Abstract:
PURPOSE:Cone-beam computed tomography (CBCT) is an increasingly utilized imaging modality for the diagnosis and treatment planning of the patients with craniomaxillofacial (CMF) deformities. Accurate segmentation of CBCT image is an essential step to generate three-dimensional (3D) models for the diagnosis and treatment planning of the patients with CMF deformities. However, due to the poor image quality, including very low signal-to-noise ratio and the widespread image artifacts such as noise, beam hardening, and inhomogeneity, it is challenging to segment the CBCT images. In this paper, the authors present a new automatic segmentation method to address these problems. METHODS:To segment CBCT images, the authors propose a new method for fully automated CBCT segmentation by using patch-based sparse representation to (1) segment bony structures from the soft tissues and (2) further separate the mandible from the maxilla. Specifically, a region-specific registration strategy is first proposed to warp all the atlases to the current testing subject and then a sparse-based label propagation strategy is employed to estimate a patient-specific atlas from all aligned atlases. Finally, the patient-specific atlas is integrated into a maximum a posteriori probability-based convex segmentation framework for accurate segmentation. RESULTS:The proposed method has been evaluated on a dataset with 15 CBCT images. The effectiveness of the proposed region-specific registration strategy and patient-specific atlas has been validated by comparing with the traditional registration strategy and population-based atlas. The experimental results show that the proposed method achieves the best segmentation accuracy by comparison with other state-of-the-art segmentation methods. CONCLUSIONS:The authors have proposed a new CBCT segmentation method by using patch-based sparse representation and convex optimization, which can achieve considerably accurate segmentation results in CBCT segmentation based on 15 patients.
journal_name
Med Physjournal_title
Medical physicsauthors
Wang L,Chen KC,Gao Y,Shi F,Liao S,Li G,Shen SG,Yan J,Lee PK,Chow B,Liu NX,Xia JJ,Shen Ddoi
10.1118/1.4868455subject
Has Abstractpub_date
2014-04-01 00:00:00pages
043503issue
4eissn
0094-2405issn
2473-4209journal_volume
41pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::We believe that, for the purpose of evaluation and optimization of treatment plans, quasirandom sampling is superior to grid sampling and should be the method of choice. We believe it to be on average more efficient than grid sampling (i.e., more accurate for any given number of dose estimates) and, even more importan...
journal_title:Medical physics
pub_type: 评论,信件
doi:10.1118/1.597103
更新日期:1993-09-01 00:00:00
abstract::The head-scatter factors H were examined for four different linear accelerators and were found to be similar at field sizes larger than 3 x 3 cm2. Sharply reduced values for small collimator openings were observed for all the accelerators. It is concluded that the head-scatter (or collimator-scatter) factor has two ma...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597256
更新日期:1994-01-01 00:00:00
abstract::An improved reconstructed stereoscopic x-ray image display system, based on the principle of binocular parallax, is described. Pulse-synchronized operation of two triode x-ray tubes and one plumbicon TV camera is employed to separate the left and right images for presentation to the two eyes, respectively. The princip...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595365
更新日期:1983-09-01 00:00:00
abstract:PURPOSE:The treatment of moving targets with scanned proton beams is challenging. For motion mitigation, an Active Breathing Coordinator (ABC) can be used to assist breath-holding. The delivery of pencil beam scanning fields often exceeds feasible breath-hold durations, requiring high breath-hold reproducibility. We ev...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13195
更新日期:2018-12-01 00:00:00
abstract:PURPOSE:To provide an overview of the types of adverse events reported to the US Food and Drug Administration (US FDA) for magnetic resonance (MR) systems over a 10-yr period. METHODS:Two reviewers independently reviewed adverse events reported to FDA for MR systems from 1 January 2008 to 31 December 2017 and manually...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1002/mp.13768
更新日期:2019-12-01 00:00:00
abstract:PURPOSE:To develop a practical background compensation (BC) technique to improve quantitative (90)Y-bremsstrahlung single-photon emission computed tomography (SPECT)/computed tomography (CT) using a commercially available imaging system. METHODS:All images were acquired using medium-energy collimation in six energy wi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4960629
更新日期:2016-09-01 00:00:00
