Development of a dynamic quality assurance testing protocol for multisite clinical trial DCE-CT accreditation.

Abstract:

PURPOSE:Credentialing can have an impact on whether or not a clinical trial produces useful quality data that is comparable between various institutions and scanners. With the recent increase of dynamic contrast enhanced-computed tomography (DCE-CT) usage as a companion biomarker in clinical trials, effective quality assurance, and control methods are required to ensure there is minimal deviation in the results between different scanners and protocols at various institutions. This paper attempts to address this problem by utilizing a dynamic flow imaging phantom to develop and evaluate a DCE-CT quality assurance (QA) protocol. METHODS:A previously designed flow phantom, capable of producing predictable and reproducible time concentration curves from contrast injection was fully validated and then utilized to design a DCE-CT QA protocol. The QA protocol involved a set of quantitative metrics including injected and total mass error, as well as goodness of fit comparison to the known truth concentration curves. An additional region of interest (ROI) sensitivity analysis was also developed to provide additional details on intrascanner variability and determine appropriate ROI sizes for quantitative analysis. Both the QA protocol and ROI sensitivity analysis were utilized to test variations in DCE-CT results using different imaging parameters (tube voltage and current) as well as alternate reconstruction methods and imaging techniques. The developed QA protocol and ROI sensitivity analysis was then applied at three institutions that were part of clinical trial involving DCE-CT and results were compared. RESULTS:The inherent specificity of robustness of the phantom was determined through calculation of the total intraday variability and determined to be less than 2.2±1.1% (total calculated output contrast mass error) with a goodness of fit (R2) of greater than 0.99±0.0035 (n=10). The DCE-CT QA protocol was capable of detecting significant deviations from the expected phantom result when scanning at low mAs and low kVp in terms of quantitative metrics (Injected Mass Error 15.4%), goodness of fit (R2) of 0.91, and ROI sensitivity (increase in minimum input function ROI radius by 146±86%). These tests also confirmed that the ASIR reconstruction process was beneficial in reducing noise without substantially increasing partial volume effects and that vendor specific modes (e.g., axial shuttle) did not significantly affect the phantom results. The phantom and QA protocol were finally able to quickly (<90 min) and successfully validate the DCE-CT imaging protocol utilized at the three separate institutions of a multicenter clinical trial; thereby enhancing the confidence in the patient data collected. CONCLUSIONS:A DCE QA protocol was developed that, in combination with a dynamic multimodality flow phantom, allows the intrascanner variability to be separated from other sources of variability such as the impact of injection protocol and ROI selection. This provides a valuable resource that can be utilized at various clinical trial institutions to test conformance with imaging protocols and accuracy requirements as well as ensure that the scanners are performing as expected for dynamic scans.

journal_name

Med Phys

journal_title

Medical physics

authors

Driscoll B,Keller H,Jaffray D,Coolens C

doi

10.1118/1.4812429

subject

Has Abstract

pub_date

2013-08-01 00:00:00

pages

081906

issue

8

eissn

0094-2405

issn

2473-4209

journal_volume

40

pub_type

杂志文章
  • Impact of calibration methods for color medical displays on interpreting brain SPECT images.

    abstract:PURPOSE:Color images are visualized on medical monitors that are adjusted by a grayscale standard display function (GSDF) or γ2.2. Although the GSDF is visually displayed as a linear graded grayscale, it does not specify how color medical images should be presented. On the other hand, the usual gamma setting for color ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13532

    authors: Shibutani T,Onoguchi M,Yoneyama H,Nakajima K,Matsuo S,Bamba Y,Saito S

    更新日期:2019-06-01 00:00:00

  • Experimental implementation of a joint statistical image reconstruction method for proton stopping power mapping from dual-energy CT data.

    abstract:PURPOSE:To experimentally commission a dual-energy CT (DECT) joint statistical image reconstruction (JSIR) method, which is built on a linear basis vector model (BVM) of material characterization, for proton stopping power ratio (SPR) estimation. METHODS:The JSIR-BVM method builds on the relationship between the energ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13287

    authors: Zhang S,Han D,Williamson JF,Zhao T,Politte DG,Whiting BR,O'Sullivan JA

    更新日期:2019-01-01 00:00:00

  • Volumetric breast density evaluation from ultrasound tomography images.

    abstract::Previous ultrasound tomography work conducted by our group showed a direct correlation between measured sound speed and physical density in vitro, and increased in vivo sound speed with increasing mammographic density, a known risk factor for breast cancer. Building on these empirical results, the purpose of this work...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2964092

    authors: Glide-Hurst CK,Duric N,Littrup P

    更新日期:2008-09-01 00:00:00

  • Detecting electron beam energy shifts with a commercially available energy monitor.

