Theoretical investigation of the count rate capabilities of in-pixel amplifiers for photon counting arrays based on polycrystalline silicon TFTs.

Abstract:

PURPOSE:Photon counting arrays (PCAs), capable of measuring the spectral information of individual x-ray photons and recording that information digitally, provide a number of advantages compared to conventional, energy-integrating active matrix flat-panel imagers - such as reducing the undesirable effects of electronic readout noise and Swank noise. While contemporary PCAs are based on crystalline silicon, our group has been examining the use of polycrystalline silicon (poly-Si, a semiconductor material better-suited for the manufacture of large-area devices) for such arrays. In this study, a theoretical investigation of the front-end amplifiers of array pixels incorporating photon counting circuits is described - building upon circuit simulation techniques developed in a previous study. Results for amplifier circuit designs corresponding to prototype PCAs currently under development, as well as for hypothetical circuit designs identified in the study, are reported. In the simulations, performance metrics (such as signal gain, linearity of signal response, and energy resolution) as well as various measures of count rate are determined. METHODS:The simulations employed various input energy distributions (i.e., a 72 kVp spectrum as well as monoenergetic x rays) in order to determine circuit performance. To make the results representative of the properties of poly-Si, the simulations incorporated transistor characteristics that were empirically obtained from test devices. Optimal operating conditions for the circuits were determined by applying criteria to the performance metrics and identifying which conditions minimized settling time. Once the optimal operating conditions were identified, trains of input pulses simulating x-ray flux were used to determine two measures of count rate corresponding to dead time losses of 10% and 30% (referred to as CR10 and CR30 , respectively). RESULTS:The best-performing prototype amplifier design (implemented at a pixel pitch of 1 mm) exhibited CR10 and CR30 values (expressed in counts per second per pixel) of 8.4 and 21.6 kcps/pixel, respectively. A hypothetical amplifier design was derived by modifying transistor, resistor, and capacitor elements of the prototype amplifier designs. This hypothetical design (implemented at a pitch of 1 mm) exhibited CR10 and CR30 values of 154 and 381 kcps/pixel, respectively. When implemented at a pitch of 0.25 mm, the performance of that design increased to 210 and 491 kcps/pixel, respectively (corresponding to counts per second per unit area of 3.4 and 7.9 Mcps/mm2 ). CONCLUSIONS:The simulation methodology described in this paper represents a useful tool for identifying promising designs for the amplifier component of photon counting arrays, as well as evaluating the analog signal and noise performance of those designs. The results obtained from the current study support the hypothesis that large-area, photon counting arrays based on poly-Si transistors can provide clinically useful count rates. Encouraged by these early results, further development of the methodology to assist in the identification and evaluation of even more promising designs, along with development and empirical characterization of prototype designs, is planned.

journal_name

Med Phys

journal_title

Medical physics

authors

Liang AK,Koniczek M,Antonuk LE,El-Mohri Y,Zhao Q

doi

10.1002/mp.13128

subject

Has Abstract

pub_date

2018-10-01 00:00:00

pages

4418-4429

issue

10

eissn

0094-2405

issn

2473-4209

journal_volume

45

pub_type

杂志文章
  • Predicting radiotherapy-induced cardiac perfusion defects.

    abstract::The purpose of this work is to compare the efficacy of mathematical models in predicting the occurrence of radiotherapy-induced left ventricular perfusion defects assessed using single-photon emission computed tomography (SPECT). The basis of this study is data from 73 left-sided breast/ chestwall patients treated wit...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1823571

    authors: Das SK,Baydush AH,Zhou S,Miften M,Yu X,Craciunescu O,Oldham M,Light K,Wong T,Blazing M,Borges-Neto S,Dewhirst MW,Marks LB

    更新日期:2005-01-01 00:00:00

  • High resolution stationary digital breast tomosynthesis using distributed carbon nanotube x-ray source array.

    abstract:PURPOSE:The purpose of this study is to investigate the feasibility of increasing the system spatial resolution and scanning speed of Hologic Selenia Dimensions digital breast tomosynthesis (DBT) scanner by replacing the rotating mammography x-ray tube with a specially designed carbon nanotube (CNT) x-ray source array,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3694667

    authors: Qian X,Tucker A,Gidcumb E,Shan J,Yang G,Calderon-Colon X,Sultana S,Lu J,Zhou O,Spronk D,Sprenger F,Zhang Y,Kennedy D,Farbizio T,Jing Z

    更新日期:2012-04-01 00:00:00

  • A quality management program in intravascular brachytherapy.

    abstract::While simple, intravascular brachytherapy (IVB) presents a considerable potential for harm to the patient. The medical physicist maintains the responsibility to minimize the likelihood of operational problems or dosimetric errors. The principals for safe operation remain the same as with any radiotherapy treatment: to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1524167

    authors: Chakri A,Thomadsen B

    更新日期:2002-12-01 00:00:00

  • Accuracy of registration algorithms in subtraction CT of the lungs: A digital phantom study.

