Abstract:
PURPOSE:The most appropriate method of evaluating the effective atomic number necessitates consideration of energy-dependent behavior. Previously, this required quite laborious calculation, which is why many scientists revert to over-simplistic power-law methods. The purpose of this work is to develop user-friendly software for the robust, energy-dependent computation of effective atomic numbers relevant within the context of medical physics, superseding the commonly employed simplistic power law approaches. METHOD:Visual Basic was used to develop a GUI allowing the straightforward calculation of effective atomic numbers. Photon interaction cross section matrices are constructed for energies spanning 10 keV to 10 GeV and elements Z = 1-100. Coefficients for composite media are constructed via linear additivity of the fractional constituents and contrasted against the precalculated matrices at each energy, thereby associating an effective atomic number through interpolation of adjacent cross section data. Uncertainties are of the order of 1-2%. RESULTS:Auto-Z(eff) allows rapid (∼0.6 s) calculation of effective atomic numbers for a range of predefined or user-specified media, allowing estimation of radiological properties and comparison of different media (for instance assessment of water equivalence). The accuracy of Auto-Z(eff) has been validated against numerous published theoretical and experimental predictions, demonstrating good agreement. The results also show that commonly employed power-law approaches are inaccurate, even in their intended regime of applicability (i.e., photoelectric regime). Furthermore, comparing the effective atomic numbers of composite materials using power-law approaches even in a relative fashion is shown to be inappropriate. CONCLUSION:Auto-Z(eff) facilitates easy computation of effective atomic numbers as a function of energy, as well as average and spectral-weighted means. The results are significantly more accurate than normal power-law predictions. The software is freely available to interested readers, who are encouraged to contact the authors.
journal_name
Med Physjournal_title
Medical physicsauthors
Taylor ML,Smith RL,Dossing F,Franich RDdoi
10.1118/1.3689810subject
Has Abstractpub_date
2012-04-01 00:00:00pages
1769-78issue
4eissn
0094-2405issn
2473-4209journal_volume
39pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::A method for the in vivo determination of the isocenter dose, Diso, and mid-plane dose, Dm, using the transmitted signal St measured by 25 central pixels of an aSi-based EPID is here reported. The method has been applied to check the conformal radiotherapy of pelvic tumors and supplies accurate in vivo dosimetry avoid...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2360014
更新日期:2006-11-01 00:00:00
abstract::The gamma index is a tool that compares a dose distribution with a reference distribution by combining dose-difference and distance-to-agreement criteria. It has been widely used for ten years despite its high computational cost. This cost is due to both a search process for each reference point and the necessity to r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3070546
更新日期:2009-03-01 00:00:00
abstract::An investigation was performed of the changes in image quality and patient dose as a result of increasing filtration for fluoroscopy performed under automatic brightness control. Filtration was added either at the x-ray tube housing (i.e., scatter-free geometry) or adjacent to a tissue equivalent phantom simulating th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597906
更新日期:1997-03-01 00:00:00
abstract::A commercially available open MRI unit is under routine use for radiation therapy simulation. The effects of a gradient distortion correction (GDC) program used to post process the images were assessed by comparison with the known geometry of a phantom. The GDC reduced the magnitude of the distortions at the periphery...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1513991
更新日期:2002-11-01 00:00:00
abstract:PURPOSE:Four-dimensional volumetric modulated arc therapy (4D VMAT) and four-dimensional intensity-modulated radiotherapy (4D IMRT) are developing radiation therapy treatment strategies designed to maximize dose conformality, minimize normal tissue dose, and deliver the treatment as efficiently as possible. The patient...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12778
更新日期:2018-04-01 00:00:00
abstract:PURPOSE:We studied the sensitivity of a novel transmission fiber scintillator array designed and built for in line treatment verification. The purpose of this project is to assess the capability of the fiber detector array technology to detect treatment errors in real time without false positives to enhance patient saf...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735217
更新日期:2012-06-01 00:00:00
