B-spline active rays segmentation of microcalcifications in mammography.

Abstract:

:Accurate segmentation of microcalcifications in mammography is crucial for the quantification of morphologic properties by features incorporated in computer-aided diagnosis schemes. A novel segmentation method is proposed implementing active rays (polar-transformed active contours) on B-spline wavelet representation to identify microcalcification contour point estimates in a coarse-to-fine strategy at two levels of analysis. An iterative region growing method is used to delineate the final microcalcification contour curve, with pixel aggregation constrained by the microcalcification contour point estimates. A radial gradient-based method was also implemented for comparative purposes. The methods were tested on a dataset consisting of 149 mainly pleomorphic microcalcification clusters originating from 130 mammograms of the DDSM database. Segmentation accuracy of both methods was evaluated by three radiologists, based on a five-point rating scale. The radiologists' average accuracy ratings were 3.96 +/- 0.77, 3.97 +/- 0.80, and 3.83 +/- 0.89 for the proposed method, and 2.91 +/- 0.86, 2.10 +/- 0.94, and 2.56 +/- 0.76 for the radial gradient-based method, respectively, while the differences in accuracy ratings between the two segmentation methods were statistically significant (Wilcoxon signed-ranks test, p < 0.05). The effect of the two segmentation methods in the classification of benign from malignant microcalcification clusters was also investigated. A least square minimum distance classifier was employed based on cluster features reflecting three morphological properties of individual microcalcifications (area, length, and relative contrast). Classification performance was evaluated by means of the area under ROC curve (Az). The area and length morphologic features demonstrated a statistically significant (Mann-Whitney U-test, p < 0.05) higher patient-based classification performance when extracted from microcalcifications segmented by the proposed method (0.82 +/- 0.06 and 0.86 +/- .05, respectively), as compared to segmentation by the radial gradient-based method (0.71 +/- 0.08 and 0.75 +/- 0.08). The proposed method demonstrates improved segmentation accuracy, fulfilling human visual criteria, and enhances the ability of morphologic features to characterize microcalcification clusters.

journal_name

Med Phys

journal_title

Medical physics

authors

Arikidis NS,Skiadopoulos S,Karahaliou A,Likaki E,Panayiotakis G,Costaridou L

doi

10.1118/1.2991286

subject

Has Abstract

pub_date

2008-11-01 00:00:00

pages

5161-71

issue

11

eissn

0094-2405

issn

2473-4209

journal_volume

35

pub_type

杂志文章
  • Surface imaging for real-time patient respiratory function assessment in intensive care.

    abstract:PURPOSE:Monitoring of physiological parameters is a major concern in Intensive Care Units (ICU) given their role in the assessment of vital organ function. Within this context, one issue is the lack of efficient noncontact techniques for respiratory monitoring. In this paper, we present a novel noncontact solution for ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14557

    authors: Nazir S,Pateau V,Bert J,Clement JF,Fayad H,l'Her E,Visvikis D

    更新日期:2020-10-28 00:00:00

  • MO-D-213CD-04: 4D X-Ray DSA and 4D Fluoroscopy.

    abstract::During the past decade the use of undersampled acquisition and constrained reconstruction have led to significant increases in data acquisition speed, SNR, spatial resolution and temporal resolution in MR imaging. When a separately acquired constraining image is combined with an angiographic time series the traditiona...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735797

    authors: Mistretta C

    更新日期:2012-06-01 00:00:00

  • Patient dose simulations for scanning-beam digital x-ray tomosynthesis of the lungs.

    abstract:PURPOSE:An improved method of image guidance for lung tumor biopsies could help reduce the high rate of false negatives. The aim of this work is to optimize the geometry of the scanning-beam digital tomography system (SBDX) for providing real-time 3D tomographic reconstructions for target verification. The unique geome...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4826159

    authors: Nelson G,Yoon S,Krishna G,Wilfley B,Fahrig R

    更新日期:2013-11-01 00:00:00

  • A method for reducing motion induced errors in T2-weighted magnetic resonance imaging.

    abstract::It is known that motion of an object imaged by magnetic resonance imaging leads to errors and artifacts in the image. This effect is especially important when a pulse sequence with long echo time (TE) and long TR is used to provide T2-weighted images. We have modified the usual spin warp imaging pulse sequence in a wa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596026

    authors: Joseph PM,Shetty A,Bonaroti EA

    更新日期:1987-07-01 00:00:00

  • Improvement of off-axis SABR plan verification results by using adapted dose reconstruction algorithms for the Octavius 4D system.

