Abstract:
PURPOSE:In the practice code of dosimetry, humidity effect is assumed to be constant as far as the measurements are performed in the relative humidity (RH) range of (20-80)%; thus, the humidity effect can be ignored with a dose uncertainty of 0.15%. This assumption is based on the previous experimental results by Niatel and Guiho. Rogers and Ross calculated the stopping power ratio of humid air and dry air for high-energy electron beams by using a Monte Carlo code. They demonstrate that the W value, the mean energy required to create an ion pair in air, is independent of the beam quality when the air is dry, and that the traditional humidity correction can be used also for high-energy photon and electron beams; however, this was only a computational study. In the present study, we measured the humidity correction of Farmer-type ionization chambers in high-energy photon beams and determined the W values of humid air using the calculated energy deposition of humid air with a Monte Carlo code. Furthermore, we proposed an analytical expression to determine a practical humidity correction for an ionization chamber as a function of absolute humidity. METHOD:Experiments were carried out using a clinical linear accelerator (linac, Elekta Precise) at the National Metrology Institute of Japan (NMIJ). A shield box was constructed downstream of the linac and connected to an air processor, which maintained the temperature around 22°C and controlled the humidity in the range of (10-70)% inside the box. We prepared two Farmer-type ionization chambers: PTW 30013 and Exradin A19. Each ionization chamber was placed inside the box and irradiated with 6-, 10-, and 15-MV high-energy photon beams from the clinical linac. The energy deposition to the humid air inside the ionization chamber was calculated using the Electron Gamma Shower Version 5 (EGS5) code system. RESULTS:Stabilization for the humidity of the ionization chamber was completed within 3 h. The polarity and ion recombination corrections did not show any change in the humidity range studied. The measured humidity correction and the evaluated W values of humid air in high-energy photon beams were in good agreement with those by Rogers in TG-21 and by Niatel in the range of RH (10-70)%. CONCLUSION:Humidity correction of ionization chambers in high-energy photon beams from the clinical linac was determined experimentally. Using the analytical expression for the energy depositions by EGS5, the analytical expression for the W values was also derived.
journal_name
Med Physjournal_title
Medical physicsauthors
Sato Y,Shimizu M,Morishita Y,Sato M,Hoshina Mdoi
10.1002/mp.13665subject
Has Abstractpub_date
2019-09-01 00:00:00pages
4177-4183issue
9eissn
0094-2405issn
2473-4209journal_volume
46pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Using superior localization and immobilization methods, stereotactic radiosurgery is capable of delivering spheres of dose as small as a few millimetres in diameter to intracranial targets. For targets abutting critical structures, the most conformal treatments minimize adverse radiation side effects and it is importa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965910
更新日期:2008-07-01 00:00:00
abstract::Francis Bacon, who with Rene Decartes laid the intellectual foundations for Western science in the seventeenth century, asserted that the purpose of all knowledge is "action in the production of works for ... the relief of man's estate." We assess briefly several aspects of a few of the current efforts directed to the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1555493
更新日期:2003-04-01 00:00:00
abstract:PURPOSE:A three-dimensional finite element analysis based canine heart model is introduced that would enable the assessment of cardiac function. METHODS:The three-dimensional canine heart model is based on the cardiac deformation and motion model obtained from the Cardiac Mechanics Research Group at UCSD. The canine h...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3496326
更新日期:2010-11-01 00:00:00
abstract:PURPOSE:This work introduces a rigid registration framework for patient positioning in radiotherapy, based on real-time surface acquisition by a time-of-flight (ToF) camera. Dynamic properties of the system are also investigated for future gating/tracking strategies. METHODS:A novel preregistration algorithm, based on...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3664006
更新日期:2012-01-01 00:00:00
abstract:PURPOSE:To use the Monte Carlo code PENELOPE to study attenuation and tissue equivalence properties of a-Al2O3:C for OSL dosimetry. METHODS:Mass attenuation coefficients of α-Al2O3 and α-Al2O3:C with carbon percent weight concentrations from 1% to 150% were simulated with PENELOPE Monte Carlo code and compared to mass...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735237
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Radiotherapy, especially with charged particles, is sensitive to executional and preparational uncertainties that propagate to uncertainty in dose and plan quality indicators, for example, dose-volume histograms (DVHs). Current approaches to quantify and mitigate such uncertainties rely on explicitly computed e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14414
