Abstract:
:During our routine calibration of a Varian Clinac-20 linear accelerator, the absorbed dose for a fixed monitor unit (mu) was found to decrease with increasing dose rate. Between dose rates of 100 and 500 mu/min, there was up to 20% difference in absorbed dose for a 20-MeV electron beam. The cause of this problem was a failure in the electronics circuit of an integrating board. This paper presents our analysis of the problem and suggests a possible means of isolating such a failure to warn technologists, physicists, and engineers.
journal_name
Med Physjournal_title
Medical physicsauthors
Cheng PC,Kubo Hdoi
10.1118/1.596192subject
Has Abstractpub_date
1988-09-01 00:00:00pages
766-7issue
5eissn
0094-2405issn
2473-4209journal_volume
15pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Liver segmentation is an important prerequisite for the assessment of liver cancer treatment options like tumor resection, image-guided radiation therapy (IGRT), radiofrequency ablation, etc. The purpose of this work was to evaluate a new approach for liver segmentation. METHODS:A graph cuts segmentation metho...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3682171
更新日期:2012-03-01 00:00:00
abstract:PURPOSE:To compare reconstructed volumes calculated via planimetry and frustum algorithms in the context of stepped transrectal ultrasound (US) imaging, and to estimate the reconstruction error for prostate volumes. METHODS:Prostate contours for 40 permanent implant patients were delineated on magnetic resonance (MR) ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4789920
更新日期:2013-03-01 00:00:00
abstract:PURPOSE:With the increased commercial availability of intensity modulated arc therapy (IMAT) comes the need for comprehensive QA programs, covering the different aspects of this newly available technology. This manuscript proposes such a program for the RapidArc (RA) (Varian Medical Systems, Palo Alto) IMAT solution. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3622672
更新日期:2011-09-01 00:00:00
abstract::During the past decade the use of undersampled acquisition and constrained reconstruction have led to significant increases in data acquisition speed, SNR, spatial resolution and temporal resolution in MR imaging. When a separately acquired constraining image is combined with an angiographic time series the traditiona...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735797
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Respiratory motion compensation in PET/CT and PET/MRI is essential as motion is a source of image degradation (motion blur, attenuation artifacts). In previous work, we developed a direct method for joint image reconstruction/motion estimation (JRM) for attenuation-corrected (AC) respiratory-gated PET, which us...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12253
更新日期:2017-06-01 00:00:00
abstract::The large variation of x-ray fluence at the detector in cone-beam CT (CBCT) poses a significant challenge to detectors' limited dynamic range, resulting in the loss of skinline as well as reduction of CT number accuracy, contrast-to-noise ratio, and image uniformity. The authors investigate the performance of a bowtie...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3017470
更新日期:2009-01-01 00:00:00
abstract:PURPOSE:Most radiation therapy optimization problems can be formulated as an unconstrained problem and solved efficiently by quasi-Newton methods such as the Limited-memory Broyden-Fletcher-Goldfarb-Shanno (L-BFGS) algorithm. However, several next generation planning techniques such as total variation regularization- b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12165
更新日期:2017-04-01 00:00:00
abstract::Contemporary reconstruction methods employed for clinical helical cone-beam computed tomography (CT) are analytical (noniterative) but mathematically nonexact, i.e., the reconstructed image contains so called cone-beam artifacts, especially for higher cone angles. Besides cone artifacts, these methods also suffer from...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2966353
更新日期:2008-09-01 00:00:00
abstract:PURPOSE:Current on-board imaging systems commonly used by modern linear accelerators (LINACs) have a limited field of view (FOV) for a cone-beam CT (CBCT) scan, which is typically less than 50 cm. Consequently, truncation artifacts often occur for large patients. The goal of this work is to investigate a novel method t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3514130
更新日期:2010-12-01 00:00:00
abstract:PURPOSE:The purpose of this study is to adapt an equivalent source model originally developed for conventional CT Monte Carlo dose quantification to the radiation oncology context and validate its application for evaluating concomitant dose incurred by a kilovoltage (kV) cone-beam CT (CBCT) system integrated into a lin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4823795
更新日期:2013-11-01 00:00:00
abstract:PURPOSE:To automatically detect and isolate areas of low and high stiffness temporal stability in shear wave elastography (SWE) image sequences and define their impact in chronic liver disease (CLD) diagnosis improvement by means of clinical examination study and deep learning algorithm employing convolutional neural n...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13521
更新日期:2019-05-01 00:00:00
abstract::Estimates of the effective dose to adult patients from computed tomography (CT) head scanning can be calculated using a number of different methods. These estimates can be used for a variety of purposes, such as improving scanning protocols, comparing different CT imaging centers, and weighing the benefits of the scan...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2952359
更新日期:2008-08-01 00:00:00
abstract:PURPOSE:To describe an efficient method for verifying the size and centering of the radiation field from the Cyberknife IRIS variable collimator with sub-millimeter accuracy using a general purpose commercially available diode array. METHODS:We present a technique using a conventional diode array (Sun Nuclear Profiler...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735220
更新日期:2012-06-01 00:00:00
abstract::Preclinical experiments are carried out with approximately 20-30 microm wide, approximately 10 mm high parallel microbeams of hard, broad-"white"-spectrum x rays (approximately 50-600 keV) to investigate microbeam radiation therapy (MRT) of brain tumors in infants for whom other kinds of radiotherapy are inadequate an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1562169
更新日期:2003-04-01 00:00:00
