Computerized analysis of mammographic microcalcifications in morphological and texture feature spaces.

Abstract:

:We are developing computerized feature extraction and classification methods to analyze malignant and benign microcalcifications on digitized mammograms. Morphological features that described the size, contrast, and shape of microcalcifications and their variations within a cluster were designed to characterize microcalcifications segmented from the mammographic background. Texture features were derived from the spatial gray-level dependence (SGLD) matrices constructed at multiple distances and directions from tissue regions containing microcalcifications. A genetic algorithm (GA) based feature selection technique was used to select the best feature subset from the multi-dimensional feature spaces. The GA-based method was compared to the commonly used feature selection method based on the stepwise linear discriminant analysis (LDA) procedure. Linear discriminant classifiers using the selected features as input predictor variables were formulated for the classification task. The discriminant scores output from the classifiers were analyzed by receiver operating characteristic (ROC) methodology and the classification accuracy was quantified by the area, Az, under the ROC curve. We analyzed a data set of 145 mammographic microcalcification clusters in this study. It was found that the feature subsets selected by the GA-based method are comparable to or slightly better than those selected by the stepwise LDA method. The texture features (Az = 0.84) were more effective than morphological features (Az = 0.79) in distinguishing malignant and benign microcalcifications. The highest classification accuracy (Az = 0.89) was obtained in the combined texture and morphological feature space. The improvement was statistically significant in comparison to classification in either the morphological (p = 0.002) or the texture (p = 0.04) feature space alone. The classifier using the best feature subset from the combined feature space and an appropriate decision threshold could correctly identify 35% of the benign clusters without missing a malignant cluster. When the average discriminant score from all views of the same cluster was used for classification, the Az value increased to 0.93 and the classifier could identify 50% of the benign clusters at 100% sensitivity for malignancy. Alternatively, if the minimum discriminant score from all views of the same cluster was used, the Az value would be 0.90 and a specificity of 32% would be obtained at 100% sensitivity. The results of this study indicate the potential of using combined morphological and texture features for computer-aided classification of microcalcifications.

journal_name

Med Phys

journal_title

Medical physics

authors

Chan HP,Sahiner B,Lam KL,Petrick N,Helvie MA,Goodsitt MM,Adler DD

doi

10.1118/1.598389

subject

Has Abstract

pub_date

1998-10-01 00:00:00

pages

2007-19

issue

10

eissn

0094-2405

issn

2473-4209

journal_volume

25

pub_type

杂志文章
  • Rotational micro-CT using a clinical C-arm angiography gantry.

    abstract::Rotational angiography (RA) gantries are used routinely to acquire sequences of projection images of patients from which 3D renderings of vascular structures are generated using Feldkamp cone-beam reconstruction algorithms. However, these systems have limited resolution (<4 lp/mm). Micro-computed tomography (micro-CT)...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.2989989

    authors: Patel V,Hoffmann KR,Ionita CN,Keleshis C,Bednarek DR,Rudin S

    更新日期:2008-10-01 00:00:00

  • Shimming with permanent magnets for the x-ray detector in a hybrid x-ray/ MR system.

    abstract::In this x-ray/MR hybrid system an x-ray flat panel detector is placed under the patient cradle, close to the MR volume of interest (VOI), where the magnetic field strength is approximately 0.5 T. Immersed in this strong field, several electronic components inside the detector become magnetized and create an additional...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2963994

    authors: Wen Z,Fahrig R,Williams ST,Pelc NJ

    更新日期:2008-09-01 00:00:00

  • Fast reconstruction with uniform noise properties in halfscan computed tomography.

    abstract::The hybrid algorithms developed recently for the reconstruction of fan-beam images possess computational and noise properties superior to those of the fan-beam filtered backprojection (FFBP) algorithm. However, the hybrid algorithms cannot be applied directly to a halfscan fan-beam sinogram because they require knowle...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1288239

    authors: Pan X

    更新日期:2000-09-01 00:00:00

  • Segmentation of bone CT images and assessment of bone structure using measures of complexity.

    abstract::A nondestructive and noninvasive method for numeric characterization (quantification) of the structural composition of human bone tissue has been developed and tested. In order to quantify and to compare the structural composition of bones from 2D computed tomography (CT) images acquired at different skeletal location...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2336501

    authors: Saparin P,Thomsen JS,Kurths J,Beller G,Gowin W

    更新日期:2006-10-01 00:00:00

  • Optimized low-kV spectrum of dual-energy CT equipped with high-kV tin filtration for electron density measurements.