    abstract:PURPOSE:The purpose of this study was to assess, using an anthropomorphic digital phantom, the accuracy of algorithms in registering precontrast and contrast-enhanced computed tomography (CT) chest images for generation of iodine maps of the pulmonary parenchyma via temporal subtraction. MATERIALS AND METHODS:The XCAT...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13496

    authors: Grob D,Oostveen L,Rühaak J,Heldmann S,Mohr B,Michielsen K,Dorn S,Prokop M,Kachelrieβ M,Brink M,Sechopoulos I

    更新日期:2019-05-01 00:00:00

  • Eddy current disruption: effect on nuclear magnetic resonance coil impedance and power loss.

    abstract::We present a theoretical development and experimental verification of a description of power loss and sample resistance for a lossy sample in a nuclear magnetic resonance radio frequency coil for a sample geometry where the eddy current streamlines are disrupted from their usually assumed circular paths. Specifically ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596336

    authors: Harpen MD

    更新日期:1989-09-01 00:00:00

  • Inverse planning incorporating organ motion.

    abstract::Accurate targeting is important in intensity-modulated radiation therapy (IMRT). The positional uncertainties of structures with respect to the external beams arise in part from random organ motion and patient setup errors. While it is important to improve immobilization and reduce the influence of organ motion, the r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.599023

    authors: Li JG,Xing L

    更新日期:2000-07-01 00:00:00

  • Comparing calibration methods of electron beams using plane-parallel chambers with absorbed-dose to water based protocols.

    abstract::Recent absorbed-dose-based protocols allow for two methods of calibrating electron beams using plane-parallel chambers, one using the N(Co)D,w for a plane-parallel chamber, and the other relying on cross-calibration of the plane-parallel chamber in a high-energy electron beam against a cylindrical chamber which has an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1449876

    authors: Stewart KJ,Seuntjens JP

    更新日期:2002-03-01 00:00:00

  • An analysis of the mechanical parameters used for finite element compression of a high-resolution 3D breast phantom.

    abstract:PURPOSE:The authors previously introduced a methodology to generate a realistic three-dimensional (3D), high-resolution, computer-simulated breast phantom based on empirical data. One of the key components of such a phantom is that it provides a means to produce a realistic simulation of clinical breast compression. In...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3637500

    authors: Hsu CM,Palmeri ML,Segars WP,Veress AI,Dobbins JT 3rd

    更新日期:2011-10-01 00:00:00

  • Anniversary paper: evolution of ultrasound physics and the role of medical physicists and the AAPM and its journal in that evolution.

    abstract::Ultrasound has been the greatest imaging modality worldwide for many years by equipment purchase value and by number of machines and examinations. It is becoming increasingly the front end imaging modality; serving often as an extension of the physician's fingers. We believe that at the other extreme, high-end systems...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.2992048

    authors: Carson PL,Fenster A

    更新日期:2009-02-01 00:00:00

  • Clinical apparatus for the reduction of dose area product for patients undergoing x-ray catheterization.

    abstract:PURPOSE:The authors describe a design for prepatient region of interest attenuators (ROIAs) to reduce dose area product (DAP) for clinical use. The authors describe a model to predict DAP values from x-ray technique parameters recorded during a clinical procedure for image sequences obtained in the presence or absence ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4903898

    authors: Robert N,Watt KN,Rochette S,Desponds L,Vaillant R,Rowlands JA

    更新日期:2015-01-01 00:00:00

  • SU-E-T-236: Brachytherapy for Breast Cancer Patients with Implanted Pacemeker, Using Multi Lumen Partial Breast Applicator.

    abstract:PURPOSE:Discuss optimised Accelerated Partial Breast Irradiation (APBI) using a Strut-Adjused Volume Implant (SAVI) applicator for patients with implanted pacemeker, without overdosing or relocating the pacemaker. METHODS:A right breast cancer patient with an in situ pacemaker (Medtronic model ADDR01) on the right sid...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735299

    authors: Jacob D,Strasser J

    更新日期:2012-06-01 00:00:00

  • A chamber and electrometer calibration factor as determined by each of the five AAPM accredited dosimetry calibration laboratories.

    abstract::The same calibration grade ionization chamber and electrometer were sequentially sent to all five currently AAPM Accredited Dosimetry Calibration Laboratories (ADCL). A Cesium-137 based check device was utilized to ensure chamber and electrometer factor constancy and showed a maximum deviation of 0.32% (typically less...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596880

    authors: Blackwell CR,McCullough EC

    更新日期:1992-01-01 00:00:00

  • Anisotropy functions for 103Pd, 125I, and 192Ir interstitial brachytherapy sources.

