Abstract:
:The objective of this study was to compare the contrast-detail performance of five different commercial liquid crystal displays (LCDs) to other LCD and cathode-ray tube (CRT) displays for medical applications. A contrast-detail phantom, supplemented with 5 in. of acrylic, was imaged on a commercial digital radiographic system using techniques comparable to chest radiography. The phantom design enabled observer evaluation by a four-alternative forced choice paradigm. The acquired images were independently scored by five observers on five medical display devices: a 5 megapixel monochrome LCD, a 3 megapixel monochrome LCD, a 9 megapixel color LCD, a 5 megapixel monochrome CRT, and a mammographic-grade monochrome CRT. The data were analyzed using the method suggested by the manufacturer based on a nearest neighbor correction technique. They were further analyzed using a logistic regression response model with a natural threshold using an overall chi-square test for display type followed by pairwise comparisons for individual display performance. The differences between the display devices were small. The standard analysis of the results based on the manufacturer-recommended method did not yield any statistically discernible trend among displays. The logistic regression analysis, however, indicated that the 5 megapixel monochrome LCD was statistically significantly (p <0.0001) superior to the others, followed by the 3 megapixel monochrome LCD (p<0.0001). The three other displays exhibited lower but generally similar performance characteristics. The findings suggest that 5 and 3 megapixel monochrome LCDs provide comparable but subtly superior contrast detectability than other tested displays, with the former performing slightly better in the detection of subtle and fine details.
journal_name
Med Physjournal_title
Medical physicsauthors
Samei E,Ranger NT,Delong DMdoi
10.1118/1.2868780subject
Has Abstractpub_date
2008-04-01 00:00:00pages
1358-64issue
4eissn
0094-2405issn
2473-4209journal_volume
35pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::We have performed a comprehensive dosimetric characterization of the Oncura model 6711 125I seed using both experimental [LiF thermoluminscent dosimetry (TLD)] and theoretical (Monte Carlo photon transport) methods. In addition to determining the dosimetric parameters of the 6711, this report quantified: (1) the angul...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2388158
更新日期:2006-12-01 00:00:00
abstract::As a potentially important technology for medical x-ray computed tomography (CT), lambda tomography (LT) is to reconstruct a gradient-like image only from local projection data. Based on our recently derived exact fan-beam LT formula, [H. Y. Gu and G. Wang, Int. J. Biomed. Imaging 2006(1), 1-9 (2006)] here we propose ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2348767
更新日期:2006-10-01 00:00:00
abstract:PURPOSE:To evaluate a model which can predict patient's Entrance Skin Exposure (ESE) from height and weight and a single kVp mR/mAs measurement for radiographic. METHODS:Patient height, weight and post exposure mAs are obtained to assess ESE based on IAEA model. Patient's thickness is obtained by assuming a cylindrica...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734825
更新日期:2012-06-01 00:00:00
abstract::A method to significantly reduce the exposure area product in fluoroscopy using a pre-patient region-of-interest (ROI) attenuator is presented. The attenuator has a thin central region and a gradually increasing thickness away from the center. It is shown that the unwanted brightening artifact caused by the attenuator...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1470205
更新日期:2002-05-01 00:00:00
abstract::A water beam imaging system (WBIS) has been developed and used to verify dose distributions for intensity modulated radiotherapy using dynamic multileaf collimator. This system consisted of a water container, a scintillator screen, a charge-coupled device camera, and a portable personal computer. The scintillation ima...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1413519
更新日期:2001-12-01 00:00:00
abstract:PURPOSE:The Monte Carlo simulation of electron transport in Linac targets using the condensed history technique is known to be problematic owing to a potential dependence of absorbed dose distributions on the electron step length. In the PENELOPE code, the step length is partially determined by the transport parameters...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4916686
更新日期:2015-06-01 00:00:00
abstract::The propagation of noise in digitized images arrived at by algebraic manipulation of two images has been investigated. The algebraic manipulations investigated were logarithmic subtraction, linear subtraction, and division of the two images. The two images were identical except for the presence of a contrast-adding co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595289
