Abstract:
PURPOSE:Proton computed tomography (pCT) will enable accurate prediction of proton and ion range in a patient while providing the benefit of lower radiation exposure than in x-ray CT. The accuracy of the range prediction is essential for treatment planning in proton or ion therapy and depends upon the detector used to evaluate the water-equivalent path length (WEPL) of a proton passing through the object. A novel approach is presented for an inexpensive WEPL detector for pCT and proton radiography. METHODS:A novel multistage detector with an aperture of 10 × 37.5 cm was designed to optimize the accuracy of the WEPL measurements while simplifying detector construction and the performance requirements of its components. The design of the five-stage detector was optimized through simulations based on the geant4 detector simulation toolkit, and the fabricated prototype was calibrated in water-equivalent millimeters with 200 MeV protons in the research beam line of the clinical proton synchrotron at Loma Linda University Medical Center. A special polystyrene step phantom was designed and built to speed up and simplify the calibration procedure. The calibrated five-stage detector was tested in the 200 MeV proton beam as part of the pCT head scanner, using a water phantom and polystyrene slabs to verify the WEPL reconstruction accuracy. RESULTS:The beam-test results demonstrated excellent performance of the new detector, in good agreement with the simulation results. The WEPL measurement accuracy is about 3.0 mm per proton in the 0-260 mm WEPL range required for a pCT head scan with a 200 MeV proton beam. CONCLUSIONS:The new multistage design approach to WEPL measurements for proton CT and radiography has been prototyped and tested. The test results show that the design is competitive with much more expensive calorimeter and range-counter designs.
journal_name
Med Physjournal_title
Medical physicsauthors
Bashkirov VA,Schulte RW,Hurley RF,Johnson RP,Sadrozinski HF,Zatserklyaniy A,Plautz T,Giacometti Vdoi
10.1118/1.4939255subject
Has Abstractpub_date
2016-02-01 00:00:00pages
664-74issue
2eissn
0094-2405issn
2473-4209journal_volume
43pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:In the context of fluorescence diffuse optical tomography, determining the optimal way to exploit the time-resolved information has been receiving much attention and different features of the time-resolved signals have been introduced. In this article, the authors revisit and generalize the notion of feature, c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3431571
更新日期:2010-06-01 00:00:00
abstract::Optical-resolution photoacoustic microscopy (OR-PAM) has been validated as a valuable tool for label-free volumetric microvascular imaging. More importantly, the advantages of noninvasiveness and measurement consistency suggest the use of OR-PAM for chronic imaging of intact microcirculation. Here, such chronic imagin...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.3137572
更新日期:2009-06-01 00:00:00
abstract:PURPOSE:This study developed and validated a Motion Artifact Quantification algorithm to automatically quantify the severity of motion artifacts on coronary computed tomography angiography (CCTA) images. The algorithm was then used to develop a Motion IQ Decision method to automatically identify whether a CCTA dataset ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13243
更新日期:2018-12-01 00:00:00
abstract:PURPOSE:Very fast Monte Carlo (MC) simulations of proton transport have been implemented recently on graphics processing units (GPUs). However, these MCs usually use simplified models for nonelastic proton-nucleus interactions. Our primary goal is to build a GPU-based proton transport MC with detailed modeling of elast...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4921046
更新日期:2015-06-01 00:00:00
abstract::The ratio between scatter dose and scatter kerma for points on the central axis of 15-MV x-ray beams has been examined by Monte Carlo calculations. This ratio, beta'S, behaves differently from that between the primary dose and kerma, beta'p. Both the primary and scatter components of beta' undergo an initial rapid bui...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597749
更新日期:1996-11-01 00:00:00
abstract::During the past decade the use of undersampled acquisition and constrained reconstruction have led to significant increases in data acquisition speed, SNR, spatial resolution and temporal resolution in MR imaging. When a separately acquired constraining image is combined with an angiographic time series the traditiona...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735797
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:X-ray microbeam radiation therapy is a preclinical concept for tumor treatment promising tissue sparing and enhanced tumor control. With its spatially separated, periodic micrometer-sized pattern, this method requires a high dose rate and a collimated beam typically available at large synchrotron radiation faci...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14433
