Abstract:
:An automated technique has been developed for the verification of treatment field size and shape in external beam radiation therapy. Portal images from film or digital on-line imaging system are analyzed, and basic parameters are derived to describe the field size and shape from the contour points on the field boundary. The initial set of parameters included length of the perimeter, area, aspect ratio, and orientation angle. The parameters found for the actual field in the portal image are compared against those calculated for the prescribed field and any discrepancies indicated to the operator. The accuracy of the field parameterization scheme has been tested on a number of on-line portal images with varying fields. The relative error did not exceed a few percent in perimeter and area or 2 degrees in the angle, which should be sufficiently low for the detection of major errors in field shaping.
journal_name
Med Physjournal_title
Medical physicsauthors
Leszczynski KW,Shalev S,Gluhchev Gdoi
10.1118/1.597017subject
Has Abstractpub_date
1993-05-01 00:00:00pages
687-94issue
3eissn
0094-2405issn
2473-4209journal_volume
20pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Absorbed doses from main charged-particle beams and charged-particle fragments have been measured with high accuracy for particle therapy, but there are few reports for doses from neutron components produced as fragments. This study describes the measurements on neutron doses produced by carbon beams; microdosimetric ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2767933
更新日期:2007-09-01 00:00:00
abstract::The line spread function (LSF) of an imaging system incorporating a pinhole of 0.275 cm radius and a scintillation camera has been measured and its full width at half maximum (FWHM) compared to the values predicted by an expression based on the resolution index of Anger. In most cases, the actual resolution of the sys...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594755
更新日期:1980-09-01 00:00:00
abstract:PURPOSE:High-spatial-resolution x-ray imaging in the few-ten-keV range is becoming increasingly important in several applications, such as small-animal imaging and phase-contrast imaging. The detector properties critically influence the quality of such imaging. Here the authors present a quantitative comparison of scin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4948687
更新日期:2016-06-01 00:00:00
abstract:PURPOSE:Respiration-induced intrafraction target motion is a concern in liver cancer radiotherapy, especially in stereotactic body radiotherapy (SBRT), and therefore, verification of its motion is necessary. An effective means to localize the liver cancer is to insert metal fiducial markers to or near the tumor with si...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3544369
更新日期:2011-02-01 00:00:00
abstract::Heat therapies such as hyperthermia and thermoablation are very promising approaches in the treatment of cancer. Compared with available hyperthermia modalities, magnetic fluid hyperthermia (MFH) yields better results in uniform heating of the deeply situated tumors. In this approach, fluid consisting of superparamagn...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3106343
更新日期:2009-05-01 00:00:00
abstract::Current methods for imaging joint motion are limited to either two-dimensional (2D) video fluoroscopy, or to animated motions from a series of static three-dimensional (3D) images. 3D movement patterns can be detected from biplane fluoroscopy images matched with computed tomography images. This involves several x-ray ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2000647
更新日期:2005-09-01 00:00:00
abstract::In order to investigate the relationship between diagnostic accuracy and radiographic image quality, we have developed a dual-film cassette which produces two radiographs simultaneously with a single exposure. One of these radiographs is of standard quality; the second is of lower quality because of degraded spatial r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595546
更新日期:1984-09-01 00:00:00
abstract:PURPOSE:Elastography using computer tomography (CT) is a promising methodology that can provide patient-specific regional distributions of lung biomechanical properties. The purpose of this paper is to investigate the feasibility of performing elastography using simulated lower dose CT scans. METHODS:A cohort of eight...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14112
更新日期:2020-08-01 00:00:00
abstract:PURPOSE:Efficient and accurate segmentations of 3D end-firing transrectal ultrasound (TRUS) images play an important role in planning of 3D TRUS guided prostate biopsy. However, poor image quality of the input 3D TRUS images, such as strong imaging artifacts and speckles, often makes it a challenging task to extract th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4906129
更新日期:2015-02-01 00:00:00
abstract::The EGS4 Monte Carlo code has been used to investigate the response of a PTW/diamond detector irradiated in both clinical and monoenergetic megavoltage electron beams ranging in energy from 5 to 20 MeV. The sensitive volume of the PTW/diamond detector simulated has a thickness of 0.4 mm and a diameter of 4.4 mm. Irrad...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598593
更新日期:1999-05-01 00:00:00
abstract::Significant advances have been made in recent years to improve photon dose calculation. However, accurate prediction of dose perturbation effects near the interfaces of different media, where charged particle equilibrium is not established, remain unsolved. Furthermore, changes in atomic number, which affect the multi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597611
更新日期:1995-07-01 00:00:00
abstract:PURPOSE:To demonstrate the ultra-high resolution capability of a small field-of-view (FOV) solid state x-ray imaging detector based on an EMCCD sensor. METHODS:A micro-solid state x-ray image intensifier (micro-SSXII) was developed to serve as an ultra-high resolution region-of-interest (ROI) imaging detector. It is b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734816
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To evaluate the replacement of Cerrobend by copper for electron beam cutouts. METHODS:The dosimetric comparisons for circular copper-and Cerrobend-cutouts with diameters (1.0, 2.0, 3.0, 5.0, 7.5, 10.0, and 12.5 cm) were made using electron beams with energies (6, 9, 12, 16, and 20 MeV) from 3 Varian accelerato...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735336
更新日期:2012-06-01 00:00:00
abstract::Reconstruction of electron spectra of medical accelerators from measured depth dose distributions is an attractive tool for commissioning of a Monte Carlo treatment planning system. However, the reconstruction method is an inverse radiation transport problem which is poorly conditioned, in the sense it may become unst...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1461840
更新日期:2002-04-01 00:00:00
abstract:PURPOSE:To compare organ specific cancer incidence risks for standard and complex external beam radiotherapy (including cone beam CT verification) following breast conservation surgery for early breast cancer. METHOD:Doses from breast radiotherapy and kilovoltage cone beam CT (CBCT) exposures were obtained from thermo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4748332
更新日期:2012-10-01 00:00:00
abstract:PURPOSE:To determine the accuracy and test-retest repeatability of fast radiofrequency (RF) transmit measurement approaches used in Dynamic Contrast Enhanced Magnetic Resonance Imaging (DCE-MRI). Spatial variation in the transmitted RF field introduces bias and increased variance in quantitative DCE-MRI metrics includi...