abstract::Up to the present, the majority of low contrast object evaluations performed on phantom images have been accomplished in a subjective fashion. This is mainly due to the time and effort required to manually measure each radiograph with a densitometer to obtain quantitative results. However, with the development of digi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1543153
更新日期:2003-03-01 00:00:00
abstract:PURPOSE:Wide-angle free-air chambers (WAFACs) are used as primary standard measurement devices for establishing the air-kerma strength of low-energy, low-dose rate brachytherapy seeds. The National Research Council of Canada (NRC) is commissioning a primary standard wide-angle free-air chamber (NRC WAFAC) to serve the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4951727
更新日期:2016-07-01 00:00:00
abstract:PURPOSE:Although small animal image-guided radiotherapy (SA-IGRT) systems are used increasingly in preclinical research, tools for performing routine quality assurance (QA) have not been optimized and are not readily available. Robust, efficient, and reliable QA tools are needed to ensure the accuracy and reproducibili...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12939
更新日期:2018-07-01 00:00:00
abstract::Encapsulated, cylindrical sources containing 2, 5, and 8 Ci of 241Am have been designed and fabricated for intracavitary irradiation of uterine cancers. Exposure rates in air and dose rates in water around these sources have been measured using an ionization chamber and a lithium fluoride thermoluminescent dosimetry s...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596007
更新日期:1987-09-01 00:00:00
abstract::An analytic representation proposed for the relative intensity distribution of the extra-focal source in a two-component x-ray source model serves as the basis for calculation. From this representation, a closed-form expression for head scatter factors defined on the central beam axis is derived by integrating over th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597494
更新日期:1995-12-01 00:00:00
abstract::An applicator system for intraoperative radiation therapy has been fabricated which does not require physical docking with the accelerator. A dosimetric study has been completed which documents the properties of this system for a variety of electron beam energies, applicator sizes, collimator settings, both primary an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596338
更新日期:1989-09-01 00:00:00
abstract:PURPOSE:To provide specific experience-based guidance and recommendations for centers wishing to develop, validate, and implement an accurate and efficient process for directly using positron emission tomography-computed tomography (PET-CT) for the radiotherapy planning of head and neck cancer patients. METHODS:A PET-...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4867856
更新日期:2014-04-01 00:00:00
abstract::Direct comparisons of the National Institute of Standards and Technology's (NIST) Ritz 20 kV to 100 kV standard free-air ionization chamber and a portable variable-length free-air ionization chamber designed by the University of Wisconsin-Madison Accredited Dosimetry Calibration Laboratory (UW-ADCL) were made on NISTs...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598148
更新日期:1997-08-01 00:00:00
abstract::Frequent and repeated imaging procedures such as those performed in image-guided radiotherapy (IGRT) programs may add significant dose to radiosensitive organs of radiotherapy patients. It has been shown that kV-CBCT results in doses to bone that are up to a factor of 3-4 higher than those in surrounding soft tissue. ...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.3014197
更新日期:2008-12-01 00:00:00
abstract:PURPOSE:In our institute, the MatriXX has been used for IMRT, VMAT and dynamic arc QA. However, the small fields (<3cm) shaped by HDMLC for SRS dynamic arc (DA) present QA measurement issues when using the MatriXX due to its limited resolution (7.6 mm). A recently available portal dosimetry (PD) software tool in Eclips...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735167
更新日期:2012-06-01 00:00:00
abstract::Soft-tissue detectability in cone-beam computed tomography (CBCT) was evaluated via two-alternative forced-choice (2AFC) tests. Investigations included the dependence of detectability on radiation dose, the influence of the asymmetric three-dimensional (3D) noise-power spectrum (NPS) in axial and sagittal or coronal p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2790586
更新日期:2007-11-01 00:00:00
abstract:PURPOSE:To develop an automatic knot placement algorithm to enable the use of NonUniform Rational B-Splines (NURBS) in deformable image registration. METHODS:The authors developed a two-step approach to fit a known displacement vector field (DVF). An initial fit was made with uniform knot spacing. The error generated ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3609416
更新日期:2011-08-01 00:00:00
