Design, development, and implementation of the radiological physics center's pelvis and thorax anthropomorphic quality assurance phantoms.

Abstract:

:The Radiological Physics Center (RPC) developed two heterogeneous anthropomorphic quality assurance phantoms for use in verifying the accuracy of radiation delivery: one for intensity-modulated radiation therapy (IMRT) to the pelvis and the other for stereotactic body radiation therapy (SBRT) to the thorax. The purpose of this study was to describe the design and development of these two phantoms and to demonstrate the reproducibility of measurements generated with them. The phantoms were built to simulate actual patient anatomy. They are lightweight and water-fillable, and they contain imageable targets and organs at risk of radiation exposure that are of similar densities to their human counterparts. Dosimetry inserts accommodate radiochromic film for relative dosimetry and thermoluminesent dosimetry capsules for absolute dosimetry. As a part of the commissioning process, each phantom was imaged, treatment plans were developed, and radiation was delivered at least three times. Under these controlled irradiation conditions, the reproducibility of dose delivery to the target TLD in the pelvis and thorax phantoms was 3% and 0.5%, respectively. The reproducibility of radiation-field localization was less than 2.5 mm for both phantoms. Using these anthropomorphic phantoms, pelvic IMRT and thoracic SBRT radiation treatments can be verified with a high level of precision. These phantoms can be used to effectively credential institutions for participation in specific NCI-sponsored clinical trials.

journal_name

Med Phys

journal_title

Medical physics

authors

Followill DS,Evans DR,Cherry C,Molineu A,Fisher G,Hanson WF,Ibbott GS

doi

10.1118/1.2737158

subject

Has Abstract

pub_date

2007-06-01 00:00:00

pages

2070-6

issue

6

eissn

0094-2405

issn

2473-4209

journal_volume

34

pub_type

杂志文章
  • Ultra-low-dose CT image denoising using modified BM3D scheme tailored to data statistics.

    abstract:PURPOSE:It is important to enhance image quality for low-dose CT acquisitions to push the ALARA boundary. Current state-of-the-art block-matching three-dimensional (BM3D) denoising scheme assumes white Gaussian noise (WGN) model. This study proposes a novel filtering module to be incorporated into the BM3D framework fo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13252

    authors: Zhao T,Hoffman J,McNitt-Gray M,Ruan D

    更新日期:2019-01-01 00:00:00

  • X-ray imaging with amorphous selenium: optimal spectra for digital mammography.

    abstract::The optimum x-ray spectra for acquisition of digital mammographic images using an amorphous selenium (a-Se) photoconductor are investigated. The recorded images consist of latent charge distributions on the surface of an a-Se plate, which are then read out using two methods, laser discharge, or flat panel recharge. Th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597688

    authors: Fahrig R,Rowlands JA,Yaffe MJ

    更新日期:1996-04-01 00:00:00

  • Dead time of an anger camera in dual-energy-window-acquisition mode.

    abstract::Two side-by-side energy windows are sometimes employed in quantitative single photon emission computed tomography (SPECT) studies. The count-rate losses at high activities for a GE400AT camera were measured in such a dual-window-acquisition mode by imaging a decaying source composed of a hot sphere within a warm cylin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597008

    authors: Zasadny KR,Koral KF,Swailem FM

    更新日期:1993-07-01 00:00:00

  • Manual planimetric measurement of carotid plaque volume using three-dimensional ultrasound imaging.

    abstract::We investigated the utility of three manual planimetric methods to quantify carotid plaque volume. A single observer measured 15 individual plaques from 15 three-dimensional (3D) ultrasound (3D US) images of patients ten times each using three different planimetric approaches. Individual plaque volumes were measured (...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2715487

    authors: Landry A,Ainsworth C,Blake C,Spence JD,Fenster A

    更新日期:2007-04-01 00:00:00

  • L-curve analysis of radiotherapy optimization problems.

    abstract::We attempt to select an optimal value of regularization parameter in the optimization problems for intensity-modulated radiotherapy which are solved using a variational regularization technique. We apply to inverse treatment planning the L-curve method which was developed to determine the regularization parameter in t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1949750

    authors: Chvetsov AV

    更新日期:2005-08-01 00:00:00

  • Low-dose dynamic myocardial perfusion CT imaging using a motion adaptive sparsity prior.