journal_title:Medical physics
pub_type: 杂志文章,多中心研究
doi:10.1002/mp.13518
更新日期:2019-06-01 00:00:00
abstract:PURPOSE:The purpose of this study is to adapt an equivalent source model originally developed for conventional CT Monte Carlo dose quantification to the radiation oncology context and validate its application for evaluating concomitant dose incurred by a kilovoltage (kV) cone-beam CT (CBCT) system integrated into a lin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4823795
更新日期:2013-11-01 00:00:00
abstract::CEA TVS film is a therapy verification film that has been recently introduced in the North American market. This film features linear characteristic curves for photon energies from 137Cs to 18 MV as reported by Cheng and Das [Med. Phys. 23, 1225 (1996)]. In Saskatoon, TVS film was investigated for its application in t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598316
更新日期:1998-08-01 00:00:00
abstract:PURPOSE:To investigate the difference of MR percent breast density measured from fat-suppressed versus nonfat-suppressed imaging sequences. METHODS:Breast magnetic resonance imaging (MRI) with and without fat suppression was acquired from 38 subjects. Breasts were divided into subgroups of different morphological patt...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3646756
更新日期:2011-11-01 00:00:00
abstract:PURPOSE:Given its sensitivity to anatomical variations, proton therapy is expected to benefit greatly from integration with magnetic resonance imaging for online anatomy monitoring during irradiation. Such an integration raises several challenges, as both systems mutually interact. The proton beam will experience quasi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12961
更新日期:2018-07-01 00:00:00
abstract::For the case of eye tumor therapy with protons, improvements are introduced compared to the standard dose calculation which implies straight-line optics and the constant-density assumption for the eye and its surrounding. The progress consists of (i) taking account of the lateral scattering of the protons in tissue by...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2168067
更新日期:2006-03-01 00:00:00
abstract::Testing computer-controlled linear accelerators for patient safety and proper patient dose delivery requires that certain beam characteristics be monitored over an extended period of time. Computer-controlled conformal radiation therapy using asymmetric collimator jaw settings necessitates stable symmetric treatment b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596363
更新日期:1989-07-01 00:00:00
abstract::The measurement of output factors for small fields is challenging and can lead to large dose errors in patient treatments if corrections for detector size and scatter from high-Z material are not applied. Due to its high spatial resolution and near tissue equivalence, GAFCHROMIC® film potentially provides a correction...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740095
更新日期:2012-07-01 00:00:00
abstract:PURPOSE:The purpose of this study was to assess the accuracy of a Monte Carlo simulation-based method for estimating radiation dose from multidetector computed tomography (MDCT) by comparing simulated doses in ten patients to in-vivo dose measurements. METHODS:MD Anderson Cancer Center Institutional Review Board appro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4906178
更新日期:2015-02-01 00:00:00
abstract::In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1668391
更新日期:2004-04-01 00:00:00
abstract:PURPOSE:Automated 3D breast ultrasound (ABUS) has gained interest in breast imaging. Especially for screening women with dense breasts, ABUS appears to be beneficial. However, since the amount of data generated is large, the risk of oversight errors is substantial. Computer aided detection (CADe) may be used as a secon...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4914162
更新日期:2015-04-01 00:00:00
abstract:PURPOSE:To provide results of water calorimetry and ion chamber measurements in high-energy electron beams carried out at the National Research Council Canada (NRC). There are three main aspects to this work: (a) investigation of the behavior of ionization chambers in electron beams of different energies with focus on ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12463
更新日期:2017-10-01 00:00:00
abstract:PURPOSE:In CT-guided liver tumor ablation interventions, registration of a preoperative contrast-enhanced CT image to the intraoperative CT image is hypothesized to improve guidance. This is a highly challenging registration task due to differences in patient poses and large deformations, and therefore high registratio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12332
更新日期:2017-07-01 00:00:00
abstract:PURPOSE:Variations during breast tissue development can influence later breast cancer risk. In particular, prolonged nulliparity increases risk. The authors used optical spectroscopy to compare breast tissue in 115 nulliparous women aged 31-40 (group 2) to 140 nulliparous women aged 18-21 (group 1), and also to 36 paro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3276737
更新日期:2010-02-01 00:00:00
abstract::Assessment of clinic and site specific margins are essential for the effective use of three-dimensional and intensity modulated radiation therapy. An electronic portal imaging device (EPID) based methodology is introduced which allows individual and population based CTV-to-PTV margins to be determined and compared wit...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1118/1.1800712
更新日期:2004-11-01 00:00:00