    abstract:PURPOSE:This paper describes the low-kV spectral optimization of dual-energy CT (DECT) equipped with high-kV tin filtration for the quantitative acquisition of electron density information, which is essential for treatment planning in radiotherapy. In addition, an analytical DECT image simulation was preliminarily perf...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3584200

    authors: Saito M

    更新日期:2011-06-01 00:00:00

  • Cone-beam CT dose and imaging performance evaluation with a modular, multipurpose phantom.

    abstract:PURPOSE:A modular phantom for dosimetry and imaging performance evaluation in cone-beam computed tomography (CBCT) is reported, providing a tool for quantitative technical assessment that can be adapted to a broad variety of CBCT imaging configurations and clinical applications. METHODS:The phantom presents a set of m...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13952

    authors: Siewerdsen JH,Uneri A,Hernandez AM,Burkett GW,Boone JM

    更新日期:2020-02-01 00:00:00

  • A simple model for transit dosimetry based on a water equivalent EPID.

    abstract:PURPOSE:The aim of this study was to demonstrate a new model for implementing a transit dosimetry system as a means of in vivo dose verification with a water equivalent electronic portal imaging device (WE-EPID) and a conventional treatment planning system (TPS). METHOD AND MATERIALS:A standard amorphous silicon (a-Si...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12742

    authors: Deshpande S,Blake SJ,Xing A,Metcalfe PE,Holloway LC,Vial P

    更新日期:2018-03-01 00:00:00

  • Effects of constant frequency noise in magnetic resonance imaging with nonuniform k-space sampling.

    abstract::Magnetic resonance images can be compromised by constant frequency (CF) noise, such as radio frequency (RF) noise. We investigate the effects of CF noise in four imaging methods with non-uniform k-space sampling: single-shot echo-planar imaging (EPI) with sinusoidal readout gradients, phase-encoded echo-planar spectro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1496096

    authors: Du W,Karczmar GS,Pan X

    更新日期:2002-08-01 00:00:00

  • Comparison of Gafchromic EBT2 and EBT3 films for clinical photon and proton beams.

    abstract:PURPOSE:Dose verification in highly conformal radiation therapy such as IMRT or proton therapy can benefit from the high spatial resolution offered by radio-chromic films such as Gafchromic EBT or EBT2. Recently, a new generation of these films, EBT3, has become available. The composition and thickness of the sensitive...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4737890

    authors: Reinhardt S,Hillbrand M,Wilkens JJ,Assmann W

    更新日期:2012-08-01 00:00:00

  • Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research.

    abstract:PURPOSE:The cone beam computed tomography (CBCT) guided small animal radiation research platform (SARRP) has been developed for focal tumor irradiation, allowing laboratory researchers to test basic biological hypotheses that can modify radiotherapy outcomes in ways that were not feasible previously. CBCT provides exce...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4914860

    authors: Yang Y,Wang KK,Eslami S,Iordachita II,Patterson MS,Wong JW

    更新日期:2015-04-01 00:00:00

  • Radiation dose to the lungs from ventilation studies with 133Xe.

    abstract::The radiation dose to the lungs from 133Xe in lung air is directly proportional to the time integral of 133Xe concentration; i.e., the cumulated concentration in the lungs. Using kinetic models developed to fit clinical observations, we have studied the effect of retention on cumulated concentration in lung air. The m...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594341

    authors: Watson EE,Cloutier RJ

    更新日期:1977-11-01 00:00:00

  • Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy.

    abstract::The objective of this work is to assess the suitability and performance of a new dosimeter system with a novel geometry for the quality assurance (QA) of volumetric modulated arc therapy (VMAT). The new dosimeter system consists of a hollow cylinder (15 and 25 cm inner and outer diameters) with 124 diodes embedded in ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3117563

    authors: Létourneau D,Publicover J,Kozelka J,Moseley DJ,Jaffray DA

    更新日期:2009-05-01 00:00:00

  • On the assay of brachytherapy sources.

    abstract::In many of brachytherapy procedures, a large amount of radioactive sources are used to deliver desired doses to the target volume. It is both the federal regulation recommendation (U.S. Nuclear Regulatory Commission, 10 CFR 35.432) and recommendations of the American Association of Physicists in Medicine (AAPM) [Kutch...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2734723

    authors: Yue NJ,Haffty BG,Yue J

    更新日期:2007-06-01 00:00:00

  • Portal dose image (PDI) prediction for dosimetric treatment verification in radiotherapy. I. An algorithm for open beams.

