal-oxide-semiconductor field-effect transistor dosimetry.

    abstract:PURPOSE:Effective dose (ED) is a widely used metric for comparing ionizing radiation burden between different imaging modalities, scanners, and scan protocols. In computed tomography (CT), ED can be estimated by performing scans on an anthropomorphic phantom in which metal-oxide-semiconductor field-effect transistor (M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4868693

    authors: Trattner S,Cheng B,Pieniazek RL,Hoffmann U,Douglas PS,Einstein AJ

    更新日期:2014-04-01 00:00:00

  • Anthropomorphic 1H MRS head phantom.

    abstract::An anthropomorphic 1H MRS head phantom has been developed which mimics the in vivo structure, metabolite concentrations, and relaxation times (for both water and metabolites) of human brain tissue. Different brain regions and two tumor types, fluid-containing ventricles, and air-filled sinus, and subcutaneous fat are ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598306

    authors: Rice JR,Milbrandt RH,Madsen EL,Frank GR,Boote EJ,Blechinger JC

    更新日期:1998-07-01 00:00:00

  • Fast internal marker tracking algorithm for onboard MV and kV imaging systems.

    abstract::Intrafraction organ motion can limit the advantage of highly conformal dose techniques such as intensity modulated radiation therapy (IMRT) due to target position uncertainty. To ensure high accuracy in beam targeting, real-time knowledge of the target location is highly desired throughout the beam delivery process. T...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2905225

    authors: Mao W,Wiersma RD,Xing L

    更新日期:2008-05-01 00:00:00

  • Four-dimensional intensity-modulated radiation therapy planning for dynamic tracking using a direct aperture deformation (DAD) method.

    abstract:PURPOSE:Planning for the delivery of intensity-modulated radiation therapy (IMRT) to a moving target, referred to as four-dimensional (4D) IMRT planning, is a crucial step for achieving the treatment objectives for sites that move during treatment delivery. The authors proposed a simplistic method that accounts for bot...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3319498

    authors: Gui M,Feng Y,Yi B,Dhople AA,Yu C

    更新日期:2010-05-01 00:00:00

  • A K alpha dual energy x-ray source for coronary angiography.

    abstract::The use of characteristic-line radiation from rare-earth targets bombarded by high-energy (up to 1 MeV) electron beams has been evaluated as an x-ray source for dual energy K-edge subtraction imaging of the human coronary arteries. Two characteristic-line x-ray sources, one using the split K alpha 1 and K alpha 2 line...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596648

    authors: Manning HL,Shefer RE,Klinkowstein RE,Mistretta CA

    更新日期:1991-09-01 00:00:00

  • Absorbed dose distributions from ophthalmic 106 Ru/106 Rh plaques measured in water with radiochromic film.

    abstract:PURPOSE:Brachytherapy with 106 Ru/106 Rh plaques offers good outcomes for small-to-medium choroidal melanomas and retinoblastomas. The dose measurement of the plaques is challenging, due to the small range of the emitted beta particles and steep dose gradients involved. The scarce publications on film dosimetry of 106 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12777

    authors: Hermida-López M,Brualla L

    更新日期:2018-04-01 00:00:00

  • SU-E-J-58: Patient-Specific Biomechanical Head and Neck Models for Interfraction Dose Accumulation.

    abstract:PURPOSE:In this abstract, we discuss a biomechanical head and neck model that will be able to represent patient setup variations as well as physiologic changes and subsequently enable dose calculations on the deformed anatomy. METHODS:We selected Multi Pose MRI as the imaging modality to aid in model development and v...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734893

    authors: Santhanam A,Ennis D,Low D,Kupelian P

    更新日期:2012-06-01 00:00:00

  • Three-dimensional canine heart model for cardiac elastography.

    abstract:PURPOSE:A three-dimensional finite element analysis based canine heart model is introduced that would enable the assessment of cardiac function. METHODS:The three-dimensional canine heart model is based on the cardiac deformation and motion model obtained from the Cardiac Mechanics Research Group at UCSD. The canine h...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3496326

    authors: Chen H,Varghese T

    更新日期:2010-11-01 00:00:00

  • A limit on dose reduction possible with CT reconstruction algorithms without prior knowledge of the scan subject.

    abstract:PURPOSE:To find an upper bound on the maximum dose reduction possible for any reconstruction algorithm, analytic or iterative, that result from the inclusion of the data statistics. The authors do not analyze noise reduction possible from prior knowledge or assumptions about the object. METHODS:The authors examined th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4941954

    authors: Hsieh SS,Chesler DA,Fleischmann D,Pelc NJ

    更新日期:2016-03-01 00:00:00

  • A double mirror W/C multilayer monochromator for radiation biology applications.

    abstract::A double-mirror multilayer monochromator was developed for the purpose of irradiating live cell cultures at the Synchrotron Radiation Center, University of Wisconsin-Madison. The monochromator is designed for the soft x-ray region with photon energies between 270 and 2400 eV. Multilayer mirrors with 55 bilayers of W/C...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598259

    authors: MacKay JF,Pearson DW,Nelms BE,DeLuca PM Jr,Gould MN,Lagally MG

    更新日期:1998-05-01 00:00:00

  • SU-E-I-16: Automated Liver Segmentation Method for CBCT Dataset by Probabilistic Atlas Construction.