abstract:PURPOSE:To study if malfunction of a receiver can be detected robustly using the simple ACR SNR measurement approach on a 32-channel head coil. METHODS:Standard ACR T1W images (11slice) were acquired with a commercial 32 channel head coil on a 3T Philips Achieva MR scanner following the ACR recommended setup. Raw data...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736227
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Although small animal image-guided radiotherapy (SA-IGRT) systems are used increasingly in preclinical research, tools for performing routine quality assurance (QA) have not been optimized and are not readily available. Robust, efficient, and reliable QA tools are needed to ensure the accuracy and reproducibili...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12939
更新日期:2018-07-01 00:00:00
abstract::This paper compares the characteristics of three types of commercial p-type electron diodes specially designed for in vivo dosimetry (Scanditronix EDD2, Sun Nuclear QED 111200-0 and PTW T60010E diodes coupled with a Therados DPD510 dosimeter) in electron fields with energies from 4.5 to 21 MeV, and in conditions simil...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1630492
更新日期:2004-01-01 00:00:00
abstract:PURPOSE:To develop a new scintillating fiber-based electronic portal imaging device (EPID) with a high quantum efficiency (QE) while preserving an adequate spatial resolution. METHODS:Two prototypes were built: one with a single pixel readout and the other with an active matrix flat-panel imager (AMFPI) for readout. T...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13900
更新日期:2020-01-01 00:00:00
abstract::Amorphous selenium (a-Se) based real-time flat-panel imagers (FPIs) are finding their way into the digital radiology department because they offer the practical advantages of digital x-ray imaging combined with an image quality that equals or outperforms that of conventional systems. The temporal imaging characteristi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2042248
更新日期:2005-10-01 00:00:00
abstract:PURPOSE:Carpal tunnel syndrome (CTS) is the common entrapment neuropathy that occurs due to compression of the median nerve at the wrist. Ultrasound images have been used to highlight anatomical variants of the median nerve, and CTS is thought to be associated to enlargement of the cross-sectional area (CSA) of the med...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4767754
更新日期:2012-12-01 00:00:00
abstract:PURPOSE:To investigate how using different sets of decision criteria impacts the quality of intensity modulated radiation therapy (IMRT) plans obtained by multiobjective optimization. METHODS:A multiobjective optimization evolutionary algorithm (MOEA) was used to produce sets of IMRT plans. The MOEA consisted of two i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3589128
更新日期:2011-06-01 00:00:00
abstract:PURPOSE:For the purpose of size-specific dose estimation, information regarding patient attenuation is required. The purpose of this work is to describe a method for measuring patient attenuation and expressing the results in terms of a water cylinder, with cross sectional area A(w), which would absorb the same average...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4754303
更新日期:2012-11-01 00:00:00
abstract::Electron spectral reconstruction of medical accelerators from measured depth doses is a practical method for providing the input initial phase space distribution at the patient surface that is required by Monte Carlo treatment planning systems. The posed inverse problem of spectral reconstruction is ill conditioned an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2161404
更新日期:2006-02-01 00:00:00
abstract::Modern computed tomography (CT) scanners use cone-beam configurations for increasing volume coverage, improving x-ray-tube utilization, and yielding isotropic spatial resolution. Recently, there have been significant developments in theory and algorithms for exact image reconstruction from cone-beam projections. In pa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2337270
更新日期:2006-10-01 00:00:00
abstract::Available deformable registration methods are often inaccurate over large organ variation encountered, for example, in the rectum and bladder. The authors developed a novel approach to accurately and effectively register large deformations in the prostate region for adaptive radiation therapy. A software tool combinin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3095777
更新日期:2009-04-01 00:00:00
abstract:PURPOSE:Intracavitary accelerated partial breast irradiation (APBI) has become a popular treatment for early stage breast cancer in recent years due to its shortened course of treatment and simplified treatment planning compared to traditional external beam breast conservation therapy. However, the exit dose to the ski...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3429089
更新日期:2010-06-01 00:00:00