    abstract::A method is presented for calculation of transmission functions for high energy photon beams through patients. These functions are being used in our clinic for prediction of portal dose images (PDIs) which are compared with PDIs measured with an electronic portal imaging device (EPID). The calculations are based on th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598293

    authors: Pasma KL,Heijmen BJ,Kroonwijk M,Visser AG

    更新日期:1998-06-01 00:00:00

  • Automatic learning-based beam angle selection for thoracic IMRT.

    abstract:PURPOSE:The treatment of thoracic cancer using external beam radiation requires an optimal selection of the radiation beam directions to ensure effective coverage of the target volume and to avoid unnecessary treatment of normal healthy tissues. Intensity modulated radiation therapy (IMRT) planning is a lengthy process...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4908000

    authors: Amit G,Purdie TG,Levinshtein A,Hope AJ,Lindsay P,Marshall A,Jaffray DA,Pekar V

    更新日期:2015-04-01 00:00:00

  • TransitQA - A new method for transit dosimetry of Tomotherapy patients.

    abstract:PURPOSE:TransitQA is an innovative method for Tomotherapy transit dosimetry using the on-board detector (OBD). Our previously published model for Tomotherapy treatment plan verification (AirQA) has been enhanced to take into account patient and couch transmission. AirQA estimates the OBD signal during irradiation with ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12672

    authors: Pisaturo O,Miéville F,Tercier PA,Allal AS

    更新日期:2018-01-01 00:00:00

  • Design and evaluation of a HDR skin applicator with flattening filter.

    abstract::The purposes of this study are: (i) to design field flattening filters for the Leipzig applicators of 2 and 3 cm of inner diameter with the source traveling parallel to the applicator contact surface, which are accessories of the microSelectron-HDR afterloader (Nucletron, Veenendaal, The Netherlands). These filters, m...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2825622

    authors: Granero D,Pérez-Calatayud J,Gimeno J,Ballester F,Casal E,Crispín V,van der Laarse R

    更新日期:2008-02-01 00:00:00

  • Regularization strategies in statistical image reconstruction of low-dose x-ray CT: A review.

    abstract::Statistical image reconstruction (SIR) methods have shown potential to substantially improve the image quality of low-dose x-ray computed tomography (CT) as compared to the conventional filtered back-projection (FBP) method. According to the maximum a posteriori (MAP) estimation, the SIR methods are typically formulat...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.13123

    authors: Zhang H,Wang J,Zeng D,Tao X,Ma J

    更新日期:2018-10-01 00:00:00

  • The impact of small motion on the visualization of coronary vessels and lesions in cardiac CT: A simulation study.

    abstract:PURPOSE:Coronary x-ray computed tomography angiography (CCTA) is used to non-invasively assess coronary artery geometry and has, combined with computational modeling, demonstrated the potential to identify physiologically significant lesions. These measurements require robust and accurate coronary imaging and delineati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12295

    authors: Contijoch F,Stayman JW,McVeigh ER

    更新日期:2017-07-01 00:00:00

  • SAPHIRE (scintillator avalanche photoconductor with high resolution emitter readout) for low dose x-ray imaging: spatial resolution.

    abstract::An indirect flat panel imager (FPI) with programmable avalanche gain and field emitter array (FEA) readout is being investigated for low-dose and high resolution x-ray imaging. It is made by optically coupling a structured x-ray scintillator, e.g., thallium (Tl) doped cesium iodide (CsI), to an amorphous selenium (a-S...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2937652

    authors: Li D,Zhao W

    更新日期:2008-07-01 00:00:00

  • Interleaf leakage for 5 and 10 mm dynamic multileaf collimation systems incorporating patient motion.

    abstract::Use of dynamic multileaf collimation (DMLC) for intensity modulated radiation therapy (IMRT) is accelerating. Delivery systems have the ailment of interleaf leakage (IL). This is compounded by the inefficiency of IMRT delivery, estimated to be a factor of 5 for DMLC. With IL on the order of 4%, it is possible to deliv...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1388216

    authors: Klein EE,Low DA

    更新日期:2001-08-01 00:00:00

  • The Jacobian as a measure of planar dose congruence.

    abstract::We propose a new starting point for comparing planar dose distributions using a Jacobian-based measure. The measure is normalization independent, i.e., is sensitive to dose patterns while not being biased by global dose scaling. The measure is free of tunable parameters and is bounded between zero and one. We also pro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2982136

    authors: Paniak LD,Charland PM

    更新日期:2008-11-01 00:00:00

  • The use of modified single pencil beam dose kernels to improve IMRT dose calculation accuracy.