更新日期:2020-10-01 00:00:00
abstract::Modulation of the activity of the subthalamic nucleus (STN) using deep brain stimulation (DBS) in patients with advanced Parkinson's disease is the most common procedure performed today by functional neurosurgeons. The STN contours cannot be entirely identified on common 1.5 T images; in particular, the ventromedial b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2936229
更新日期:2008-07-01 00:00:00
abstract:PURPOSE:We report on the development of the open-source cross-platform radiation treatment planning toolkit matRad and its comparison against validated treatment planning systems. The toolkit enables three-dimensional intensity-modulated radiation therapy treatment planning for photons, scanned protons and scanned carb...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12251
更新日期:2017-06-01 00:00:00
abstract:PURPOSE:Positron emission tomography (PET) is considered the gold standard for measuring myocardial blood flow in vivo but it is known that respiratory motion can lead to misalignment of the PET and computed tomography (CT) data sets and introduce artifacts in the CT-based attenuation correction (AC) of images. In addi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4788669
更新日期:2013-02-01 00:00:00
abstract::The purpose of this study is to understand the effect of pitch on raw data interpolation in multislice spiral/helical computed tomography (CT) and provide guidelines for scanner design and protocol optimization. Multislice spiral CT is mainly characterized by the three parameters: the number of detector arrays, the de...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598804
更新日期:1999-12-01 00:00:00
abstract::Deformable registration is needed for a variety of tasks in establishing the voxel correspondence between respiratory phases. Most registration algorithms assume or imply that the deformation field is smooth and continuous everywhere. However, the lungs are contained within closed invaginated sacs called pleurae and a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2828378
更新日期:2008-02-01 00:00:00
abstract::In nuclear magnetic resonance (NMR) imaging by the zeugmatographic methods, there is a common and unified theoretical description. All forms of two-dimensional and three-dimensional imaging involve NMR data which trace various geometric representations, in reciprocal transform space, of the subject's spatially blurred...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595470
更新日期:1984-01-01 00:00:00
abstract:PURPOSE:To compare and evaluate intensity-based registration methods for computation of serial x-ray mammogram correspondence. METHODS:X-ray mammograms were simulated from MRIs of 20 women using finite element methods for modeling breast compressions and employing a MRI/x-ray appearance change model. The parameter con...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3457470
更新日期:2010-09-01 00:00:00
abstract::An automated technique has been developed for the verification of treatment field size and shape in external beam radiation therapy. Portal images from film or digital on-line imaging system are analyzed, and basic parameters are derived to describe the field size and shape from the contour points on the field boundar...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597017
更新日期:1993-05-01 00:00:00
abstract::During our routine calibration of a Varian Clinac-20 linear accelerator, the absorbed dose for a fixed monitor unit (mu) was found to decrease with increasing dose rate. Between dose rates of 100 and 500 mu/min, there was up to 20% difference in absorbed dose for a 20-MeV electron beam. The cause of this problem was a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596192
更新日期:1988-09-01 00:00:00
abstract:PURPOSE:Automated 3D breast ultrasound (ABUS) has gained interest in breast imaging. Especially for screening women with dense breasts, ABUS appears to be beneficial. However, since the amount of data generated is large, the risk of oversight errors is substantial. Computer aided detection (CADe) may be used as a secon...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4914162
更新日期:2015-04-01 00:00:00
abstract:PURPOSE:In the past decade, phase-contrast imaging (PCI) has been applied to study different kinds of tissues and human body parts, with an increased improvement of the image quality with respect to simple absorption radiography. A technique closely related to PCI is phase-retrieval imaging (PRI). Indeed, PCI is an ima...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3447727
更新日期:2010-07-01 00:00:00
abstract:PURPOSE:To determine the accuracy of VMAT treatment planning and delivery for patients undergoing radiotherapy in the head and neck. METHOD AND MATERIALS:A dosimetric study of a typical head and neck treatment plan has been carried out using Chamber, film and TLD's placed inside an anthropomorphic phantom. Lateral and...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735478
