Development and implementation of EPID-based quality assurance tests for the small animal radiation research platform (SARRP).

Abstract:

PURPOSE:Although small animal image-guided radiotherapy (SA-IGRT) systems are used increasingly in preclinical research, tools for performing routine quality assurance (QA) have not been optimized and are not readily available. Robust, efficient, and reliable QA tools are needed to ensure the accuracy and reproducibility of SA-IGRT systems. Several investigators have reported custom-made phantoms and protocols for SA-IGRT systems QA. These are typically time and resource intensive and are therefore not well suited to the preclinical radiotherapy environment, in which physics support is limited and routine QA is performed by technical staff. We investigated the use of the inbuilt electronic portal imaging device (EPID) to develop and validate routine QA tests and procedures. In this work, we focus on the Xstrahl Small Animal Radiation Research Platform (SARRP) EPID. However, the methodology and tests developed here are applicable to any SA-IGRT system that incorporates an EPID. METHODS:We performed a comprehensive characterization of the dosimetric properties of the camera-based EPID at kilovoltage energies over a 11-month period, including detector warm-up time, radiation dose history effect, stability and short- and long-term reproducibility, gantry angle dependency, output factor, and linearity of the EPID response. We developed a test to measure the constancy of beam quality in terms of half-value layer and tube peak potential using the EPID. We verified the SARRP daily output and beam profile constancy using the imager. We investigated the use of the imager to monitor beam-targeting accuracy at various gantry and couch angles. RESULTS:The EPID response was stable and reproducible, exhibiting maximum variations of ≤0.3% and ≤1.9% for short and long terms, respectively. The detector showed no dependence on response at different gantry angles, with a maximum variation ≤0.5%. We found close agreement in output factor measurement between the portal imager and reference dosimeters, with maximum differences ≤3% for ionization chamber and ≤1.7% for Gafchromic EBT3 dosimetry film, respectively. We have shown that the EPID response is linear with tube current (mA) for the entire range of tube kilovoltage peak. Notably, a close relationship was seen between the detector response vs mA slope, and the kilovoltage peak, allowing an independent verification of kilovoltage peak stability based solely on EPID response. In addition to dosimetry tests, according to the beam-targeting measurement using portal images, maximum displacement of the central axis of the x-ray beam (due to sag) was 0.76 ± 0.09 mm at gantry 135°/couch 0° and 0.89 ± 0.06 mm at gantry 0°/couch -135°. CONCLUSION:We performed the first comprehensive analysis on the dosimetric properties of an EPID operating at kilovoltage x-ray energies. We characterized the detector performance over a 11-month period. Our results indicate that the imager is a stable and convenient tool for SARRP routine QA tests. We then developed EPID-based tests to perform routine SA-IGRT systems QA tasks, such as verifying constancy of beam quality, energy, output, and profile measurements, relative output factors, and beam targeting.

journal_name

Med Phys

journal_title

Medical physics

authors

Anvari A,Poirier Y,Sawant A

doi

10.1002/mp.12939

subject

Has Abstract

pub_date

2018-07-01 00:00:00

pages

3246-3257

issue

7

eissn

0094-2405

issn

2473-4209

journal_volume

45

pub_type

杂志文章
  • Stereotactic mammography imaging combined with 3D US imaging for image guided breast biopsy.

    abstract::Stereotactic X-ray mammography (SM) and ultrasound (US) guidance are both commonly used for breast biopsy. While SM provides three-dimensional (3D) targeting information and US provides real-time guidance, both have limitations. SM is a long and uncomfortable procedure and the US guided procedure is inherently two dim...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2794175

    authors: Surry KJ,Mills GR,Bevan K,Downey DB,Fenster A

    更新日期:2007-11-01 00:00:00

  • Statistical analysis of dose-volume and dose-wall histograms for rectal toxicity following 3D-CRT in prostate cancer.

    abstract::The purpose of this paper is to determine the correlation between dose-volume histogram (DVH) and dose wall-histogram (DWH) in the evaluation of rectal complications for prostate cancer patients treated with three-dimensional conformal radiotherapy (3D-CRT). A retrospective analysis of DVHs and DWHs of a subset of 25 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1951427

    authors: García-Vicente F,Zapatero A,Floriano A,Cruz-Conde A,Perez L,Marín A,Mínguez C,Torres JJ

    更新日期:2005-08-01 00:00:00

  • MO-D-BRB-11: Out-Of-Field Dose Measurements in Radiotherapy Using Photons and Particles.