更新日期:1983-01-01 00:00:00
abstract:PURPOSE:To investigate the use of local noise power spectrum (NPS) to characterize image noise and wavelet analysis to isolate defective pixels and inter-subpanel flat-fielding artifacts for quantitative quality assurance (QA) of electronic portal imaging devices (EPIDs). METHODS:A total of 93 image sets including cus...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4959541
更新日期:2016-09-01 00:00:00
abstract:PURPOSE:Detailed characterization of changes in vessel size is crucial for the diagnosis and management of a variety of vascular diseases. Because clinical measurement of vessel size is typically dependent on the radiologist's subjective interpretation of the vessel borders, it is often prone to high inter- and intra-u...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12580
更新日期:2017-12-01 00:00:00
abstract:PURPOSE:We propose a new method for efficient particle transportation in voxelized geometry for Monte Carlo simulations. We describe its use for calculating dose distribution in CT images for radiation therapy. MATERIAL AND METHODS:The proposed approach, based on an implicit volume representation named segmented volum...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2884854
更新日期:2008-04-01 00:00:00
abstract::Up to the present, the majority of low contrast object evaluations performed on phantom images have been accomplished in a subjective fashion. This is mainly due to the time and effort required to manually measure each radiograph with a densitometer to obtain quantitative results. However, with the development of digi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1543153
更新日期:2003-03-01 00:00:00
abstract::The effects of small cavities on dose in water and the dose in a homogeneous nonunit density medium illustrate that inhomogeneities do not act independently in photon dose perturbation, and serve as two constraints which should be satisfied by approximate methods of computed tomography (CT) pixel-based dose calculatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595294
更新日期:1983-03-01 00:00:00
abstract::(Received 22 October 2001; accepted for publication 26 March 2002; published 22 May 2002) With advanced conformal radiotherapy using intensity modulated beams, it is important to have radiation dose verification measurements prior to treatment. Metal oxide semiconductor field effect transistors (MOSFET) have the advan...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1481520
更新日期:2002-06-01 00:00:00
abstract:PURPOSE:To investigate the feasibility of implementing a novel approach for patient-specific QA of TomoDirect(TM) whole breast treatment. METHODS:The most currently used TomoTherapy DQA method, consisting in the verification of the 2D dose distribution in a coronal or sagittal plane of the Cheese Phantom by means of g...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4722967
更新日期:2012-07-01 00:00:00
abstract::An x-ray computed microtomography system for specimen and small animal imaging was built and tested. The system used seventeen 48-microm-wide detector arrays (a charge coupled device camera) and helical acquisition techniques. Images were acquired using 540 rays/view and 400 views/2pi. The modulation transfer function...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598662
更新日期:1999-08-01 00:00:00
abstract::Tissue absorbed dose (D) is a computed result for internal emitters. For fixed geometries, D is calculated by a matrix (S) multiplication of the integrated activity vector (Ã). The last quantity is usually measured by nuclear imaging of activity in various source organs and performing a temporal integration. Ã is the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735750
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The purpose of this study is to adapt an equivalent source model originally developed for conventional CT Monte Carlo dose quantification to the radiation oncology context and validate its application for evaluating concomitant dose incurred by a kilovoltage (kV) cone-beam CT (CBCT) system integrated into a lin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4823795
更新日期:2013-11-01 00:00:00
abstract::Ultrasound contrast agents consist of microscopically small encapsulated bubbles that oscillate upon insonification. To enhance diagnostic ultrasound imaging techniques and to explore therapeutic applications, these medical microbubbles have been studied with the aid of high-speed photography. We filmed medical microb...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2133718
更新日期:2005-12-01 00:00:00
