Feasibility of real-time lung tumor motion monitoring using intrafractional ultrasound and kV cone beam projection images.

Abstract:

PURPOSE:The ability to monitor intrafractional tumor motion is essential for radiation therapy of thoracic and abdominal tumors. This study aims to develop a method to track lung tumor motion using intrafractional continuous ultrasound (US) and periodic cone-beam projection images (CBPI). METHODS:Time-sequenced b-mode US and CBPI data were extracted from the data acquired with the Clarity® and XVI platforms on an Elekta linac, respectively. The data were synchronized through a video capture card (VCE-PRO, IMPERX Inc.) which was triggered by the XVI system. In this way, a system was configured to allow real-time acquisition of the diaphragm position synchronized with periodic acquisition of the lung tumor position. Feasibility of the system was demonstrated by acquiring synchronized data on an in-house motion platform with embedded spheres of different materials and US images of the diaphragm on 5 volunteers of various body sizes. Finally, ultrasound b-mode images and CBPI were also acquired simultaneously from 3 lung cancer patients. RESULTS:Diaphragm motion monitoring under free breathing (FB) was successful with intracostal US imaging. We observed that diaphragm visualization decreased with the increase in the body size of the volunteer. The US system was able to track the motion as small as 2 mm in the phantom. The intrafractional CBPI acquired during VMAT delivery was successfully synchronized with US acquisition in a phantom study. Collected patient data showed a significant correlation between diaphragm motion, an internal surrogate monitored by US, and the tumor motion in superior-inferior (SI) direction monitored by XVI (P ˂ 0.0001). CONCLUSIONS:The feasibility of real-time lung tumor motion tracking in SI direction with continuous ultrasound and periodic CBPI was demonstrated. The real-time estimation of the target position from the two streams for lung cancer patients would enable respiration gating or tracking during SBRT.

journal_name

Med Phys

journal_title

Medical physics

authors

Mostafaei F,Tai A,Gore E,Johnstone C,Haase W,Ehlers C,Cooper DT,Lachaine M,Li XA

doi

10.1002/mp.13104

subject

Has Abstract

pub_date

2018-10-01 00:00:00

pages

4619-4626

issue

10

eissn

0094-2405

issn

2473-4209

journal_volume

45

pub_type

杂志文章
  • SU-E-I-57: CT Dose Metrics: What Are We Tracking.

    abstract:PURPOSE:Recent guidance by The Joint Commission and CRCPD recommendations require establishing CT reference dose levels (RDLs) for clinical protocols and recording CT dose metrics in the patient's medical record. This presentation addresses which dose values in the CT report should be recorded for the purposes of monit...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734773

    authors: Guild J,Arbique G,Blackburn T,Gallet J,Anderson J

    更新日期:2012-06-01 00:00:00

  • The NMR blood flowmeter--applications.

    abstract::Nuclear Magnetic Resonance (NMR) permits the noninvasive measurement of blood flow signals unimpaired by clothes, bandages, casts, etc. The cylindrical crossed-coil NMR blood flowmeter was used to measure blood flow through a cross-section of the human forearm. Two calibration procedures are described: one for pulsati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594989

    authors: Salles-Cunha SX,Halbach RE,Battocletti JH,Sances A Jr

    更新日期:1981-07-01 00:00:00

  • Vision 20/20: Molecular-guided surgical oncology based upon tumor metabolism or immunologic phenotype: Technological pathways for point of care imaging and intervention.

    abstract::Surgical guidance with fluorescence has been demonstrated in individual clinical trials for decades, but the scientific and commercial conditions exist today for a dramatic increase in clinical value. In the past decade, increased use of indocyanine green based visualization of vascular flow, biliary function, and tis...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4951732

    authors: Pogue BW,Paulsen KD,Samkoe KS,Elliott JT,Hasan T,Strong TV,Draney DR,Feldwisch J

    更新日期:2016-06-01 00:00:00

  • Effects of tumor motion in GRID therapy.

    abstract::Clinical and biological evidence suggest that the success of GRID therapy in debulking large tumors depends on the high peak-to-valley contrast in the dose distribution. In this study, we show that the peaks and valleys can be significantly blurred out by respiration-induced tumor motion, possibly affecting the clinic...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2977538

    authors: Naqvi SA,Mohiuddin MM,Ha JK,Regine WF

    更新日期:2008-10-01 00:00:00

  • Imaging of radiation dose by visible color development in ferrous-agarose-xylenol orange gels.

