Abstract:
PURPOSE:Credentialing can have an impact on whether or not a clinical trial produces useful quality data that is comparable between various institutions and scanners. With the recent increase of dynamic contrast enhanced-computed tomography (DCE-CT) usage as a companion biomarker in clinical trials, effective quality assurance, and control methods are required to ensure there is minimal deviation in the results between different scanners and protocols at various institutions. This paper attempts to address this problem by utilizing a dynamic flow imaging phantom to develop and evaluate a DCE-CT quality assurance (QA) protocol. METHODS:A previously designed flow phantom, capable of producing predictable and reproducible time concentration curves from contrast injection was fully validated and then utilized to design a DCE-CT QA protocol. The QA protocol involved a set of quantitative metrics including injected and total mass error, as well as goodness of fit comparison to the known truth concentration curves. An additional region of interest (ROI) sensitivity analysis was also developed to provide additional details on intrascanner variability and determine appropriate ROI sizes for quantitative analysis. Both the QA protocol and ROI sensitivity analysis were utilized to test variations in DCE-CT results using different imaging parameters (tube voltage and current) as well as alternate reconstruction methods and imaging techniques. The developed QA protocol and ROI sensitivity analysis was then applied at three institutions that were part of clinical trial involving DCE-CT and results were compared. RESULTS:The inherent specificity of robustness of the phantom was determined through calculation of the total intraday variability and determined to be less than 2.2±1.1% (total calculated output contrast mass error) with a goodness of fit (R2) of greater than 0.99±0.0035 (n=10). The DCE-CT QA protocol was capable of detecting significant deviations from the expected phantom result when scanning at low mAs and low kVp in terms of quantitative metrics (Injected Mass Error 15.4%), goodness of fit (R2) of 0.91, and ROI sensitivity (increase in minimum input function ROI radius by 146±86%). These tests also confirmed that the ASIR reconstruction process was beneficial in reducing noise without substantially increasing partial volume effects and that vendor specific modes (e.g., axial shuttle) did not significantly affect the phantom results. The phantom and QA protocol were finally able to quickly (<90 min) and successfully validate the DCE-CT imaging protocol utilized at the three separate institutions of a multicenter clinical trial; thereby enhancing the confidence in the patient data collected. CONCLUSIONS:A DCE QA protocol was developed that, in combination with a dynamic multimodality flow phantom, allows the intrascanner variability to be separated from other sources of variability such as the impact of injection protocol and ROI selection. This provides a valuable resource that can be utilized at various clinical trial institutions to test conformance with imaging protocols and accuracy requirements as well as ensure that the scanners are performing as expected for dynamic scans.
journal_name
Med Physjournal_title
Medical physicsauthors
Driscoll B,Keller H,Jaffray D,Coolens Cdoi
10.1118/1.4812429subject
Has Abstractpub_date
2013-08-01 00:00:00pages
081906issue
8eissn
0094-2405issn
2473-4209journal_volume
40pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Optoacoustic imaging enables mapping the optical absorption of biological tissue using optical excitation and acoustic detection. Although most image-reconstruction algorithms are based on the assumption of a detector with an isotropic sensitivity, the geometry of the detector often leads to a response with spa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3589141
更新日期:2011-07-01 00:00:00
abstract:PURPOSE:To improve image quality and reduce imaging dose in CBCT for radiation therapy applications and to realize near real-time image reconstruction based on use of a fast convergence iterative algorithm and acceleration by multi-GPUs. METHODS:An iterative image reconstruction that sought to minimize a weighted leas...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735747
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To present a system for robotic 4D ultrasound (US) imaging concurrent with radiotherapy beam delivery and estimate the proportion of liver stereotactic ablative body radiotherapy (SABR) cases in which robotic US image guidance can be deployed without interfering with clinically used VMAT beam configurations. M...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4964454
更新日期:2016-11-01 00:00:00
abstract::Two side-by-side energy windows are sometimes employed in quantitative single photon emission computed tomography (SPECT) studies. The count-rate losses at high activities for a GE400AT camera were measured in such a dual-window-acquisition mode by imaging a decaying source composed of a hot sphere within a warm cylin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597008
更新日期:1993-07-01 00:00:00
