SU-E-I-99: An Ultra-High Resolution Small Field-Of-View Solid State X-Ray Imaging Detector Based on an Electron Multiplying CCD.

Abstract:

PURPOSE:To demonstrate the ultra-high resolution capability of a small field-of-view (FOV) solid state x-ray imaging detector based on an EMCCD sensor. METHODS:A micro-solid state x-ray image intensifier (micro-SSXII) was developed to serve as an ultra-high resolution region-of-interest (ROI) imaging detector. It is based on an 8 micron, 1004 by 1002 pixel electron multiplying CCD (EMCCD) optically coupled to a 100 micron thick CsI(Tl) phosphor through a fiber optic window resulting in a FOV of 8 mm. The modulation transfer function (MTF) of the micro-SSXII was measured by the slanted edge method. A cast of a rat kidney (made by mixing resin and iodine for contrast) and a mammography line pair test object were imaged at 50 kVp to demonstrate the detector's ultra-high resolution capability visually. RESULTS:The MTF was determined and was 5% at 20 cycles/mm. This is consistent with the clear visualization of the maximum 20 lp/mm group in the image of the mammography test object. Also, iodine bubbles with diameters as small as 25 microns, which are formed by the non-uniform mixing of the iodine in the resin cast, can be clearly identified in the rat kidney vessels. CONCLUSIONS:The ultra-high resolution capability (>20 lp/mm) but small FOV (8 mm) of the micro-SSXII in combination with a low-energy x-ray source may have application for investigations of vascular specimen details and other fine structures where optical or other surface imagers would be unsuited for evaluating features below the surface. Contact radiography with this imager combined with a large higher-load focal spot x-ray tube may be a promising substitute for magnification radiography which is limited by the use of specialized low output microfocus x-ray tubes and geometric un-sharpness for large magnifications. Supported in part by: NIH Grants R01-EB008425, R01-EB002873 and an equipment grant from Toshiba Medical Systems Corp.

journal_name

Med Phys

journal_title

Medical physics

authors

Singh V,Loughran B,Jain A,Sharma P,Bednarek D,Rudin S

doi

10.1118/1.4734816

subject

Has Abstract

pub_date

2012-06-01 00:00:00

pages

3647-3648

issue

6Part5

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • A novel curvilinear approach for prostate seed implantation.

    abstract:PURPOSE:A new technique called "curvilinear approach" for prostate seed implantation has been proposed. The purpose of this study is to evaluate the dosimetric benefit of curvilinear distribution of seeds for low-dose-rate (LDR) prostate brachytherapy. METHODS:Twenty LDR prostate brachytherapy cases planned intraopera...

    journal_title:Medical physics

    pub_type: 杂志文章,随机对照试验

    doi:10.1118/1.3694110

    authors: Podder TK,Dicker AP,Hutapea P,Darvish K,Yu Y

    更新日期:2012-04-01 00:00:00

  • Loss of field flatness in AECL teletherapy units form misadjustment of the collimator.

    abstract::Atomic Energy of Canada Limited 60Co teletherapy units have adjustable collimator hinges to adapt to source diameters from 0.75 to 2.50 cm. Adjustment of the collimator hinge to the manfacturer's settings can cause a loss of radiation field flatness as high as 20% for large fields. The recommended settings appear to c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594170

    authors: Heintz PH

    更新日期:1975-03-01 00:00:00

  • Technical Note: Comparison of megavoltage, dual-energy, and single-energy CT-based μ-maps for a four-channel breast coil in PET/MRI.

    abstract:PURPOSE:The purpose of this study was to describe and evaluate methods for calculating a megavoltage computed tomography (MVCT)-derived MR hardware attenuation map (μ-map) and dual-energy CT (DECT) for 511 keV photons. METHODS:Phantom measurements were acquired on a whole-body hybrid PET/MRI system, using a four-chann...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12407

    authors: Patrick JC,Terry Thompson R,So A,Butler J,Faul D,Stodilka RZ,Yartsev S,Prato FS,Gaede S

    更新日期:2017-09-01 00:00:00

  • Reduction of motion blurring artifacts using respiratory gated CT in sinogram space: a quantitative evaluation.

    abstract::Techniques have been developed for reducing motion blurring artifacts by using respiratory gated computed tomography (CT) in sinogram space and quantitatively evaluating the artifact reduction. A synthetic sinogram was built from multiple scans intercepting a respiratory gating window. A gated CT image was then recons...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2074187

    authors: Lu W,Parikh PJ,Hubenschmidt JP,Politte DG,Whiting BR,Bradley JD,Mutic S,Low DA

