A comparative contrast-detail study of five medical displays.

Abstract:

:The objective of this study was to compare the contrast-detail performance of five different commercial liquid crystal displays (LCDs) to other LCD and cathode-ray tube (CRT) displays for medical applications. A contrast-detail phantom, supplemented with 5 in. of acrylic, was imaged on a commercial digital radiographic system using techniques comparable to chest radiography. The phantom design enabled observer evaluation by a four-alternative forced choice paradigm. The acquired images were independently scored by five observers on five medical display devices: a 5 megapixel monochrome LCD, a 3 megapixel monochrome LCD, a 9 megapixel color LCD, a 5 megapixel monochrome CRT, and a mammographic-grade monochrome CRT. The data were analyzed using the method suggested by the manufacturer based on a nearest neighbor correction technique. They were further analyzed using a logistic regression response model with a natural threshold using an overall chi-square test for display type followed by pairwise comparisons for individual display performance. The differences between the display devices were small. The standard analysis of the results based on the manufacturer-recommended method did not yield any statistically discernible trend among displays. The logistic regression analysis, however, indicated that the 5 megapixel monochrome LCD was statistically significantly (p <0.0001) superior to the others, followed by the 3 megapixel monochrome LCD (p<0.0001). The three other displays exhibited lower but generally similar performance characteristics. The findings suggest that 5 and 3 megapixel monochrome LCDs provide comparable but subtly superior contrast detectability than other tested displays, with the former performing slightly better in the detection of subtle and fine details.

journal_name

Med Phys

journal_title

Medical physics

authors

Samei E,Ranger NT,Delong DM

doi

10.1118/1.2868780

subject

Has Abstract

pub_date

2008-04-01 00:00:00

pages

1358-64

issue

4

eissn

0094-2405

issn

2473-4209

journal_volume

35

pub_type

杂志文章
  • Monte Carlo and experimental dosimetry of an 1251 brachytherapy seed.

    abstract::We have performed a comprehensive dosimetric characterization of the Oncura model 6711 125I seed using both experimental [LiF thermoluminscent dosimetry (TLD)] and theoretical (Monte Carlo photon transport) methods. In addition to determining the dosimetric parameters of the 6711, this report quantified: (1) the angul...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2388158

    authors: Dolan J,Lia Z,Williamson JF

    更新日期:2006-12-01 00:00:00

  • Practical cone-beam lambda tomography.

    abstract::As a potentially important technology for medical x-ray computed tomography (CT), lambda tomography (LT) is to reconstruct a gradient-like image only from local projection data. Based on our recently derived exact fan-beam LT formula, [H. Y. Gu and G. Wang, Int. J. Biomed. Imaging 2006(1), 1-9 (2006)] here we propose ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2348767

    authors: Yu H,Ye Y,Wang G

    更新日期:2006-10-01 00:00:00

  • SU-E-I-108: Simple Approach to Determine Patient's Entrance Skin Exposure for Radiographic.

    abstract:PURPOSE:To evaluate a model which can predict patient's Entrance Skin Exposure (ESE) from height and weight and a single kVp mR/mAs measurement for radiographic. METHODS:Patient height, weight and post exposure mAs are obtained to assess ESE based on IAEA model. Patient's thickness is obtained by assuming a cylindrica...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734825

    authors: Maricle S,Jeutang L,Prasad G

    更新日期:2012-06-01 00:00:00

  • A filtering method for signal equalization in region-of-interest fluoroscopy.

    abstract::A method to significantly reduce the exposure area product in fluoroscopy using a pre-patient region-of-interest (ROI) attenuator is presented. The attenuator has a thin central region and a gradually increasing thickness away from the center. It is shown that the unwanted brightening artifact caused by the attenuator...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1470205

    authors: Robert N,Komljenovic PT,Rowlands JA

    更新日期:2002-05-01 00:00:00

  • Verification of IMRT dose distributions using a water beam imaging system.

    abstract::A water beam imaging system (WBIS) has been developed and used to verify dose distributions for intensity modulated radiotherapy using dynamic multileaf collimator. This system consisted of a water container, a scintillator screen, a charge-coupled device camera, and a portable personal computer. The scintillation ima...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1413519

    authors: Li JS,Boyer AL,Ma CM

    更新日期:2001-12-01 00:00:00

  • Technical Note: Study of the electron transport parameters used in PENELOPE for the Monte Carlo simulation of Linac targets.