abstract:PURPOSE:The aim of this study was to assess the suitability of Gafchromic EBT3 films for reference dose measurements in the beam of a prototype high dose-per-pulse linear accelerator (linac), capable of delivering electron beams with a mean dose-rate (Ḋm ) ranging from 0.07 to 3000 Gy/s and a dose-rate in pulse (Ḋp ) o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12066
更新日期:2017-02-01 00:00:00
abstract::A proton dose computational algorithm, performing an analytical superposition of infinitely narrow proton beamlets (ASPB) is introduced. The algorithm uses the standard pencil beam technique of laterally distributing the central axis broad beam doses according to the Moliere scattering theory extended to slablike vary...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2064887
更新日期:2005-12-01 00:00:00
abstract:PURPOSE:To perform radiomic analysis of primary tumors extracted from pretreatment contrast-enhanced computed tomography (CE-CT) images for patients with oropharyngeal cancers to identify discriminant features and construct an optimal classifier for the characterization and prediction of human papilloma virus (HPV) sta...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13977
更新日期:2020-02-01 00:00:00
abstract:PURPOSE:Both spatial and biological information are necessary in order to perform true optimization of a treatment plan and for predicting clinical outcome. The goal of this work is to develop an enhanced treatment plan evaluation tool which incorporates biological parameters and retains spatial dose information. METH...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3497152
更新日期:2010-11-01 00:00:00
abstract::Myocardial beta adrenergic receptor (beta-AR) concentration can substantially decrease in congestive heart failure and significantly increase in chronic volume overload, such as in severe aortic valve regurgitation. Positron emission tomography (PET) with an appropriate ligand-receptor model can be used for noninvasiv...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2402585
更新日期:2007-01-01 00:00:00
abstract:PURPOSE:Computational models are widely used during the design and characterization of microwave ablation (MWA) devices, and have been proposed for pretreatment planning. Our objective was to assess three-dimensional (3D) transient temperature and ablation profiles predicted by MWA computational models with temperature...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14318
更新日期:2020-09-01 00:00:00
abstract::The computational aspects of the design of an optical distance indicator (ODI) for use with a radiation therapy accelerator are discussed. The specifics of the optical and mechanical design of an ODI for use with a superconducting cyclotron used for fast neutron therapy are presented. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598510
更新日期:1999-02-01 00:00:00
abstract:PURPOSE:This report describes upgrades and performance characterization of an experimental benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system capable of determining the spatial distribution and concentration of metal probes such as gold nanoparticles (GNPs). Specifically, a high-power (~3 kW) indus...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13138
更新日期:2018-10-01 00:00:00
abstract:PURPOSE:To develop a practical background compensation (BC) technique to improve quantitative (90)Y-bremsstrahlung single-photon emission computed tomography (SPECT)/computed tomography (CT) using a commercially available imaging system. METHODS:All images were acquired using medium-energy collimation in six energy wi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4960629
更新日期:2016-09-01 00:00:00
abstract::Studies suggest that clinical outcomes are improved in repeat trigeminal neuralgia (TN) Gamma Knife radiosurgery if a different part of the nerve from the previous radiosurgery is treated. The MR images taken in the first and repeat radiosurgery need to be coregistered to map the first radiosurgery volume onto the sec...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1944287
更新日期:2005-07-01 00:00:00
abstract:PURPOSE:To design volume-specific breast phantoms from breast CT (bCT) data sets and estimate the associated normalized mean glandular dose coefficients for breast CT using Monte Carlo methods. METHODS:A large cohort of bCT data sets (N = 215) was used to evaluate breast volume into quintiles (plus the top 5%). The av...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12477
更新日期:2017-10-01 00:00:00
abstract:PURPOSE:High-Z material in computed tomography (CT) yields metal artifacts that degrade image quality and may cause substantial errors in dose calculation. This study couples a metal artifact reduction (MAR) algorithm with enhanced 16-bit depth (vs standard 12-bit) to quantify potential gains in image quality and dosim...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4805102
更新日期:2013-06-01 00:00:00