    abstract:PURPOSE:Dynamic myocardial perfusion computed tomography (DM-PCT) imaging offers benefits over quantitative assessment of myocardial blood flow (MBF) for diagnosis and risk stratification of coronary artery disease. However, one major drawback of DM-PCT imaging is that a high radiation level is imparted by repeated sca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12285

    authors: Bian Z,Zeng D,Zhang Z,Gong C,Tian X,Yan G,Huang J,Guo H,Chen B,Zhang J,Feng Q,Chen W,Ma J

    更新日期:2017-09-01 00:00:00

  • Superiorization: an optimization heuristic for medical physics.

    abstract:PURPOSE:To describe and mathematically validate the superiorization methodology, which is a recently developed heuristic approach to optimization, and to discuss its applicability to medical physics problem formulations that specify the desired solution (of physically given or otherwise obtained constraints) by an opti...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4745566

    authors: Herman GT,Garduno E,Davidi R,Censor Y

    更新日期:2012-09-01 00:00:00

  • Evaluation of two methods of predicting MLC leaf positions using EPID measurements.

    abstract::In intensity modulated radiation treatments (IMRT), the position of the field edges and the modulation within the beam are often achieved with a multileaf collimator (MLC). During the MLC calibration process, due to the finite accuracy of leaf position measurements, a systematic error may be introduced to leaf positio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2335490

    authors: Parent L,Seco J,Evans PM,Dance DR,Fielding A

    更新日期:2006-09-01 00:00:00

  • A strategy to decrease partial scan reconstruction artifacts in myocardial perfusion CT: phantom and in vivo evaluation.

    abstract:PURPOSE:Partial scan reconstruction (PSR) artifacts are present in myocardial perfusion imaging using dynamic multidetector computed tomography (MDCT). PSR artifacts appear as temporal CT number variations due to inconsistencies in the angular data range used to reconstruct images and compromise the quantitative value ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3665767

    authors: Ramirez-Giraldo JC,Yu L,Kantor B,Ritman EL,McCollough CH

    更新日期:2012-01-01 00:00:00

  • Poster - Thur Eve - 64: Evaluation of SmartArc and RapidArc for lung SBRT treatment planning and delivery.

    abstract:OBJECTIVES:To evaluate the performance of RapidArc® (Eclipse 10.0.28) and SmartArc® (Pinnacle 9.0) radiotherapy plans for lung stereotactic body radiation therapy (SBRT) in terms of dosimetric plan quality, delivery efficiency, inhomogeneity corrections and accuracy of dose delivery using a custom-built heterogeneity i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740172

    authors: Fakir H,Hoover D,Chen JZ

    更新日期:2012-07-01 00:00:00

  • Computation of beam quality parameters for Mo/Mo, Mo/Rh, Rh/Rh, and W/Al target/filter combinations in mammography.

    abstract::A computer program was implemented to predict mammography x-ray beam parameters in the range 20-40 kV for Mo/Mo, Mo/Rh, Rh/Rh, and W/Al target/filter combinations. The computation method used to simulate mammography x-ray spectra is based on the Boone et al. model. The beam quality parameters such as the half-value la...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1608498

    authors: Kharrati H,Zarrad B

    更新日期:2003-10-01 00:00:00

  • Fast IMRT with narrow high energy scanned photon beams.

    abstract:PURPOSE:Since the first publications on intensity modulated radiation therapy (IMRT) in the early 1980s almost all efforts have been focused on fairly time consuming dynamic or segmental multileaf collimation. With narrow fast scanned photon beams, the flexibility and accuracy in beam shaping increases, not least in co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3615059

    authors: Andreassen B,Strååt SJ,Holmberg R,Näfstadius P,Brahme A

    更新日期:2011-08-01 00:00:00

  • An improved electron energy-loss straggling algorithm for Monte Carlo transport codes.

    abstract::The commonly used Blunck and Leisegang electron energy-loss distribution falls off too rapidly with increasing energy loss. Also, for large thicknesses and/or low-Z media, where their distribution should approach Landau's, it normalizes to 0.92 rather than 1.0, it overestimates the number of very small energy-loss eve...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595500

    authors: Weinhous MS,Nath R

    更新日期:1984-05-01 00:00:00

  • Long term variation in beam symmetry as a function of gantry angle for a computer-controlled linear accelerator.