    abstract:PURPOSE:The Monte Carlo simulation of electron transport in Linac targets using the condensed history technique is known to be problematic owing to a potential dependence of absorbed dose distributions on the electron step length. In the PENELOPE code, the step length is partially determined by the transport parameters...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4916686

    authors: Rodriguez M,Sempau J,Brualla L

    更新日期:2015-06-01 00:00:00

  • Normalization (division) versus subtraction of digitized images.

    abstract::The propagation of noise in digitized images arrived at by algebraic manipulation of two images has been investigated. The algebraic manipulations investigated were logarithmic subtraction, linear subtraction, and division of the two images. The two images were identical except for the presence of a contrast-adding co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595289

    authors: Baily NA,Rimkus D,Nalcioglu O

    更新日期:1983-01-01 00:00:00

  • Use of local noise power spectrum and wavelet analysis in quantitative image quality assurance for EPIDs.

    abstract:PURPOSE:To investigate the use of local noise power spectrum (NPS) to characterize image noise and wavelet analysis to isolate defective pixels and inter-subpanel flat-fielding artifacts for quantitative quality assurance (QA) of electronic portal imaging devices (EPIDs). METHODS:A total of 93 image sets including cus...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4959541

    authors: Lee S,Yan G,Bassett P,Gopal A,Samant S

    更新日期:2016-09-01 00:00:00

  • Validation of the Gatortail method for accurate sizing of pulmonary vessels from 3D medical images.

    abstract:PURPOSE:Detailed characterization of changes in vessel size is crucial for the diagnosis and management of a variety of vascular diseases. Because clinical measurement of vessel size is typically dependent on the radiologist's subjective interpretation of the vessel borders, it is often prone to high inter- and intra-u...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12580

    authors: O'Dell WG,Gormaley AK,Prida DA

    更新日期:2017-12-01 00:00:00

  • Region-oriented CT image representation for reducing computing time of Monte Carlo simulations.

    abstract:PURPOSE:We propose a new method for efficient particle transportation in voxelized geometry for Monte Carlo simulations. We describe its use for calculating dose distribution in CT images for radiation therapy. MATERIAL AND METHODS:The proposed approach, based on an implicit volume representation named segmented volum...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2884854

    authors: Sarrut D,Guigues L

    更新日期:2008-04-01 00:00:00

  • Automatic quantitative low contrast analysis of digital chest phantom radiographs.

    abstract::Up to the present, the majority of low contrast object evaluations performed on phantom images have been accomplished in a subjective fashion. This is mainly due to the time and effort required to manually measure each radiograph with a densitometer to obtain quantitative results. However, with the development of digi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1543153

    authors: Kwan AL,Filipow LJ,Le LH

    更新日期:2003-03-01 00:00:00

  • A new approach to CT pixel-based photon dose calculations in heterogeneous media.

    abstract::The effects of small cavities on dose in water and the dose in a homogeneous nonunit density medium illustrate that inhomogeneities do not act independently in photon dose perturbation, and serve as two constraints which should be satisfied by approximate methods of computed tomography (CT) pixel-based dose calculatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595294

    authors: Wong JW,Henkelman RM

    更新日期:1983-03-01 00:00:00

  • Investigation of the use of MOSFET for clinical IMRT dosimetric verification.

    abstract::(Received 22 October 2001; accepted for publication 26 March 2002; published 22 May 2002) With advanced conformal radiotherapy using intensity modulated beams, it is important to have radiation dose verification measurements prior to treatment. Metal oxide semiconductor field effect transistors (MOSFET) have the advan...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1481520

    authors: Chuang CF,Verhey LJ,Xia P

    更新日期:2002-06-01 00:00:00

  • Technical note: patient-specific quality assurance methods for TomoDirect(TM) whole breast treatment delivery.