    abstract::Anisotropy of dose distributions around 103Pd, 125I, and 192Ir sources for interstitial brachytherapy was examined. Dose rates around 125I models 6702 and 6711 and 192Ir sources were measured using lithium fluoride thermoluminescence dosimeters (LiF TLDs) in a water-equivalent, solid phantom. From these measured data ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597110

    authors: Nath R,Meigooni AS,Muench P,Melillo A

    更新日期:1993-09-01 00:00:00

  • Technical Note: A benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system with a high-power x-ray source and transmission CT imaging capability.

    abstract:PURPOSE:This report describes upgrades and performance characterization of an experimental benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system capable of determining the spatial distribution and concentration of metal probes such as gold nanoparticles (GNPs). Specifically, a high-power (~3 kW) indus...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13138

    authors: Manohar N,Reynoso FJ,Cho SH

    更新日期:2018-10-01 00:00:00

  • A comparative study of rectal dose histograms in prostate brachytherapy: some analytic and numerical results.

    abstract::A cumulative dose histogram is the graph of an integral function integrated over a domain VCR3 and is dubbed the dose-volume histogram (DVH), the dose-surface histogram (DSH) or the dose-wall histogram (DWH), depending on the dimension and structure of the region V. This paper presents a comparative study of the three...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1852811

    authors: Song JS,Albert M,D'Amico AV,Cormack RA

    更新日期:2005-02-01 00:00:00

  • A simple geometric algorithm to predict optimal starting gantry angles using equiangular-spaced beams for intensity modulated radiation therapy of prostate cancer.

    abstract::A fast, geometric beam angle optimization (BAO) algorithm for clinical intensity-modulated radiation therapy (IMRT) was implemented on ten localized prostate cancer patients on the Radiation Therapy Oncology Group (RTOG) 0126 protocol. The BAO algorithm computed the beam intersection volume (BIV) within the rectum and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2775685

    authors: Potrebko PS,McCurdy BM,Butler JB,El-Gubtan AS,Nugent Z

    更新日期:2007-10-01 00:00:00

  • Dosimetry study of Re-188 liquid balloon for intravascular brachytherapy using polymer gel dosimeters and laser-beam optical CT scanner.

    abstract::Angioplasty balloons inflated with a solution of the beta-emitter Re-188 have been used for intravascular brachytherapy to prevent restenosis. Coronary stents are in extensive clinical use for the treatment of de novo atherosclerotic stenoses. In this study, the effect of an interposed stent on the dose distribution h...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1533749

    authors: Wuu CS,Schiff P,Maryanski MJ,Liu T,Borzillary S,Weinberger J

    更新日期:2003-02-01 00:00:00

  • Dose distributions around cylindrical 241Am sources for a clinical intracavitary applicator.

    abstract::Encapsulated, cylindrical sources containing 2, 5, and 8 Ci of 241Am have been designed and fabricated for intracavitary irradiation of uterine cancers. Exposure rates in air and dose rates in water around these sources have been measured using an ionization chamber and a lithium fluoride thermoluminescent dosimetry s...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596007

    authors: Nath R,Gray L,Park CH

    更新日期:1987-09-01 00:00:00

  • Performance evaluation of computed tomography systems: Summary of AAPM Task Group 233.

    abstract:BACKGROUND:The rapid development and complexity of new x-ray computed tomography (CT) technologies and the need for evidence-based optimization of image quality with respect to radiation and contrast media dose call for an updated approach towards CT performance evaluation. AIMS:This report offers updated testing guid...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13763

    authors: Samei E,Bakalyar D,Boedeker KL,Brady S,Fan J,Leng S,Myers KJ,Popescu LM,Ramirez Giraldo JC,Ranallo F,Solomon J,Vaishnav J,Wang J

    更新日期:2019-11-01 00:00:00

  • An automated dosimetry data-acquisition and analysis system at the LAMPF pion therapy facility.

    abstract::An automated data-acquisition and analysis system has been developed for dosimetry measurements on the pion therapy beam at the Clinton P. Anderson Meson Physics Facility Biomedical Channel in Los Alamos using a PDP-11/45 computer and CAMAC interface. Initialization, test, and monitor programs allow the user to set th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594418

    authors: Rosen I,Smith A,Lane R,Kelsey C,Lake D,Hogstrom K,Somers J,Helland J,Kittell R,Amols H,Bradbury J,Richman C

    更新日期:1978-03-01 00:00:00

  • Analysis of the significance of scattered radiation in reduced dose mammography, including magnification effects, scatter suppression, and focal spot and detector blurring.

    abstract::A systems analysis of reduced dose mammography with scatter removal has quantitatively specified the relationships between the several parameters in mammography systems. While the results are only preliminary in the sense that they need to be proven experimentally, they do seem to provide a good feel for the nature of...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594540

    authors: Muntz EP

    更新日期:1979-03-01 00:00:00

  • Spacing nomograph for interstitial implants of 125I seeds.