abstract:PURPOSE:To develop a pencil beam dose calculation algorithm for scanned proton beams that improves modeling of scatter events. METHODS:Our pencil beam algorithm (PBA) was developed for calculating dose from monoenergetic, parallel proton beams in homogeneous media. Fermi-Eyges theory was implemented for pencil beam tr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735624
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Signal encoding in magnetic particle imaging (MPI) is achieved by moving a field-free point (FFP) through the region of interest. One way to increase the sensitivity of the method is to scan the region of interest with a field-free line (FFL) instead of the FFP. Recently, the first feasible FFL coil setup was i...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.3447726
更新日期:2010-07-01 00:00:00
abstract::Intensity Modulated Arc Therapy (IMAT) is a rotational variant of Intensity Modulated Radiation Therapy (IMRT) that can be implemented with or without angular dose rate optimization. The purpose of this study is to determine the inter-relationship among arc range, Multi-Leaf Collimator (MLC) leaf positions and angular...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965975
更新日期:2008-07-01 00:00:00
abstract:PURPOSE:To establish accurate experimental dosimetry techniques for reference dose measurements in nonstandard composite fields. METHODS:A cylindrical PMMA phantom filled with water was constructed, at the center of which reference absorbed dose to water for a head and neck IMRT delivery was measured. Based on the pro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3392247
更新日期:2010-06-01 00:00:00
abstract:PURPOSE:The quantification of vessel wall morphology and plaque burden requires vessel segmentation, which is generally performed by manual delineations. The purpose of our work is to develop and evaluate a new 3D model-based approach for carotid artery wall segmentation from dual-sequence MRI. METHODS:The proposed me...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12476
更新日期:2017-10-01 00:00:00
abstract::In this study, BrachyDose, a recently developed EGSnrc Monte Carlo code for rapid brachytherapy dose calculations, has been benchmarked by reproducing previously published dosimetry parameters for three brachytherapy seeds with varied internal structure and encapsulation. Calculations are performed for two 125I seeds ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2400843
更新日期:2007-02-01 00:00:00
abstract::An applicator system for intraoperative radiation therapy has been fabricated which does not require physical docking with the accelerator. A dosimetric study has been completed which documents the properties of this system for a variety of electron beam energies, applicator sizes, collimator settings, both primary an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596338
更新日期:1989-09-01 00:00:00
abstract::The implementation of an improved model for multiple scattering into the-Voxel Monte Carlo (VMC) algorithm for fast electron dose calculation in radiation therapy is presented. The model takes into account path-length corrections (PLC) and lateral displacement in the individual electron steps. The extraction of the sc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597933
更新日期:1997-04-01 00:00:00
abstract::Respiration can cause tumors in the thorax or abdomen to move by as much as 3 cm; this movement can adversely affect the planning and delivery of radiation treatment. Several techniques have been used to compensate for respiratory motion, but all have shortcomings. Manufacturers of computed tomography (CT) equipment h...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2044427
更新日期:2006-01-01 00:00:00
abstract::Nuclear Magnetic Resonance (NMR) permits the noninvasive measurement of blood flow signals unimpaired by clothes, bandages, casts, etc. The cylindrical crossed-coil NMR blood flowmeter was used to measure blood flow through a cross-section of the human forearm. Two calibration procedures are described: one for pulsati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594989
更新日期:1981-07-01 00:00:00
abstract::Computer-aided diagnosis (CAD) has been a major field of research for the past few decades. CAD uses machine learning methods to analyze imaging and/or nonimaging patient data and makes assessment of the patient's condition, which can then be used to assist clinicians in their decision-making process. The recent succe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13764
更新日期:2020-06-01 00:00:00
abstract:PURPOSE:In fluoroscopy-guided clinical procedures that involve tracking objects over long treatment times, there is a need for reducing the amount of imaging dose delivered to the patient and the operating staff. In this study, we introduce a feedback metric to minimize tube current while maintaining a targeting precis...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734878
更新日期:2012-06-01 00:00:00