Nonlocal atlas-guided multi-channel forest learning for human brain labeling.

Abstract:

PURPOSE:It is important for many quantitative brain studies to label meaningful anatomical regions in MR brain images. However, due to high complexity of brain structures and ambiguous boundaries between different anatomical regions, the anatomical labeling of MR brain images is still quite a challenging task. In many existing label fusion methods, appearance information is widely used. However, since local anatomy in the human brain is often complex, the appearance information alone is limited in characterizing each image point, especially for identifying the same anatomical structure across different subjects. Recent progress in computer vision suggests that the context features can be very useful in identifying an object from a complex scene. In light of this, the authors propose a novel learning-based label fusion method by using both low-level appearance features (computed from the target image) and high-level context features (computed from warped atlases or tentative labeling maps of the target image). METHODS:In particular, the authors employ a multi-channel random forest to learn the nonlinear relationship between these hybrid features and target labels (i.e., corresponding to certain anatomical structures). Specifically, at each of the iterations, the random forest will output tentative labeling maps of the target image, from which the authors compute spatial label context features and then use in combination with original appearance features of the target image to refine the labeling. Moreover, to accommodate the high inter-subject variations, the authors further extend their learning-based label fusion to a multi-atlas scenario, i.e., they train a random forest for each atlas and then obtain the final labeling result according to the consensus of results from all atlases. RESULTS:The authors have comprehensively evaluated their method on both public LONI_LBPA40 and IXI datasets. To quantitatively evaluate the labeling accuracy, the authors use the dice similarity coefficient to measure the overlap degree. Their method achieves average overlaps of 82.56% on 54 regions of interest (ROIs) and 79.78% on 80 ROIs, respectively, which significantly outperform the baseline method (random forests), with the average overlaps of 72.48% on 54 ROIs and 72.09% on 80 ROIs, respectively. CONCLUSIONS:The proposed methods have achieved the highest labeling accuracy, compared to several state-of-the-art methods in the literature.

journal_name

Med Phys

journal_title

Medical physics

authors

Ma G,Gao Y,Wu G,Wu L,Shen D

doi

10.1118/1.4940399

subject

Has Abstract

pub_date

2016-02-01 00:00:00

pages

1003-19

issue

2

eissn

0094-2405

issn

2473-4209

journal_volume

43

pub_type

杂志文章
  • Actively triggered 4d cone-beam CT acquisition.

    abstract:PURPOSE:4d cone-beam computed tomography (CBCT) scans are usually reconstructed by extracting the motion information from the 2d projections or an external surrogate signal, and binning the individual projections into multiple respiratory phases. In this "after-the-fact" binning approach, however, projections are uneve...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4817479

    authors: Fast MF,Wisotzky E,Oelfke U,Nill S

    更新日期:2013-09-01 00:00:00

  • Selecting registration schemes in case of interstitial lung disease follow-up in CT.

    abstract:PURPOSE:Primary goal of this study is to select optimal registration schemes in the framework of interstitial lung disease (ILD) follow-up analysis in CT. METHODS:A set of 128 multiresolution schemes composed of multiresolution nonrigid and combinations of rigid and nonrigid registration schemes are evaluated, utilizi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4923170

    authors: Vlachopoulos G,Korfiatis P,Skiadopoulos S,Kazantzi A,Kalogeropoulou C,Pratikakis I,Costaridou L

    更新日期:2015-08-01 00:00:00

  • Cascade convolutional neural networks for automatic detection of thyroid nodules in ultrasound images.

    abstract:PURPOSE:It is very important for calculation of clinical indices and diagnosis to detect thyroid nodules from ultrasound images. However, this task is a challenge mainly due to heterogeneous thyroid nodules with distinct components are similar to background in ultrasound images. In this study, we employ cascade deep co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12134

    authors: Ma J,Wu F,Jiang T,Zhu J,Kong D

    更新日期:2017-05-01 00:00:00

  • Use of 48Ca as a stable isotope tracer analyzed by proton activation.

    abstract::The use of the stable isotope 48Ca as a tracer in biological systems has been studied. Determination of 48Ca concentrations in samples was accomplished by proton activation via the (p,n) reaction with subsequent measurement of gamma-ray spectra from 44-h 48Sc and 4-h 44Sc. With protons of about 5.5 MeV and a Ge(Li) ga...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594303

    authors: Edwards FM,Kraushaar JJ,Ristinen RA,Rudolph H

    更新日期:1977-01-01 00:00:00

  • Measured electron energy and angular distributions from clinical accelerators.