    更新日期:2005-11-01 00:00:00

  • Electron dosimetry based on the absorbed dose to water concept: a comparison of the AAPM TG-51 and DIN 6800-2 protocols.

    abstract::The dosimetry protocols DIN 6800-2 and AAPM TG-51, both based on the absorbed dose to water concept, are compared in their theoretical background and in their application to electron dosimetry. The agreement and disagreement in correction factors and energy parameters used in both protocols will be shown and discussed...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1414008

    authors: Dohm OS,Christ G,Nüsslin F,Schüle E,Bruggmoser G

    更新日期:2001-11-01 00:00:00

  • Unexpectedly large dose rate dependent output from a linear accelerator.

    abstract::During our routine calibration of a Varian Clinac-20 linear accelerator, the absorbed dose for a fixed monitor unit (mu) was found to decrease with increasing dose rate. Between dose rates of 100 and 500 mu/min, there was up to 20% difference in absorbed dose for a 20-MeV electron beam. The cause of this problem was a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596192

    authors: Cheng PC,Kubo H

    更新日期:1988-09-01 00:00:00

  • Modification and benchmarking of MCNP for low-energy tungsten spectra.

    abstract::The MCNP Monte Carlo radiation transport code was modified for diagnostic medical physics applications. In particular, the modified code was thoroughly benchmarked for the production of polychromatic tungsten x-ray spectra in the 30-150 kV range. Validating the modified code for coupled electron-photon transport with ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1288397

    authors: Mercier JR,Kopp DT,McDavid WD,Dove SB,Lancaster JL,Tucker DM

    更新日期:2000-12-01 00:00:00

  • Cavity contour segmentation in chest radiographs using supervised learning and dynamic programming.

    abstract:PURPOSE:Efficacy of tuberculosis (TB) treatment is often monitored using chest radiography. Monitoring size of cavities in pulmonary tuberculosis is important as the size predicts severity of the disease and its persistence under therapy predicts relapse. The authors present a method for automatic cavity segmentation i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4881096

    authors: Maduskar P,Hogeweg L,de Jong PA,Peters-Bax L,Dawson R,Ayles H,Sánchez CI,van Ginneken B

    更新日期:2014-07-01 00:00:00

  • Robust calculation of effective atomic numbers: the Auto-Z(eff) software.

    abstract:PURPOSE:The most appropriate method of evaluating the effective atomic number necessitates consideration of energy-dependent behavior. Previously, this required quite laborious calculation, which is why many scientists revert to over-simplistic power-law methods. The purpose of this work is to develop user-friendly sof...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3689810

    authors: Taylor ML,Smith RL,Dossing F,Franich RD

    更新日期:2012-04-01 00:00:00

  • Robotic intrafractional US guidance for liver SABR: System design, beam avoidance, and clinical imaging.

    abstract:PURPOSE:To present a system for robotic 4D ultrasound (US) imaging concurrent with radiotherapy beam delivery and estimate the proportion of liver stereotactic ablative body radiotherapy (SABR) cases in which robotic US image guidance can be deployed without interfering with clinically used VMAT beam configurations. M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4964454

    authors: Schlosser J,Gong RH,Bruder R,Schweikard A,Jang S,Henrie J,Kamaya A,Koong A,Chang DT,Hristov D

    更新日期:2016-11-01 00:00:00

  • A 3D ultrasound scanning system for image guided liver interventions.

    abstract:PURPOSE:Two-dimensional ultrasound (2D US) imaging is commonly used for diagnostic and intraoperative guidance of interventional liver procedures; however, 2D US lacks volumetric information that may benefit interventional procedures. Over the past decade, three-dimensional ultrasound (3D US) has been developed to prov...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4824326

    authors: Neshat H,Cool DW,Barker K,Gardi L,Kakani N,Fenster A

    更新日期:2013-11-01 00:00:00

  • Low-complexity atlas-based prostate segmentation by combining global, regional, and local metrics.

    abstract:PURPOSE:To improve the efficiency of atlas-based segmentation without compromising accuracy, and to demonstrate the validity of the proposed method on MRI-based prostate segmentation application. METHODS:Accurate and efficient automatic structure segmentation is an important task in medical image processing. Atlas-bas...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4867855

    authors: Xie Q,Ruan D

    更新日期:2014-04-01 00:00:00

  • SU-E-I-94: External Beam Radiation Cherenkov Emission in Tissue Used for Tissue Oxygen Sensing.