更新日期:2020-10-01 00:00:00
abstract::Coherent scattering of x-ray photons leads to the phenomenon of x-ray diffraction, which is widely used for determining atomic structure in materials science. A technique [x-ray diffraction computed tomography (CT)] is described, analogous to conventional CT, in which the x-ray diffraction properties of a stack of two...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596063
更新日期:1987-07-01 00:00:00
abstract:PURPOSE:To develop a fluoroscopy imaging based approach that can determine the magnitude and phase variation in respiratory motion against the treatment planning images in order to quantify the online patient setup deviation in thoracic cancer IGRT for the real time adaptive patient positionadjustment. METHODS:A numer...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734876
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To improve image quality and reduce imaging dose in CBCT for radiation therapy applications and to realize near real-time image reconstruction based on use of a fast convergence iterative algorithm and acceleration by multi-GPUs. METHODS:An iterative image reconstruction that sought to minimize a weighted leas...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735747
更新日期:2012-06-01 00:00:00
abstract::The feasibility of using film dosimetry data as the input data for patient treatment planning was evaluated. The central-axis depth dose and the off-axis ratios obtained from film measurements in a solid phantom were compared with those of ion-chamber measurements in water. Two techniques were used to generate isodose...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596409
更新日期:1989-11-01 00:00:00
abstract::Three Monte Carlo photon/electron transport codes (GEPTS, EGSnrc, and MCNP) are bench-marked against dose measurements in homogeneous (both low- and high-Z) media as well as at interfaces. A brief overview on physical models used by each code for photon and electron (positron) transport is given. Absolute calorimetric...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1473134
更新日期:2002-05-01 00:00:00
abstract:PURPOSE:The x-ray performance evaluation of digital x-ray detectors is based on the calculation of the modulation transfer function (MTF), the noise power spectrum (NPS), and the resultant detective quantum efficiency (DQE). The flat images used for the extraction of the NPS should not contain any fixed pattern noise (...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3664003
更新日期:2011-12-01 00:00:00
abstract::We discuss a formalism for clinical proton beam dosimetry based on the use of ionization chamber absorbed dose-to-water calibration and beam quality correction factors. A quantity kQ, the beam quality correction factor, is defined which corrects the absorbed dose-to-water calibration factor ND,w in a reference beam of...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597768
更新日期:1996-01-01 00:00:00
abstract::The most favorable treatment for moving body anatomy should aim at utilizing organ motion to minimize the dose to sensitive structures without compromising the dose delivered to the target. The solution of the problem of appropriate intensity redistribution over different phases of body motion is achievable in dynamic...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.2804722
更新日期:2007-12-01 00:00:00
abstract:PURPOSE:To determine the accuracy of VMAT treatment planning and delivery for patients undergoing radiotherapy in the head and neck. METHOD AND MATERIALS:A dosimetric study of a typical head and neck treatment plan has been carried out using Chamber, film and TLD's placed inside an anthropomorphic phantom. Lateral and...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735478
更新日期:2012-06-01 00:00:00
abstract::An improved reconstructed stereoscopic x-ray image display system, based on the principle of binocular parallax, is described. Pulse-synchronized operation of two triode x-ray tubes and one plumbicon TV camera is employed to separate the left and right images for presentation to the two eyes, respectively. The princip...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595365
更新日期:1983-09-01 00:00:00
abstract:PURPOSE:Photon counting arrays (PCAs), capable of measuring the spectral information of individual x-ray photons and recording that information digitally, provide a number of advantages compared to conventional, energy-integrating active matrix flat-panel imagers - such as reducing the undesirable effects of electronic...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13128
更新日期:2018-10-01 00:00:00