abstract::While simple, intravascular brachytherapy (IVB) presents a considerable potential for harm to the patient. The medical physicist maintains the responsibility to minimize the likelihood of operational problems or dosimetric errors. The principals for safe operation remain the same as with any radiotherapy treatment: to...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1524167
更新日期:2002-12-01 00:00:00
abstract:PURPOSE:To develop a hypothesis-generating framework for automatic extraction of dose-outcome relationships from an in-house, analytic oncology database. METHODS:Dose-volume histograms (DVH) and clinical outcomes have been routinely stored to the authors' database for 684 head and neck cancer patients treated from 200...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4922686
更新日期:2015-07-01 00:00:00
abstract:PURPOSE:The complex beam delivery techniques for patient treatment using a clinical linear accelerator (linac) may result in variations in the photon spectra, which can lead to dosimetric differences in patients that cannot be accounted for by current treatment planning systems (TPSs). Therefore, precise knowledge of t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13569
更新日期:2019-07-01 00:00:00
abstract:PURPOSE:Task Group 119 (TG-119) has been adopted for evaluating the adequacy of intensity-modulated radiation therapy (IMRT) commissioning and for establishing patient-specific IMRT quality assurance (QA) passing criteria in clinical practice. TG-119 establishes 95% confidence limits (CLs), which help clinics identify ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12759
更新日期:2018-03-01 00:00:00
abstract::The relationship between the pixel value and exit dose was investigated for a new commercially available amorphous silicon electronic portal imaging device. The pixel to dose mapping function was established to be linear for detector distances between 116.5 cm to 150 cm from the source, radiation field sizes from 5 x ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1508108
更新日期:2002-10-01 00:00:00
abstract::The attenuating properties of several types of lead (Pb)-based and non-Pb radiation shielding materials were studied and a correlation was made of radiation attenuation, materials properties, calculated spectra and ambient dose equivalent. Utilizing the well-characterized x-ray and gamma ray beams at the National Rese...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2426404
更新日期:2007-02-01 00:00:00
abstract:PURPOSE:To study if malfunction of a receiver can be detected robustly using the simple ACR SNR measurement approach on a 32-channel head coil. METHODS:Standard ACR T1W images (11slice) were acquired with a commercial 32 channel head coil on a 3T Philips Achieva MR scanner following the ACR recommended setup. Raw data...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736227
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:In this work, the fabrication, operation, and evaluation of a probe-format graphite calorimeter - herein referred to as Aerrow - as an absolute clinical dosimeter of high-energy photon beams while in the presence of a B = 1.5 T magnetic field is described. Comparable to a cylindrical ionization chamber (IC) in ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13968
更新日期:2020-03-01 00:00:00
abstract::The use of Kumakhov capillary optics will significantly enhance the performance of near-monochromatic, Compton backscattered x-ray programs. The Vanderbilt University Medical Free-Electron Laser Center is developing the capability to create these tunable x rays for medical imaging. The present transport has only refle...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597218
更新日期:1994-11-01 00:00:00
abstract:PURPOSE:Secondary particles produced in the collision of protons with beam modifiers are of concern in proton therapy. Nevertheless, secondary radiation can provide information on the dosimetric parameters through its dependency on the modulating accessories (range shifter and range modulating wheel). Relatively little...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4765049
更新日期:2012-12-01 00:00:00
abstract::We are evaluating the usefulness of stereomammography in improving breast cancer diagnosis. One area that we are investigating is whether the improved depth perception associated with stereomammography might be significantly enhanced with the use of a virtual 3D cursor. A study was performed to evaluate the accuracy o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.599008
更新日期:2000-06-01 00:00:00
abstract::An automated technique has been developed for the verification of treatment field size and shape in external beam radiation therapy. Portal images from film or digital on-line imaging system are analyzed, and basic parameters are derived to describe the field size and shape from the contour points on the field boundar...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597017
更新日期:1993-05-01 00:00:00