    abstract:PURPOSE:Within the European project ALLEGRO (grant agreement no. 231965), the out-of-field dose delivered to a patient when treated with different radiotherapy modalities was investigated. The study compared the dose distribution during photon and particle irradiations both in a water and an anthropomorphic phantom to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735792

    authors: Kaderka R,Durante M,Berger T,Reitz G,Tessa C

    更新日期:2012-06-01 00:00:00

  • Feasibility study of patient-specific energy verification using a multilayer acrylic-disk radiation sensor.

    abstract:PURPOSE:Obtaining an integral depth-dose (IDD) curve using a recently developed acrylic-disk radiation sensor (ADRS) is time-consuming because its single structure requires point-by-point measurements in a water phantom. The goal of this study was to verify the ability of a newly designed multilayer ADRS, composed of 2...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14326

    authors: Son J,Shin D,Kim T,Park S,Rah JE

    更新日期:2020-09-01 00:00:00

  • Voxel clustering for quantifying PET-based treatment response assessment.

    abstract:PURPOSE:Imaging biomarkers are crucial in managing treatment options for cancer patients. They are extremely powerful tools since they allow personalized treatment assessment early during therapy by using repeated imaging to detect and quantify tumor response. Currently, treatment response assessment from consecutive i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4764900

    authors: Schreibmann E,Waller AF,Crocker I,Curran W,Fox T

    更新日期:2013-01-01 00:00:00

  • Classifier performance prediction for computer-aided diagnosis using a limited dataset.

    abstract::In a practical classifier design problem, the true population is generally unknown and the available sample is finite-sized. A common approach is to use a resampling technique to estimate the performance of the classifier that will be trained with the available sample. We conducted a Monte Carlo simulation study to co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2868757

    authors: Sahiner B,Chan HP,Hadjiiski L

    更新日期:2008-04-01 00:00:00

  • Assessment of a new multileaf collimator concept using GEANT4 Monte Carlo simulations.

    abstract::The aim of the work was to investigate in advance the dosimetric properties of a new multileaf collimator (MLC) concept with the help of Monte Carlo (MC) simulations prior to the production of a prototype. The geometrical design of the MLC was implemented in the MC code GEANT4. For the simulation of a 6 MV treatment b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2181298

    authors: Tacke MB,Szymanowski H,Oelfke U,Schulze C,Nuss S,Wehrwein E,Leidenberger S

    更新日期:2006-04-01 00:00:00

  • Characterization of scintillator-based detectors for few-ten-keV high-spatial-resolution x-ray imaging.

    abstract:PURPOSE:High-spatial-resolution x-ray imaging in the few-ten-keV range is becoming increasingly important in several applications, such as small-animal imaging and phase-contrast imaging. The detector properties critically influence the quality of such imaging. Here the authors present a quantitative comparison of scin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4948687

    authors: Larsson JC,Lundström U,Hertz HM

    更新日期:2016-06-01 00:00:00

  • Principles in positioning cross-projecting lasers.

    abstract::With the increased sophistication of lasers used for patient positioning in radiotherapy comes increased possibilities for mistakes in installing the lasers, which can result in serious patient positioning errors. Two principles must be followed when mounting cross-projecting lasers: (1) the horizontal line must be on...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594960

    authors: Thomadsen BR

    更新日期:1981-05-01 00:00:00

  • Accelerated barrier optimization compressed sensing (ABOCS) reconstruction for cone-beam CT: phantom studies.

    abstract:PURPOSE:Recent advances in compressed sensing (CS) enable accurate CT image reconstruction from highly undersampled and noisy projection measurements, due to the sparsifiable feature of most CT images using total variation (TV). These novel reconstruction methods have demonstrated advantages in clinical applications wh...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4729837

    authors: Niu T,Zhu L

    更新日期:2012-07-01 00:00:00

  • Technical Note: Experimental determination of the effective point of measurement of two cylindrical ionization chambers in a clinical proton beam.

    abstract:PURPOSE:IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4921617

    authors: Sugama Y,Nishio T,Onishi H

    更新日期:2015-07-01 00:00:00

  • Application of spherical diodes for megavoltage photon beams dosimetry.

    abstract:PURPOSE:External beam radiation therapy (EBRT) usually uses heterogeneous dose distributions in a given volume. Designing detectors for quality control of these treatments is still a developing subject. The size of the detectors should be small to enhance spatial resolution and ensure low perturbation of the beam. A hi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4837178

    authors: Barbés B,Azcona JD,Burguete J,Martí-Climent JM

    更新日期:2014-01-01 00:00:00

  • Breast tumor segmentation in 3D automatic breast ultrasound using Mask scoring R-CNN.