abstract:PURPOSE:Sterile radiation reduction gloves have been widely used in the past decade to provide modest decreases in operator hand dose when the hands are placed in the field of view (FOV). While multiple publications have quantified the potential dose reduction from the use of such gloves, possible effects on the patien...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734747
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Elastography using computer tomography (CT) is a promising methodology that can provide patient-specific regional distributions of lung biomechanical properties. The purpose of this paper is to investigate the feasibility of performing elastography using simulated lower dose CT scans. METHODS:A cohort of eight...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14112
更新日期:2020-08-01 00:00:00
abstract::Extensive information has been made available relative to the physical aspects necessary for calculation of radiation absorbed dose from radiopharmaceuticals. A similar data base for the biological factors involved in these calculations has not been documented as thoroughly. The authors present an extensive literature...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594679
更新日期:1980-05-01 00:00:00
abstract:PURPOSE:The focus of this work was the demonstration and validation of VirtuaLinac with clinical photon beams and to investigate the implementation of low-Z targets in a TrueBeam linear accelerator (Linac) using Monte Carlo modeling. METHODS:VirtuaLinac, a cloud based web application utilizing Geant4 Monte Carlo code,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4861818
更新日期:2014-02-01 00:00:00
abstract::The dose distribution for an ovoid with a new tungsten shielding design was determined using Monte Carlo simulation. Standard Cesium-137 tube sources, tungsten shielding, and aluminum ovoid applicator were each modeled as a collection of solid objects. Dose was calculated in planes above, below, in front of, and on th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598459
更新日期:1998-12-01 00:00:00
abstract::Photon point dose kernels and absorbed fractions were generated in water for the full photon emission spectrum of each radionuclide of interest in nuclear medicine, by simulating the transport of particles using Monte Carlo. The kernels were then fitted to a mathematical expression. Absorbed fractions for point source...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597670
更新日期:1996-05-01 00:00:00
abstract::An electronic scanning-slit technology is under development which involves replacing paired fore and aft slits for scatter rejection with only one fore slit. As the slit scans across the portion of the patient to be imaged, pulsed x-ray exposures produce images of the slit in successive positions, which are digitized ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595940
更新日期:1986-03-01 00:00:00
abstract:PURPOSE:Discuss optimised Accelerated Partial Breast Irradiation (APBI) using a Strut-Adjused Volume Implant (SAVI) applicator for patients with implanted pacemeker, without overdosing or relocating the pacemaker. METHODS:A right breast cancer patient with an in situ pacemaker (Medtronic model ADDR01) on the right sid...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735299
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The authors are developing a system for calibrated breast density measurements using full field digital mammography (FFDM). Breast tissue equivalent (BTE) phantom images are used to establish baseline (BL) calibration curves at time zero. For a given FFDM unit, the full BL dataset is comprised of approximately ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4903299
更新日期:2015-02-01 00:00:00
abstract:PURPOSE:To determine the accuracy and reproducibility of the automatic- setup procedure of a 3D water scanner (3D SCANNER, Sun Nuclear Corp). The procedure automatically aligns the scanner's coordinate system to the Linac coordinate system. A unique off-center detector holder extends the scan range to 630 mm, eliminati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734668
更新日期:2012-06-01 00:00:00
abstract::Variation of the photoactivation rate across radiation fields of three different bremsstrahlung beams of two medical accelerators has been measured, making use of the photonuclear reactions in natural indium probes: 115In(y,y')115mIn and 115In(y,n)114mIn. The third nuclear reaction, 115In(n,y)116mIn, was used to detec...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598558
更新日期:1999-04-01 00:00:00
abstract:PURPOSE:In current clinical practice, there is no integrated 3D ultrasound (3DUS) guidance system clinically available for breast brachytherapy. In this study, the authors present a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial high dose rate (HDR) brachytherapy treatment. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4934832
更新日期:2015-12-01 00:00:00
abstract::The minimum margins required to compensate for random geometric uncertainties in the delivery of radiotherapy treatment were determined for a spherical Clinical Target Volume, using an analytic model for the cumulative dose. Margins were calculated such that the minimum dose in the target would be no less than 95% of ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1809991
更新日期:2004-11-01 00:00:00