    abstract::Testing computer-controlled linear accelerators for patient safety and proper patient dose delivery requires that certain beam characteristics be monitored over an extended period of time. Computer-controlled conformal radiation therapy using asymmetric collimator jaw settings necessitates stable symmetric treatment b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596363

    authors: Loyd MD,Lane RG,Laxton J,Chow CH,Rosen II

    更新日期:1989-07-01 00:00:00

  • Technical and dosimetric realization of in vivo x-ray microbeam irradiations at the Munich Compact Light Source.

    abstract:PURPOSE:X-ray microbeam radiation therapy is a preclinical concept for tumor treatment promising tissue sparing and enhanced tumor control. With its spatially separated, periodic micrometer-sized pattern, this method requires a high dose rate and a collimated beam typically available at large synchrotron radiation faci...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14433

    authors: Burger K,Urban T,Dombrowsky AC,Dierolf M,Günther B,Bartzsch S,Achterhold K,Combs SE,Schmid TE,Wilkens JJ,Pfeiffer F

    更新日期:2020-10-01 00:00:00

  • Quantitative study of focused ultrasound enhanced doxorubicin delivery to prostate tumor in vivo with MRI guidance.

    abstract:PURPOSE:The purpose of this study was to investigate the potential of MR-guided pulsed focused ultrasound (pFUS) for the enhancement of drug uptake in prostate tumors in vivo using doxorubicin (Dox). METHODS:An antitumor drug Dox, an orthotopic animal prostate tumor model using human prostate cancer, LNCaP cell line, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4705346

    authors: Chen X,Cvetkovic D,Ma CM,Chen L

    更新日期:2012-05-01 00:00:00

  • Objected constrained registration and manifold learning: a new patient setup approach in image guided radiation therapy of thoracic cancer.

    abstract:PURPOSE:The management of thoracic malignancies with radiation therapy is complicated by continuous target motion. In this study, a real time motion analysis approach is proposed to improve the accuracy of patient setup. METHODS:For 11 lung cancer patients a long training fluoroscopy was acquired before the first trea...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.4794489

    authors: Chen T,Jabbour SK,Qin S,Haffty BG,Yue N

    更新日期:2013-04-01 00:00:00

  • Recent progress in x-ray stereoscopes.

    abstract::An improved reconstructed stereoscopic x-ray image display system, based on the principle of binocular parallax, is described. Pulse-synchronized operation of two triode x-ray tubes and one plumbicon TV camera is employed to separate the left and right images for presentation to the two eyes, respectively. The princip...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595365

    authors: Zhang S,King PH,Pang XD

    更新日期:1983-09-01 00:00:00

  • Phantom size in brachytherapy source dosimetric studies.

    abstract::An important point to consider in a brachytherapy dosimetry study is the phantom size involved in calculations or experimental measurements. As pointed out by Williamson [Med. Phys. 18, 776-786 (1991)] this topic has a relevant influence on final dosimetric results. Presently, one-dimensional (1-D) algorithms and newl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1759826

    authors: Pérez-Calatayud J,Granero D,Ballester F

    更新日期:2004-07-01 00:00:00

  • Towards Data-Efficient Learning: A Benchmark for COVID-19 CT Lung and Infection Segmentation.

    abstract:PURPOSE:Accurate segmentation of lung and infection in COVID-19 computed tomography (CT) scans plays an important role in the quantitative management of patients. Most of the existing studies are based on large and private annotated datasets that are impractical to obtain from a single institution, especially when radi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14676

    authors: Ma J,Wang Y,An X,Ge C,Yu Z,Chen J,Zhu Q,Dong G,He J,He Z,Cao T,Zhu Y,Nie Z,Yang X

    更新日期:2020-12-23 00:00:00

  • System considerations in CCD-based x-ray imaging for digital chest radiography and digital mammography.

    abstract::System modeling is used to investigate the effect of various system parameters on the image quality in CCD-based x-ray imaging systems. The systems considered consist of a typical phosphor-based scintillating screen coupled to a CCD through lens or fiberoptic taper. Two applications, chest radiography and mammography,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598072

    authors: Hejazi S,Trauernicht DP

    更新日期:1997-02-01 00:00:00

  • SU-E-T-178: Optically Stimulated Luminescence (OSL) Dosimetry: A Study of A-Al2O3:C Assessed by PENELOPE Monte Carlo Simulation.