    abstract:PURPOSE:Automatic breast ultrasound (ABUS) imaging has become an essential tool in breast cancer diagnosis since it provides complementary information to other imaging modalities. Lesion segmentation on ABUS is a prerequisite step of breast cancer computer-aided diagnosis (CAD). This work aims to develop a deep learnin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14569

    authors: Lei Y,He X,Yao J,Wang T,Wang L,Li W,Curran WJ,Liu T,Xu D,Yang X

    更新日期:2020-10-30 00:00:00

  • Using FDG-PET activity as a surrogate for tumor cell density and its effect on equivalent uniform dose calculation.

    abstract::The concept of equivalent uniform dose (EUD) has been suggested as a means to quantitatively consider heterogeneous dose distributions within targets. Tumor cell density/function is typically assumed to be uniform. We herein propose to use 18F-labeled 2-deoxyglucose (FDG) positron emission tomography (PET) tumor imagi...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1779372

    authors: Zhou SM,Wong TZ,Marks LB

    更新日期:2004-09-01 00:00:00

  • First Measurements of Ionization Cluster-Size Distributions with a Compact Nanodosimeter.

    abstract:PURPOSE:A nanodosimeter is a type of detector which measures single ionizations in a small gaseous volume in order to obtain ionization cluster size probability distributions for characterization of radiation types. Working nanodosimeter detectors are usually bulky machines which require a lot of space. In this work, t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14738

    authors: Vasi F,Schneider U

    更新日期:2021-01-28 00:00:00

  • SU-E-T-459: Radiobiological Evaluation of Implant Duration and Radionuclide Selection for COMS Eye Plaque Brachytherapy Using an Objective Function.

    abstract:PURPOSE:The biologically effective dose (BED) of temporary brachytherapy treatments is a function of both chosen radionuclide (R) and implant duration (T). This study endeavored to evaluate BED delivered to the tumor volume and surrounding ocular structures as a function of plaque position (P), prescription dose, R, an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735548

    authors: Gagne N,Rivard M

    更新日期:2012-06-01 00:00:00

  • A real-time prostate cancer detection technique using needle insertion force and patient-specific criteria during percutaneous intervention.

    abstract::In this article, the authors present a novel real-time cancer detection technique by using needle insertion forces in conjunction with patient-specific criteria during percutaneous interventions. Needle insertion experiments and pathological analysis were performed for developing a computer-aided detection (CAD) model...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3148834

    authors: Yan K,Li L,Joseph J,Rubens DR,Messing EM,Liao L,Yu Y

    更新日期:2009-07-01 00:00:00

  • Eye tracking and gating system for proton therapy of orbital tumors.

    abstract:PURPOSE:A new motion-based gated proton therapy for the treatment of orbital tumors using real-time eye-tracking system was designed and evaluated. METHODS:We developed our system by image-pattern matching, using a normalized cross-correlation technique with LabVIEW 8.6 and Vision Assistant 8.6 (National Instruments, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4729708

    authors: Shin D,Yoo SH,Moon SH,Yoon M,Lee SB,Park SY

    更新日期:2012-07-01 00:00:00

  • Optimization of radiography applications using x-ray beams emitted by compact accelerators. Part I. Monte Carlo study of the hard x-ray spectrum.

    abstract:PURPOSE:A 3-year project called LABSYNC has been recently funded by the European Commission, with the aim of designing a radiation facility based on a compact light source, i.e., a laboratory-sized commercial synchrotron, capable of accelerating electrons up to 6 or 20 MeV. An accurate spectral description of hard x ra...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3223357

    authors: Marziani M,Taibi A,Di Domenico G,Gambaccini M

    更新日期:2009-10-01 00:00:00

  • 4D DMLC leaf sequencing to minimize organ at risk dose in moving anatomy.

    abstract::The most favorable treatment for moving body anatomy should aim at utilizing organ motion to minimize the dose to sensitive structures without compromising the dose delivered to the target. The solution of the problem of appropriate intensity redistribution over different phases of body motion is achievable in dynamic...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.2804722

    authors: Papiez L,McMahon R,Timmerman R

    更新日期:2007-12-01 00:00:00

  • Calibration of 192Ir high-dose-rate afterloading systems.

    abstract::A method is described for calibration of 192Ir high-dose-rate (HDR) brachytherapy afterloading systems. Since NIST does not offer calibration of ionization chambers with the gamma-ray spectrum of iridium-192, an interpolation procedure is employed, using calibrations above (137Cs, 662 keV) and below (250 kVcp, 146-keV...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596649

    authors: Goetsch SJ,Attix FH,Pearson DW,Thomadsen BR

    更新日期:1991-05-01 00:00:00

  • Registration of clinical volumes to beams-eye-view images for real-time tracking.