    abstract::Permanent implants of 125I seeds at Memorial Sloan-Kettering Cancer Center are performed by the method of "dimension averaging" to determine the total activity to be implanted; that is, the activity (in mCi) is taken to be five times the average dimension (in cm) of the target region. A nomograph has recently been dev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594269

    authors: Anderson LL

    更新日期:1976-01-01 00:00:00

  • A new technique to characterize CT scanner bow-tie filter attenuation and applications in human cadaver dosimetry simulations.

    abstract:PURPOSE:To present a noninvasive technique for directly measuring the CT bow-tie filter attenuation with a linear array x-ray detector. METHODS:A scintillator based x-ray detector of 384 pixels, 307 mm active length, and fast data acquisition (model X-Scan 0.8c4-307, Detection Technology, FI-91100 Ii, Finland) was use...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4932364

    authors: Li X,Shi JQ,Zhang D,Singh S,Padole A,Otrakji A,Kalra MK,Xu XG,Liu B

    更新日期:2015-11-01 00:00:00

  • Oblique incidence for broad monoenergetic proton beams.

    abstract:PURPOSE:The depth dose of a monoenergetic broad parallel proton beam has been modeled in a number of ways, but evidently not yet for oblique incidence. The purpose of this investigation is to find an accurate analytic formula for this case, which can then be used to model the depth dose of a broad beam with an initial ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3495969

    authors: Jette D,Yuan J,Chen W

    更新日期:2010-11-01 00:00:00

  • Monte Carlo dosimetry for I125 and Pd103 eye plaque brachytherapy.

    abstract::A Monte Carlo study of dosimetry for eye plaque brachytherapy is performed. BrachyDose, an EGSnrc user code which makes use of Yegin's multi-geometry package, is used to fully model I125 (model 6711) and Pd103 (model 200) brachytherapy seeds and the standardized plaques of the Collaborative Ocular Melanoma Study (COMS...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3002412

    authors: Thomson RM,Taylor REP,Rogers DWO

    更新日期:2008-12-01 00:00:00

  • Development and implementation of EPID-based quality assurance tests for the small animal radiation research platform (SARRP).

    abstract:PURPOSE:Although small animal image-guided radiotherapy (SA-IGRT) systems are used increasingly in preclinical research, tools for performing routine quality assurance (QA) have not been optimized and are not readily available. Robust, efficient, and reliable QA tools are needed to ensure the accuracy and reproducibili...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12939

    authors: Anvari A,Poirier Y,Sawant A

    更新日期:2018-07-01 00:00:00

  • Deformable mapping technique to correlate lesions in digital breast tomosynthesis and automated breast ultrasound images.

    abstract:PURPOSE:To develop a deformable mapping technique to match corresponding lesions between digital breast tomosynthesis (DBT) and automated breast ultrasound (ABUS) images. METHODS:External fiducial markers were attached to the surface of two CIRS multi-modality compressible breast phantoms (A and B) containing multiple...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13113

    authors: Green CA,Goodsitt MM,Brock KK,Davis CL,Larson ED,Lau JH,Carson PL

    更新日期:2018-10-01 00:00:00

  • Using FDG-PET activity as a surrogate for tumor cell density and its effect on equivalent uniform dose calculation.

    abstract::The concept of equivalent uniform dose (EUD) has been suggested as a means to quantitatively consider heterogeneous dose distributions within targets. Tumor cell density/function is typically assumed to be uniform. We herein propose to use 18F-labeled 2-deoxyglucose (FDG) positron emission tomography (PET) tumor imagi...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1779372

    authors: Zhou SM,Wong TZ,Marks LB

    更新日期:2004-09-01 00:00:00

  • Cascaded systems analysis of shift-variant image quality in slit-scanning breast tomosynthesis.

    abstract:PURPOSE:Digital breast tomosynthesis (DBT) is becoming an important part of breast cancer screening and diagnosis. Compared to two-dimensional mammography, tomosynthesis introduces limited three-dimensional (3D) resolution, but maintains high in-plane resolution, low dose, and allows for similar clinical protocols. The...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13116

    authors: Berggren K,Cederström B,Lundqvist M,Fredenberg E

    更新日期:2018-10-01 00:00:00

  • SU-E-J-160: 4D Dynamic Arc of Non-Modulated Variable-Dose-Rate Fields for Lung SBRT: A Feasibility Study.

    abstract:PURPOSE:Conformal SBRT plans for Lung cancer with static gantry angles are ideal candidates for applying motion tracking because of: (1) better dosimetric conformity with reduced target margin and (2) easier and more faithful target tracking without intensity modulation. This work is to demonstrate that by delivering t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734998

    authors: Yi B,Yang X,Niu Y,Yu C

    更新日期:2012-06-01 00:00:00