Verification of radiotherapy treatments: computerized analysis of the size and shape of radiation fields.

Abstract:

:An automated technique has been developed for the verification of treatment field size and shape in external beam radiation therapy. Portal images from film or digital on-line imaging system are analyzed, and basic parameters are derived to describe the field size and shape from the contour points on the field boundary. The initial set of parameters included length of the perimeter, area, aspect ratio, and orientation angle. The parameters found for the actual field in the portal image are compared against those calculated for the prescribed field and any discrepancies indicated to the operator. The accuracy of the field parameterization scheme has been tested on a number of on-line portal images with varying fields. The relative error did not exceed a few percent in perimeter and area or 2 degrees in the angle, which should be sufficiently low for the detection of major errors in field shaping.

journal_name

Med Phys

journal_title

Medical physics

authors

Leszczynski KW,Shalev S,Gluhchev G

doi

10.1118/1.597017

subject

Has Abstract

pub_date

1993-05-01 00:00:00

pages

687-94

issue

3

eissn

0094-2405

issn

2473-4209

journal_volume

20

pub_type

杂志文章
  • Microdosimetric study for secondary neutrons in phantom produced by a 290 MeV/nucleon carbon beam.

    abstract::Absorbed doses from main charged-particle beams and charged-particle fragments have been measured with high accuracy for particle therapy, but there are few reports for doses from neutron components produced as fragments. This study describes the measurements on neutron doses produced by carbon beams; microdosimetric ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2767933

    authors: Endo S,Tanaka K,Takada M,Onizuka Y,Miyahara N,Sato T,Ishikawa M,Maeda N,Hayabuchi N,Shizuma K,Hoshi M

    更新日期:2007-09-01 00:00:00

  • Resolution of pinhole collimators used with gamma cameras.

    abstract::The line spread function (LSF) of an imaging system incorporating a pinhole of 0.275 cm radius and a scintillation camera has been measured and its full width at half maximum (FWHM) compared to the values predicted by an expression based on the resolution index of Anger. In most cases, the actual resolution of the sys...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594755

    authors: Goulet P,Joy ML

    更新日期:1980-09-01 00:00:00

  • Characterization of scintillator-based detectors for few-ten-keV high-spatial-resolution x-ray imaging.

    abstract:PURPOSE:High-spatial-resolution x-ray imaging in the few-ten-keV range is becoming increasingly important in several applications, such as small-animal imaging and phase-contrast imaging. The detector properties critically influence the quality of such imaging. Here the authors present a quantitative comparison of scin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4948687

    authors: Larsson JC,Lundström U,Hertz HM

    更新日期:2016-06-01 00:00:00

  • Four-dimensional cone-beam computed tomography and digital tomosynthesis reconstructions using respiratory signals extracted from transcutaneously inserted metal markers for liver SBRT.

    abstract:PURPOSE:Respiration-induced intrafraction target motion is a concern in liver cancer radiotherapy, especially in stereotactic body radiotherapy (SBRT), and therefore, verification of its motion is necessary. An effective means to localize the liver cancer is to insert metal fiducial markers to or near the tumor with si...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3544369

    authors: Park JC,Park SH,Kim JH,Yoon SM,Kim SS,Kim JS,Liu Z,Watkins T,Song WY

    更新日期:2011-02-01 00:00:00

  • Focused RF hyperthermia using magnetic fluids.

    abstract::Heat therapies such as hyperthermia and thermoablation are very promising approaches in the treatment of cancer. Compared with available hyperthermia modalities, magnetic fluid hyperthermia (MFH) yields better results in uniform heating of the deeply situated tumors. In this approach, fluid consisting of superparamagn...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3106343

    authors: Tasci TO,Vargel I,Arat A,Guzel E,Korkusuz P,Atalar E

    更新日期:2009-05-01 00:00:00

  • 4D rotational x-ray imaging of wrist joint dynamic motion.

    abstract::Current methods for imaging joint motion are limited to either two-dimensional (2D) video fluoroscopy, or to animated motions from a series of static three-dimensional (3D) images. 3D movement patterns can be detected from biplane fluoroscopy images matched with computed tomography images. This involves several x-ray ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2000647

    authors: Carelsen B,Bakker NH,Strackee SD,Boon SN,Maas M,Sabczynski J,Grimbergen CA,Streekstra GJ