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The primary objective of this work is to measure the secondary neutron field produced by an uncollimated proton pencil beam impinging on different tissue-equivalent phantom materials using organic scintillation detectors. Additionally, the Monte Carlo code mcnpx-PoliMi was used to simulate the detector response...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4963813
更新日期:2016-11-01 00:00:00
abstract:PURPOSE:The aim of this work is to investigate the predictive power of a common conventional intensity modulated radiation therapy (IMRT) quality assurance (QA) performance metric, the gamma passing rate (%GP), through the analysis of the sensitivity and of the correlation between %GP and different dose discrepancies b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4767763
更新日期:2012-12-01 00:00:00
abstract:PURPOSE:Osteoporosis is a common bone disease associated with increased risk of low-trauma fractures leading to substantial morbidity, mortality, and financial costs. Clinically, osteoporosis is defined by low bone mineral density (BMD); however, increasing evidence suggests that trabecular bone (TB) microarchitectural...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4928481
更新日期:2015-09-01 00:00:00
abstract::Stereotactic Body Radiation Therapy (SBRT) is an important form of cancer therapy with increasingly broad application across a spectrum of tumor types in primary and metastatic settings. In this presentation the radiation biology, clinical experience from various trials, and cautionary updates on normal tissue toleran...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735812
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To study and compare the dose response curves of the new GafChromic EBT3 film for megavoltage and kilovoltage x-ray beams, with different spatial resolution. METHODS:Two sets of EBT3 films (lot#A101711-02) were exposed to each x-ray beam (6MV, 15MV and 50kV) at 8 dose values (50-3200cGy). The megavoltage beams...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735153
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The determination of absorbed dose to water from external beam radiotherapy using radiation detectors is currently rooted in calibration protocols that do not account for modulations encountered in patient-specific deliveries. Detector response in composite clinical fields has not been extensively studied due t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13293
更新日期:2019-02-01 00:00:00
abstract:PURPOSE:State of the art to access radiofrequency (RF) heating near implants is computer modeling of the devices and solving Maxwell's equations for the specific setup. For a set of input parameters, a fixed result is obtained. This work presents a theoretical approach in the alternating current (ac) limit, which can p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3637495
更新日期:2011-10-01 00:00:00
abstract:PURPOSE:Prostate biopsy, performed using two-dimensional (2D) transrectal ultrasound (TRUS) guidance, is the clinical standard for a definitive diagnosis of prostate cancer. Histological analysis of the biopsies can reveal cancerous, noncancerous, or suspicious, possibly precancerous, tissue. During subsequent biopsy s...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3298010
更新日期:2010-02-01 00:00:00
abstract::The purpose of this study is to incorporate the dosimetric effect of random patient positioning uncertainties directly into a commercial treatment planning system's IMRT plan optimization algorithm through probabilistic treatment planning (PTP) and compare coverage of this method with margin-based planning. In this wo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3176940
更新日期:2009-09-01 00:00:00
abstract:PURPOSE:Dedicated breast PET/CT is expected to have utility in local staging, surgical planning, monitoring of therapy response, and detection of residual disease for breast cancer. Quantitative metrics will be integral to several such applications. The authors present a validation of fully 3D data correction schemes f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3703593
更新日期:2012-05-01 00:00:00
abstract::We have recently installed a linear accelerator, modified to allow computer control of several machine parameters during irradiation of the patient. As an initial feasibility study of computer-controlled radiation therapy, its application to produce wedge-shaped dose distributions by moving the collimator jaws has bee...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594440
更新日期:1978-09-01 00:00:00
abstract:PURPOSE:In this work, the authors introduce a novel framework, the anatomically constrained registration (AnCoR) scheme and apply it to create a fused anatomic-disease atlas of the prostate which the authors refer to as the prostatome. The prostatome combines a MRI based anatomic and a histology based disease atlas. St...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4881515
更新日期:2014-07-01 00:00:00