Abstract:
PURPOSE:Many biological objects, including neuronal dendrites, blood vasculature, airways, phylogenetic trees, produce tree structured data. Current methods of analysis either ignore the complex structure of trees or use distance-based methods which limit the scope of multivariate modeling. METHODS:We propose a branching process model which enables analysis of both the branching structure and associated properties. Our novel parametrization preserves an important aspect of tree structure, namely its branch order. The model is amenable to standard methods of analysis, like generalized linear/additive models. RESULTS:The model fit the distribution of the observed data quite well when applied to a collection of 98 brain artery systems. The estimated probability of branching decreases log linearly with branch order. Likewise, the average diameter of arteries decreases, while average length increases with branch order. Frontal arterial branches are on average longer and thinner than those in the back at equivalent branch orders. A mechanistic arterial branching model based on Poiseuille's blood flow law, which uses vessel length and diameter information, fit the observed branching structure significantly better. This model is further improved by including branch order, suggesting viscoelastic flow impacts branching in narrower vessels. CONCLUSION:After adjustment for branch order, brain arterial branching probabilities decreased significantly with age and length, but increased with diameter. Arteries become thicker and branch less frequently with increasing age, but the age effect decreases with branch order.
journal_name
Med Physjournal_title
Medical physicsauthors
Roy Choudhury K,Skwerer Sdoi
10.1002/mp.12751subject
Has Abstractpub_date
2018-03-01 00:00:00pages
1123-1134issue
3eissn
0094-2405issn
2473-4209journal_volume
45pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::The physical characteristics of a clinical charge coupled device (CCD)-based imager (Senovision, GE Medical Systems, Milwaukee, WI) for small-field digital mammography have been investigated. The imager employs a MinR 2000 (Eastman Kodak Company, Rochester, NY) scintillator coupled by a 1:1 optical fiber to a front-il...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1286720
更新日期:2000-08-01 00:00:00
abstract::An important aspect of the intensity modulated radiotherapy (IMRT) process is that of optimizing the beam intensity profiles. Most such methods use a comparison between the defined dose distribution (including prescription dose and dose limits for critical structures) and the current distribution. The comparison may i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1428756
更新日期:2002-01-01 00:00:00
abstract:PURPOSE:In the practice code of dosimetry, humidity effect is assumed to be constant as far as the measurements are performed in the relative humidity (RH) range of (20-80)%; thus, the humidity effect can be ignored with a dose uncertainty of 0.15%. This assumption is based on the previous experimental results by Niate...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13665
更新日期:2019-09-01 00:00:00
abstract:PURPOSE:To investigate energy deposition in glandular tissues of the breast on macro- and microscopic length scales in the context of mammography. METHODS:Multiscale mammography models of breasts are developed, which include segmented, voxelized macroscopic tissue structure as well as nine regions of interest (ROIs) e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13372
更新日期:2019-03-01 00:00:00
abstract:PURPOSE:In this study, the authors validated a novel respiratory tracking device, the multidimensional respiratory tracking (MDRT) system, that was designed to assist in correcting for respiratory motion in PET/CT images. The authors also investigated a novel PET acquisition technique, smart gating (SG), that enables t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3523100
更新日期:2011-01-01 00:00:00
abstract::In order to investigate the relationship between diagnostic accuracy and radiographic image quality, we have developed a dual-film cassette which produces two radiographs simultaneously with a single exposure. One of these radiographs is of standard quality; the second is of lower quality because of degraded spatial r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595546
更新日期:1984-09-01 00:00:00
abstract::We have studied the effect of real-time optical image processing (OIP) in an image intensifier/television (II-TV) radiographic imaging system by using a liquid-crystal display (LCD) placed between the II and the TV camera. The LCD compresses the dynamic range of the transmitted image by modulating the spatial distribu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596199
更新日期:1988-11-01 00:00:00
abstract:PURPOSE:The purpose of this study was to describe and evaluate methods for calculating a megavoltage computed tomography (MVCT)-derived MR hardware attenuation map (μ-map) and dual-energy CT (DECT) for 511 keV photons. METHODS:Phantom measurements were acquired on a whole-body hybrid PET/MRI system, using a four-chann...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12407
更新日期:2017-09-01 00:00:00
abstract:PURPOSE:The purpose of this study was to quantitatively characterize the fundamental aspects of image quality (IQ) associated with different computed tomography (CT) reconstruction algorithms, the resolution, noise texture, noise magnitude per dose, and use those data to devise a methodology to match IQ between differe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12554
更新日期:2017-11-01 00:00:00
abstract::An integrating solid-state dosimeter has been developed to detect ultraviolet radiation using the process of "direct" ultraviolet stimulation. This process yields a thermoluminescent signal after an exposure to ultraviolet radiation, without prior exposure to ionizing radiation. Magnesium oxide crystals were found to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594259
更新日期:1976-11-01 00:00:00
abstract::Recently, portal imaging systems have been successfully demonstrated in dosimetric treatment verification applications, where measured and predicted images are quantitatively compared. To advance this approach to dosimetric verification, a two-step model which predicts dose deposition in arbitrary portal image detecto...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1289375
更新日期:2000-09-01 00:00:00
abstract:PURPOSE:Experimental dosimetry of high-dose-rate (HDR) 192 Ir brachytherapy (BT) sources is complicated due to high dose and dose-rate gradients, and softening of photon energy spectrum with depth. A single crystal synthetic diamond detector microDiamond (PTW 60019, Freiburg, Germany) has a small active volume, high se...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12694
更新日期:2018-01-01 00:00:00
abstract:PURPOSE:To show that Cherenkov emission is generated by external radiotherapy beam in tissue, and could serve as optical source to excite an oxygen sensitive phosphor, Oxyphor G4, within tissue. The intensity and lifetime of the phosphorescence was measured with a time-gated system and reveals the oxygenation levels in...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734811
