A new fast and fully automated software based algorithm for extracting respiratory signal from raw PET data and its comparison to other methods.

Abstract:

PURPOSE:Respiratory gating in PET is an approach used to minimize the negative effects of respiratory motion on spatial resolution. It is based on an initial determination of a patient's respiratory movements during a scan, typically using hardware based systems. In recent years, several fully automated databased algorithms have been presented for extracting a respiratory signal directly from PET data, providing a very practical strategy for implementing gating in the clinic. In this work, a new method is presented for extracting a respiratory signal from raw PET sinogram data and compared to previously presented automated techniques. METHODS:The acquisition of respiratory signal from PET data in the newly proposed method is based on rebinning the sinogram data into smaller data structures and then analyzing the time activity behavior in the elements of these structures. From this analysis, a 1D respiratory trace is produced, analogous to a hardware derived respiratory trace. To assess the accuracy of this fully automated method, respiratory signal was extracted from a collection of 22 clinical FDG-PET scans using this method, and compared to signal derived from several other software based methods as well as a signal derived from a hardware system. RESULTS:The method presented required approximately 9 min of processing time for each 10 min scan (using a single 2.67 GHz processor), which in theory can be accomplished while the scan is being acquired and therefore allowing a real-time respiratory signal acquisition. Using the mean correlation between the software based and hardware based respiratory traces, the optimal parameters were determined for the presented algorithm. The mean/median/range of correlations for the set of scans when using the optimal parameters was found to be 0.58/0.68/0.07-0.86. The speed of this method was within the range of real-time while the accuracy surpassed the most accurate of the previously presented algorithms. CONCLUSIONS:PET data inherently contains information about patient motion; information that is not currently being utilized. We have shown that a respiratory signal can be extracted from raw PET data in potentially real-time and in a fully automated manner. This signal correlates well with hardware based signal for a large percentage of scans, and avoids the efforts and complications associated with hardware. The proposed method to extract a respiratory signal can be implemented on existing scanners and, if properly integrated, can be applied without changes to routine clinical procedures.

journal_name

Med Phys

journal_title

Medical physics

authors

Kesner AL,Kuntner C

doi

10.1118/1.3483784

subject

Has Abstract

pub_date

2010-10-01 00:00:00

pages

5550-9

issue

10

eissn

0094-2405

issn

2473-4209

journal_volume

37

pub_type

杂志文章
  • Efficient generation of a magnetic field-free line.

    abstract:PURPOSE:Signal encoding in magnetic particle imaging (MPI) is achieved by moving a field-free point (FFP) through the region of interest. One way to increase the sensitivity of the method is to scan the region of interest with a field-free line (FFL) instead of the FFP. Recently, the first feasible FFL coil setup was i...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.3447726

    authors: Knopp T,Erbe M,Biederer S,Sattel TF,Buzug TM

    更新日期:2010-07-01 00:00:00

  • Rotationally resliced 3D prostate TRUS segmentation using convex optimization with shape priors.

    abstract:PURPOSE:Efficient and accurate segmentations of 3D end-firing transrectal ultrasound (TRUS) images play an important role in planning of 3D TRUS guided prostate biopsy. However, poor image quality of the input 3D TRUS images, such as strong imaging artifacts and speckles, often makes it a challenging task to extract th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4906129

    authors: Qiu W,Yuan J,Ukwatta E,Fenster A

    更新日期:2015-02-01 00:00:00

  • Strategies for scatter correction in dual source CT.

    abstract:PURPOSE:Dual source CT (DSCT) systems utilize two measurement systems (A) and (B) offset by about 90 degrees. A special challenge in DSCT is cross-scattered radiation, i.e., scattered radiation from x-ray tube (B) detected in detector (A) and vice versa. Cross-scattered radiation can produce artifacts and degrade the c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3504606

    authors: Petersilka M,Stierstorfer K,Bruder H,Flohr T

    更新日期:2010-11-01 00:00:00

  • Three-dimensional dose reconstruction of breast cancer treatment using portal imaging.

    abstract::In this study, we present an algorithm for three-dimensional (3-D) dose reconstruction using portal images obtained with an electronic portal imaging device (EPID). For this purpose an algorithm for 2-D dose reconstruction, which was previously developed in our institution, was adapted. The external contour of the pat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1589496

    authors: Louwe RJ,Damen EM,van Herk M,Minken AW,Törzsök O,Mijnheer BJ

    更新日期:2003-09-01 00:00:00

  • Variability of tumor area measurements for response assessment in malignant pleural mesothelioma.