    abstract:PURPOSE:Stereotactic ablative body radiotherapy (SABR) for lung patients can be performed with volumetric-modulated arc therapy (VMAT) plans using off-axis target geometry to allow treatment in their CBCT verified position. For patient-specific quality assurance measurements using the PTW Octavius 4D phantom (PTW, Frei...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12805

    authors: Jeevanandam P,Agnew CE,Irvine DM,McGarry CK

    更新日期:2018-04-01 00:00:00

  • Correction of microwave-induced thermistor sensor errors.

    abstract::Accurate and reliable thermometry is essential in the development of microwave-induced hyperthermal cancer therapy. While temperature measurements in strong electromagnetic fields usually require special sensors, this does not hold true for interstitial radiator/sensor systems. Miniature thermistors (with metallic lea...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595261

    authors: Samaras GM,Rosenbloom S,Cheung AY

    更新日期:1983-05-01 00:00:00

  • State-of-the-art in two-dimensional ultrasonic transducer array technology.

    abstract::Attention is given to means of sensing ultrasonic energy distributions over an area. Under the restraints appropiate to real-time imaging of deep body organs, piezoelectric arrays offer the most promising method. Adaptation of integrated circuit techniques to array assembly permits very large arrays of small elements ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594247

    authors: Maginness MG,Plummer JD,Beaver WL,Meindl JD

    更新日期:1976-09-01 00:00:00

  • Anatomy-based three-dimensional dose optimization in brachytherapy using multiobjective genetic algorithms.

    abstract::In conventional dose optimization algorithms, in brachytherapy, multiple objectives are expressed in terms of an aggregating function which combines individual objective values into a single utility value, making the problem single objective, prior to optimization. A multiobjective genetic algorithm (MOGA) was develop...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598697

    authors: Lahanas M,Baltas D,Zamboglou N

    更新日期:1999-09-01 00:00:00

  • A residual correction method for high-resolution PET reconstruction with application to on-the-fly Monte Carlo based model of positron range.

    abstract:PURPOSE:The quality of tomographic images is directly affected by the system model being used in image reconstruction. An accurate system matrix is desirable for high-resolution image reconstruction, but it often leads to high computation cost. In this work the authors present a maximum a posteriori reconstruction algo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3284980

    authors: Fu L,Qi J

    更新日期:2010-02-01 00:00:00

  • Four-dimensional (4D) PET/CT imaging of the thorax.

    abstract::We have reported in our previous studies on the methodology, and feasibility of 4D-PET (Gated PET) acquisition, to reduce respiratory motion artifact in PET imaging of the thorax. In this study, we expand our investigation to address the problem of respiration motion in PET/CT imaging. The respiratory motion of four l...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1809778

    authors: Nehmeh SA,Erdi YE,Pan T,Pevsner A,Rosenzweig KE,Yorke E,Mageras GS,Schoder H,Vernon P,Squire O,Mostafavi H,Larson SM,Humm JL

    更新日期:2004-12-01 00:00:00

  • A clinically feasible method for the detection of potential collision in proton therapy.

    abstract:PURPOSE:Potential collision between the patient∕couch and the gantry could delay the start of the treatment and reduce clinical efficiency. The ability to accurately detect possible collisions during the treatment planning phase is desired. Such collision detection should account for the specific proton gantry design, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4760988

    authors: Zou W,Lin H,Plastaras JP,Wang H,Bui V,Vapiwala N,McDonough J,Tochner Z,Both S

    更新日期:2012-11-01 00:00:00

  • Branch order regression for modeling brain vasculature.

    abstract:PURPOSE:Many biological objects, including neuronal dendrites, blood vasculature, airways, phylogenetic trees, produce tree structured data. Current methods of analysis either ignore the complex structure of trees or use distance-based methods which limit the scope of multivariate modeling. METHODS:We propose a branch...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12751

    authors: Roy Choudhury K,Skwerer S

    更新日期:2018-03-01 00:00:00

  • A delivery quality assurance tool based on the actual leaf open times in tomotherapy.

    abstract:PURPOSE:To validate a delivery quality assurance (DQA) protocol for tomotherapy based on the measurement of the leaf open times (LOTs). In addition, to show the correlation between the mean relative LOT discrepancy and the dose deviation in the planning target volume (PTV). MATERIALS AND METHODS:We used a LOT measurem...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14348

    authors: Schopfer M,Bochud FO,Bourhis J,Moeckli R

    更新日期:2020-09-01 00:00:00

  • A template-based approach to semi-quantitative SPECT myocardial perfusion imaging: Independent of normal databases.