    abstract:PURPOSE:To use the Monte Carlo code PENELOPE to study attenuation and tissue equivalence properties of a-Al2O3:C for OSL dosimetry. METHODS:Mass attenuation coefficients of α-Al2O3 and α-Al2O3:C with carbon percent weight concentrations from 1% to 150% were simulated with PENELOPE Monte Carlo code and compared to mass...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735237

    authors: Nicolucci P,Schuch F

    更新日期:2012-06-01 00:00:00

  • Dental enamel as an in vivo radiation dosimeter.

    abstract::The determination of the radiation exposure history of the population has become increasingly important in the study of the effects of low-level radiation. The present work was started to try to obtain an in vivo dosimeter that could give an indication of radiation exposure. Dental enamel is the only living tissue whi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595768

    authors: Pass B,Aldrich JE

    更新日期:1985-05-01 00:00:00

  • Effect of patient support pads on image quality and dose in fluoroscopy.

    abstract::An investigation was performed of the changes in image quality and patient dose as a result of increasing filtration for fluoroscopy performed under automatic brightness control. Filtration was added either at the x-ray tube housing (i.e., scatter-free geometry) or adjacent to a tissue equivalent phantom simulating th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597906

    authors: Geiser WR,Huda W,Gkanatsios NA

    更新日期:1997-03-01 00:00:00

  • Low-dose cone-beam CT via raw counts domain low-signal correction schemes: Performance assessment and task-based parameter optimization (Part II. Task-based parameter optimization).

    abstract:PURPOSE:Different low-signal correction (LSC) methods have been shown to efficiently reduce noise streaks and noise level in CT to provide acceptable images at low-radiation dose levels. These methods usually result in CT images with highly shift-variant and anisotropic spatial resolution and noise, which makes the par...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12855

    authors: Gomez-Cardona D,Hayes JW,Zhang R,Li K,Cruz-Bastida JP,Chen GH

    更新日期:2018-05-01 00:00:00

  • Ethics and professionalism in medical physics: a survey of AAPM members.

    abstract:PURPOSE:To assess current education, practices, attitudes, and perceptions pertaining to ethics and professionalism in medical physics. METHODS:A link to a web-based survey was distributed to the American Association of Physicists in Medicine (AAPM) e-mail membership list, with a follow-up e-mail sent two weeks later....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4797463

    authors: Ozturk N,Armato SG 3rd,Giger ML,Serago CF,Ross LF

    更新日期:2013-04-01 00:00:00

  • An experimentally validated couch and MLC tracking simulator used to investigate hybrid couch-MLC tracking.

    abstract:PURPOSE/OBJECTIVE:Couch and MLC tracking are two novel techniques to mitigate intrafractional tumor motion on a conventional linear accelerator, but both techniques still have residual dosimetric errors. Here, we first propose and experimentally validate a software tool to simulate couch and MLC tracking, and then use ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12104

    authors: Toftegaard J,Hansen R,Ravkilde T,Macek K,Poulsen PR

    更新日期:2017-03-01 00:00:00

  • Suitability of laser stimulated TLD arrays as patient dose monitors in high dose x-ray imaging.

    abstract::Skin entrance doses of patients undergoing interventional x-ray procedures are capable of causing skin damage and should be monitored routinely. Single TLD chips are not suitable because the location of maximum skin exposure cannot be predicted. Most photographic films are too sensitive at diagnostic x-ray energies fo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597973

    authors: Geise RA,Schueler BA,Lien W,Jones SC

    更新日期:1997-10-01 00:00:00

  • Efficient low-dose CT artifact mitigation using an artifact-matched prior scan.

    abstract:PURPOSE:Low-dose CT has attracted increasing attention due to growing concerns about radiation exposure in medical scans. However, the frugal use of x-ray radiation inevitably reduces the quality of the CT images, introducing artifacts such as noise and streaks which make the reconstructed images difficult to read in c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736528

    authors: Xu W,Mueller K

    更新日期:2012-08-01 00:00:00

  • A Monte Carlo approach to validation of FFF VMAT treatment plans for the TrueBeam linac.

    abstract:PURPOSE:To commission and benchmark a vendor-supplied (Varian Medical Systems) Monte Carlo phase-space data for the 6 MV flattening filter free (FFF) energy mode on a TrueBeam linear accelerator for the purpose of quality assurance of clinical volumetric modulated arc therapy (VMAT) treatment plans. A method for render...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4773883

    authors: Gete E,Duzenli C,Milette MP,Mestrovic A,Hyde D,Bergman AM,Teke T

    更新日期:2013-02-01 00:00:00