Abstract:
:An applicator system for intraoperative radiation therapy has been fabricated which does not require physical docking with the accelerator. A dosimetric study has been completed which documents the properties of this system for a variety of electron beam energies, applicator sizes, collimator settings, both primary and secondary, and source-surface distance (SSD) settings. Sensitivity of the system to common misalignment errors was also determined. Results indicate (a) applicator leakage of less than 5%, (b) beam flatness to within plus or minus 5% at the dMAX with a single primary collimator setting, (c) smooth changes in output with cone size, beam energy and SSD, and (d) negligible changes in dose distributions within alignment errors permitted by the system.
journal_name
Med Physjournal_title
Medical physicsauthors
Nelson CE,Cook R,Rakfal Sdoi
10.1118/1.596338subject
Has Abstractpub_date
1989-09-01 00:00:00pages
794-9issue
5eissn
0094-2405issn
2473-4209journal_volume
16pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Reconstruction of electron spectra of medical accelerators from measured depth dose distributions is an attractive tool for commissioning of a Monte Carlo treatment planning system. However, the reconstruction method is an inverse radiation transport problem which is poorly conditioned, in the sense it may become unst...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1461840
更新日期:2002-04-01 00:00:00
abstract::Consensus has been developing over the past few decades on a number of measurements required for the laboratory assessment of medical imaging modalities. Nevertheless, understanding of the connection between these measurements and human observer performance in a broad range of tasks remains far from complete. Focusing...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.597511
更新日期:1995-07-01 00:00:00
abstract::The proper evaluation of the accuracy of a new computer program for radiation-therapy dosimetry requires consideration of both the mathematical algorithm used in the program and the performance required in clinical applications. As an example, our evaluation of the irregular-fields dosimetry program currently marketed...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594344
更新日期:1977-11-01 00:00:00
abstract::The aim of this study is to perform a statistical analysis to verify the calculated percentage depth dose (PDD) based on the tissue maximum ratio (TMR) with the PDD measurements taken in water. 6 and 15 MV photon beams produced by a Varian linear 2100 C/D accelerator were used. PDDs and TMRs were measured at various d...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740131
更新日期:2012-07-01 00:00:00
abstract::Quantification of transit time of a remote after-loading high dose rate (HDR) brachytherapy source is important both for accurate treatment planning and for quality assurance checks. In this investigation, an HDR-1000 well ionization chamber and a precision electrometer are used to measure the transit time of the Ir-1...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1386779
更新日期:2001-08-01 00:00:00
abstract:PURPOSE:This paper presents the application of MAGIC-f gel in a three-dimensional dose distribution measurement and its ability to accurately measure the dose distribution from a tomotherapy unit. METHODS:A prostate intensity-modulated radiation therapy (IMRT) irradiation was simulated in the gel phantom and the treat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4704496
更新日期:2012-05-01 00:00:00
abstract::Due to practical limitations such as inter- and intraleaf transmission, nondivergent leaf end design, and leaf scatter, multileaf collimators (MLCs) are unable to accurately produce the ideal fluence patterns generated by inverse planning systems. Consequently, low dose regions receive substantially more radiation tha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2779862
更新日期:2007-10-01 00:00:00
abstract::An addendum to the AAPM's TG-51 protocol for the determination of absorbed dose to water in megavoltage photon beams is presented. This addendum continues the procedure laid out in TG-51 but new kQ data for photon beams, based on Monte Carlo simulations, are presented and recommendations are given to improve the accur...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4866223
更新日期:2014-04-01 00:00:00
abstract:PURPOSE:A detailed analysis of 2728 intensity modulated proton therapy (IMPT) fields that were clinically delivered to patients between 2007 and 2013 at Paul Scherrer Institute (PSI) was performed. The aim of this study was to analyze the results of patient specific dosimetric verifications and to assess possible corre...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4964449
更新日期:2016-11-01 00:00:00
abstract:PURPOSE:Carpal tunnel syndrome (CTS) is the common entrapment neuropathy that occurs due to compression of the median nerve at the wrist. Ultrasound images have been used to highlight anatomical variants of the median nerve, and CTS is thought to be associated to enlargement of the cross-sectional area (CSA) of the med...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4767754
更新日期:2012-12-01 00:00:00
abstract:PURPOSE:Respiratory gating in PET is an approach used to minimize the negative effects of respiratory motion on spatial resolution. It is based on an initial determination of a patient's respiratory movements during a scan, typically using hardware based systems. In recent years, several fully automated databased algor...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3483784
更新日期:2010-10-01 00:00:00
abstract:PURPOSE:The response of human cells to applied electrical signals depends on the cellular health status, because it is influenced by the composition and structure of the main cellular components. Therefore, electrical impedance-based techniques can be considered as sensitive tools to investigate healthy or disease stat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14425
更新日期:2020-10-01 00:00:00
abstract:OBJECTIVE:Carbon ion particle therapy delivers sharp Bragg's peaks, and hence can produce dose delivery of very high precision and conformality. To complement this characteristic, particle therapy centers implement a number of technologies unique to these centers, and are not commonly known to the medical physics commu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735351
更新日期:2012-06-01 00:00:00
abstract::Calibration of an imported strontium-90 ophthalmic applicator at the U.S. National Bureau of Standards (now the National Institute of Standards and Technology) has disclose a significant discrepancy in dose rate calibration (32%-35%) with that quoted by the manufacturer. The University of Wisconsin has investigated th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596702