    abstract::Routine electron beam quality assurance requires an accurate, yet practical, method of energy characterization. Subtle shifts in beam energy may be produced by the linac bending magnet assembly, and the sensitivity of a commercially available electron beam energy-monitoring device for monitoring these small energy dri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.599033

    authors: Evans MD,Moftah BA,Olivares M,Podgorsak EB

    更新日期:2000-07-01 00:00:00

  • Task-based assessment of breast tomosynthesis: effect of acquisition parameters and quantum noise.

    abstract:PURPOSE:Tomosynthesis is a promising modality for breast imaging. The appearance of the tomosynthesis reconstructed image is greatly affected by the choice of acquisition and reconstruction parameters. The purpose of this study was to investigate the limitations of tomosynthesis breast imaging due to scan parameters an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3357288

    authors: Reiser I,Nishikawa RM

    更新日期:2010-04-01 00:00:00

  • Validation of GPU-accelerated superposition-convolution dose computations for the Small Animal Radiation Research Platform.

    abstract:PURPOSE:The Small Animal Radiation Research Platform (SARRP) has been developed for conformal microirradiation with on-board cone beam CT (CBCT) guidance. The graphics processing unit (GPU)-accelerated Superposition-Convolution (SC) method for dose computation has been integrated into the treatment planning system (TPS...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12862

    authors: Cho N,Tsiamas P,Velarde E,Tryggestad E,Jacques R,Berbeco R,McNutt T,Kazanzides P,Wong J

    更新日期:2018-05-01 00:00:00

  • Mitigating differential baseline shifts in locally advanced lung cancer patients using an average anatomy model.

    abstract:BACKGROUND AND PURPOSE:Differential baseline shifts between primary tumor and involved lymph nodes in locally advanced lung cancer patients compromise the accuracy of radiotherapy. The purpose of this study was to evaluate the performance of an average anatomy model (AAM) derived from repeat imaging and deformable regi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12271

    authors: Abdoli M,Van Kranen SR,Stankovic U,Rossi MMG,Belderbos JSA,Sonke JJ

    更新日期:2017-07-01 00:00:00

  • Spectra and air-kerma strength for encapsulated 192Ir sources.

    abstract::The photon spectra in vacuum around four types of 192Ir HDR brachytherapy sources are calculated using the Monte Carlo code EGS4 and the most recent spectral information on 192Ir decay. The air-kerma strengths per unit activity are calculated based on the photon fluence around a bare 192Ir source and around each of fo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598763

    authors: Borg J,Rogers DW

    更新日期:1999-11-01 00:00:00

  • Comparison of an amorphous silicon/cesium iodide flat-panel digital chest radiography system with screen/film and computed radiography systems--a contrast-detail phantom study.

    abstract::Flat-panel (FP) based digital radiography systems have recently been introduced as a new and improved digital radiography technology; it is important to evaluate and compare this new technology with currently widely used conventional screen/film (SF) and computed radiography (CR) techniques. In this study, the low-con...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1408620

    authors: Rong XJ,Shaw CC,Liu X,Lemacks MR,Thompson SK

    更新日期:2001-11-01 00:00:00

  • In vitro in-stent restenoses evaluated by 3D ultrasound.

    abstract::The purpose of this study was to quantify in-stent restenoses with 3D B mode and power Doppler ultrasound (U.S.) imaging. In-stent restenoses were mimicked with vascular phantoms in which a nonferromagnetic prototype stent (Boston Scientific) and a ferromagnetic clinical stainless steel stent (Palmaz P295) were embedd...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3062944

    authors: Lécart M,Cardinal MH,Qin Z,Soulez G,Cloutier G

    更新日期:2009-02-01 00:00:00

  • SU-E-J-58: Patient-Specific Biomechanical Head and Neck Models for Interfraction Dose Accumulation.

    abstract:PURPOSE:In this abstract, we discuss a biomechanical head and neck model that will be able to represent patient setup variations as well as physiologic changes and subsequently enable dose calculations on the deformed anatomy. METHODS:We selected Multi Pose MRI as the imaging modality to aid in model development and v...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734893

    authors: Santhanam A,Ennis D,Low D,Kupelian P

    更新日期:2012-06-01 00:00:00

  • Automated segmentation of anatomic regions in chest radiographs using an adaptive-sized hybrid neural network.

    abstract::The purposes of this research are to investigate the effectiveness of our novel image features for segmentation of anatomic regions such as the lungs and the mediastinum in chest radiographs and to develop an automatic computerized method for image processing. A total of 85 screening chest radiographs from Johns Hopki...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598277

    authors: Tsujii O,Freedman MT,Mun SK

    更新日期:1998-06-01 00:00:00

  • SU-E-I-69: Magnetic Resonance Metal Artifact Evaluation with Routine Clinical Cardiac Sequences.