    abstract::Electron energy spectra and angular distributions, including angular spreads, were measured using magnetic spectrometer techniques, at isocenter, for two clinical linear accelerators: one scanning beam machine, which achieves field flatness by scanning a pencil beam over the desired field at the patient plane, and one...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597817

    authors: Deasy JO,Almond PR,McEllistrem MT

    更新日期:1996-05-01 00:00:00

  • Technical Note: Robust individual thermoluminescence dosimeter tracking using optical fingerprinting.

    abstract:PURPOSE:The thermoluminescence dosimeter (TLD) has desirable features including low cost, reusability, small size, and relatively low energy dependence. However, the commonly available poly-crystal TLDs (e.g., TLD-100) exhibit high interdetector variability that requires individual calibration for high detection accura...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13895

    authors: Shang D,Gu W,Landers A,Woods K,Yu V,Neph R,Tenn S,Sheng K

    更新日期:2020-01-01 00:00:00

  • A comparison of gantry-mounted x-ray-based real-time target tracking methods.

    abstract:PURPOSE:Most modern radiotherapy machines are built with a 2D kV imaging system. Combining this imaging system with a 2D-3D inference method would allow for a ready-made option for real-time 3D tumor tracking. This work investigates and compares the accuracy of four existing 2D-3D inference methods using both motion tr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12765

    authors: Montanaro T,Nguyen DT,Keall PJ,Booth J,Caillet V,Eade T,Haddad C,Shieh CC

    更新日期:2018-03-01 00:00:00

  • Rigid 2D/3D slice-to-volume registration and its application on fluoroscopic CT images.

    abstract::Registration of single slices from FluoroCT, CineMR, or interventional magnetic resonance imaging to three dimensional (3D) volumes is a special aspect of the two-dimensional (2D)/3D registration problem. Rather than digitally rendered radiographs (DRR), single 2D slice images obtained during interventional procedures...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2401661

    authors: Birkfellner W,Figl M,Kettenbach J,Hummel J,Homolka P,Schernthaner R,Nau T,Bergmann H

    更新日期:2007-01-01 00:00:00

  • State-of-the-art in two-dimensional ultrasonic transducer array technology.

    abstract::Attention is given to means of sensing ultrasonic energy distributions over an area. Under the restraints appropiate to real-time imaging of deep body organs, piezoelectric arrays offer the most promising method. Adaptation of integrated circuit techniques to array assembly permits very large arrays of small elements ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594247

    authors: Maginness MG,Plummer JD,Beaver WL,Meindl JD

    更新日期:1976-09-01 00:00:00

  • Simulated accuracy assessment of small footprint body-mounted probe alignment device for MRI-guided cryotherapy of abdominal lesions.

    abstract:PURPOSE:Magnetic resonance imaging (MRI)-guided percutaneous cryotherapy of abdominal lesions, an established procedure, uses MRI to guide and monitor the cryoablation of lesions. Methods to precisely guide cryotherapy probes with a minimum amount of trial-and-error are yet to be established. To aid physicians in attai...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14116

    authors: Shono N,Ninni B,King F,Kato T,Tokuda J,Fujimoto T,Tuncali K,Hata N

    更新日期:2020-06-01 00:00:00

  • The feasibility study and characterization of a two-dimensional diode array in "magic phantom" for high dose rate brachytherapy quality assurance.

    abstract:PURPOSE:High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly (192)Ir with an air KERMA strength range between 20,000 and 40,000 U, where 1 U = 1 μGy m(2)/h in a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4822736

    authors: Espinoza A,Beeksma B,Petasecca M,Fuduli I,Porumb C,Cutajar D,Corde S,Jackson M,Lerch ML,Rosenfeld AB

    更新日期:2013-11-01 00:00:00

  • Radiation dose reduction using a CdZnTe-based computed tomography system: comparison to flat-panel detectors.

    abstract:PURPOSE:Although x-ray projection mammography has been very effective in early detection of breast cancer, its utility is reduced in the detection of small lesions that are occult or in dense breasts. One drawback is that the inherent superposition of parenchymal structures makes visualization of small lesions difficul...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3312435

    authors: Le Huy Q,Ducote JL,Molloi S

    更新日期:2010-03-01 00:00:00

  • Sci-Fri AM: Imaging - 05: Cone-beam computed tomography for breast biopsy analysis: Simulations.