    abstract:PURPOSE:To investigate the feasibility of implementing a novel approach for patient-specific QA of TomoDirect(TM) whole breast treatment. METHODS:The most currently used TomoTherapy DQA method, consisting in the verification of the 2D dose distribution in a coronal or sagittal plane of the Cheese Phantom by means of g...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4722967

    authors: Catuzzo P,Zenone F,Aimonetto S,Peruzzo A,Casanova Borca V,Pasquino M,Franco P,La Porta MR,Ricardi U,Tofani S

    更新日期:2012-07-01 00:00:00

  • A multiple detector array helical x-ray microtomography system for specimen imaging.

    abstract::An x-ray computed microtomography system for specimen and small animal imaging was built and tested. The system used seventeen 48-microm-wide detector arrays (a charge coupled device camera) and helical acquisition techniques. Images were acquired using 540 rays/view and 400 views/2pi. The modulation transfer function...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598662

    authors: Corrigan NM,Chavez AE,Wisner ER,Boone JM

    更新日期:1999-08-01 00:00:00

  • MO-A-217BCD-01: Internal Emitter Dose Estimation.

    abstract::Tissue absorbed dose (D) is a computed result for internal emitters. For fixed geometries, D is calculated by a matrix (S) multiplication of the integrated activity vector (Ã). The last quantity is usually measured by nuclear imaging of activity in various source organs and performing a temporal integration. Ã is the ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735750

    authors: Williams L

    更新日期:2012-06-01 00:00:00

  • Development and validation of a measurement-based source model for kilovoltage cone-beam CT Monte Carlo dosimetry simulations.

    abstract:PURPOSE:The purpose of this study is to adapt an equivalent source model originally developed for conventional CT Monte Carlo dose quantification to the radiation oncology context and validate its application for evaluating concomitant dose incurred by a kilovoltage (kV) cone-beam CT (CBCT) system integrated into a lin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4823795

    authors: McMillan K,McNitt-Gray M,Ruan D

    更新日期:2013-11-01 00:00:00

  • High-speed photography during ultrasound illustrates potential therapeutic applications of microbubbles.

    abstract::Ultrasound contrast agents consist of microscopically small encapsulated bubbles that oscillate upon insonification. To enhance diagnostic ultrasound imaging techniques and to explore therapeutic applications, these medical microbubbles have been studied with the aid of high-speed photography. We filmed medical microb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2133718

    authors: Postema M,van Wamel A,ten Cate FJ,de Jong N

    更新日期:2005-12-01 00:00:00

  • A quality management program in intravascular brachytherapy.

    abstract::While simple, intravascular brachytherapy (IVB) presents a considerable potential for harm to the patient. The medical physicist maintains the responsibility to minimize the likelihood of operational problems or dosimetric errors. The principals for safe operation remain the same as with any radiotherapy treatment: to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1524167

    authors: Chakri A,Thomadsen B

    更新日期:2002-12-01 00:00:00

  • A data-mining framework for large scale analysis of dose-outcome relationships in a database of irradiated head and neck cancer patients.

    abstract:PURPOSE:To develop a hypothesis-generating framework for automatic extraction of dose-outcome relationships from an in-house, analytic oncology database. METHODS:Dose-volume histograms (DVH) and clinical outcomes have been routinely stored to the authors' database for 684 head and neck cancer patients treated from 200...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4922686

    authors: Robertson SP,Quon H,Kiess AP,Moore JA,Yang W,Cheng Z,Afonso S,Allen M,Richardson M,Choflet A,Sharabi A,McNutt TR

    更新日期:2015-07-01 00:00:00

  • Determining the energy spectrum of clinical linear accelerator using an optimized photon beam transmission protocol.

    abstract:PURPOSE:The complex beam delivery techniques for patient treatment using a clinical linear accelerator (linac) may result in variations in the photon spectra, which can lead to dosimetric differences in patients that cannot be accounted for by current treatment planning systems (TPSs). Therefore, precise knowledge of t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13569

    authors: Choi HJ,Park H,Yi CY,Kim BC,Shin WG,Min CH

    更新日期:2019-07-01 00:00:00

  • Correcting TG 119 confidence limits.

    abstract:PURPOSE:Task Group 119 (TG-119) has been adopted for evaluating the adequacy of intensity-modulated radiation therapy (IMRT) commissioning and for establishing patient-specific IMRT quality assurance (QA) passing criteria in clinical practice. TG-119 establishes 95% confidence limits (CLs), which help clinics identify ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12759

    authors: Kearney V,Solberg T,Jensen S,Cheung J,Chuang C,Valdes G

    更新日期:2018-03-01 00:00:00

  • An investigation of a new amorphous silicon electronic portal imaging device for transit dosimetry.