    abstract:PURPOSE:The aiming is getting accurate liver contour structures automatically for following adaptive radiation therapy in daily CBCT images which is very low-contrast comparing the planning CT. METHODS:Probabilistic atlas is constructed by 50 intravenous contrast planning CT images by iterative affine registration pro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734730

    authors: Li D,Li H,Yin Y,Chen J

    更新日期:2012-06-01 00:00:00

  • Accounting for the fringe magnetic field from the bending magnet in a Monte Carlo accelerator treatment head simulation.

    abstract:PURPOSE:Monte Carlo (MC) simulation can be used for accurate electron beam treatment planning and modeling. Measurement of large electron fields, with the applicator removed and secondary collimator wide open, has been shown to provide accurate simulation parameters, including asymmetry in the measured dose, for the fu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3592640

    authors: O'Shea TP,Foley MJ,Faddegon BA

    更新日期:2011-06-01 00:00:00

  • Vision 20/20: Positron emission tomography in radiation therapy planning, delivery, and monitoring.

    abstract::Positron emission tomography (PET) is increasingly considered as an effective imaging method to support several stages of radiation therapy. The combined usage of functional and morphological imaging in state-of-the-art PET/CT scanners is rapidly emerging to support the treatment planning process in terms of improved ...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.4935869

    authors: Parodi K

    更新日期:2015-12-01 00:00:00

  • Respiratory phase alignment improves blood-flow quantification in Rb82 PET myocardial perfusion imaging.

    abstract:PURPOSE:Positron emission tomography (PET) is considered the gold standard for measuring myocardial blood flow in vivo but it is known that respiratory motion can lead to misalignment of the PET and computed tomography (CT) data sets and introduce artifacts in the CT-based attenuation correction (AC) of images. In addi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4788669

    authors: Pourmoghaddas A,Klein R,deKemp RA,Wells RG

    更新日期:2013-02-01 00:00:00

  • A time-domain wavelet-based approach for fluorescence diffuse optical tomography.

    abstract:PURPOSE:In the context of fluorescence diffuse optical tomography, determining the optimal way to exploit the time-resolved information has been receiving much attention and different features of the time-resolved signals have been introduced. In this article, the authors revisit and generalize the notion of feature, c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3431571

    authors: Ducros N,Da Silva A,Dinten JM,Seelamantula CS,Unser M,Peyrin F

    更新日期:2010-06-01 00:00:00

  • Tree structured wavelet transform segmentation of microcalcifications in digital mammography.

    abstract::A novel multistage algorithm is proposed for the automatic segmentation of microcalcification clusters (MCCs) in digital mammography. First, a previously reported tree structured nonlinear filter is proposed for suppressing image noise, while preserving image details, to potentially reduce the false positive (FP) dete...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597562

    authors: Qian W,Kallergi M,Clarke LP,Li HD,Venugopal P,Song D,Clark RA

    更新日期:1995-08-01 00:00:00

  • Quantitative CT of lung nodules: dependence of calibration on patient body size, anatomic region, and calibration nodule size for single- and dual-energy techniques.

    abstract::Calcium concentration may be a useful feature for distinguishing benign from malignant lung nodules in computer-aided diagnosis. The calcium concentration can be estimated from the measured CT number of the nodule and a CT number vs calcium concentration calibration line that is derived from CT scans of two or more ca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3148536

    authors: Goodsitt MM,Chan HP,Way TW,Schipper MJ,Larson SC,Christodoulou EG

    更新日期:2009-07-01 00:00:00

  • B-spline active rays segmentation of microcalcifications in mammography.

    abstract::Accurate segmentation of microcalcifications in mammography is crucial for the quantification of morphologic properties by features incorporated in computer-aided diagnosis schemes. A novel segmentation method is proposed implementing active rays (polar-transformed active contours) on B-spline wavelet representation t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2991286

    authors: Arikidis NS,Skiadopoulos S,Karahaliou A,Likaki E,Panayiotakis G,Costaridou L

    更新日期:2008-11-01 00:00:00

  • Experimental study of the relationship between the base impedance and its time derivative in impedance plethysmography.

    abstract::Transthoracic electrical impedance Z consists of a constant baseline component Z0 and the time variable component delta Z such that Z = Z0 + delta Z. The first time derivative of Z has a negative peak, the magnitude of which is (dZ/dt)min. Measurements of 170 volunteers show that (dZ/dt)min is a function of the consta...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594910

    authors: Djordjevich L,Sadove MS

    更新日期:1981-01-01 00:00:00

  • WE-G-211-02: Origins and Development of Magnetic Resonance Imaging.

    abstract::The method of magnetic resonance imaging (MRI) was an extension of nuclear magnetic resonance (NMR) spectroscopy that was enabled by computational systems capable of performing the Fast Fourier Transform. Initially, a diverse group of methods were proposed for producing images with NMR, with the multi-slice spin-warp ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736176

    authors: Clarke G

    更新日期:2012-06-01 00:00:00

  • A multi-institutional study to assess adherence to lung stereotactic body radiotherapy planning goals.

    abstract:PURPOSE:A multi-institutional planning study was performed to evaluate the frequency that current guidelines established by Radiation Therapy Oncology Group (RTOG) protocols and other literature for lung stereotactic body radiotherapy (SBRT) treatments are followed. METHODS:A total of 300 patients receiving lung SBRT ...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4926551

    authors: Woerner A,Roeske JC,Harkenrider MM,Fan J,Aydogan B,Koshy M,Laureckas R,Vali F,Campana M,Surucu M

    更新日期:2015-08-01 00:00:00