    abstract:PURPOSE:To determine the feasibility and potential utility of cone beam CT on breast biopsies. METHODS:CBCT simulations were done with a setup which emulates an MX-20 digital specimen radiography system (Faxitron X-Ray Corporation, Chicago, IL), albeit a DQE = 1 was assumed. The phantom consisted of a 5mm diameter cyl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740191

    authors: Laamanen C,LeClair R

    更新日期:2012-07-01 00:00:00

  • Image segmentation with a novel regularized composite shape prior based on surrogate study.

    abstract:PURPOSE:Incorporating training into image segmentation is a good approach to achieve additional robustness. This work aims to develop an effective strategy to utilize shape prior knowledge, so that the segmentation label evolution can be driven toward the desired global optimum. METHODS:In the variational image segmen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4945046

    authors: Zhao T,Ruan D

    更新日期:2016-05-01 00:00:00

  • The role of water desorption on optical clearing of biotissue: studied with near infrared reflectance spectroscopy.

    abstract::In order to understand the role of water desorption, i.e., the opposite of water adsorption, in optical clearing of biological tissue created by the application of hyperosmotic agents, dynamics of water loss in fresh porcine muscle tissue administrated with glycerol or ethylene glycol was investigated with the near-in...

    journal_title:Medical physics

    pub_type:

    doi:10.1118/1.1576228

    authors: Xu X,Wang RK

    更新日期:2003-06-01 00:00:00

  • Validation of a method for in vivo 3D dose reconstruction for IMRT and VMAT treatments using on-treatment EPID images and a model-based forward-calculation algorithm.

    abstract:PURPOSE:Radiation treatments are trending toward delivering higher doses per fraction under stereotactic radiosurgery and hypofractionated treatment regimens. There is a need for accurate 3D in vivo patient dose verification using electronic portal imaging device (EPID) measurements. This work presents a model-based te...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4935199

    authors: Van Uytven E,Van Beek T,McCowan PM,Chytyk-Praznik K,Greer PB,McCurdy BM

    更新日期:2015-12-01 00:00:00

  • An investigation into the robustness of dynamically collimated proton therapy treatments.

    abstract:PURPOSE:To investigate the dosimetric robustness of dynamically collimated proton therapy (DCPT) treatment plans delivered using a dynamic collimation system (DCS) with respect to random uncertainties in beam spot and collimator position as well as systematic offsets in the DCS mounting alignment. This work also demons...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14208

    authors: Smith BR,Hyer DE,Culberson WS

    更新日期:2020-08-01 00:00:00

  • Limitations of two-dimensional treatment planning programs.

    abstract::Some limitations of conventional two-dimensional computer programs used to plan radiation therapy are presented. These include: a lack of involvement in defining the clinical problem; deficiencies in the algorithms for computing dose; failure to compute dose throughout the volume of interest; an inability to handle tr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595226

    authors: Goitein M

    更新日期:1982-07-01 00:00:00

  • Determination of the photon spectrum of a clinical accelerator.

    abstract::An experiment to determine the peak of the energy spectrum of the photon beam from a Toshiba LMR-15 medical linear accelerator is described. It is found that the flattening filters removed much of the bremsstrahlung spectrum below approximately 1 MeV, resulting in a photon spectrum which peaks around 1.2 MeV. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595582

    authors: Brownridge J,Samnick S,Stiles P,Tipton P,Veselka J,Yeh N

    更新日期:1984-11-01 00:00:00

  • Region-oriented CT image representation for reducing computing time of Monte Carlo simulations.

    abstract:PURPOSE:We propose a new method for efficient particle transportation in voxelized geometry for Monte Carlo simulations. We describe its use for calculating dose distribution in CT images for radiation therapy. MATERIAL AND METHODS:The proposed approach, based on an implicit volume representation named segmented volum...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2884854

    authors: Sarrut D,Guigues L

    更新日期:2008-04-01 00:00:00

  • Dosimetric properties of the new 125I BrachySeed model LS-1 source.

    abstract::The BrachySeed model LS-1 is one of the latest in a series of new brachytherapy 125I seeds that have recently become available commercially for interstitial implants. The dosimetric properties of the seed were investigated analytically, experimentally, and by Monte Carlo simulation. Following the AAPM Task Group 43 fo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1445411

    authors: Chan GH,Prestwich WV

    更新日期:2002-02-01 00:00:00

  • A statistical analysis of ionometrically measured 6-MV x-ray beam parameters.