    更新日期:2005-09-01 00:00:00

  • Dual-film cassette technique for studying the effect of radiographic image quality on diagnostic accuracy.

    abstract::In order to investigate the relationship between diagnostic accuracy and radiographic image quality, we have developed a dual-film cassette which produces two radiographs simultaneously with a single exposure. One of these radiographs is of standard quality; the second is of lower quality because of degraded spatial r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595546

    authors: Higashida Y,Doi K,Lehr JL,MacMahon H

    更新日期:1984-09-01 00:00:00

  • Systematic feasibility analysis of performing elastography using reduced dose CT lung image pairs.

    abstract:PURPOSE:Elastography using computer tomography (CT) is a promising methodology that can provide patient-specific regional distributions of lung biomechanical properties. The purpose of this paper is to investigate the feasibility of performing elastography using simulated lower dose CT scans. METHODS:A cohort of eight...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14112

    authors: Hasse K,Hsieh SS,O'Connell D,Stiehl B,Min Y,Neylon J,Low DA,Santhanam AP

    更新日期:2020-08-01 00:00:00

  • Rotationally resliced 3D prostate TRUS segmentation using convex optimization with shape priors.

    abstract:PURPOSE:Efficient and accurate segmentations of 3D end-firing transrectal ultrasound (TRUS) images play an important role in planning of 3D TRUS guided prostate biopsy. However, poor image quality of the input 3D TRUS images, such as strong imaging artifacts and speckles, often makes it a challenging task to extract th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4906129

    authors: Qiu W,Yuan J,Ukwatta E,Fenster A

    更新日期:2015-02-01 00:00:00

  • An EGS4 Monte Carlo examination of the response of a PTW-diamond radiation detector in megavoltage electron beams.

    abstract::The EGS4 Monte Carlo code has been used to investigate the response of a PTW/diamond detector irradiated in both clinical and monoenergetic megavoltage electron beams ranging in energy from 5 to 20 MeV. The sensitive volume of the PTW/diamond detector simulated has a thickness of 0.4 mm and a diameter of 4.4 mm. Irrad...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598593

    authors: Mobit PN,Sandison GA

    更新日期:1999-05-01 00:00:00

  • Photon dose calculation incorporating explicit electron transport.

    abstract::Significant advances have been made in recent years to improve photon dose calculation. However, accurate prediction of dose perturbation effects near the interfaces of different media, where charged particle equilibrium is not established, remain unsolved. Furthermore, changes in atomic number, which affect the multi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597611

    authors: Yu CX,Mackie TR,Wong JW

    更新日期:1995-07-01 00:00:00

  • SU-E-I-99: An Ultra-High Resolution Small Field-Of-View Solid State X-Ray Imaging Detector Based on an Electron Multiplying CCD.

    abstract:PURPOSE:To demonstrate the ultra-high resolution capability of a small field-of-view (FOV) solid state x-ray imaging detector based on an EMCCD sensor. METHODS:A micro-solid state x-ray image intensifier (micro-SSXII) was developed to serve as an ultra-high resolution region-of-interest (ROI) imaging detector. It is b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734816

    authors: Singh V,Loughran B,Jain A,Sharma P,Bednarek D,Rudin S

    更新日期:2012-06-01 00:00:00

  • SU-E-T-269: The Evaluation of Copper as an Alternative for Cerrobend Electron Shielding.

    abstract:PURPOSE:To evaluate the replacement of Cerrobend by copper for electron beam cutouts. METHODS:The dosimetric comparisons for circular copper-and Cerrobend-cutouts with diameters (1.0, 2.0, 3.0, 5.0, 7.5, 10.0, and 12.5 cm) were made using electron beams with energies (6, 9, 12, 16, and 20 MeV) from 3 Varian accelerato...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735336

    authors: Chu A,Feng W,Ahmad M,Chen Z,Nath R

    更新日期:2012-06-01 00:00:00

  • Reconstruction of electron spectra using singular component decomposition.

    abstract::Reconstruction of electron spectra of medical accelerators from measured depth dose distributions is an attractive tool for commissioning of a Monte Carlo treatment planning system. However, the reconstruction method is an inverse radiation transport problem which is poorly conditioned, in the sense it may become unst...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1461840

    authors: Chvetsov AV,Sandison GA

    更新日期:2002-04-01 00:00:00

  • Second cancer incidence risk estimates using BEIR VII models for standard and complex external beam radiotherapy for early breast cancer.