    abstract:PURPOSE:To examine schemes to grade the severity of metal susceptibility artifacts on image quality using cardiac MRI pulse sequences. METHODS:A post-thoracotomy patient was simulated with a stainless steel sternal wire (Syneture,MA; size=6, diameter=48mm), placed securely on an ACR MRI phantom. Phantom was scanned on...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734785

    authors: Joyner D,Rivard A,Craft D,Liu T,Callaway S,James J

    更新日期:2012-06-01 00:00:00

  • State-of-the-art in two-dimensional ultrasonic transducer array technology.

    abstract::Attention is given to means of sensing ultrasonic energy distributions over an area. Under the restraints appropiate to real-time imaging of deep body organs, piezoelectric arrays offer the most promising method. Adaptation of integrated circuit techniques to array assembly permits very large arrays of small elements ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594247

    authors: Maginness MG,Plummer JD,Beaver WL,Meindl JD

    更新日期:1976-09-01 00:00:00

  • Designing a wax phantom to simulate a flat tumor with diffuse edges.

    abstract::A suitable was phantom was designed for evaluating various film techniques used in subtraction radiography. Holes are drilled in a slab of wax and filled with various concentrations of iodinated wax, producing disk-shaped regions with diffuse borders. The technical details of construction and a representative applicat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594371

    authors: Ort MG,Gregg EC

    更新日期:1977-05-01 00:00:00

  • Reconstruction of 4-MV bremsstrahlung spectra from measured transmission data.

    abstract::Transmission data for 4-MV bremsstrahlung beams have been measured with a combination of lead and aluminum attenuators. From these data, the original energy spectra have been reconstructed using an iterative least-squares technique, previously evaluated by simulation studies. The spectra on the central axis for three ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595356

    authors: Huang PH,Kase KR,Bjärngard BE

    更新日期:1983-11-01 00:00:00

  • A dose-point-kernel model for a low energy gamma-emitting stent in a heterogeneous medium.

    abstract::A computer dose model for a low energy gamma-emitting stent in a heterogeneous medium is described. The method is based on the Sievert model which is adapted to the dose-point-kernel (DPK) model to compute the dose distribution about filtered gamma sources (Sievert-DPK model). The new gamma stent model can take into a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1380214

    authors: Janicki C,Duggan DM,Rahdert DA

    更新日期:2001-07-01 00:00:00

  • Design and optimization of large area thin-film CdTe detector for radiation therapy imaging applications.

    abstract:PURPOSE:The authors investigate performance of thin-film cadmium telluride (CdTe) in detecting high-energy (6 MV) x rays. The utilization of this material has become technologically feasible only in recent years due to significant development in large area photovoltaic applications. METHODS:The CdTe film is combined w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3438082

    authors: Parsai EI,Shvydka D,Kang J

    更新日期:2010-08-01 00:00:00

  • Potential of high-Z contrast agents in clinical contrast-enhanced computed tomography.

    abstract:PURPOSE:Currently, only iodine- and barium-based contrast media (CM) are used in clinical contrast-enhanced computed tomography (CE-CT). High-Z metals would produce a higher contrast at equal mass density for the x-ray spectra used in clinical CT. Using such materials might allow for significant dose reductions in CE-C...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3658738

    authors: Nowak T,Hupfer M,Brauweiler R,Eisa F,Kalender WA

    更新日期:2011-12-01 00:00:00

  • SU-E-J-63: Feasibility Study of Proton Digital Tomosynthesis in Proton Beam Therapy.

    abstract:PURPOSE:We investigated the feasibility of proton tomosynthesis as daily positioning of patients and compared the results with photon tomosynthesis as an alternative to conventional portal imaging or on-board cone-beam computed tomography. METHODS:Dedicated photon-like proton beam using the passively scattered proton ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734898

    authors: Min B,Kwak J,Lee J,Cho S,Park S,Yoo S,Chung K,Cho S,Lim Y,Shin D,Lee S,Kim J

    更新日期:2012-06-01 00:00:00

  • Optimized radial and angular positions in Monte Carlo modeling.

    abstract::In Monte Carlo simulations of light transport in tissues, a grid system is set up to score physical quantities. This study of cylindrically symmetrical problems found that the optimized radial and angular positions for the averaged physical quantities in each grid element are off-center. The error of the extrapolated ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597351

    authors: Wang L,Jacques SL

    更新日期:1994-07-01 00:00:00

  • Evaluation of the accuracy of fetal dose estimates using TG-36 data.

