Abstract:
:The most favorable treatment for moving body anatomy should aim at utilizing organ motion to minimize the dose to sensitive structures without compromising the dose delivered to the target. The solution of the problem of appropriate intensity redistribution over different phases of body motion is achievable in dynamic multileaf collimator (DMLC) intensity modulated radiation therapy delivery, due to the fact that multiple solutions are admissible for imposing the same intensity map over a moving target in this technique of irradiation. The realization of this type of delivery provides a treatment methodology that delivers treatment plans for moving patient anatomy that are superior to any treatments possible for static patient body anatomy. This paper is devoted to exploring this idea. To this end, a simple, though clinically realistic example is developed and presented that shows modified DMLC leaf motions that deliver a predetermined intensity to a moving target while reducing the dose delivered to organs at risk.
journal_name
Med Physjournal_title
Medical physicsauthors
Papiez L,McMahon R,Timmerman Rdoi
10.1118/1.2804722subject
Has Abstractpub_date
2007-12-01 00:00:00pages
4952-6issue
12eissn
0094-2405issn
2473-4209journal_volume
34pub_type
信件相关文献
MEDICAL PHYSICS文献大全abstract::The purpose of this work is to calculate the dose perturbations due to the presence of iodine contrast media in catheter-based intravascular brachytherapy (IVBT). The EGSnrc Monte Carlo system was used to perform the calculation for the two most commonly used beta and gamma sources (90Sr and 192Ir as well as for a var...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1367279
更新日期:2001-05-01 00:00:00
abstract:PURPOSE:To compare optimization characteristics, plan quality, and treatment delivery efficiency between total marrow irradiation (TMI) plans using the new TomoTherapy graphic processing unit (GPU) based dose engine and CPU/cluster based dose engine. METHODS:Five TMI plans created on an anthropomorphic phantom were op...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4810936
更新日期:2013-07-01 00:00:00
abstract::CEA TVS film is a therapy verification film that has been recently introduced in the North American market. This film features linear characteristic curves for photon energies from 137Cs to 18 MV as reported by Cheng and Das [Med. Phys. 23, 1225 (1996)]. In Saskatoon, TVS film was investigated for its application in t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598316
更新日期:1998-08-01 00:00:00
abstract::We have reported in our previous studies on the methodology, and feasibility of 4D-PET (Gated PET) acquisition, to reduce respiratory motion artifact in PET imaging of the thorax. In this study, we expand our investigation to address the problem of respiration motion in PET/CT imaging. The respiratory motion of four l...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1118/1.1809778
更新日期:2004-12-01 00:00:00
abstract::The use of magnetic resonance imaging as a readout method for polymer gel dosimetry commonly involves long imaging sessions, particularly when high spatial resolution is required in all three dimensions, for the investigation of dose distributions with steep dose gradients and stringent dose delivery specifications. I...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2065367
更新日期:2005-11-01 00:00:00
abstract:PURPOSE:The authors have developed a system that monitors intrafractional target motion perpendicular to the treatment beam with the aid of radioopaque markers by means of separating kV image and megavoltage (MV) treatment field on a single flat-panel detector. METHODS:They equipped a research Siemens Artiste linear a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3665712
更新日期:2012-01-01 00:00:00
abstract:PURPOSE:In fluoroscopy-guided clinical procedures that involve tracking objects over long treatment times, there is a need for reducing the amount of imaging dose delivered to the patient and the operating staff. In this study, we introduce a feedback metric to minimize tube current while maintaining a targeting precis...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734878
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The implementation of an accurate beam model is an integral part of the commissioning of any planning system. This process is especially challenging in the case of IMRT beam models owing to the complexity of small field sizes and MLC leaf-end and tongue-and-groove effects. The question of how to judge the quali...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735679
更新日期:2012-06-01 00:00:00
abstract::A computerized scheme is being developed for the detection of masses in digital mammograms. Based on the deviation from the normal architectural symmetry of the right and left breasts, a bilateral subtraction technique is used to enhance the conspicuity of possible masses. The scheme employs two pairs of conventional ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596610
更新日期:1991-09-01 00:00:00
abstract:PURPOSE:Many biological objects, including neuronal dendrites, blood vasculature, airways, phylogenetic trees, produce tree structured data. Current methods of analysis either ignore the complex structure of trees or use distance-based methods which limit the scope of multivariate modeling. METHODS:We propose a branch...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12751
更新日期:2018-03-01 00:00:00
abstract:PURPOSE:Computer-aided diagnosis (CAD) systems assist in solving subjective diagnosis problems that typically rely on personal experience. A CAD system has been developed to differentiate malignant thyroid nodules from benign thyroid nodules in ultrasound images based on deep learning methods. The diagnostic performanc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14301
更新日期:2020-09-01 00:00:00
abstract:PURPOSE:Treatments like radiotherapy and focused ultrasound in the abdomen require accurate motion tracking, in order to optimize dosage delivery to the target and minimize damage to critical structures and healthy tissues around the target. 4D ultrasound is a promising modality for motion tracking during such treatmen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4890091
更新日期:2014-08-01 00:00:00
abstract:PURPOSE:The need for an accurate lesion segmentation tool in 18FDG PET is a prerequisite for the estimation of lesion response to therapy, for radionuclide dosimetry, and for the application of 18FDG PET to radiotherapy planning. In this work, the authors have developed an iterative method based on a mathematical fit d...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3222732
更新日期:2009-10-01 00:00:00