    abstract::Intensity modulated radiation therapy (IMRT) is used to deliver highly conformal radiation doses to tumors while sparing nearby sensitive tissues. Discrepancies between calculated and measured dose distributions have been reported for regions of high dose gradients corresponding to complex radiation fluence patterns. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1812851

    authors: Bergman AM,Otto K,Duzenli C

    更新日期:2004-12-01 00:00:00

  • Dosimetric characterization of Ir-192 LDR elongated sources.

    abstract::Ir-192 wires have been used in low-dose-rate brachytherapy for many years. Commercially available treatment planning systems approximate the dose rate distribution of the straight or curved wires applying the superposition principle using one of the following methods: (i) The wire is modeled as a set of point sources,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2839102

    authors: van der Laarse R,Granero D,Pérez-Calatayud J,Meigooni AS,Ballester F

    更新日期:2008-03-01 00:00:00

  • Independent quality assurance of a helical tomotherapy machine using the dose magnifying glass.

    abstract:PURPOSE:Helical tomotherapy is a complex delivery technique, integrating CT image guidance and intensity modulated radiotherapy in a single system. The integration of the CT detector ring on the gantry not only allows patient position verification but is also often used to perform various QA procedures. This convenienc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3566067

    authors: Wong JH,Hardcastle N,Tomé WA,Bayliss A,Tolakanahalli R,Lerch ML,Petasecca M,Carolan M,Metcalfe P,Rosenfeld AB

    更新日期:2011-04-01 00:00:00

  • Thermoacoustic molecular tomography with magnetic nanoparticle contrast agents for targeted tumor detection.

    abstract:PURPOSE:The primary feasibility steps of demonstrating the ability of microwave-induced thermoacoustic (TA) in phantoms have been previously reported. However, none were shown to target a diseased site in living subjects in thermoacoustic tomography (TAT) field so far. To determine the expressions of oncogenic surface ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3466696

    authors: Nie L,Ou Z,Yang S,Xing D

    更新日期:2010-08-01 00:00:00

  • Computerized radiographic texture measures for characterizing bone strength: a simulated clinical setup using femoral neck specimens.

    abstract::We are investigating computerized methods to ultimately characterize bone trabecular pattern from clinical skeletal radiographs. In this paper, we present a "phantom" for potential use in the development and evaluation of computerized methods for characterizing radiographic trabecular patterns and ultimately bone stre...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598743

    authors: Chinander MR,Giger ML,Martell JM,Jiang C,Favus MJ

    更新日期:1999-11-01 00:00:00

  • Automated bone segmentation from dental CBCT images using patch-based sparse representation and convex optimization.

    abstract:PURPOSE:Cone-beam computed tomography (CBCT) is an increasingly utilized imaging modality for the diagnosis and treatment planning of the patients with craniomaxillofacial (CMF) deformities. Accurate segmentation of CBCT image is an essential step to generate three-dimensional (3D) models for the diagnosis and treatmen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4868455

    authors: Wang L,Chen KC,Gao Y,Shi F,Liao S,Li G,Shen SG,Yan J,Lee PK,Chow B,Liu NX,Xia JJ,Shen D

    更新日期:2014-04-01 00:00:00

  • Evaluation of a compact multicontrast and multiresolution X-ray phase contrast edge illumination system for small animal imaging.

    abstract:PURPOSE:In this work the performance of a compact multiresolution and multicontrast x-ray phase system based on edge illumination is investigated. It has been designed for small animal imaging and with a limited footprint for ease of deployment in laboratories. METHODS:The presented edge illumination system is based o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14553

    authors: Massimi L,Meganck JA,Towns R,Olivo A,Endrizzi M

    更新日期:2020-10-27 00:00:00

  • Individually optimized contrast-enhanced 4D-CT for radiotherapy simulation in pancreatic ductal adenocarcinoma.

    abstract:PURPOSE:To develop an individually optimized contrast-enhanced (CE) 4D-computed tomography (CT) for radiotherapy simulation in pancreatic ductal adenocarcinomas (PDA). METHODS:Ten PDA patients were enrolled. Each underwent three CT scans: a 4D-CT immediately following a CE 3D-CT and an individually optimized CE 4D-CT ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4963213

    authors: Choi W,Xue M,Lane BF,Kang MK,Patel K,Regine WF,Klahr P,Wang J,Chen S,D'Souza W,Lu W

    更新日期:2016-10-01 00:00:00