Selecting registration schemes in case of interstitial lung disease follow-up in CT.

Abstract:

PURPOSE:Primary goal of this study is to select optimal registration schemes in the framework of interstitial lung disease (ILD) follow-up analysis in CT. METHODS:A set of 128 multiresolution schemes composed of multiresolution nonrigid and combinations of rigid and nonrigid registration schemes are evaluated, utilizing ten artificially warped ILD follow-up volumes, originating from ten clinical volumetric CT scans of ILD affected patients, to select candidate optimal schemes. Specifically, all combinations of four transformation models (three rigid: rigid, similarity, affine and one nonrigid: third order B-spline), four cost functions (sum-of-square distances, normalized correlation coefficient, mutual information, and normalized mutual information), four gradient descent optimizers (standard, regular step, adaptive stochastic, and finite difference), and two types of pyramids (recursive and Gaussian-smoothing) were considered. The selection process involves two stages. The first stage involves identification of schemes with deformation field singularities, according to the determinant of the Jacobian matrix. In the second stage, evaluation methodology is based on distance between corresponding landmark points in both normal lung parenchyma (NLP) and ILD affected regions. Statistical analysis was performed in order to select near optimal registration schemes per evaluation metric. Performance of the candidate registration schemes was verified on a case sample of ten clinical follow-up CT scans to obtain the selected registration schemes. RESULTS:By considering near optimal schemes common to all ranking lists, 16 out of 128 registration schemes were initially selected. These schemes obtained submillimeter registration accuracies in terms of average distance errors 0.18 ± 0.01 mm for NLP and 0.20 ± 0.01 mm for ILD, in case of artificially generated follow-up data. Registration accuracy in terms of average distance error in clinical follow-up data was in the range of 1.985-2.156 mm and 1.966-2.234 mm, for NLP and ILD affected regions, respectively, excluding schemes with statistically significant lower performance (Wilcoxon signed-ranks test, p < 0.05), resulting in 13 finally selected registration schemes. CONCLUSIONS:Selected registration schemes in case of ILD CT follow-up analysis indicate the significance of adaptive stochastic gradient descent optimizer, as well as the importance of combined rigid and nonrigid schemes providing high accuracy and time efficiency. The selected optimal deformable registration schemes are equivalent in terms of their accuracy and thus compatible in terms of their clinical outcome.

journal_name

Med Phys

journal_title

Medical physics

authors

Vlachopoulos G,Korfiatis P,Skiadopoulos S,Kazantzi A,Kalogeropoulou C,Pratikakis I,Costaridou L

doi

10.1118/1.4923170

subject

Has Abstract

pub_date

2015-08-01 00:00:00

pages

4511-25

issue

8

eissn

0094-2405

issn

2473-4209

journal_volume

42

pub_type

杂志文章
  • Evaluation of carbon nanotube x-ray source array for stationary head computed tomography.

    abstract:PURPOSE:Stationary computed tomography (s-CT) conceptually offers several advantages over existing rotating gantry-based CT. Over the last 40 yr, s-CT has been investigated using different technological approaches. We are developing a s-CT system specifically for head/brain imaging using carbon nanotube (CNT)-based fie...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14696

    authors: Spronk D,Luo Y,Inscoe CR,Lee YZ,Lu J,Zhou O

    更新日期:2020-12-31 00:00:00

  • Measurement of neutron ambient dose equivalent in passive carbon-ion and proton radiotherapies.

    abstract::Secondary neutron ambient dose equivalents per the treatment absorbed dose in passive carbon-ion and proton radiotherapies were measured using a rem meter, WENDI-II at two carbon-ion radiotherapy facilities and four proton radiotherapy facilities in Japan. Our measured results showed that (1) neutron ambient dose equi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2989019

    authors: Yonai S,Matsufuji N,Kanai T,Matsui Y,Matsushita K,Yamashita H,Numano M,Sakae T,Terunuma T,Nishio T,Kohno R,Akagi T

    更新日期:2008-11-01 00:00:00

  • SU-E-I-94: External Beam Radiation Cherenkov Emission in Tissue Used for Tissue Oxygen Sensing.

    abstract:PURPOSE:To show that Cherenkov emission is generated by external radiotherapy beam in tissue, and could serve as optical source to excite an oxygen sensitive phosphor, Oxyphor G4, within tissue. The intensity and lifetime of the phosphorescence was measured with a time-gated system and reveals the oxygenation levels in...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734811

    authors: Zhang R,Kanick S,Vinogradov S,Esipova T,Pogue B

    更新日期:2012-06-01 00:00:00

  • Noise, sampling, and the number of projections in cone-beam CT with a flat-panel detector.