abstract:PURPOSE:Calculations of deoxyribonucleic acid (DNA) damages involve many parameters in the computation process. As these parameters are often subject to uncertainties, it is of central importance to comprehensively quantify their impacts on DNA single-strand break (SSB) and double-strand break (DSB) yields. This has be...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14036
更新日期:2020-04-01 00:00:00
abstract:PURPOSE:Talbot-Lau x-ray interferometry provides information about the scattering and refractive properties of an object - in addition to the object's attenuation features. Until recently, this method was ineligible for imaging human-sized objects as it is challenging to adapt Talbot-Lau interferometers (TLIs) to the r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12889
更新日期:2018-06-01 00:00:00
abstract::Tissue absorbed dose (D) is a computed result for internal emitters. For fixed geometries, D is calculated by a matrix (S) multiplication of the integrated activity vector (Ã). The last quantity is usually measured by nuclear imaging of activity in various source organs and performing a temporal integration. Ã is the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735750
更新日期:2012-06-01 00:00:00
abstract::Conventional chest radiography is limited by the presence of scattered radiation and the small useful exposure range of radiographic film. A computer-assisted scanning system to minimize these two effects is outlined. The system uses a small beam of radiation swept over the patient's chest in a raster pattern to expos...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595327
更新日期:1983-09-01 00:00:00
abstract::The purpose of this study was to investigate the effect of z overscanning on eye lens dose and effective dose received by pediatric patients undergoing head CT examinations. A pediatric patient study was carried out to obtain the exposure parameters and data regarding the eye lens position with respect to imaged volum...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2207212
更新日期:2006-07-01 00:00:00
abstract:PURPOSE:To improve image quality and reduce imaging dose in CBCT for radiation therapy applications and to realize near real-time image reconstruction based on use of a fast convergence iterative algorithm and acceleration by multi-GPUs. METHODS:An iterative image reconstruction that sought to minimize a weighted leas...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735747
更新日期:2012-06-01 00:00:00
abstract::An algorithm, which combines the scanning beam with dynamic collimation to generate any arbitrary intensity profile, is presented. The desired intensity profile is assumed to be piecewise linear. The dynamic collimation method used is the "sliding window." The algorithm can be used either for a given scanning beam pro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597672
更新日期:1996-01-01 00:00:00
abstract:PURPOSE:The spatial resolution of iterative reconstruction (IR) in computed tomography (CT) is contrast- and noise-dependent because of the nonlinear regularization. Due to the severe noise contamination, it is challenging to perform precise spatial-resolution measurements at very low-contrast levels. The purpose of th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4916802
更新日期:2015-05-01 00:00:00
abstract:PURPOSE:Adding magnetic resonance (MR)-derived information to standard transrectal ultrasound (TRUS) images for guiding prostate biopsy is of substantial clinical interest. A tumor visible on MR images can be projected on ultrasound (US) by using MR-US registration. A common approach is to use surface-based registratio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4917481
更新日期:2015-05-01 00:00:00
abstract:PURPOSE:Multiple anatomy optimization (MAO) utilizing deformable dose accumulation on entire 4DCT data sets is implemented to overcome ambiguity between optimal dose defined on a single anatomy and optimal accumulated dose resulting from dose delivery to moving and deforming anatomy. METHODS:Six lung cancer patients a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735744
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Developed herein is a three-dimensional (3D) flow contrast imaging system leveraging advancements in the extension of laser speckle contrast imaging theories to deep tissues along with our recently developed finite-element diffuse correlation tomography (DCT) reconstruction scheme. This technique, termed speckl...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4922206
更新日期:2015-07-01 00:00:00
abstract::This study presents experimental results about the effective depth of penetration and about the radiofrequency (rf) power absorption in humans as a function of frequency. The frequency range investigated covers 10 up to 220 MHz. For the main part, the results were derived from bench measurements of the quality factor ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595995
更新日期:1987-11-01 00:00:00
abstract::The objective of this study was to compare the contrast-detail performance of five different commercial liquid crystal displays (LCDs) to other LCD and cathode-ray tube (CRT) displays for medical applications. A contrast-detail phantom, supplemented with 5 in. of acrylic, was imaged on a commercial digital radiographi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2868780
更新日期:2008-04-01 00:00:00
abstract:PURPOSE:Radiation scattered from the breast in digital breast tomosynthesis (DBT) causes image degradation, including loss of contrast between cancerous and background tissue. Unlike in 2-dimensional (2D) mammography, an antiscatter grid cannot readily be used in DBT because changing alignment between the tube and dete...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4943632
更新日期:2016-04-01 00:00:00
abstract:PURPOSE:There are several options to consider in the design of a vault that will house a cyclotron for radioisotopes production with regards to the door entrance. Alternatives are a direct-shielded door, a simple maze, or a double-legged maze. In this work, the impact of the neutron and photon doses at the vault entran...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3515458
更新日期:2010-12-01 00:00:00
abstract:PURPOSE:To characterize the radiation dose and three-dimensional (3D) imaging performance of a recently developed mobile, isocentric C-arm equipped with a flat-panel detector (FPD) for intraoperative cone-beam computed tomography (CBCT) (Cios Spin 3D, Siemens Healthineers) and to identify potential improvements in 3D i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13983
更新日期:2020-03-01 00:00:00
abstract::The purpose of this paper is to develop a method that reduces the number of segments for intensity modulated arc therapy (IMAT) and intensity modulated radiotherapy (IMRT) for concave target volumes (TV). The aim was to utilize no more than two intensity levels per organ at risk (OAR) and to derive both optimal segmen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1861161
更新日期:2005-03-01 00:00:00