Abstract:
:Ir-192 wires have been used in low-dose-rate brachytherapy for many years. Commercially available treatment planning systems approximate the dose rate distribution of the straight or curved wires applying the superposition principle using one of the following methods: (i) The wire is modeled as a set of point sources, (ii) the wire is modeled as a set of small straight segment wires, (iii) the values of the parameters and functions of the American Association of Physicists in Medicine (AAPM) Task Group 43 protocol are obtained for wire lengths between 3 and 7 cm assuming some simplifications. The dose rate distributions obtained using these methods for linear wires of different lengths and U-shaped wires present significant deviations compared to those obtained by Monte Carlo. In the present study we propose a new method to model 192Ir wires of any length and shape, named the Two Lengths based Segmented method. This method uses the formalism stated in the AAPM Task Group 43 protocol for two straight wires only, 0.5 and 1 cm, to obtain the dose rate distribution around wires of any length (down to 0.3 cm and up to 10 cm) improving on the results of the aforementioned ones. This method can easily be applied to dose calculations around other wires, such as Pd-103 ones.
journal_name
Med Physjournal_title
Medical physicsauthors
van der Laarse R,Granero D,Pérez-Calatayud J,Meigooni AS,Ballester Fdoi
10.1118/1.2839102subject
Has Abstractpub_date
2008-03-01 00:00:00pages
1154-61issue
3eissn
0094-2405issn
2473-4209journal_volume
35pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::The relative sensitivity of the half-value layer (HVL) method as a quality index for megavoltage x-ray beams is examined by theoretical calculation and experimental measurements for 4-, 6-, 10-, and 25-MV x-ray beams. It is shown that lower atomic number materials are more sensitive to beam quality changes than higher...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595794
更新日期:1985-01-01 00:00:00
abstract::Intensity modulated radiotherapy (IMRT) requires extensive knowledge of multileaf collimator (MLC) leaf positioning accuracy, precision, and long-term reproducibility. We have developed a technique to efficiently measure the absolute position of each MLC leaf, over the range of leaf positions utilized in IMRT, based o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1564091
更新日期:2003-05-01 00:00:00
abstract::An indirect flat-panel imager (FPI) with avalanche gain is being investigated for low-dose x-ray imaging. It is made by optically coupling a structured x-ray scintillator CsI(Tl) to an amorphous selenium (a-Se) avalanche photoconductor called HARP (high-gain avalanche rushing photoconductor). The final electronic imag...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2008428
更新日期:2005-09-01 00:00:00
abstract:PURPOSE:A dosimetry evaluation model for treatment planning of esophageal radiation therapy is developed using a deep learning model. The model predicts dose volume histogram (DVH) from distance to target histogram (DTH) based on stacked de-noise auto-encoder (SDAE) and one-dimensional convolutional network (1D-CN). M...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14434
更新日期:2020-10-01 00:00:00
abstract::Soft-tissue detectability in cone-beam computed tomography (CBCT) was evaluated via two-alternative forced-choice (2AFC) tests. Investigations included the dependence of detectability on radiation dose, the influence of the asymmetric three-dimensional (3D) noise-power spectrum (NPS) in axial and sagittal or coronal p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2790586
更新日期:2007-11-01 00:00:00
abstract:PURPOSE:To compare the estimate of normalized glandular dose in mammography and breast CT imaging obtained using the actual glandular tissue distribution in the breast to that obtained using the homogeneous tissue mixture approximation. METHODS:Twenty volumetric images of patient breasts were acquired with a dedicated...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4737025
更新日期:2012-08-01 00:00:00
abstract:PURPOSE:The purpose of this study was to investigate the potential of MR-guided pulsed focused ultrasound (pFUS) for the enhancement of drug uptake in prostate tumors in vivo using doxorubicin (Dox). METHODS:An antitumor drug Dox, an orthotopic animal prostate tumor model using human prostate cancer, LNCaP cell line, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4705346
更新日期:2012-05-01 00:00:00
abstract:PURPOSE:We have investigated the dosimetric errors caused by the interplay between the motions of the LINAC and the tumor during the delivery of a volume modulated arc therapy treatment. This includes the development of an IMRT QA technique, applied here to evaluate RapidArc plans of varying complexity. METHODS:An IMR...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3263614
更新日期:2010-01-01 00:00:00
abstract:PURPOSE:To describe and mathematically validate the superiorization methodology, which is a recently developed heuristic approach to optimization, and to discuss its applicability to medical physics problem formulations that specify the desired solution (of physically given or otherwise obtained constraints) by an opti...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4745566
更新日期:2012-09-01 00:00:00
abstract::Volumetric modulated arc therapy (VMAT) has recently been used to improve the dose distribution and efficiency of treatment delivery over the standard intensity-modulated radiotherapy (IMRT) technique. This study compares the dosimetry between RapidArc plan and standard IMRT plan for head and neck cancer. Three head a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740174
更新日期:2012-07-01 00:00:00
abstract:PURPOSE:To introduce video surface imaging guidance in synchronization with 4D cone-beam CT (CBCT) scans, and in combination with respiration- gated or target-tracked dose delivery to treat mobile tumors, without collaterally damaging nearby critical structures. METHODS:The approach uses the concept that the integral ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734688
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Several works have recently focused on flattening-filter-free (FFF) beams of linear accelerators of various companies (in particular, Varian and Elekta), but no overview as yet exists for the flattening-filter free 7XU beam (Siemens Artiste). METHODS:Dosimetric properties of the 7XU beam were measured in May a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3703835
更新日期:2012-05-01 00:00:00