    abstract::Imaging of radiation dose distribution in gel phantoms by magnetic resonance techniques has previously been reported. In this paper a method of producing gels in which the distributions of radiation dose can also be visualized as a color change is reported. The color developed depends qualitatively and quantitatively ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596676

    authors: Appleby A,Leghrouz A

    更新日期:1991-03-01 00:00:00

  • Displacement-based binning of time-dependent computed tomography image data sets.

    abstract::Respiration can cause tumors in the thorax or abdomen to move by as much as 3 cm; this movement can adversely affect the planning and delivery of radiation treatment. Several techniques have been used to compensate for respiratory motion, but all have shortcomings. Manufacturers of computed tomography (CT) equipment h...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2044427

    authors: Fitzpatrick MJ,Starkschall G,Antolak JA,Fu J,Shukla H,Keall PJ,Klahr P,Mohan R

    更新日期:2006-01-01 00:00:00

  • Polarized x-ray excitation for scatter reduction in x-ray fluorescence computed tomography.

    abstract:PURPOSE:X-ray fluorescence computer tomography (XFCT) is a new molecular imaging modality which uses x-ray excitation to stimulate the emission of fluorescent photons in high atomic number contrast agents. Scatter contamination is one of the main challenges in XFCT imaging which limits the molecular sensitivity. When p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12997

    authors: Vernekohl D,Tzoumas S,Zhao W,Xing L

    更新日期:2018-05-25 00:00:00

  • Resolution modeling in PET imaging: theory, practice, benefits, and pitfalls.

    abstract::In this paper, the authors review the field of resolution modeling in positron emission tomography (PET) image reconstruction, also referred to as point-spread-function modeling. The review includes theoretical analysis of the resolution modeling framework as well as an overview of various approaches in the literature...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.4800806

    authors: Rahmim A,Qi J,Sossi V

    更新日期:2013-06-01 00:00:00

  • Reference dataset of users' photon beam modeling parameters for the Eclipse, Pinnacle, and RayStation treatment planning systems.

    abstract:PURPOSE:The aim of this work was to provide a novel description of how the radiotherapy community configures treatment planning system (TPS) radiation beam models for clinically used treatment machines. Here we describe the results of a survey of self-reported TPS beam modeling parameter values across different C-arm l...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13892

    authors: Glenn MC,Peterson CB,Followill DS,Howell RM,Pollard-Larkin JM,Kry SF

    更新日期:2020-01-01 00:00:00

  • Effect of longitudinal magnetic fields on a simulated in-line 6 MV linac.

    abstract:PURPOSE:Linac-magnetic resonance (MR) systems have been proposed in order to achieve realtime image guided radiotherapy. The design of a new linac-MR system with the in-line 6 MV linac generating x-rays along the symmetry axis of an open MR imager is outlined. This new design allows for a greater MR field strength to a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3481513

    authors: St Aubin J,Santos DM,Steciw S,Fallone BG

    更新日期:2010-09-01 00:00:00

  • Cascaded systems analysis of shift-variant image quality in slit-scanning breast tomosynthesis.

    abstract:PURPOSE:Digital breast tomosynthesis (DBT) is becoming an important part of breast cancer screening and diagnosis. Compared to two-dimensional mammography, tomosynthesis introduces limited three-dimensional (3D) resolution, but maintains high in-plane resolution, low dose, and allows for similar clinical protocols. The...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13116

    authors: Berggren K,Cederström B,Lundqvist M,Fredenberg E

    更新日期:2018-10-01 00:00:00

  • Classification of breast lesions using segmented quantitative ultrasound maps of homodyned K distribution parameters.

    abstract:PURPOSE:Statistical modeling of an ultrasound backscattered echo envelope is used for tissue characterization. However, in the presence of complex structures within the analyzed area, estimation of parameters is disturbed and unreliable, e.g., in the case of breast tumor classification. In order to improve the differen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4962928

    authors: Byra M,Nowicki A,Wróblewska-Piotrzkowska H,Dobruch-Sobczak K

    更新日期:2016-10-01 00:00:00

  • Dosimetric verification of helical tomotherapy for total scalp irradiation.