abstract:PURPOSE:We propose a new method for efficient particle transportation in voxelized geometry for Monte Carlo simulations. We describe its use for calculating dose distribution in CT images for radiation therapy. MATERIAL AND METHODS:The proposed approach, based on an implicit volume representation named segmented volum...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2884854
更新日期:2008-04-01 00:00:00
abstract::Small photon fields are increasingly used in modern radiotherapy and especially in IMRT and SRS/SRT treatments. The uncertainties related to small field profile measurements can introduce significant systematic errors to the overall treatment process. These measurements are challenging mainly due to the absence of cha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2977829
更新日期:2008-10-01 00:00:00
abstract::Segmentation of the lungs within magnetic resonance (MR) scans is a necessary step in the computer-based analysis of thoracic MR images. This process is often confounded by image acquisition artifacts and disease-induced morphological deformation. We have developed an automated method for lung segmentation that is ins...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2214165
更新日期:2006-09-01 00:00:00
abstract:PURPOSE:To propose a method to calculate the tissue phantom ratio (TPR) using the depth dose and to compare the proposed method with two other methods. METHODS:An analytical dose model from Bjärngard was used to describe the depth dose and the TPR. The parameters of the model were derived from depth dose measurements,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3570575
更新日期:2011-05-01 00:00:00
abstract:PURPOSE:New technology has been developed to treat age-related macular degeneration (AMD) using 100 kVp pencil-beams that enter the patient through the radio-resistant sclera with a depth of interest between 1.6 and 2.6 cm. Measurement of reference and relative dose in a kilovoltage x-ray beam with a 0.42 cm diameter f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4863482
更新日期:2014-02-01 00:00:00
abstract:PURPOSE:In this study, we evaluated the degree of consistency between size metrics obtained from PEM and MRI to determine the intrinsic effectiveness of a multimodality approach using these two systems for breast imaging. METHODS:Under an IRB-approved protocol, 42 cases were considered (16 patients with 28 lesions), e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735979
更新日期:2012-06-01 00:00:00
abstract::AAPM Magnetic Resonance Task Group #9 on proton magnetic resonance spectroscopy (MRS) in the brain was formed to provide a reference document for acquiring and processing proton (1H) MRS acquired from brain tissue. MRS is becoming a common adjunct to magnetic resonance imaging (MRI), especially for the differential di...
journal_title:Medical physics
pub_type: 指南,杂志文章,实务指引,评审
doi:10.1118/1.1501822
更新日期:2002-09-01 00:00:00
abstract:PURPOSE:With the increased commercial availability of intensity modulated arc therapy (IMAT) comes the need for comprehensive QA programs, covering the different aspects of this newly available technology. This manuscript proposes such a program for the RapidArc (RA) (Varian Medical Systems, Palo Alto) IMAT solution. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3622672
更新日期:2011-09-01 00:00:00
abstract:PURPOSE:Because the small-radius photon beams shaped by cones in stereotactic radiosurgery (SRS) lack lateral electronic equilibrium and a detector's finite cross section, direct experimental measurement of dosimetric data for these beams can be subject to large uncertainties. As the dose calculation accuracy of a trea...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3488900
更新日期:2010-10-01 00:00:00
abstract:PURPOSE:Respiratory motion in the chest region during single photon emission computed tomography (SPECT) is a major degrading factor that reduces the accuracy of image quantification. This effect is more notable when the tumor is very small, or the spatial resolution of the imaging system is less than the respiratory m...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13807
更新日期:2019-11-01 00:00:00
abstract::Complementary metal-oxide-semiconductors (CMOS) active pixel sensors can be optically coupled to CsI:Tl phosphors forming a indirect active pixel flat panel imager (APFPI) for high performance medical imaging. The aim of this work is to determine the x-ray imaging capabilities of CMOS-based APFPI and study the signal ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3036117
更新日期:2009-01-01 00:00:00
abstract::A simple approach was developed that calculates the output factors and tissue maximum ratio of an asymmetric field at any point within the open field, and specifically both at the central axis (when the jaws do not shadow it) and at the effective center of the open field, using the existing tables for symmetric fields...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597524
更新日期:1995-01-01 00:00:00
abstract:PURPOSE:Transcranial magnetic resonance-guided focused ultrasound surgery is a noninvasive technique for causing selective tissue necrosis. Variations in density, thickness, and shape of the skull cause aberrations in the location and shape of the focal zone. In this paper, the authors propose a hybrid simulation-MR-AR...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4865778
更新日期:2014-03-01 00:00:00