    abstract:PURPOSE:The measurement of malignant pleural mesothelioma is critical to the assessment of tumor response to therapy. Current response assessment standards utilize summed linear measurements acquired on three computed tomography (CT) sections. The purpose of this study was to evaluate manual area measurements as an alt...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4810940

    authors: Labby ZE,Straus C,Caligiuri P,MacMahon H,Li P,Funaki A,Kindler HL,Armato SG 3rd

    更新日期:2013-08-01 00:00:00

  • Effect of longitudinal magnetic fields on a simulated in-line 6 MV linac.

    abstract:PURPOSE:Linac-magnetic resonance (MR) systems have been proposed in order to achieve realtime image guided radiotherapy. The design of a new linac-MR system with the in-line 6 MV linac generating x-rays along the symmetry axis of an open MR imager is outlined. This new design allows for a greater MR field strength to a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3481513

    authors: St Aubin J,Santos DM,Steciw S,Fallone BG

    更新日期:2010-09-01 00:00:00

  • Dose in the buildup region outside the primary beam.

    abstract::The dose received in the buildup region outside the primary beam has been measured for 60Co gamma rays and 6- and 18-MV X rays. The variation of this dose with field size and depth was evaluated. The effect of blocking trays and the importance of their design was determined. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595508

    authors: Horton JL

    更新日期:1984-05-01 00:00:00

  • A new technique to characterize CT scanner bow-tie filter attenuation and applications in human cadaver dosimetry simulations.

    abstract:PURPOSE:To present a noninvasive technique for directly measuring the CT bow-tie filter attenuation with a linear array x-ray detector. METHODS:A scintillator based x-ray detector of 384 pixels, 307 mm active length, and fast data acquisition (model X-Scan 0.8c4-307, Detection Technology, FI-91100 Ii, Finland) was use...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4932364

    authors: Li X,Shi JQ,Zhang D,Singh S,Padole A,Otrakji A,Kalra MK,Xu XG,Liu B

    更新日期:2015-11-01 00:00:00

  • Application of solid state detectors for dosimetry of therapeutic proton beams.

    abstract::A PTW Riga diamond detector and LiF TLDs have been evaluated for use in proton beam dosimetry by comparing results of proton beam calibration with those obtained using thimble ionization chambers. The thimble ionization chambers were calibrated in terms of exposure while the TLDs and diamond detector were calibrated i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597608

    authors: Vatnitsky S,Miller D,Siebers J,Moyers M

    更新日期:1995-04-01 00:00:00

  • Influence of phantom diameter, kVp and scan mode upon computed tomography dose index.

    abstract::The computed tomography (CT) radiation dose to pediatric patients has received considerable attention recently. Moreover, it is important to be able to determine CT radiation doses for various patient sizes ranging from infants to large adults. The current AAPM protocol only measures CT radiation dose using a 16 cm ac...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1543149

    authors: Nickoloff EL,Dutta AK,Lu ZF

    更新日期:2003-03-01 00:00:00

  • Integration of optical imaging with a small animal irradiator.

    abstract:PURPOSE:The authors describe the integration of optical imaging with a targeted small animal irradiator device, focusing on design, instrumentation, 2D to 3D image registration, 2D targeting, and the accuracy of recovering and mapping the optical signal to a 3D surface generated from the cone-beam computed tomography (...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4894730

    authors: Weersink RA,Ansell S,Wang A,Wilson G,Shah D,Lindsay PE,Jaffray DA

    更新日期:2014-10-01 00:00:00

  • An experimentally validated couch and MLC tracking simulator used to investigate hybrid couch-MLC tracking.

    abstract:PURPOSE/OBJECTIVE:Couch and MLC tracking are two novel techniques to mitigate intrafractional tumor motion on a conventional linear accelerator, but both techniques still have residual dosimetric errors. Here, we first propose and experimentally validate a software tool to simulate couch and MLC tracking, and then use ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12104

    authors: Toftegaard J,Hansen R,Ravkilde T,Macek K,Poulsen PR

    更新日期:2017-03-01 00:00:00

  • Gafchromic EBT2 film dosimetry in reflection mode with a novel plan-based calibration method.

    abstract:PURPOSE:A dosimetric system formed by Gafchromic EBT2 radiochromic film and Epson Expression 10000XL flatbed scanner was commissioned for dosimetry. In this paper, several open questions concerning the commissioning of radiochromic films for dosimetry were addressed: (a) is it possible to employ this dosimetric system ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4772075

    authors: Mendez I,Hartman V,Hudej R,Strojnik A,Casar B

    更新日期:2013-01-01 00:00:00

  • The physics of cancer therapy with negative pions.