    abstract:PURPOSE:To investigate the effect of the number of projection views on image noise in cone-beam CT (CBCT) with a flat-panel detector. METHODS:This fairly fundamental consideration in CBCT system design and operation was addressed experimentally (using a phantom presenting a uniform medium as well as statistically moti...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4875688

    authors: Zhao Z,Gang GJ,Siewerdsen JH

    更新日期:2014-06-01 00:00:00

  • Definition of parameters for quality assurance of flattening filter free (FFF) photon beams in radiation therapy.

    abstract:PURPOSE:Flattening filter free (FFF) beams generated by medical linear accelerators have recently started to be used in radiotherapy clinical practice. Such beams present fundamental differences with respect to the standard filter flattened (FF) beams, making the generally used dosimetric parameters and definitions not...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4754799

    authors: Fogliata A,Garcia R,Knoos T,Nicolini G,Clivio A,Vanetti E,Khamphan C,Cozzi L

    更新日期:2012-10-01 00:00:00

  • Novel scintillation detector design and performance for proton radiography and computed tomography.

    abstract:PURPOSE:Proton computed tomography (pCT) will enable accurate prediction of proton and ion range in a patient while providing the benefit of lower radiation exposure than in x-ray CT. The accuracy of the range prediction is essential for treatment planning in proton or ion therapy and depends upon the detector used to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4939255

    authors: Bashkirov VA,Schulte RW,Hurley RF,Johnson RP,Sadrozinski HF,Zatserklyaniy A,Plautz T,Giacometti V

    更新日期:2016-02-01 00:00:00

  • Thick phosphor screens for on-line portal imaging.

    abstract::Gd2O2S phosphor screens between 250 and 1000 mg/cm2 thick were evaluated for use in megavoltage imaging systems. The phosphor layers were placed on brass plates ranging from 1 to 5 mm thick, each with and without an optical back reflector (white paint). Light output and spatial resolution were measured at 6- and 23-MV...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597209

    authors: Wowk B,Shalev S

    更新日期:1994-08-01 00:00:00

  • SU-E-J-41: Fluoroscopy Based Adaptive Setup Approach for Thoracic Cancer IGRT.

    abstract:PURPOSE:To develop a fluoroscopy imaging based approach that can determine the magnitude and phase variation in respiratory motion against the treatment planning images in order to quantify the online patient setup deviation in thoracic cancer IGRT for the real time adaptive patient positionadjustment. METHODS:A numer...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734876

    authors: Chen T,Qin S,Jabbour S,Park J,Haffty B,Yue N

    更新日期:2012-06-01 00:00:00

  • Computerized detection of lung nodules through radiomics.

    abstract:PURPOSE:Lung cancer is a major cause of cancer deaths, and the 5-year survival rate of stage IV lung cancer patients is only 2%. However, the 5-year survival rate of stage I lung cancer patients significantly increases to 50%. As such, spiral computed tomography (CT) scans are necessary to diagnose high-risk lung cance...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12331

    authors: Ma J,Zhou Z,Ren Y,Xiong J,Fu L,Wang Q,Zhao J

    更新日期:2017-08-01 00:00:00

  • Automatic needle segmentation in three-dimensional ultrasound images using two orthogonal two-dimensional image projections.

    abstract::In this paper, we describe an algorithm to segment a needle from a three-dimensional (3D) ultrasound image by using two orthogonal two-dimensional (2D) image projections. Not only is the needle more conspicuous in a projected (volume-rendered) image, but its direction in 3D lies in the plane defined by the projection ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1538231

    authors: Ding M,Cardinal HN,Fenster A

    更新日期:2003-02-01 00:00:00

  • Diamond detector versus silicon diode and ion chamber in photon beams of different energy and field size.

    abstract::The aim of this work was to test the suitability of a PTW diamond detector for nonreference condition dosimetry in photon beams of different energy (6 and 25 MV) and field size (from 2.6 cm x 2.6 cm to 10 cm x 10 cm). Diamond behavior was compared to that of a Scanditronix p-type silicon diode and a Scanditronix RK io...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1591431

    authors: Bucciolini M,Buonamici FB,Mazzocchi S,De Angelis C,Onori S,Cirrone GA

    更新日期:2003-08-01 00:00:00

  • Comparison of two methods for accurate measurement of modulation transfer functions of screen-film systems.

    abstract::The modulation transfer function (MTF) of a screen-film system can be measured by two methods, i.e., a slit method with Fourier transform on the line spread function and a square-wave response function (SWRF) method. However, it is still uncertain whether MTFs obtained by the two methods are identical. In this study, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597456

    authors: Morishita J,Doi K,Bollen R,Bunch PC,Hoeschen D,Sirand-rey G,Sukenobu Y

    更新日期:1995-02-01 00:00:00

  • Evaluation of a device for indirect assessment of automatic exposure control systems.