    abstract:PURPOSE:Normal patient databases (NPDs) are used to distinguish between normal and abnormal perfusion in SPECT myocardial perfusion imaging (MPI) and have gained wide acceptance in the clinical environment, yet there are limitations to this approach. This study introduces a template-based method for semi-quantitative M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3595112

    authors: Hughes T,Shcherbinin S,Celler A

    更新日期:2011-07-01 00:00:00

  • Single shot MR tagging to quantify local tissue deformation during MRI-guided needle interventions: a feasibility study.

    abstract:PURPOSE:In MRI-guided needle interventions, such as biopsies and brachytherapy, tissue deformation caused by needle movement may result in localization errors and thus hamper the outcome of the procedure. Monitoring the local tissue deformation provides the ability to compensate for it, e.g., by increasing the needle i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3633906

    authors: van den Bosch MR,de Leeuw H,Zwanenburg JJ,Lagendijk JJ,Moerland MA

    更新日期:2011-10-01 00:00:00

  • Compensator quality control with an amorphous silicon EPID.

    abstract::The calibration and quality control of compensators is conventionally performed with an ion chamber in a water-equivalent phantom. In our center, the compensator factor and four off-axis fluence ratios are measured to verify the central axis beam modulation and orientation of the compensator. Here we report the invest...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1584040

    authors: Menon GV,Sloboda RS

    更新日期:2003-07-01 00:00:00

  • Fast iterative algorithms for three-dimensional inverse treatment planning.

    abstract::Three types of iterative algorithms, algebraic inverse treatment planning (AITP), simultaneous iterative inverse treatment planning (SIITP), and iterative least-square inverse treatment planning (ILSITP), differentiated according to their updating sequences, were generalized to three dimension with true beam geometry ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598374

    authors: Xing L,Hamilton RJ,Spelbring D,Pelizzari CA,Chen GT,Boyer AL

    更新日期:1998-10-01 00:00:00

  • A fast GPU-based Monte Carlo simulation of proton transport with detailed modeling of nonelastic interactions.

    abstract:PURPOSE:Very fast Monte Carlo (MC) simulations of proton transport have been implemented recently on graphics processing units (GPUs). However, these MCs usually use simplified models for nonelastic proton-nucleus interactions. Our primary goal is to build a GPU-based proton transport MC with detailed modeling of elast...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4921046

    authors: Wan Chan Tseung H,Ma J,Beltran C

    更新日期:2015-06-01 00:00:00

  • SU-E-T-453: Optimization of Dose Gradient for Gamma Knife Radiosurgery.

    abstract:PURPOSE:The goals of stereotactic radiosurgery (SRS) are the ablation of target tissue and sparing of critical normal tissue. We develop tools to aid in the selection of collimation and prescription (Rx) isodose line to optimize the dose gradient for single isocenter intracranial stereotactic radiosurgery (SRS) with Ga...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735542

    authors: Sheth N,Chen Y,Yang J

    更新日期:2012-06-01 00:00:00

  • Automatic needle segmentation in three-dimensional ultrasound images using two orthogonal two-dimensional image projections.

    abstract::In this paper, we describe an algorithm to segment a needle from a three-dimensional (3D) ultrasound image by using two orthogonal two-dimensional (2D) image projections. Not only is the needle more conspicuous in a projected (volume-rendered) image, but its direction in 3D lies in the plane defined by the projection ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1538231

    authors: Ding M,Cardinal HN,Fenster A

    更新日期:2003-02-01 00:00:00

  • The potential role of positron emission mammography for detection of breast cancer. A phantom study.

    abstract::Positron emission mammography (PEM) is a new, specialized imaging modality utilizing PET radiopharmaceuticals to detect breast cancer. The capabilities and limitations of PEM in detecting breast tumors were investigated with a series of phantom experiments. The PEM imager was mounted on a standard Lorad biopsy table (...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1287439

    authors: Raylman RR,Majewski S,Wojcik R,Weisenberger AG,Kross B,Popov V,Bishop HA

    更新日期:2000-08-01 00:00:00

  • Rotationally resliced 3D prostate TRUS segmentation using convex optimization with shape priors.