    abstract::The introduction of negative pions into cancer therapy has required the construction of large new proton accelerators together with special magnetic systems to form and direct the pion beam to a patient. A summary is presented of the fundamental properties of pions and of the methods used to study the therapeutic beam...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.594868

    authors: Richman C

    更新日期:1981-05-01 00:00:00

  • Iterative reconstruction method for light emitting sources based on the diffusion equation.

    abstract::Bioluminescent imaging (BLI) of luciferase-expressing cells in live small animals is a powerful technique for investigating tumor growth, metastasis, and specific biological molecular events. Three-dimensional imaging would greatly enhance applications in biomedicine since light emitting cell populations could be unam...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2138007

    authors: Slavine NV,Lewis MA,Richer E,Antich PP

    更新日期:2006-01-01 00:00:00

  • On charged particle equilibrium violation in external photon fields.

    abstract:PURPOSE:In a recent paper by Bouchard et al. [Med. Phys. 36(10), 4654-4663 (2009)], a theoretical model of quality correction factors for idealistic so-called plan-class specific reference (PCSR) fields was proposed. The reasoning was founded on the definition of PCSR fields made earlier by Alfonso et al. [Med. Phys. 3...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3684952

    authors: Bouchard H,Seuntjens J,Palmans H

    更新日期:2012-03-01 00:00:00

  • JADA: a graphical user interface for comprehensive internal dose assessment in nuclear medicine.

    abstract:PURPOSE:The main objective of this work was to design a comprehensive dosimetry package that would keep all aspects of internal dose calculation within the framework of a single software environment and that would be applicable for a variety of dose calculation approaches. METHODS:Our MATLAB-based graphical user inter...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4810963

    authors: Grimes J,Uribe C,Celler A

    更新日期:2013-07-01 00:00:00

  • A Novel method to generate on-board 4D MRI using prior 4D MRI and on-board kV projections from a conventional LINAC for target localization in liver SBRT.

    abstract:PURPOSE:On-board MRI can provide superb soft tissue contrast for improving liver SBRT localization. However, the availability of on-board MRI in clinics is extremely limited. On the contrary, on-board kV imaging systems are widely available on radiotherapy machines, but its capability to localize tumors in soft tissue ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12998

    authors: Harris W,Wang C,Yin FF,Cai J,Ren L

    更新日期:2018-07-01 00:00:00

  • Improved dynamic-programming-based algorithms for segmentation of masses in mammograms.

    abstract::In this paper, two new boundary tracing algorithms for segmentation of breast masses are presented. These new algorithms are based on the dynamic programming-based boundary tracing (DPBT) algorithm proposed in Timp and Karssemeijer, [S. Timp and N. Karssemeijer, Med. Phys. 31, 958-971 (2004)] The DPBT algorithm contai...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2791034

    authors: Rojas Domínguez A,Nandi AK

    更新日期:2007-11-01 00:00:00

  • Low-dose dynamic myocardial perfusion CT imaging using a motion adaptive sparsity prior.

    abstract:PURPOSE:Dynamic myocardial perfusion computed tomography (DM-PCT) imaging offers benefits over quantitative assessment of myocardial blood flow (MBF) for diagnosis and risk stratification of coronary artery disease. However, one major drawback of DM-PCT imaging is that a high radiation level is imparted by repeated sca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12285

    authors: Bian Z,Zeng D,Zhang Z,Gong C,Tian X,Yan G,Huang J,Guo H,Chen B,Zhang J,Feng Q,Chen W,Ma J

    更新日期:2017-09-01 00:00:00

  • Thermoluminescent dosimetry of the SourceTech Medical model STM1251 125I seed.

    abstract::Many new models of 125I seeds are being introduced, mainly due to the increase in prostate seed implants. We have evaluated the SourceTech Medical (STM), model STM1251, 125I seed using thermoluminescent dosimeters (TLDs) in a solid water phantom. TLD cubes, LiF TLD-100, with dimension 1 mm on each edge, were irradiate...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1577251

    authors: Chiu-Tsao ST,Duckworth TL,Hsiung CY,Li Z,Williamson J,Patel NS,Harrison LB

    更新日期:2003-07-01 00:00:00

  • Best estimate of luminal cross-sectional area of coronary arteries from angiograms.