    abstract::A test device which can indirectly measure the performance of an automatic exposure control system and which offers the potential to reduce the time and film requirements for such tests has been evaluated. Evaluation results demonstrate that the device can successfully predict image optical density to within +/- 0.10 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597252

    authors: Rossi RP

    更新日期:1994-01-01 00:00:00

  • Tumor volume measurement errors of RECIST studied with ellipsoids.

    abstract:PURPOSE:The authors investigate the extent to which Response Evaluation Criteria in Solid Tumors (RECIST) can predict tumor volumes in ideal geometric settings and using clinical data. METHODS:The authors consider a hierarchy of models including uniaxial ellipsoids, general ellipsoids, and composites of ellipsoids, us...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3577602

    authors: Levine ZH,Galloway BR,Peskin AP,Heussel CP,Chen JJ

    更新日期:2011-05-01 00:00:00

  • The line spread function and modulation transfer function of a computed tomographic scanner.

    abstract::A simple method to measure the line spread function of computed tomographic scanners has been developed. The line spread function of the EMI-Scanner was measured and the MTF of the scanner was calculated. The reproducibility of the method indicated this technique could be utilized to compare the spatial resolution of ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594283

    authors: Judy PF

    更新日期:1976-07-01 00:00:00

  • Reference standard and statistical model for intersite and temporal comparisons of CT attenuation in a multicenter quantitative lung study.

    abstract:PURPOSE:The purpose of this study was to detect and analyze anomalies between a large number of computed tomography (CT) scanners, tracked over time, utilized to collect human pulmonary CT data for a national multicenter study: chronic obstructive pulmonary disease genetic epidemiology study (COPDGene). METHODS:A cust...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4747342

    authors: Sieren JP,Newell JD,Judy PF,Lynch DA,Chan KS,Guo J,Hoffman EA

    更新日期:2012-09-01 00:00:00

  • False-positive reduction in CAD mass detection using a competitive classification strategy.

    abstract::High false-positive (FP) rate remains to be one of the major problems to be solved in CAD study because too many false-positively cued signals will potentially degrade the performance of detecting true-positive regions and increase the call-back rate in CAD environment. In this paper, we proposed a novel classificatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1344203

    authors: Li L,Zheng Y,Zhang L,Clark RA

    更新日期:2001-02-01 00:00:00

  • Influence of 0.35 T magnetic field on the response of EBT3 and EBT-XD radiochromic films.

    abstract:PURPOSE:To investigate the inconsistency of recent literature on the effect of magnetic field on the response of radiochromic films, we studied the influence of 0.35 T magnetic field on dosimetric response of EBT3 and EBT-XD GafchromicTM films. METHODS:Two different models of radiochromic films, EBT3 and EBT-XD, were ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14313

    authors: Darafsheh A,Hao Y,Maraghechi B,Cammin J,Reynoso FJ,Khan R

    更新日期:2020-09-01 00:00:00

  • SU-E-T-462: Calculation of Prescribed Dose for Permanent Implant with Cs-131 Using LQ Equation including Resensitization.

    abstract:PURPOSE:To develop a new biological equivalent dose (BED) formulism that includes repair, repopulation and resensitization (redistribution and reoxygenation), and can be used to calculate prescribed dose for permanent implant with Cs-131. METHODS:Because of lack of sufficient clinical data, the prescribed dose with ne...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735551

    authors: Luo W,Aryal P,Randall M

    更新日期:2012-06-01 00:00:00

  • Phantoms with 10BF3 detectors for boron neutron capture therapy applications.

    abstract::Two acrylic cube phantoms have been constructed for BNCT applications that allow the depth distribution of neutrons to be measured with miniature 10BF3 detectors in 0.5-cm steps beginning at 1-cm depth. Sizes and weights of the cubes are 14 cm, 3.230 kg, and 11 cm, 1.567 kg. Tests were made with the epithermal neutron...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598354

    authors: Alburger DE,Raparia D,Zucker MS

    更新日期:1998-09-01 00:00:00

  • Computerized detection of masses in digital mammograms: analysis of bilateral subtraction images.

    abstract::A computerized scheme is being developed for the detection of masses in digital mammograms. Based on the deviation from the normal architectural symmetry of the right and left breasts, a bilateral subtraction technique is used to enhance the conspicuity of possible masses. The scheme employs two pairs of conventional ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596610

    authors: Yin FF,Giger ML,Doi K,Metz CE,Vyborny CJ,Schmidt RA

    更新日期:1991-09-01 00:00:00

  • Technical note: a fast laser-based optical-CT scanner for three-dimensional radiation dosimetry.