abstract::A method is described for calibration of 192Ir high-dose-rate (HDR) brachytherapy afterloading systems. Since NIST does not offer calibration of ionization chambers with the gamma-ray spectrum of iridium-192, an interpolation procedure is employed, using calibrations above (137Cs, 662 keV) and below (250 kVcp, 146-keV...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596649
更新日期:1991-05-01 00:00:00
abstract:PURPOSE:We report on the development of the open-source cross-platform radiation treatment planning toolkit matRad and its comparison against validated treatment planning systems. The toolkit enables three-dimensional intensity-modulated radiation therapy treatment planning for photons, scanned protons and scanned carb...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12251
更新日期:2017-06-01 00:00:00
abstract:PURPOSE:Identification of calcifications and hemorrhages is essential for the etiological diagnosis of cerebral lesions. The purpose of this work was to develop a robust method for characterization of para- and diamagnetic intracerebral lesions based on clinical gradient-echo magnetic resonance phase data acquired at 1...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3481505
更新日期:2010-10-01 00:00:00
abstract::It is shown that predictions can be made of scatter-to-primary ratios for a variety of mammographic configurations. The different configurations can be produced by changes in source-detector distance; source-phantom distance; air gap; photon energy; phantom composition, thickness, and cross-sectional area. A detailed ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595807
更新日期:1986-11-01 00:00:00
abstract:PURPOSE:This work concerns computed tomography (CT)-based cardiac functional analysis (CFA) with a reduced radiation dose. As CT-CFA requires images over the entire heartbeat, the scans are often performed at 10-20% of the tube current settings that are typically used for coronary CT angiography. A large image noise th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12425
更新日期:2017-09-01 00:00:00
abstract::An investigation was performed of the changes in image quality and patient dose as a result of increasing filtration for fluoroscopy performed under automatic brightness control. Filtration was added either at the x-ray tube housing (i.e., scatter-free geometry) or adjacent to a tissue equivalent phantom simulating th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597906
更新日期:1997-03-01 00:00:00
abstract:PURPOSE:Diffusion magnetic resonance imaging (MRI) in combination with functional MRI promises a whole new vista for scientists to investigate noninvasively the structural and functional connectivity of the human brain-the human connectome, which had heretofore been out of reach. As with other imaging modalities, diffu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3700166
更新日期:2012-05-01 00:00:00
abstract:PURPOSE:The overall goal of this work is to improve the computed tomography (CT) image quality for patients with metal implants or fillings by completing the missing kilovoltage (kV) projection data with selectively acquired megavoltage (MV) data that do not suffer from photon starvation. When both of these imaging sys...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4901551
更新日期:2014-12-01 00:00:00
abstract::Two side-by-side energy windows are sometimes employed in quantitative single photon emission computed tomography (SPECT) studies. The count-rate losses at high activities for a GE400AT camera were measured in such a dual-window-acquisition mode by imaging a decaying source composed of a hot sphere within a warm cylin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597008
更新日期:1993-07-01 00:00:00
abstract:PURPOSE:Credentialing can have an impact on whether or not a clinical trial produces useful quality data that is comparable between various institutions and scanners. With the recent increase of dynamic contrast enhanced-computed tomography (DCE-CT) usage as a companion biomarker in clinical trials, effective quality a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4812429
更新日期:2013-08-01 00:00:00
abstract::The polarity effect was investigated for three different commercially available plane-parallel ionization chambers: the Memorial Pipe chamber, the Victoreen/Nuclear Associates model 30-329 chamber manufactured by PTW, Frieburg, and the Capintec PS-033 thin-window ionization chamber. The primary study was the polarity ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596072
更新日期:1987-03-01 00:00:00
abstract:PURPOSE:Automated detection of solitary pulmonary nodules using positron emission tomography (PET) and computed tomography (CT) images shows good sensitivity; however, it is difficult to detect nodules in contact with normal organs, and additional efforts are needed so that the number of false positives (FPs) can be fu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4948498
更新日期:2016-06-01 00:00:00
abstract:PURPOSE:To develop a hypothesis-generating framework for automatic extraction of dose-outcome relationships from an in-house, analytic oncology database. METHODS:Dose-volume histograms (DVH) and clinical outcomes have been routinely stored to the authors' database for 684 head and neck cancer patients treated from 200...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4922686
更新日期:2015-07-01 00:00:00
abstract:PURPOSE:Colon cancer is a major public health problem due to its high disease rate and death toll worldwide. The use of FTIR microscopy in the field of cancer diagnosis has become attractive over the past 20 years. In the present study, the authors investigated the potential of FTIR microscopy to define spectral change...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3298013
更新日期:2010-03-01 00:00:00
abstract:PURPOSE:Transcranial focused ultrasound is an emerging therapeutic modality that can be used to perform noninvasive neurosurgical procedures. The current clinical transcranial phased array operates at 650 kHz, however the development of a higher frequency array would enable more precision, while reducing the risk of st...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4829510
更新日期:2013-12-01 00:00:00
abstract::This paper deals with methods of reducing the total time required to acquire the projection data for a set of contiguous computed tomography (CT) images. Normally during the acquisition of a set of slices, the patient is held stationary during data collection and translated to the next axial location during an intersc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596464
更新日期:1990-11-01 00:00:00