    abstract::Total scalp irradiation is a treatment technique used for a variety of superficial malignancies. Helical tomotherapy is an effective technique used for total scalp irradiation. Recent published work has shown the TomoTherapy planning system to overestimate the superficial dose. In this study, the superficial doses for...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2996288

    authors: Hardcastle N,Soisson E,Metcalfe P,Rosenfeld AB,Tome WA

    更新日期:2008-11-01 00:00:00

  • Optimization of power deposition and a heating strategy for external ultrasound thermal therapy.

    abstract::The purpose of this paper is to examine the thermal dose distribution, to configure the optimal absorbed power deposition, and to design an appropriate heating strategy for ultrasound thermal therapy. This work employs simulation programs, which are based on the transient bio-heat transfer equation and an ideal absorb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1406516

    authors: Lin WL,Liang TC,Yen JY,Liu HL,Chen YY

    更新日期:2001-10-01 00:00:00

  • Nonlocal atlas-guided multi-channel forest learning for human brain labeling.

    abstract:PURPOSE:It is important for many quantitative brain studies to label meaningful anatomical regions in MR brain images. However, due to high complexity of brain structures and ambiguous boundaries between different anatomical regions, the anatomical labeling of MR brain images is still quite a challenging task. In many ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4940399

    authors: Ma G,Gao Y,Wu G,Wu L,Shen D

    更新日期:2016-02-01 00:00:00

  • Upgrade and benchmarking of a 4D treatment planning system for scanned ion beam therapy.

    abstract:PURPOSE:Upgrade and benchmarking of a research 4D treatment planning system (4DTPS) suitable for realistic patient treatment planning and treatment simulations taking into account specific requirements for scanned ion beam therapy, i.e., modeling of dose heterogeneities due to interplay effects and range changes caused...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4800802

    authors: Richter D,Schwarzkopf A,Trautmann J,Krämer M,Durante M,Jäkel O,Bert C

    更新日期:2013-05-01 00:00:00

  • Correcting and reweighting false label masks in brain tumor segmentation.

    abstract:PURPOSE:Recently, brain tumor segmentation has made important progress. However, the quality of manual labels plays an important role in the performance, while in practice, it could vary greatly and in turn could substantially mislead the learning process and decrease the accuracy. We need to design a mechanism to comb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14480

    authors: Cheng G,Ji H,He L

    更新日期:2020-09-24 00:00:00

  • Comparison of proton and x-ray conformal dose distributions for radiosurgery applications.

    abstract::Highly focused dose distributions for radiosurgery applications are successfully achieved using either multiple static high-energy particle beams or multiple-arc circular x-ray beams from a linac. It has been suggested that conformal x-ray techniques using dynamically shaped beams with a moving radiation source would ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597654

    authors: Serago CF,Thornton AF,Urie MM,Chapman P,Verhey L,Rosenthal SJ,Gall KP,Niemierko A

    更新日期:1995-12-01 00:00:00

  • Best estimate of luminal cross-sectional area of coronary arteries from angiograms.

    abstract::We have reexamined the problem of estimating the luminal area of an elliptically shaped coronary artery cross section from two or more radiographic diameter measurements. The expected error is found to be much smaller than the maximum potential error. In the cases of two orthogonal views, closed form expressions have ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596296

    authors: Lee PL,Selzer RH

    更新日期:1988-07-01 00:00:00

  • Direct aperture optimization: a turnkey solution for step-and-shoot IMRT.

    abstract::IMRT treatment plans for step-and-shoot delivery have traditionally been produced through the optimization of intensity distributions (or maps) for each beam angle. The optimization step is followed by the application of a leaf-sequencing algorithm that translates each intensity map into a set of deliverable aperture ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1477415

    authors: Shepard DM,Earl MA,Li XA,Naqvi S,Yu C

    更新日期:2002-06-01 00:00:00

  • On the conditioning of basis materials and its impact on multi-material decomposition based spectral imaging in photon-counting CT.

    abstract:PURPOSE:Material-specific imaging and virtual monochromatic imaging/analysis are the two forms of spectral imaging in CT implemented via either energy-integration or photon-counting data acquisition. Aimed at further understanding the fundamentals and providing guidelines on its design and implementation, we quantitati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14708

    authors: Tang X,Ren Y

    更新日期:2021-01-07 00:00:00

  • Motion tracking of low-activity fiducial markers using adaptive region of interest with list-mode positron emission tomography.