    abstract:PURPOSE:To show that Cherenkov emission is generated by external radiotherapy beam in tissue, and could serve as optical source to excite an oxygen sensitive phosphor, Oxyphor G4, within tissue. The intensity and lifetime of the phosphorescence was measured with a time-gated system and reveals the oxygenation levels in...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734811

    authors: Zhang R,Kanick S,Vinogradov S,Esipova T,Pogue B

    更新日期:2012-06-01 00:00:00

  • Neutron and gamma spectroscopy for clinical dosimetry.

    abstract::Neutron and photon energy spectra were measured in different depths and lateral positions in tissue-equivalent phantoms exposed to a therapeutical 14.1 MeV neutron beam. Intensity weighted mass energy absorption coefficients were derived for application in ionization chamber dosimetry in mixed neutron-gamma fields. Th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594744

    authors: Schmidt R,Magiera E,Scobel W

    更新日期:1980-09-01 00:00:00

  • Dosimetry for radiocolloid therapy of cystic craniopharyngiomas.

    abstract::The dosimetry for radiocolloid therapy of cystic craniopharyngiomas is investigated. Analytical calculations based on the Loevinger and the Berger formulas for electrons and photons, respectively, are compared with Monte Carlo simulations. The role of the material of which the colloid introduced inside the craniophary...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1599653

    authors: Rojas EL,Al-Dweri FM,Lallena AM,Bodineau C,Galán P

    更新日期:2003-09-01 00:00:00

  • Sampling methods for a matrix ionization chamber system.

    abstract::To achieve increased image acquisition speed or better image quality, several read-out methods for a matrix ionization chamber system have been investigated. In this device, which is applied for portal imaging in radiation therapy, 256 x 256 small liquid-filled ionization chambers are scanned by switching the polarizi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596829

    authors: van Herk M,Bijhold J,Hoogervorst B,Meertens H

    更新日期:1992-03-01 00:00:00

  • Material elemental decomposition in dual and multi-energy CT via a sparsity-dictionary approach for proton stopping power ratio calculation.

    abstract:PURPOSE:Accurate calculation of proton stopping power ratio (SPR) relative to water is crucial to proton therapy treatment planning, since SPR affects prediction of beam range. Current standard practice derives SPR using a single CT scan. Recent studies showed that dual-energy CT (DECT) offers advantages to accurately ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12796

    authors: Shen C,Li B,Chen L,Yang M,Lou Y,Jia X

    更新日期:2018-04-01 00:00:00

  • Performance characteristics of A 150 plastic-equivalent gases in A 150 plastic proportional counters for 14.8-MeV neutrons.

    abstract::Two recently developed A 150 plastic-equivalent gas mixtures have been tested for suitability in proportional counter applications. Methane- and propane-based "tissue-equivalent" gases were also included for comparison purposes. Event-size weighted dose distributions were measured in a 14.8-MeV neutron beam. Resolutio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595536

    authors: DeLuca PM Jr,Schell MC,Pearson DW,Higgins PD,Attix FH

    更新日期:1984-07-01 00:00:00

  • Technical Note: Comparison of peripheral patient dose from MR-guided 60 Co therapy and 6 MV linear accelerator IGRT.

    abstract:PURPOSE:The use of X-ray imaging in radiation therapy can give a substantial dose to the patient. A Cobalt machine combined with an magnetic resonance imaging (MRI) was recently introduced to clinical work. One positive aspect of using non-ionizing imaging devices is the reduction of the patient exposure. The purpose o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12293

    authors: Hauri P,Hälg RA,Schneider U

    更新日期:2017-07-01 00:00:00

  • A feasible method for clinical delivery verification and dose reconstruction in tomotherapy.

    abstract::Delivery verification is the process in which the energy fluence delivered during a treatment is verified. This verified energy fluence can be used in conjunction with an image in the treatment position to reconstruct the full three-dimensional dose deposited. A method for delivery verification that utilizes a measure...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1352579

    authors: Kapatoes JM,Olivera GH,Ruchala KJ,Smilowitz JB,Reckwerdt PJ,Mackie TR

    更新日期:2001-04-01 00:00:00

  • SU-E-J-186: CT Textures Can be Predictive for Tumor Shrinkage.

    abstract:PURPOSE:To determine if NSCLC GTV CT textures can be predictive for tumor shrinkage after proton therapy with concurrent chemotherapy. METHODS:Simulation and weekly 4DCTs were obtained from 25 patients with locally advanced NSCLC treated by proton therapy at a 74 Gy dose level with concurrent chemotherapy. In-house de...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735027

    authors: Hunter L,Chen Y,Zhang L,Liao Z,Dong L,Court L

    更新日期:2012-06-01 00:00:00

  • SU-E-T-145: MRI Gel Dosimetry Applied to Dose Profile Determination for 50kV X-Ray Tube.

