Abstract:
PURPOSE:The management of thoracic malignancies with radiation therapy is complicated by continuous target motion. In this study, a real time motion analysis approach is proposed to improve the accuracy of patient setup. METHODS:For 11 lung cancer patients a long training fluoroscopy was acquired before the first treatment, and multiple short testing fluoroscopies were acquired weekly at the pretreatment patient setup of image guided radiotherapy (IGRT). The data analysis consisted of three steps: first a 4D target motion model was constructed from 4DCT and projected to the training fluoroscopy through deformable registration. Then the manifold learning method was used to construct a 2D subspace based on the target motion (kinetic) and location (static) information in the training fluoroscopy. Thereafter the respiratory phase in the testing fluoroscopy was determined by finding its location in the subspace. Finally, the phase determined testing fluoroscopy was registered to the corresponding 4DCT to derive the pretreatment patient position adjustment for the IGRT. The method was tested on clinical image sets and numerical phantoms. RESULTS:The registration successfully reconstructed the 4D motion model with over 98% volume similarity in 4DCT, and over 95% area similarity in the training fluoroscopy. The machine learning method derived the phase values in over 98% and 93% test images of the phantom and patient images, respectively, with less than 3% phase error. The setup approach achieved an average accumulated setup error less than 1.7 mm in the cranial-caudal direction and less than 1 mm in the transverse plane. All results were validated against the ground truth of manual delineations by an experienced radiation oncologist. The expected total time for the pretreatment setup analysis was less than 10 s. CONCLUSIONS:By combining the registration and machine learning, the proposed approach has the potential to improve the accuracy of pretreatment setup for patients with thoracic malignancy.
journal_name
Med Physjournal_title
Medical physicsauthors
Chen T,Jabbour SK,Qin S,Haffty BG,Yue Ndoi
10.1118/1.4794489subject
Has Abstractpub_date
2013-04-01 00:00:00pages
041710issue
4eissn
0094-2405issn
2473-4209journal_volume
40pub_type
临床试验,杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:By means of Monte Carlo (MC) simulations and indirect measurements, we have evaluated the maximum dose rates achievable with conventional x-ray tubes and related them to FLASH therapy dose rates of >40 Gy/s. METHODS:Monte Carlo models of two 160 kV x-ray tubes, the 3-kW MXR-160/22 and the 6-kW MXR-165, were bu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13858
更新日期:2019-12-01 00:00:00
abstract::This paper deals with methods of reducing the total time required to acquire the projection data for a set of contiguous computed tomography (CT) images. Normally during the acquisition of a set of slices, the patient is held stationary during data collection and translated to the next axial location during an intersc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596464
更新日期:1990-11-01 00:00:00
abstract:PURPOSE:Computed tomography (CT) intrascanner and interscanner variability has not been well characterized. Thus, the purpose of this study was to examine the within-run, between-run, and between-scanner precision of physical dosimetry-related measurements collected over the course of 1 yr on three different makes and ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3426000
更新日期:2010-08-01 00:00:00
abstract:PURPOSE:The biologically effective dose (BED) of temporary brachytherapy treatments is a function of both chosen radionuclide (R) and implant duration (T). This study endeavored to evaluate BED delivered to the tumor volume and surrounding ocular structures as a function of plaque position (P), prescription dose, R, an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735548
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:In this work, the fabrication, operation, and evaluation of a probe-format graphite calorimeter - herein referred to as Aerrow - as an absolute clinical dosimeter of high-energy photon beams while in the presence of a B = 1.5 T magnetic field is described. Comparable to a cylindrical ionization chamber (IC) in ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13968
更新日期:2020-03-01 00:00:00
abstract::Total scalp irradiation is a treatment technique used for a variety of superficial malignancies. Helical tomotherapy is an effective technique used for total scalp irradiation. Recent published work has shown the TomoTherapy planning system to overestimate the superficial dose. In this study, the superficial doses for...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2996288
更新日期:2008-11-01 00:00:00