    abstract:PURPOSE:The authors combine the registration of 2D beam's eye view (BEV) images and 3D planning computed tomography (CT) images, with relative, markerless tumor tracking to provide automatic absolute tracking of physician defined volumes such as the gross tumor volume (GTV). METHODS:During treatment of lung SBRT cases...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4900603

    authors: Bryant JH,Rottmann J,Lewis JH,Mishra P,Keall PJ,Berbeco RI

    更新日期:2014-12-01 00:00:00

  • Iodine quantification in limited angle tomography.

    abstract:PURPOSE:To develop and test the feasibility of a two-pass iterative reconstruction algorithm with material decomposition designed to obtain quantitative iodine measurements in digital breast tomosynthesis. METHODS:Contrast-enhanced mammography has shown promise as a cost-effective alternative to magnetic resonance ima...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14400

    authors: Michielsen K,Rodríguez-Ruiz A,Reiser I,Nagy JG,Sechopoulos I

    更新日期:2020-10-01 00:00:00

  • An evaluation of ionization chambers for the relative dosimetry of kilovoltage x-ray beams.

    abstract::In this work, the authors have evaluated ten different ionization chambers for the relative dosimetry of kilovoltage x-ray beams in the energy range of 50-280 kVp. Percentage depth doses in water and relative detector response (in Solid Water and in air) were measured for each of the x-ray beams studied using a number...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3183820

    authors: Hill R,Mo Z,Haque M,Baldock C

    更新日期:2009-09-01 00:00:00

  • Technical Note: Comparison of peripheral patient dose from MR-guided 60 Co therapy and 6 MV linear accelerator IGRT.

    abstract:PURPOSE:The use of X-ray imaging in radiation therapy can give a substantial dose to the patient. A Cobalt machine combined with an magnetic resonance imaging (MRI) was recently introduced to clinical work. One positive aspect of using non-ionizing imaging devices is the reduction of the patient exposure. The purpose o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12293

    authors: Hauri P,Hälg RA,Schneider U

    更新日期:2017-07-01 00:00:00

  • Automatic tumor segmentation in breast ultrasound images using a dilated fully convolutional network combined with an active contour model.

    abstract:PURPOSE:Due to the low contrast, blurry boundaries, and large amount of shadows in breast ultrasound (BUS) images, automatic tumor segmentation remains a challenging task. Deep learning provides a solution to this problem, since it can effectively extract representative features from lesions and the background in BUS i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13268

    authors: Hu Y,Guo Y,Wang Y,Yu J,Li J,Zhou S,Chang C

    更新日期:2019-01-01 00:00:00

  • A method for avoiding overlap of left and right lungs in shape model guided segmentation of lungs in CT volumes.

    abstract:PURPOSE:The automated correct segmentation of left and right lungs is a nontrivial problem, because the tissue layer between both lungs can be quite thin. In the case of lung segmentation with left and right lung models, overlapping segmentations can occur. In this paper, the authors address this issue and propose a so...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4894817

    authors: Gill G,Bauer C,Beichel RR

    更新日期:2014-10-01 00:00:00

  • Feasibility study on inverse four-dimensional dose reconstruction using the continuous dose-image of EPID.

    abstract:PURPOSE:When an intensity-modulated radiation beam is delivered to a moving target, the interplay effect between dynamic beam delivery and the target motion due to miss-synchronization can cause unpredictable dose delivery. The portal dose image in electronic portal imaging device (EPID) represents radiation attenuated...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4799941

    authors: Yeo IJ,Jung JW,Yi BY,Kim JO

    更新日期:2013-05-01 00:00:00

  • Evaluation of tumor localization in respiration motion-corrected cone-beam CT: prospective study in lung.

    abstract:PURPOSE:Target localization accuracy of cone-beam CT (CBCT) images used in radiation treatment of respiratory disease sites is affected by motion artifacts (blurring and streaking). The authors have previously reported on a method of respiratory motion correction in thoracic CBCT at end expiration (EE). The previous re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4896101

    authors: Dzyubak O,Kincaid R,Hertanto A,Hu YC,Pham H,Rimner A,Yorke E,Zhang Q,Mageras GS

    更新日期:2014-10-01 00:00:00

  • A two-step algorithm for predicting portal dose images in arbitrary detectors.

    abstract::Recently, portal imaging systems have been successfully demonstrated in dosimetric treatment verification applications, where measured and predicted images are quantitatively compared. To advance this approach to dosimetric verification, a two-step model which predicts dose deposition in arbitrary portal image detecto...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1289375

    authors: McCurdy BM,Pistorius S

    更新日期:2000-09-01 00:00:00