    abstract:PURPOSE:To compare organ specific cancer incidence risks for standard and complex external beam radiotherapy (including cone beam CT verification) following breast conservation surgery for early breast cancer. METHOD:Doses from breast radiotherapy and kilovoltage cone beam CT (CBCT) exposures were obtained from thermo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4748332

    authors: Donovan EM,James H,Bonora M,Yarnold JR,Evans PM

    更新日期:2012-10-01 00:00:00

  • Radiofrequency transmit calibration: A multi-center evaluation of vendor-provided radiofrequency transmit mapping methods.

    abstract:PURPOSE:To determine the accuracy and test-retest repeatability of fast radiofrequency (RF) transmit measurement approaches used in Dynamic Contrast Enhanced Magnetic Resonance Imaging (DCE-MRI). Spatial variation in the transmitted RF field introduces bias and increased variance in quantitative DCE-MRI metrics includi...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1002/mp.13518

    authors: Bliesener Y,Zhong X,Guo Y,Boss M,Bosca R,Laue H,Chung C,Sung K,Nayak KS

    更新日期:2019-06-01 00:00:00

  • Development and validation of a measurement-based source model for kilovoltage cone-beam CT Monte Carlo dosimetry simulations.

    abstract:PURPOSE:The purpose of this study is to adapt an equivalent source model originally developed for conventional CT Monte Carlo dose quantification to the radiation oncology context and validate its application for evaluating concomitant dose incurred by a kilovoltage (kV) cone-beam CT (CBCT) system integrated into a lin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4823795

    authors: McMillan K,McNitt-Gray M,Ruan D

    更新日期:2013-11-01 00:00:00

  • Use of CEA TVS film for measuring high energy photon beam dose distributions.

    abstract::CEA TVS film is a therapy verification film that has been recently introduced in the North American market. This film features linear characteristic curves for photon energies from 137Cs to 18 MV as reported by Cheng and Das [Med. Phys. 23, 1225 (1996)]. In Saskatoon, TVS film was investigated for its application in t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598316

    authors: Cadman P

    更新日期:1998-08-01 00:00:00

  • Comparison of breast density measured on MR images acquired using fat-suppressed versus nonfat-suppressed sequences.

    abstract:PURPOSE:To investigate the difference of MR percent breast density measured from fat-suppressed versus nonfat-suppressed imaging sequences. METHODS:Breast magnetic resonance imaging (MRI) with and without fat suppression was acquired from 38 subjects. Breasts were divided into subgroups of different morphological patt...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3646756

    authors: Chang DH,Chen JH,Lin M,Bahri S,Yu HJ,Mehta RS,Nie K,Hsiang DJ,Nalcioglu O,Su MY

    更新日期:2011-11-01 00:00:00

  • Technical Note: Experimental verification of magnetic field-induced beam deflection and Bragg peak displacement for MR-integrated proton therapy.

    abstract:PURPOSE:Given its sensitivity to anatomical variations, proton therapy is expected to benefit greatly from integration with magnetic resonance imaging for online anatomy monitoring during irradiation. Such an integration raises several challenges, as both systems mutually interact. The proton beam will experience quasi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12961

    authors: Schellhammer SM,Gantz S,Lühr A,Oborn BM,Bussmann M,Hoffmann AL

    更新日期:2018-07-01 00:00:00

  • Dose distributions of a proton beam for eye tumor therapy: hybrid pencil-beam ray-tracing calculations.

    abstract::For the case of eye tumor therapy with protons, improvements are introduced compared to the standard dose calculation which implies straight-line optics and the constant-density assumption for the eye and its surrounding. The progress consists of (i) taking account of the lateral scattering of the protons in tissue by...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2168067

    authors: Rethfeldt C,Fuchs H,Gardey KU

    更新日期:2006-03-01 00:00:00

  • Long term variation in beam symmetry as a function of gantry angle for a computer-controlled linear accelerator.

    abstract::Testing computer-controlled linear accelerators for patient safety and proper patient dose delivery requires that certain beam characteristics be monitored over an extended period of time. Computer-controlled conformal radiation therapy using asymmetric collimator jaw settings necessitates stable symmetric treatment b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596363

    authors: Loyd MD,Lane RG,Laxton J,Chow CH,Rosen II

    更新日期:1989-07-01 00:00:00

  • Sci-Thur AM: Planning - 10: Improved dosimetric accuracy for patient specific quality assurance using a dual-detector measurement method for cyberknife output factors.