    abstract::We have reexamined the problem of estimating the luminal area of an elliptically shaped coronary artery cross section from two or more radiographic diameter measurements. The expected error is found to be much smaller than the maximum potential error. In the cases of two orthogonal views, closed form expressions have ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596296

    authors: Lee PL,Selzer RH

    更新日期:1988-07-01 00:00:00

  • MO-A-217BCD-01: Internal Emitter Dose Estimation.

    abstract::Tissue absorbed dose (D) is a computed result for internal emitters. For fixed geometries, D is calculated by a matrix (S) multiplication of the integrated activity vector (Ã). The last quantity is usually measured by nuclear imaging of activity in various source organs and performing a temporal integration. Ã is the ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735750

    authors: Williams L

    更新日期:2012-06-01 00:00:00

  • Daily check instrument for photon and electron beam quality assurance of medical linacs.

    abstract::An instrument for daily beam checks of medical accelerators is described. Using three silicon diodes, the instrument provides information about calibration, beam symmetry, flatness, and energy variation for both photon and electron beams. Operating characteristics of the instrument and the electronic circuit design pe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595756

    authors: Lutz WR,Maddox BJ,Kase KR

    更新日期:1985-07-01 00:00:00

  • Computerized analysis of mammographic microcalcifications in morphological and texture feature spaces.

    abstract::We are developing computerized feature extraction and classification methods to analyze malignant and benign microcalcifications on digitized mammograms. Morphological features that described the size, contrast, and shape of microcalcifications and their variations within a cluster were designed to characterize microc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598389

    authors: Chan HP,Sahiner B,Lam KL,Petrick N,Helvie MA,Goodsitt MM,Adler DD

    更新日期:1998-10-01 00:00:00

  • Ideal-observer detectability in photon-counting differential phase-contrast imaging using a linear-systems approach.

    abstract:PURPOSE:To provide a cascaded-systems framework based on the noise-power spectrum (NPS), modulation transfer function (MTF), and noise-equivalent number of quanta (NEQ) for quantitative evaluation of differential phase-contrast imaging (Talbot interferometry) in relation to conventional absorption contrast under equal-...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4739195

    authors: Fredenberg E,Danielsson M,Stayman JW,Siewerdsen JH,Aslund M

    更新日期:2012-09-01 00:00:00

  • Nine-degrees-of-freedom flexmap for a cone-beam computed tomography imaging device with independently movable source and detector.

    abstract:PURPOSE:Couch-mounted cone-beam computed tomography (CBCT) imaging devices with independently rotatable x-ray source and flat-panel detector arms for acquisitions of arbitrary regions of interest (ROI) have recently been introduced in image-guided radiotherapy (IGRT). This work analyzes mechanical limitations and gravi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12033

    authors: Keuschnigg P,Kellner D,Fritscher K,Zechner A,Mayer U,Huber P,Sedlmayer F,Deutschmann H,Steininger P

    更新日期:2017-01-01 00:00:00

  • Determination of exit skin dose for 192Ir intracavitary accelerated partial breast irradiation with thermoluminescent dosimeters.

    abstract:PURPOSE:Intracavitary accelerated partial breast irradiation (APBI) has become a popular treatment for early stage breast cancer in recent years due to its shortened course of treatment and simplified treatment planning compared to traditional external beam breast conservation therapy. However, the exit dose to the ski...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3429089

    authors: Raffi JA,Davis SD,Hammer CG,Micka JA,Kunugi KA,Musgrove JE,Winston JW Jr,Ricci-Ott TJ,DeWerd LA

    更新日期:2010-06-01 00:00:00

  • The delta envelope: a technique for dose distribution comparison.

    abstract::The gamma index is a tool that compares a dose distribution with a reference distribution by combining dose-difference and distance-to-agreement criteria. It has been widely used for ten years despite its high computational cost. This cost is due to both a search process for each reference point and the necessity to r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3070546

    authors: Blanpain B,Mercier D

    更新日期:2009-03-01 00:00:00

  • Anthropomorphic 1H MRS head phantom.

    abstract::An anthropomorphic 1H MRS head phantom has been developed which mimics the in vivo structure, metabolite concentrations, and relaxation times (for both water and metabolites) of human brain tissue. Different brain regions and two tumor types, fluid-containing ventricles, and air-filled sinus, and subcutaneous fat are ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598306

    authors: Rice JR,Milbrandt RH,Madsen EL,Frank GR,Boote EJ,Blechinger JC

    更新日期:1998-07-01 00:00:00