abstract:PURPOSE:Partial scan reconstruction (PSR) artifacts are present in myocardial perfusion imaging using dynamic multidetector computed tomography (MDCT). PSR artifacts appear as temporal CT number variations due to inconsistencies in the angular data range used to reconstruct images and compromise the quantitative value ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3665767
更新日期:2012-01-01 00:00:00
abstract::A proton dose computational algorithm, performing an analytical superposition of infinitely narrow proton beamlets (ASPB) is introduced. The algorithm uses the standard pencil beam technique of laterally distributing the central axis broad beam doses according to the Moliere scattering theory extended to slablike vary...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2064887
更新日期:2005-12-01 00:00:00
abstract:PURPOSE:To find an upper bound on the maximum dose reduction possible for any reconstruction algorithm, analytic or iterative, that result from the inclusion of the data statistics. The authors do not analyze noise reduction possible from prior knowledge or assumptions about the object. METHODS:The authors examined th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4941954
更新日期:2016-03-01 00:00:00
abstract:PURPOSE:To introduce video surface imaging guidance in synchronization with 4D cone-beam CT (CBCT) scans, and in combination with respiration- gated or target-tracked dose delivery to treat mobile tumors, without collaterally damaging nearby critical structures. METHODS:The approach uses the concept that the integral ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734688
更新日期:2012-06-01 00:00:00
abstract::Available deformable registration methods are often inaccurate over large organ variation encountered, for example, in the rectum and bladder. The authors developed a novel approach to accurately and effectively register large deformations in the prostate region for adaptive radiation therapy. A software tool combinin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3095777
更新日期:2009-04-01 00:00:00
abstract:PURPOSE:Cone-beam computed tomography (CBCT) is an increasingly utilized imaging modality for the diagnosis and treatment planning of the patients with craniomaxillofacial (CMF) deformities. Accurate segmentation of CBCT image is an essential step to generate three-dimensional (3D) models for the diagnosis and treatmen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4868455
更新日期:2014-04-01 00:00:00
abstract::As a quality control procedure, a post-implant seed migration survey has been accomplished on 340 prostate cancer patients since November 2001. Pulmonary seed embolization and intracardiac seed embolization have been detected. A case of thyroid uptake due to leaking iodine-125 (I-125) sources was also seized. In order...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2207319
更新日期:2006-07-01 00:00:00
abstract:PURPOSE:Dose verification in highly conformal radiation therapy such as IMRT or proton therapy can benefit from the high spatial resolution offered by radio-chromic films such as Gafchromic EBT or EBT2. Recently, a new generation of these films, EBT3, has become available. The composition and thickness of the sensitive...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4737890
更新日期:2012-08-01 00:00:00
abstract:PURPOSE:Multiple anatomy optimization (MAO) utilizing deformable dose accumulation on entire 4DCT data sets is implemented to overcome ambiguity between optimal dose defined on a single anatomy and optimal accumulated dose resulting from dose delivery to moving and deforming anatomy. METHODS:Six lung cancer patients a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735744
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Scatter is a major factor degrading the image quality of cone beam computed tomography (CBCT). Conventional scatter correction strategies require handcrafted analytical models with ad hoc assumptions, which often leads to less accurate scatter removal. This study aims to develop an effective scatter correction ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13583
更新日期:2019-07-01 00:00:00
abstract::The Radiological Physics Center (RPC) developed two heterogeneous anthropomorphic quality assurance phantoms for use in verifying the accuracy of radiation delivery: one for intensity-modulated radiation therapy (IMRT) to the pelvis and the other for stereotactic body radiation therapy (SBRT) to the thorax. The purpos...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2737158
更新日期:2007-06-01 00:00:00
abstract:PURPOSE:Digital breast tomosynthesis (DBT) is becoming an important part of breast cancer screening and diagnosis. Compared to two-dimensional mammography, tomosynthesis introduces limited three-dimensional (3D) resolution, but maintains high in-plane resolution, low dose, and allows for similar clinical protocols. The...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13116
更新日期:2018-10-01 00:00:00