    abstract::The American Association of Physicists in Medicine Radiation Therapy Committee Task Group 36 report (TG-36) provides guidelines for managing radiation therapy of pregnant patients. Included in the report are data that can be used to estimate the dose to the fetus. The purpose of this study is to evaluate the accuracy ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2710332

    authors: Kry SF,Starkschall G,Antolak JA,Salehpour M

    更新日期:2007-04-01 00:00:00

  • Application of the TRS 483 code of practice for reference and relative dosimetry in tomotherapy.

    abstract:PURPOSE:To apply the recent code of practice from the IAEA/AAPM, TRS 483, to helical tomotherapy (HT) for reference and relative dosimetry obtaining correction factors for the Exradin A1SL ionization chamber. METHODS:The beam quality correction factor for the A1SL chamber was obtained through three different approache...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13855

    authors: Lopes MDC,Santos T,Ventura T,Capela M

    更新日期:2019-12-01 00:00:00

  • 3T MRI evaluation of the accuracy of atlas-based subthalamic nucleus identification.

    abstract::Modulation of the activity of the subthalamic nucleus (STN) using deep brain stimulation (DBS) in patients with advanced Parkinson's disease is the most common procedure performed today by functional neurosurgeons. The STN contours cannot be entirely identified on common 1.5 T images; in particular, the ventromedial b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2936229

    authors: Stancanello J,Muacevic A,Sebastiano F,Modugno N,Cerveri P,Ferrigno G,Uggeri F,Romanelli P

    更新日期:2008-07-01 00:00:00

  • Average glandular dose coefficients for pendant-geometry breast CT using realistic breast phantoms.

    abstract:PURPOSE:To design volume-specific breast phantoms from breast CT (bCT) data sets and estimate the associated normalized mean glandular dose coefficients for breast CT using Monte Carlo methods. METHODS:A large cohort of bCT data sets (N = 215) was used to evaluate breast volume into quintiles (plus the top 5%). The av...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12477

    authors: Hernandez AM,Boone JM

    更新日期:2017-10-01 00:00:00

  • Patient dose simulations for scanning-beam digital x-ray tomosynthesis of the lungs.

    abstract:PURPOSE:An improved method of image guidance for lung tumor biopsies could help reduce the high rate of false negatives. The aim of this work is to optimize the geometry of the scanning-beam digital tomography system (SBDX) for providing real-time 3D tomographic reconstructions for target verification. The unique geome...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4826159

    authors: Nelson G,Yoon S,Krishna G,Wilfley B,Fahrig R

    更新日期:2013-11-01 00:00:00

  • Higher energy: is it necessary, is it worth the cost for radiation oncology?

    abstract::The physical characteristics of the interactions of megavoltage photons and electrons with matter provide distinct advantages, relative to low-energy (orthovoltage) x rays, that lead to better radiation dose distributions in patients. Use of these high-energy radiations has resulted in better patient care, which has b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596779

    authors: Das IJ,Kase KR

    更新日期:1992-07-01 00:00:00

  • Differences among Monte Carlo codes in the calculations of voxel S values for radionuclide targeted therapy and analysis of their impact on absorbed dose evaluations.

    abstract::Several updated Monte Carlo (MC) codes are available to perform calculations of voxel S values for radionuclide targeted therapy. The aim of this work is to analyze the differences in the calculations obtained by different MC codes and their impact on absorbed dose evaluations performed by voxel dosimetry. Voxel S val...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3103401

    authors: Pacilio M,Lanconelli N,Lo MS,Betti M,Montani L,Torres AL,Coca PM

    更新日期:2009-05-01 00:00:00

  • A novel computer-aided lung nodule detection system for CT images.

    abstract:PURPOSE:The paper presents a complete computer-aided detection (CAD) system for the detection of lung nodules in computed tomography images. A new mixed feature selection and classification methodology is applied for the first time on a difficult medical image analysis problem. METHODS:The CAD system was trained and t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3633941

    authors: Tan M,Deklerck R,Jansen B,Bister M,Cornelis J

    更新日期:2011-10-01 00:00:00

  • A topographic leaf-sequencing algorithm for delivering intensity modulated radiation therapy.

    abstract::Topographic treatment is a radiation therapy delivery technique for fixed-gantry (nonrotational) treatments on a helical tomotherapy system. The intensity-modulated fields are created by moving the treatment couch relative to a fan-beam positioned at fixed gantry angles. The delivered dose distribution is controlled b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2216876

    authors: Desai D,Ramsey CR,Breinig M,Mahan SL

    更新日期:2006-08-01 00:00:00