abstract::One limitation to the widespread implementation of Monte Carlo (MC) patient dose-calculation algorithms for radiotherapy is the lack of a general and accurate source model of the accelerator radiation source. Our aim in this work is to investigate the sensitivity of the photon-beam subsource distributions in a MC sour...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1884385
更新日期:2005-04-01 00:00:00
abstract::This study concerns the accuracy and precision of the IAEA/WHO LiF TLD system used in intercomparison by mail of absorbed doses from 60Co gamma-radiation and 4-25 MV x rays. The system employs 160 mg LiF powder in polystyrene capsules, which are placed at 5 or 7 cm depth in water and irradiated to doses close to 200 r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594746
更新日期:1980-09-01 00:00:00
abstract:PURPOSE:Current on-board imaging systems commonly used by modern linear accelerators (LINACs) have a limited field of view (FOV) for a cone-beam CT (CBCT) scan, which is typically less than 50 cm. Consequently, truncation artifacts often occur for large patients. The goal of this work is to investigate a novel method t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3514130
更新日期:2010-12-01 00:00:00
abstract::We have measured the linearity, spatial resolution (MTF), noise (NPS), and signal-to-noise characteristics (DQE) of an electronic portal imaging device (EPID) based on an amorphous silicon flat-panel array. The array has a 128 x 128-pixel matrix and each pixel is 0.75 x 0.75 mm2 in dimension so the array covers an are...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598252
更新日期:1998-05-01 00:00:00
abstract::This paper is concerned with the proposed Birmingham accelerator-based epithermal neutron beam for boron neutron capture therapy (BNCT). In particular, the option of producing a therapy beam at an orthogonal direction to the incoming protons is considered. Monte Carlo radiation transport simulations, both with and wit...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598479
更新日期:1999-01-01 00:00:00
abstract:PURPOSE:To compare and evaluate intensity-based registration methods for computation of serial x-ray mammogram correspondence. METHODS:X-ray mammograms were simulated from MRIs of 20 women using finite element methods for modeling breast compressions and employing a MRI/x-ray appearance change model. The parameter con...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3457470
更新日期:2010-09-01 00:00:00
abstract:PURPOSE:The efficiency of radioembolization procedures could be greatly enhanced if results of the 99m Tc-MAA pretreatment procedure were immediately available in the interventional suite, enabling 1-day procedures as a result of direct estimation of the hepatic radiation dose and lung shunt fraction. This would, howev...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13253
更新日期:2019-01-01 00:00:00
abstract::Breast density is a strong predictor of the failure of mammography screening to detect breast cancer and is a strong predictor of the risk of developing breast cancer. The many imaging options that are now available for imaging dense breasts show great promise, but there is still the question of determining which wome...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.4935141
更新日期:2015-12-01 00:00:00
abstract::The purpose of this paper is to examine the thermal dose distribution, to configure the optimal absorbed power deposition, and to design an appropriate heating strategy for ultrasound thermal therapy. This work employs simulation programs, which are based on the transient bio-heat transfer equation and an ideal absorb...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1406516
更新日期:2001-10-01 00:00:00
abstract:PURPOSE:Very fast Monte Carlo (MC) simulations of proton transport have been implemented recently on graphics processing units (GPUs). However, these MCs usually use simplified models for nonelastic proton-nucleus interactions. Our primary goal is to build a GPU-based proton transport MC with detailed modeling of elast...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4921046
更新日期:2015-06-01 00:00:00
abstract:PURPOSE:Researchers write many computer programs with unique implementations, usually requiring a great amount of effort for other researchers to learn how to install, configure, and use. Some programs require specialized hardware platforms such as GPU workstation or CPU cluster, which may not readily available for man...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735274
更新日期:2012-06-01 00:00:00
abstract::Both the design considerations and the dosimetric properties of the Siemens Model 5800 linear accelerator are discussed. This unit is of such an energy (3.3 MV) as to imitate Cobalt-60 teletherapy depth doses. A linear relation of dmax to depth dose at low energies was found for various wave guides and targets. The en...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596487
更新日期:1990-05-01 00:00:00