    abstract::A statistical analysis has been made of ionometrically measured parameters related to the central-axis output, the beam symmetry, the beam flatness, and the depth dose for the 6-MV x-ray beam from the Therac-6 linear accelerator. The means and coefficients of variation of the measurements are determined on a monthly b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595642

    authors: Dawson DJ,Gribble MA

    更新日期:1984-09-01 00:00:00

  • A system for intensity modulated dose plan verification based on an experimental pencil beam kernel obtained by deconvolution.

    abstract::The number of intensity modulated radiation therapy (IMRT) procedures is continuously growing worldwide and it is necessary to develop tools for patient specific quality assurance (QA) that avoid using machine time that could be employed in treating additional patients. One way of achieving this goal is to perform a m...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2815359

    authors: Azcona JD,Burguete J

    更新日期:2008-01-01 00:00:00

  • Computer-aided detection of mammographic microcalcifications: pattern recognition with an artificial neural network.

    abstract::We are developing a computer program for automated detection of clustered microcalcifications on mammograms. In this study, we investigated the effectiveness of a signal classifier based on a convolution neural network (CNN) approach for improvement of the accuracy of the detection program. Fifty-two mammograms with c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597428

    authors: Chan HP,Lo SC,Sahiner B,Lam KL,Helvie MA

    更新日期:1995-10-01 00:00:00

  • The NMR blood flowmeter--applications.

    abstract::Nuclear Magnetic Resonance (NMR) permits the noninvasive measurement of blood flow signals unimpaired by clothes, bandages, casts, etc. The cylindrical crossed-coil NMR blood flowmeter was used to measure blood flow through a cross-section of the human forearm. Two calibration procedures are described: one for pulsati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594989

    authors: Salles-Cunha SX,Halbach RE,Battocletti JH,Sances A Jr

    更新日期:1981-07-01 00:00:00

  • Differentiation between diamagnetic and paramagnetic cerebral lesions based on magnetic susceptibility mapping.

    abstract:PURPOSE:Identification of calcifications and hemorrhages is essential for the etiological diagnosis of cerebral lesions. The purpose of this work was to develop a robust method for characterization of para- and diamagnetic intracerebral lesions based on clinical gradient-echo magnetic resonance phase data acquired at 1...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3481505

    authors: Schweser F,Deistung A,Lehr BW,Reichenbach JR

    更新日期:2010-10-01 00:00:00

  • The polarity effect for commercially available plane-parallel ionization chambers.

    abstract::The polarity effect was investigated for three different commercially available plane-parallel ionization chambers: the Memorial Pipe chamber, the Victoreen/Nuclear Associates model 30-329 chamber manufactured by PTW, Frieburg, and the Capintec PS-033 thin-window ionization chamber. The primary study was the polarity ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596072

    authors: Gerbi BJ,Khan FM

    更新日期:1987-03-01 00:00:00

  • Poster - Thur Eve - 59: Dosimetric evaluation on the variation of PTV coverage due to patient size reduction using the prostate dose-volume factor in prostate radiotherapy.

    abstract::We proposed to use the prostate dose-volume factor (PDVF), derived from the dose-volume dataset of planning target volume (PTV) in prostate radiotherapy to evaluate treatment plans of prostate volumetric modulated arc therapy (VMAT) and intensity modulated radiotherapy (IMRT). To demonstrate plan evaluation using PDVF...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740167

    authors: Chow J,Jiang R,Markel D

    更新日期:2012-07-01 00:00:00

  • Assessment of the spectral performance of hybrid photon counting x-ray detectors.

    abstract:PURPOSE:Hybrid Photon Counting (HPC) detectors profoundly improved x-ray diffraction experiments at third generation synchrotron facilities. Enabling the simultaneous measurement of x-ray intensities in multiple energy bins, they also have many potential applications in the field of medical imaging. A prerequisite for ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12323

    authors: Trueb P,Zambon P,Broennimann C

    更新日期:2017-09-01 00:00:00

  • Analysis of the significance of scattered radiation in reduced dose mammography, including magnification effects, scatter suppression, and focal spot and detector blurring.

    abstract::A systems analysis of reduced dose mammography with scatter removal has quantitatively specified the relationships between the several parameters in mammography systems. While the results are only preliminary in the sense that they need to be proven experimentally, they do seem to provide a good feel for the nature of...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594540

    authors: Muntz EP

    更新日期:1979-03-01 00:00:00