    abstract::The relationship between the pixel value and exit dose was investigated for a new commercially available amorphous silicon electronic portal imaging device. The pixel to dose mapping function was established to be linear for detector distances between 116.5 cm to 150 cm from the source, radiation field sizes from 5 x ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1508108

    authors: Grein EE,Lee R,Luchka K

    更新日期:2002-10-01 00:00:00

  • Radiation attenuation by lead and nonlead materials used in radiation shielding garments.

    abstract::The attenuating properties of several types of lead (Pb)-based and non-Pb radiation shielding materials were studied and a correlation was made of radiation attenuation, materials properties, calculated spectra and ambient dose equivalent. Utilizing the well-characterized x-ray and gamma ray beams at the National Rese...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2426404

    authors: McCaffrey JP,Shen H,Downton B,Mainegra-Hing E

    更新日期:2007-02-01 00:00:00

  • WE-G-217A-08: Routine ACR SNR Measurement Failed to Detect 32-Channel Head Coil Receiver Malfunction.

    abstract:PURPOSE:To study if malfunction of a receiver can be detected robustly using the simple ACR SNR measurement approach on a 32-channel head coil. METHODS:Standard ACR T1W images (11slice) were acquired with a commercial 32 channel head coil on a 3T Philips Achieva MR scanner following the ACR recommended setup. Raw data...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736227

    authors: Peng Q

    更新日期:2012-06-01 00:00:00

  • Absolute dosimetry of a 1.5 T MR-guided accelerator-based high-energy photon beam in water and solid phantoms using Aerrow.

    abstract:PURPOSE:In this work, the fabrication, operation, and evaluation of a probe-format graphite calorimeter - herein referred to as Aerrow - as an absolute clinical dosimeter of high-energy photon beams while in the presence of a B = 1.5 T magnetic field is described. Comparable to a cylindrical ionization chamber (IC) in ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13968

    authors: Renaud J,Sarfehnia A,Bancheri J,Seuntjens J

    更新日期:2020-03-01 00:00:00

  • Use of capillary optics as a beam intensifier for a Compton x-ray source.

    abstract::The use of Kumakhov capillary optics will significantly enhance the performance of near-monochromatic, Compton backscattered x-ray programs. The Vanderbilt University Medical Free-Electron Laser Center is developing the capability to create these tunable x rays for medical imaging. The present transport has only refle...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597218

    authors: Tompkins PA,Abreu CC,Carroll FE,Xiao QF,MacDonald CA

    更新日期:1994-11-01 00:00:00

  • Study of the secondary neutral radiation in proton therapy: toward an indirect in vivo dosimetry.

    abstract:PURPOSE:Secondary particles produced in the collision of protons with beam modifiers are of concern in proton therapy. Nevertheless, secondary radiation can provide information on the dosimetric parameters through its dependency on the modulating accessories (range shifter and range modulating wheel). Relatively little...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4765049

    authors: Carnicer A,Letellier V,Rucka G,Angellier G,Sauerwein W,Herault J

    更新日期:2012-12-01 00:00:00

  • Stereomammography: evaluation of depth perception using a virtual 3D cursor.

    abstract::We are evaluating the usefulness of stereomammography in improving breast cancer diagnosis. One area that we are investigating is whether the improved depth perception associated with stereomammography might be significantly enhanced with the use of a virtual 3D cursor. A study was performed to evaluate the accuracy o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.599008

    authors: Goodsitt MM,Chan HP,Hadjiiski L

    更新日期:2000-06-01 00:00:00

  • Verification of radiotherapy treatments: computerized analysis of the size and shape of radiation fields.

    abstract::An automated technique has been developed for the verification of treatment field size and shape in external beam radiation therapy. Portal images from film or digital on-line imaging system are analyzed, and basic parameters are derived to describe the field size and shape from the contour points on the field boundar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597017

    authors: Leszczynski KW,Shalev S,Gluhchev G

    更新日期:1993-05-01 00:00:00