abstract::It is shown that predictions can be made of scatter-to-primary ratios for a variety of mammographic configurations. The different configurations can be produced by changes in source-detector distance; source-phantom distance; air gap; photon energy; phantom composition, thickness, and cross-sectional area. A detailed ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595807
更新日期:1986-11-01 00:00:00
abstract:PURPOSE:Target localization accuracy of cone-beam CT (CBCT) images used in radiation treatment of respiratory disease sites is affected by motion artifacts (blurring and streaking). The authors have previously reported on a method of respiratory motion correction in thoracic CBCT at end expiration (EE). The previous re...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4896101
更新日期:2014-10-01 00:00:00
abstract::Current edge detection methods used to determine coronary artery dimensions from digital (DSA) images suffer a strong dependence on the system's modulation transfer function (MTF). The videodensitometric algorithms are less sensitive to MTF blurring, yet still result in an overestimation of the vessel size of 10% to 2...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596370
更新日期:1989-03-01 00:00:00
abstract::Interchange or transfer of radiographic techniques through measurement of penetration quality is discussed. The usefulness of this achievement is verified using an aluminum step wedge. Also, the procedure described provides a method for performance evaluation of kVp compensation on diagnostic x-ray installations. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594156
更新日期:1975-01-01 00:00:00
abstract:PURPOSE:Respiratory gating in PET is an approach used to minimize the negative effects of respiratory motion on spatial resolution. It is based on an initial determination of a patient's respiratory movements during a scan, typically using hardware based systems. In recent years, several fully automated databased algor...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3483784
更新日期:2010-10-01 00:00:00
abstract:PURPOSE:Anomalous pixels may be defined as those pixels whose exposure response relationship is deviant from the typical, expected or calibrated response. A group of anomalous pixels may Result in visible correlated artifacts. Here we demonstrate an approach to identify anomalous pixels and correlated artifacts using f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734820
更新日期:2012-06-01 00:00:00
abstract::The most favorable treatment for moving body anatomy should aim at utilizing organ motion to minimize the dose to sensitive structures without compromising the dose delivered to the target. The solution of the problem of appropriate intensity redistribution over different phases of body motion is achievable in dynamic...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.2804722
更新日期:2007-12-01 00:00:00
abstract:PURPOSE:Cardiac motion is typically not accounted for during pretreatment imaging for central lung and mediastinal tumors. However, cardiac induced tumor motion averages 5.8 mm for esophageal tumors and 3-5 mm for some lung tumors, which can result in positioning errors. Our aim is to reduce both cardiac- and respirato...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13670
更新日期:2019-09-01 00:00:00
abstract:PURPOSE:The purpose of this work is twofold: First, to characterize the artifacts occurring in helical 4D-CT imaging; second, to propose a method that can automatically identify the artifacts in 4D-CT images. The authors have designed a process that can automatically identify the artifacts in 4D-CT images, which may be...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3553556
更新日期:2011-04-01 00:00:00
abstract::Seeds containing radioactive Ytterbium-169 (169Yb) have recently been manufactured for possible application to brachytherapy. Ytterbium-169 emits photons with an average energy of 93 keV (excluding energies less than 10 keV), and decays with a half-life of 32 days. Analytic and Monte Carlo computations have been used ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596813
更新日期:1992-05-01 00:00:00
abstract::Mammography is the most effective method for breast cancer screening available today. However, the low positive predictive value of breast biopsy resulting from mammogram interpretation leads to approximately 70% unnecessary biopsies with benign outcomes. To reduce the high number of unnecessary breast biopsies, sever...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2786864
更新日期:2007-11-01 00:00:00
abstract::The relative sensitivity of the half-value layer (HVL) method as a quality index for megavoltage x-ray beams is examined by theoretical calculation and experimental measurements for 4-, 6-, 10-, and 25-MV x-ray beams. It is shown that lower atomic number materials are more sensitive to beam quality changes than higher...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595794
更新日期:1985-01-01 00:00:00