    abstract:PURPOSE:Motion compensated positron emission tomography (PET) imaging requires detecting and monitoring of patient body motion. We developed a semiautomatic list-mode method to track the three-dimensional (3D) motion of fiducial positron-emitting markers during PET imaging. METHODS:A previously developed motion tracki...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14206

    authors: Chamberland MJP,deKemp RA,Xu T

    更新日期:2020-08-01 00:00:00

  • Electron dosimetry based on the absorbed dose to water concept: a comparison of the AAPM TG-51 and DIN 6800-2 protocols.

    abstract::The dosimetry protocols DIN 6800-2 and AAPM TG-51, both based on the absorbed dose to water concept, are compared in their theoretical background and in their application to electron dosimetry. The agreement and disagreement in correction factors and energy parameters used in both protocols will be shown and discussed...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1414008

    authors: Dohm OS,Christ G,Nüsslin F,Schüle E,Bruggmoser G

    更新日期:2001-11-01 00:00:00

  • A systematic Monte Carlo study of secondary electron fluence perturbation in clinical proton beams (70-250 MeV) for cylindrical and spherical ion chambers.

    abstract::Current dosimetry protocols for clinical protons do not take into account any secondary electron fluence perturbation in ion chambers. In this work, we performed a systematic study of secondary electron fluence perturbation factors for spherical and cylindrical ion chambers in proton beams (70-250 MeV). The electron f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1406519

    authors: Verhaegen F,Palmans H

    更新日期:2001-10-01 00:00:00

  • Technical note: Correlation of respiratory motion between external patient surface and internal anatomical landmarks.

    abstract:PURPOSE:Current respiratory motion monitoring devices used for motion synchronization in medical imaging and radiotherapy provide either 1D respiratory signal over a specific region or 3D information based on few external or internal markers. On the other hand, newer technology may offer the potential to monitor the en...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3589131

    authors: Fayad H,Pan T,Clement JF,Visvikis D

    更新日期:2011-06-01 00:00:00

  • Magnetic cell delivery for peripheral arterial disease: A theoretical framework.

    abstract:PURPOSE:Our aim was to compare different magnet arrangements for magnetic cell delivery to human lower leg arteries and investigate the theoretical targeting efficiency under realistic flow conditions as a possible treatment after angioplasty. Additionally the potential of scaling down or translating the magnetic actua...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3593363

    authors: Riegler J,Lau KD,Garcia-Prieto A,Price AN,Richards T,Pankhurst QA,Lythgoe MF

    更新日期:2011-07-01 00:00:00

  • Image segmentation with a novel regularized composite shape prior based on surrogate study.

    abstract:PURPOSE:Incorporating training into image segmentation is a good approach to achieve additional robustness. This work aims to develop an effective strategy to utilize shape prior knowledge, so that the segmentation label evolution can be driven toward the desired global optimum. METHODS:In the variational image segmen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4945046

    authors: Zhao T,Ruan D

    更新日期:2016-05-01 00:00:00

  • Measurements of the neutron yields from 7Li(p,n)7Be reaction (thick target) with incident energies from 1.885 to 2.0 MeV.

    abstract::Accelerator-based neutron source have been considered to be practical for boron neutron capture therapy (BNCT). Based on experience with a parameters of the Brookhaven National Laboratory BMRR reactor neutron source, which has been used in treatment experiments, the future accelerator-based neutron source for BNCT sho...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598299

    authors: Yu W,Yue G,Han X,Chen J,Tian B

    更新日期:1998-07-01 00:00:00

  • Improved modeling of multiple scattering in the Voxel Monte Carlo model.

    abstract::The implementation of an improved model for multiple scattering into the-Voxel Monte Carlo (VMC) algorithm for fast electron dose calculation in radiation therapy is presented. The model takes into account path-length corrections (PLC) and lateral displacement in the individual electron steps. The extraction of the sc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597933

    authors: Kawrakow I

    更新日期:1997-04-01 00:00:00

  • TU-E-213AB-01: JMPSLC Has Morphed into Medical Physics Licensure and Regulatory Recognition Subcommittee.

    abstract::Based on direction from AAM Board of Directors, JMPLSC has redefined its scope and name. On November 4, 2011 the subcommittee renamed itself the Medical Physics Licensure and Regulatory Recognition Subcommittee. Its newly defined charge is to promote the protection of the public through the recognition of the professi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735947

    authors: Pizzutiello R

    更新日期:2012-06-01 00:00:00