    abstract:PURPOSE:Efficient and accurate segmentations of 3D end-firing transrectal ultrasound (TRUS) images play an important role in planning of 3D TRUS guided prostate biopsy. However, poor image quality of the input 3D TRUS images, such as strong imaging artifacts and speckles, often makes it a challenging task to extract th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4906129

    authors: Qiu W,Yuan J,Ukwatta E,Fenster A

    更新日期:2015-02-01 00:00:00

  • SU-D-218-05: Material Quantification in Spectral X-Ray Imaging: Optimization and Validation.

    abstract:PURPOSE:To develop and validate a multivariate statistical method to optimize scanning parameters for material quantification in spectral x-rayimaging. METHODS:An optimization metric was constructed by extensively sampling the thickness space for the expected number of counts for m (two or three) materials. This resul...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734708

    authors: Nik SJ,Thing RS,Watts R,Meyer J

    更新日期:2012-06-01 00:00:00

  • Displacement-based binning of time-dependent computed tomography image data sets.

    abstract::Respiration can cause tumors in the thorax or abdomen to move by as much as 3 cm; this movement can adversely affect the planning and delivery of radiation treatment. Several techniques have been used to compensate for respiratory motion, but all have shortcomings. Manufacturers of computed tomography (CT) equipment h...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2044427

    authors: Fitzpatrick MJ,Starkschall G,Antolak JA,Fu J,Shukla H,Keall PJ,Klahr P,Mohan R

    更新日期:2006-01-01 00:00:00

  • Application of the TRS 483 code of practice for reference and relative dosimetry in tomotherapy.

    abstract:PURPOSE:To apply the recent code of practice from the IAEA/AAPM, TRS 483, to helical tomotherapy (HT) for reference and relative dosimetry obtaining correction factors for the Exradin A1SL ionization chamber. METHODS:The beam quality correction factor for the A1SL chamber was obtained through three different approache...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13855

    authors: Lopes MDC,Santos T,Ventura T,Capela M

    更新日期:2019-12-01 00:00:00

  • The dosimetric properties of an intraoperative radiation therapy applicator system for a Mevatron-80.

    abstract::An applicator system for intraoperative radiation therapy has been fabricated which does not require physical docking with the accelerator. A dosimetric study has been completed which documents the properties of this system for a variety of electron beam energies, applicator sizes, collimator settings, both primary an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596338

    authors: Nelson CE,Cook R,Rakfal S

    更新日期:1989-09-01 00:00:00

  • Registration of clinical volumes to beams-eye-view images for real-time tracking.

    abstract:PURPOSE:The authors combine the registration of 2D beam's eye view (BEV) images and 3D planning computed tomography (CT) images, with relative, markerless tumor tracking to provide automatic absolute tracking of physician defined volumes such as the gross tumor volume (GTV). METHODS:During treatment of lung SBRT cases...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4900603

    authors: Bryant JH,Rottmann J,Lewis JH,Mishra P,Keall PJ,Berbeco RI

    更新日期:2014-12-01 00:00:00

  • Fast dose optimization for rotating shield brachytherapy.

    abstract:PURPOSE:To provide a fast computational method, based on the proximal graph solver (POGS) - A convex optimization solver using the alternating direction method of multipliers (ADMM), for calculating an optimal treatment plan in rotating shield brachytherapy (RSBT). RSBT treatment planning has more degrees of freedom th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12486

    authors: Cho M,Wu X,Dadkhah H,Yi J,Flynn RT,Kim Y,Xu W

    更新日期:2017-10-01 00:00:00

  • Measurement of neutron ambient dose equivalent in passive carbon-ion and proton radiotherapies.

    abstract::Secondary neutron ambient dose equivalents per the treatment absorbed dose in passive carbon-ion and proton radiotherapies were measured using a rem meter, WENDI-II at two carbon-ion radiotherapy facilities and four proton radiotherapy facilities in Japan. Our measured results showed that (1) neutron ambient dose equi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2989019

    authors: Yonai S,Matsufuji N,Kanai T,Matsui Y,Matsushita K,Yamashita H,Numano M,Sakae T,Terunuma T,Nishio T,Kohno R,Akagi T

    更新日期:2008-11-01 00:00:00

  • Technical Note: Experimental determination of the effective point of measurement of two cylindrical ionization chambers in a clinical proton beam.

    abstract:PURPOSE:IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4921617

    authors: Sugama Y,Nishio T,Onishi H

    更新日期:2015-07-01 00:00:00