更新日期:2012-06-01 00:00:00
abstract::The design and construction of a Styrofoam cutter used in the fabrication of custom shielding blocks is described. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594206
更新日期:1975-11-01 00:00:00
abstract::The Los Alamos code MCNP4A (Monte Carlo N-Particle version 4A) is currently used to simulate a variety of problems ranging from nuclear reactor analysis to boron neutron capture therapy. A graphical user interface has been developed that automatically sets up the MCNP4A geometry and radiation source requirements for a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598167
更新日期:1998-01-01 00:00:00
abstract::Depth dose distributions for a d(14)Be neutron beam, measured separately for total and gamma absorbed dose, are presented for nine tissue substitutes and for two field sizes. These data are used to examine methods to transform depth dose curves from one material to another. Best results are found when the local depths...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595695
更新日期:1985-05-01 00:00:00
abstract:PURPOSE:RapidArc is routinely used for stereotactic radiotherapy for lung cancer. While treatment dose is optimized and calculated on a static CT image, the motion of the target in conjunction with the motion of the MLC may Result in a delivered dose deviating from the planed dose. In this study, we investigate the dos...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734660
更新日期:2012-06-01 00:00:00
abstract::The availability of digital radiographic imaging on simulators has led to the investigation of a number of new imaging possibilities, including digital linear tomography (tomosynthesis). It has been shown that a single set of projections in this case is sufficient to reconstruct images from multiple planes, including ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598006
更新日期:1997-06-01 00:00:00
abstract:PURPOSE:We investigated the feasibility of using simpler methods than manual whole-organ volume-of-interest (VOI) definition to estimate the organ activity concentration in single photon emission computed tomography (SPECT) in cases where the activity in the organ can be assumed to be uniformly distributed on the scale...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12164
更新日期:2017-05-01 00:00:00
abstract:PURPOSE:Pulmonary magnetic-resonance-imaging (MRI) and x-ray computed-tomography have provided strong evidence of spatially and temporally persistent lung structure-function abnormalities in asthmatics. This has generated a shift in their understanding of lung disease and supports the use of imaging biomarkers as inter...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4948999
更新日期:2016-06-01 00:00:00
abstract::Using superior localization and immobilization methods, stereotactic radiosurgery is capable of delivering spheres of dose as small as a few millimetres in diameter to intracranial targets. For targets abutting critical structures, the most conformal treatments minimize adverse radiation side effects and it is importa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965910
更新日期:2008-07-01 00:00:00
abstract::The measurement of the radioactivity administered to the patient is one of the major components of 90Y microsphere liver brachytherapy. The activity of 90Y microspheres in a glass delivery vial was measured in a dose calibrator. The calibration value to use for 90Y in the dose calibrator was verified using an activity...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2731034
更新日期:2007-06-01 00:00:00
abstract::The purpose of this study was to quantify in-stent restenoses with 3D B mode and power Doppler ultrasound (U.S.) imaging. In-stent restenoses were mimicked with vascular phantoms in which a nonferromagnetic prototype stent (Boston Scientific) and a ferromagnetic clinical stainless steel stent (Palmaz P295) were embedd...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3062944
更新日期:2009-02-01 00:00:00
abstract::A 4-W, laser-based system for the positional readout of thermoluminescent (TL) plates was utilized to obtain dose profiles for a 60Co radiotherapy beam. Experimentally obtained glow curves for LiF resulting from the rapid heating rates characteristic of laser heating agreed well with results predicted using a first-or...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596580
更新日期:1990-05-01 00:00:00
abstract::The variance in the number of x-ray photons absorbed by a detector is derived from theoretical considerations. The distributions in the number of x-ray photons produced by the x-ray tube, transmitted through the patient, and absorbed by the detector are described. These distributions are compounded to yield a distribu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595393
更新日期:1983-07-01 00:00:00
abstract:PURPOSE:The ability to monitor intrafractional tumor motion is essential for radiation therapy of thoracic and abdominal tumors. This study aims to develop a method to track lung tumor motion using intrafractional continuous ultrasound (US) and periodic cone-beam projection images (CBPI). METHODS:Time-sequenced b-mode...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13104
更新日期:2018-10-01 00:00:00
abstract::Radiation therapy treatment modalities continue to develop and have become increasingly complex. With this, dose verification and quality assurance (QA) is of great importance to ensure that a prescribed dose is accurately and precisely delivered to a patient. Radiochromic film dosimetry has been adopted as a convenie...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740126
更新日期:2012-07-01 00:00:00
abstract::Based on direction from AAM Board of Directors, JMPLSC has redefined its scope and name. On November 4, 2011 the subcommittee renamed itself the Medical Physics Licensure and Regulatory Recognition Subcommittee. Its newly defined charge is to promote the protection of the public through the recognition of the professi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735947
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Discuss optimised Accelerated Partial Breast Irradiation (APBI) using a Strut-Adjused Volume Implant (SAVI) applicator for patients with implanted pacemeker, without overdosing or relocating the pacemaker. METHODS:A right breast cancer patient with an in situ pacemaker (Medtronic model ADDR01) on the right sid...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735299
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To investigate whether functionally-weighted dose-volume histogram (DVH) parameters are more predictive of radiation-induced pneumonitis (RP) than standard parameters such as V20 and mean lung dose (MLD). MATERIALS AND METHODS:A retrospective chart review identified 26 patients who received curative-intent rad...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740190
更新日期:2012-07-01 00:00:00