    abstract::The measurement of output factors for small fields is challenging and can lead to large dose errors in patient treatments if corrections for detector size and scatter from high-Z material are not applied. Due to its high spatial resolution and near tissue equivalence, GAFCHROMIC® film potentially provides a correction...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740095

    authors: Vandervoort E,La Russa D,Ploquin N,Kadir IAE,Szanto J

    更新日期:2012-07-01 00:00:00

  • Accuracy of Monte Carlo simulations compared to in-vivo MDCT dosimetry.

    abstract:PURPOSE:The purpose of this study was to assess the accuracy of a Monte Carlo simulation-based method for estimating radiation dose from multidetector computed tomography (MDCT) by comparing simulated doses in ten patients to in-vivo dose measurements. METHODS:MD Anderson Cancer Center Institutional Review Board appro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4906178

    authors: Bostani M,Mueller JW,McMillan K,Cody DD,Cagnon CH,DeMarco JJ,McNitt-Gray MF

    更新日期:2015-02-01 00:00:00

  • Introduction of a novel dose saving acquisition mode for the PortalVision aS500 EPID to facilitate on-line patient setup verification.

    abstract::In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1668391

    authors: Vetterli D,Riem H,Aebersold DM,Greiner RH,Manser P,Cossmann P,Kemmerling L,Born EJ,Mini R

    更新日期:2004-04-01 00:00:00

  • Computer-aided detection of breast cancers using Haar-like features in automated 3D breast ultrasound.

    abstract:PURPOSE:Automated 3D breast ultrasound (ABUS) has gained interest in breast imaging. Especially for screening women with dense breasts, ABUS appears to be beneficial. However, since the amount of data generated is large, the risk of oversight errors is substantial. Computer aided detection (CADe) may be used as a secon...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4914162

    authors: Tan T,Mordang JJ,van Zelst J,Grivegnée A,Gubern-Mérida A,Melendez J,Mann RM,Zhang W,Platel B,Karssemeijer N

    更新日期:2015-04-01 00:00:00

  • Electron beam water calorimetry measurements to obtain beam quality conversion factors.

    abstract:PURPOSE:To provide results of water calorimetry and ion chamber measurements in high-energy electron beams carried out at the National Research Council Canada (NRC). There are three main aspects to this work: (a) investigation of the behavior of ionization chambers in electron beams of different energies with focus on ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12463

    authors: Muir BR,Cojocaru CD,McEwen MR,Ross CK

    更新日期:2017-10-01 00:00:00

  • Semiautomated registration of pre- and intraoperative CT for image-guided percutaneous liver tumor ablation interventions.

    abstract:PURPOSE:In CT-guided liver tumor ablation interventions, registration of a preoperative contrast-enhanced CT image to the intraoperative CT image is hypothesized to improve guidance. This is a highly challenging registration task due to differences in patient poses and large deformations, and therefore high registratio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12332

    authors: Gunay G,Luu MH,Moelker A,van Walsum T,Klein S

    更新日期:2017-07-01 00:00:00

  • Optical spectroscopy of the breast in premenopausal women reveals tissue variation with changes in age and parity.

    abstract:PURPOSE:Variations during breast tissue development can influence later breast cancer risk. In particular, prolonged nulliparity increases risk. The authors used optical spectroscopy to compare breast tissue in 115 nulliparous women aged 31-40 (group 2) to 140 nulliparous women aged 18-21 (group 1), and also to 36 paro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3276737

    authors: Knight JA,Blackmore KM,Wong J,Tharmalingam S,Lilge L

    更新日期:2010-02-01 00:00:00

  • A methodology to determine margins by EPID measurements of patient setup variation and motion as applied to immobilization devices.

    abstract::Assessment of clinic and site specific margins are essential for the effective use of three-dimensional and intensity modulated radiation therapy. An electronic portal imaging device (EPID) based methodology is introduced which allows individual and population based CTV-to-PTV margins to be determined and compared wit...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1800712

    authors: Prisciandaro JI,Frechette CM,Herman MG,Brown PD,Garces YI,Foote RL

    更新日期:2004-11-01 00:00:00