更新日期:1991-03-01 00:00:00
abstract:PURPOSE:To reduce image noise and radiation dose in Digital Breast Tomosynthesis (DBT) reconstructions. METHODS:A retrospective study was performed on clinical data sets acquired at a normal dose with Hologic Selenia Dimensions DBT systems. The Prior Image Constrained Compressed Sensing (PICCS) algorithm was used to r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735982
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The objective of this study is to evaluate requirements for radionuclide-based solid tumor therapy by assessing the radial dose distribution of beta-particle-emitting and alpha-particle-emitting molecules localized either solely within endothelial cells of tumor vasculature or diffusing from the vasculature thr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3431999
更新日期:2010-06-01 00:00:00
abstract:PURPOSE:To characterize the modulation transfer function (MTF) of proton/carbon radiography using Monte Carlo simulations. To assess the spatial resolution of proton/carbon radiographic imaging. METHODS:A phantom was specifically modeled with inserts composed of two materials with three different densities of bone and...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4819816
更新日期:2013-09-01 00:00:00
abstract::We are evaluating the usefulness of stereomammography in improving breast cancer diagnosis. One area that we are investigating is whether the improved depth perception associated with stereomammography might be significantly enhanced with the use of a virtual 3D cursor. A study was performed to evaluate the accuracy o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.599008
更新日期:2000-06-01 00:00:00
abstract::Intensity modulated radiotherapy (IMRT) requires extensive knowledge of multileaf collimator (MLC) leaf positioning accuracy, precision, and long-term reproducibility. We have developed a technique to efficiently measure the absolute position of each MLC leaf, over the range of leaf positions utilized in IMRT, based o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1564091
更新日期:2003-05-01 00:00:00
abstract::The last 50 years have seen great advances in the accuracy of external beam radiation therapy. Geometrical uncertainties have been reduced from a centimeter or more in presimulation, skin-mark guided days to 1-2 mm in today's image-guided radiation therapy treatments. Medical physicists, with the support and guidance ...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.2836420
更新日期:2008-03-01 00:00:00
abstract:PURPOSE:The local depth dose gradient and the displacement correction factor for Farmer-type ionization chambers are quantified for reference dosimetry at shallow depth in single-layer scanned proton fields. METHOD:Integrated radial profiles as a function of depth (IRPDs) measured at three proton therapy centers were ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14554
更新日期:2020-12-01 00:00:00
abstract:PURPOSE:The Monte Carlo simulation of electron transport in Linac targets using the condensed history technique is known to be problematic owing to a potential dependence of absorbed dose distributions on the electron step length. In the PENELOPE code, the step length is partially determined by the transport parameters...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4916686
更新日期:2015-06-01 00:00:00
abstract:PURPOSE:To implement the DMAIC (Define-Measure-Analyze-Improve-Control) can be used for customizing the patient-specific QA by designing site-specific range tolerances. METHODS:The DMAIC framework (process flow diagram, cause and effect, Pareto chart, control chart, and capability analysis) were utilized to determine ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12721
更新日期:2018-02-01 00:00:00
abstract::Accurate segmentation of microcalcifications in mammography is crucial for the quantification of morphologic properties by features incorporated in computer-aided diagnosis schemes. A novel segmentation method is proposed implementing active rays (polar-transformed active contours) on B-spline wavelet representation t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2991286
更新日期:2008-11-01 00:00:00
abstract::Estimates of the effective dose to adult patients from computed tomography (CT) head scanning can be calculated using a number of different methods. These estimates can be used for a variety of purposes, such as improving scanning protocols, comparing different CT imaging centers, and weighing the benefits of the scan...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2952359
更新日期:2008-08-01 00:00:00
abstract::The objective of this study was to compare the contrast-detail performance of five different commercial liquid crystal displays (LCDs) to other LCD and cathode-ray tube (CRT) displays for medical applications. A contrast-detail phantom, supplemented with 5 in. of acrylic, was imaged on a commercial digital radiographi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2868780
更新日期:2008-04-01 00:00:00
abstract:PURPOSE:To balance dose reduction and image registration accuracy in breast setup imaging. In particular, the authors demonstrate the relationship between scan angle and dose delivery for cone beam tomosynthesis (CBTS) when employed for setup verification of breast cancer patients with surgical clips. METHODS:The dose...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3464716
更新日期:2010-08-01 00:00:00
abstract::Stereotactic X-ray mammography (SM) and ultrasound (US) guidance are both commonly used for breast biopsy. While SM provides three-dimensional (3D) targeting information and US provides real-time guidance, both have limitations. SM is a long and uncomfortable procedure and the US guided procedure is inherently two dim...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2794175
更新日期:2007-11-01 00:00:00
abstract:PURPOSE:Currently, no 3D or 4D volumetric x-ray imaging techniques are available for intrafraction verification of target position during actual treatment delivery or in-between treatment beams, which is critical for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) treatments. This study a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4861820
更新日期:2014-02-01 00:00:00
abstract::The noise power spectrum (NPS) is a useful metric for understanding the noise content in images. To examine some unique properties of the NPS of fan beam CT, the authors derived an analytical expression for the NPS of fan beam CT and validated it with computer simulations. The nonstationary noise behavior of fan beam ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3378673
更新日期:2010-05-01 00:00:00