    abstract:PURPOSE:To introduce a novel laser-based optical-CT scanner for the readout of three-dimensional (3D) radiation dosimeters. METHODS:The scanner employs a diode laser, a cylindrical lens, a motorized linear rail, a rotation stage, and a charge-coupled device camera. The scanner operates in a translate-rotate fashion an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3538924

    authors: Papadakis AE,Maris TG,Zacharakis G,Papoutsaki V,Varveris C,Ripoll J,Damilakis J

    更新日期:2011-02-01 00:00:00

  • A quality management program in intravascular brachytherapy.

    abstract::While simple, intravascular brachytherapy (IVB) presents a considerable potential for harm to the patient. The medical physicist maintains the responsibility to minimize the likelihood of operational problems or dosimetric errors. The principals for safe operation remain the same as with any radiotherapy treatment: to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1524167

    authors: Chakri A,Thomadsen B

    更新日期:2002-12-01 00:00:00

  • A Monte Carlo estimation of effective dose in chest tomosynthesis.

    abstract:PURPOSE:The recent introduction of digital tomosynthesis imaging into routine clinical use has enabled the acquisition of volumetric patient data within a standard radiographic examination. Tomosynthesis requires the acquisition of multiple projection views, requiring additional dose compared to a standard projection e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3250907

    authors: Sabol JM

    更新日期:2009-12-01 00:00:00

  • Dosimetric effects of needle divergence in prostate seed implant using 125I and 103Pd radioactive seeds.

    abstract::In prostate seed implants, radioactive seeds are implanted into the prostate through a guiding needle with the help of a template and real-time imaging. The ideal locations of the guiding needles and the relative positions of the seeds in each needle are determined before the implantation under the assumption that the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598971

    authors: Nath S,Chen Z,Yue N,Trumpore S,Peschel R

    更新日期:2000-05-01 00:00:00

  • Radiative transport in the delta-P1 approximation for semi-infinite turbid media.

    abstract::We have developed an analytic solution for spatially resolved diffuse reflectance within the deltaP1 approximation to the radiative transport equation for a semi-infinite homogeneous turbid medium. We evaluate the performance of this solution by comparing its predictions with those provided by Monte Carlo simulations ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2828184

    authors: Seo I,Hayakawa CK,Venugopalan V

    更新日期:2008-02-01 00:00:00

  • A dosimetry study of the Oncoseed 6711 using glass rod dosimeters and EGS5 Monte Carlo code in a geometry lacking radiation equilibrium scatter conditions.

    abstract:PURPOSE:The aim of this study was to develop a dose calculation method which is applicable to the interseed attenuation and the geometry lacking the equilibrium radiation scatter conditions in brachytherapy. METHODS:The dose obtained from measurement with a radiophotoluminescent glass rod dosimeter (GRD) was compared ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3590370

    authors: Tanaka K,Tateoka K,Asanuma O,Kamo K,Bengua G,Sato K,Ueda T,Takeda H,Takagi M,Hareyama M,Takada J

    更新日期:2011-06-01 00:00:00

  • Unexpectedly large dose rate dependent output from a linear accelerator.

    abstract::During our routine calibration of a Varian Clinac-20 linear accelerator, the absorbed dose for a fixed monitor unit (mu) was found to decrease with increasing dose rate. Between dose rates of 100 and 500 mu/min, there was up to 20% difference in absorbed dose for a 20-MeV electron beam. The cause of this problem was a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596192

    authors: Cheng PC,Kubo H

    更新日期:1988-09-01 00:00:00

  • Dosimetry of a thyroid uptake detected in seed migration survey following a patient's iodine-125 prostate implant and in vitro measurements of intentional seed leakages.

    abstract::As a quality control procedure, a post-implant seed migration survey has been accomplished on 340 prostate cancer patients since November 2001. Pulmonary seed embolization and intracardiac seed embolization have been detected. A case of thyroid uptake due to leaking iodine-125 (I-125) sources was also seized. In order...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2207319

    authors: Chen QS,Russell JL Jr,Macklis RR,Weinhous MS,Blair HF

    更新日期:2006-07-01 00:00:00

  • Cascade convolutional neural networks for automatic detection of thyroid nodules in ultrasound images.

    abstract:PURPOSE:It is very important for calculation of clinical indices and diagnosis to detect thyroid nodules from ultrasound images. However, this task is a challenge mainly due to heterogeneous thyroid nodules with distinct components are similar to background in ultrasound images. In this study, we employ cascade deep co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12134

    authors: Ma J,Wu F,Jiang T,Zhu J,Kong D

    更新日期:2017-05-01 00:00:00