    abstract:PURPOSE:The aim of this study was to use MRI gel dosimetry to determine the dose profile of 50kV MAGNUM® X-ray tube, MOXTEK Inc., in order to calibrate small solid dosimeters of alanine, tooth enamel and LiF-TLDs, commonly used in clinical quality assurance and datation dosimetry. METHODS:MAGIC-f polymer gel was kept ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735203

    authors: Schwarcke M,Marques T,Nicolucci P,Filho OB

    更新日期:2012-06-01 00:00:00

  • Influence of gold nanoparticles embedded in water on nanodosimetry for keV photon irradiation.

    abstract:PURPOSE:For the past two decades, high-Z nanoparticles have been of high interest to improve the therapeutic outcomes of radiation therapy, especially for low-energy X-rays. Monte Carlo (MC) simulations have been used to evaluate the boost of dose deposition induced by Auger electrons near the nanoparticle surface, by ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14576

    authors: Poignant F,Monini C,Testa É,Beuve M

    更新日期:2020-11-04 00:00:00

  • Radiofrequency transmit calibration: A multi-center evaluation of vendor-provided radiofrequency transmit mapping methods.

    abstract:PURPOSE:To determine the accuracy and test-retest repeatability of fast radiofrequency (RF) transmit measurement approaches used in Dynamic Contrast Enhanced Magnetic Resonance Imaging (DCE-MRI). Spatial variation in the transmitted RF field introduces bias and increased variance in quantitative DCE-MRI metrics includi...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1002/mp.13518

    authors: Bliesener Y,Zhong X,Guo Y,Boss M,Bosca R,Laue H,Chung C,Sung K,Nayak KS

    更新日期:2019-06-01 00:00:00

  • Automatic treatment planning based on three-dimensional dose distribution predicted from deep learning technique.

    abstract:PURPOSE:To develop an automated treatment planning strategy for external beam intensity-modulated radiation therapy (IMRT), including a deep learning-based three-dimensional (3D) dose prediction and a dose distribution-based plan generation algorithm. METHODS AND MATERIALS:A residual neural network-based deep learning...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13271

    authors: Fan J,Wang J,Chen Z,Hu C,Zhang Z,Hu W

    更新日期:2019-01-01 00:00:00

  • Patient motion effects on the quantification of regional myocardial blood flow with dynamic PET imaging.

    abstract:PURPOSE:Patient motion is a common problem during dynamic positron emission tomography (PET) scans for quantification of myocardial blood flow (MBF). The purpose of this study was to quantify the prevalence of body motion in a clinical setting and evaluate with realistic phantoms the effects of motion on blood flow qua...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4943565

    authors: Hunter CR,Klein R,Beanlands RS,deKemp RA

    更新日期:2016-04-01 00:00:00

  • Evaluation of edge effect due to phase contrast imaging for mammography.

    abstract::It is well-known that the edge effect produced by phase contrast imaging results in the edge enhancement of x-ray images and thereby sharpens those images. It has recently been reported that phase contrast imaging using practical x-ray tubes with small focal spots has improved image sharpness as observed in the phase ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1992087

    authors: Matsuo S,Katafuchi T,Tohyama K,Morishita J,Yamada K,Fujita H

    更新日期:2005-08-01 00:00:00

  • MO-F-213AB-01: Improving Dose Uniformity in Patch-Field Proton Therapy Using Beam Current Modulation.

    abstract:PURPOSE:To improve the dose homogeneity in patch-field proton therapy using beam current modulation. METHODS:MCNPX simulations were performed for various configurations of the Mevion S250 beamline. Spread-out Bragg peak (SOBP) dose distributions were calculated, and lateral and distal dose profiles were extracted for ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735806

    authors: Hill P,Klein E,Bloch C

    更新日期:2012-06-01 00:00:00

  • Intercomparison of methods for image quality characterization. I. Modulation transfer function.

    abstract::The modulation transfer function (MTF) and the noise power spectrum (NPS) are widely recognized as the most relevant metrics of resolution and noise performance in radiographic imaging. These quantities have commonly been measured using various techniques, the specifics of which can have a bearing on the accuracy of t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2188816

    authors: Samei E,Ranger NT,Dobbins JT 3rd,Chen Y

    更新日期:2006-05-01 00:00:00

  • Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain.

    abstract:PURPOSE:The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. METHODS:The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4918321

    authors: Jung JH,Choi Y,Jung J,Kim S,Lim HK,Im KC,Oh CH,Park HW,Kim KM,Kim JG

    更新日期:2015-05-01 00:00:00