abstract:PURPOSE:The pulse line ion accelerator (PLIA) is a low-cost accelerator concept originally designed to accelerate heavy ions. Our group has been investigating the use of PLIA to accelerate light ions and believe a multi-stage PLIA could be useful for short half-life PET isotope production. The goal of this work was to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13875
更新日期:2019-12-01 00:00:00
abstract::In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1668391
更新日期:2004-04-01 00:00:00
abstract::A micro-angiographic detector was designed and its performance was previously tested to evaluate its feasibility as an improvement over current x-ray detectors for neuro-interventional imaging. The detector was shown to have a modulation transfer function value of about 2% at the Nyquist frequency of 10 cycles/mm and ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1617550
更新日期:2003-11-01 00:00:00
abstract::Ultrasound has been the greatest imaging modality worldwide for many years by equipment purchase value and by number of machines and examinations. It is becoming increasingly the front end imaging modality; serving often as an extension of the physician's fingers. We believe that at the other extreme, high-end systems...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.2992048
更新日期:2009-02-01 00:00:00
abstract::In this report we evaluate an image registration technique that can improve the information content of intraoperative image data by deformable matching of preoperative images. In this study, pretreatment 1.5 tesla (T) magnetic resonance (MR) images of the prostate are registered with 0.5 T intraoperative images. The m...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1414009
更新日期:2001-12-01 00:00:00
abstract::Two recently developed A 150 plastic-equivalent gas mixtures have been tested for suitability in proportional counter applications. Methane- and propane-based "tissue-equivalent" gases were also included for comparison purposes. Event-size weighted dose distributions were measured in a 14.8-MeV neutron beam. Resolutio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595536
更新日期:1984-07-01 00:00:00
abstract::In previous work it has been shown that a standard backpropagation neural network can be trained to reconstruct sections of single photon emission computed tomography (SPECT) images based on the planar image projections as inputs. In this study, it is demonstrated that an artificial neural network (ANN) trained on a s...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597586
更新日期:1995-05-01 00:00:00
abstract::The photon response of silicon-diode neutron detectors is analyzed theoretically and measured in the 15-25-MeV region. The main mechanism for producing a response in the diode is shown to be the displacement of silicon atoms by scattering of electrons. If the photon source is an electron accelerator target, the respon...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594403
更新日期:1978-01-01 00:00:00
abstract::A beam stop technique was used to measure the densitometric scatter fractions under three regions of a humanoid chest phantom utilizing LaOBr and Gd2O2S screens. For these receptors, the scatter fractions under the lung and retrocardiac areas were 13%-36% lower than published values for CaWO4. In the mediastinal area,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597041
更新日期:1993-03-01 00:00:00
abstract:PURPOSE:The aim of this research was to explore x-ray beam parameters with intent to optimize pediatric x-ray settings in the cardiac catheterization laboratory. This study examined the effects of peak x-ray tube voltage (kVp) and of copper (Cu) x-ray beam filtration independently on the image quality to dose balance f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3488911
更新日期:2010-10-01 00:00:00
abstract:PURPOSE:Real-time adaptive planning and treatment has been infeasible due in part to its high computational complexity. There have been many recent efforts to utilize graphics processing units (GPUs) to accelerate the computational performance and dose accuracy in radiation therapy. Data structure and memory access pat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4895822
更新日期:2014-10-01 00:00:00
abstract:PURPOSE:In the practice code of dosimetry, humidity effect is assumed to be constant as far as the measurements are performed in the relative humidity (RH) range of (20-80)%; thus, the humidity effect can be ignored with a dose uncertainty of 0.15%. This assumption is based on the previous experimental results by Niate...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13665
更新日期:2019-09-01 00:00:00
abstract:PURPOSE:Arterial distensibility is a marker that can measure vessel wall functional and structural changes resulting from atherosclerosis with applications including estimation of mechanical properties of the wall. We sought to assess the feasibility of using magnetic resonance imaging (MRI) to include wall distensibil...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4754302
更新日期:2012-10-01 00:00:00
abstract:PURPOSE:The paper presents a complete computer-aided detection (CAD) system for the detection of lung nodules in computed tomography images. A new mixed feature selection and classification methodology is applied for the first time on a difficult medical image analysis problem. METHODS:The CAD system was trained and t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3633941
更新日期:2011-10-01 00:00:00
abstract::A method for optimizing MR imaging pulse sequence parameters in a statistical framework is presented. Parameters are defined to be optimal when the resulting scalar images yield optimal image segmentations using Bayesian pixel classification. Thus, Bayes risk is used as the objective function to minimize. Approximatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597425
更新日期:1995-10-01 00:00:00
abstract:PURPOSE:The objectives of this study were (a) to devise a technique for measuring quantum noise in clinical body computed tomography (CT) images and (b) to develop a model for predicting that noise with high accuracy. METHODS:The study included 83 clinical image sets at two dose levels (clinical and 50% reduced dose l...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4938588
更新日期:2016-01-01 00:00:00
abstract:PURPOSE:The need for four-dimensional (4D) treatment planning becomes indispensable when it comes to radiation therapy for moving tumors in the thoracic and abdominal regions. The primary purpose of this study is to combine the actual breathing trace during each individual treatment fraction with the Linac's log file i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13579
更新日期:2019-07-01 00:00:00
abstract:PURPOSE:Optoacoustic imaging enables mapping the optical absorption of biological tissue using optical excitation and acoustic detection. Although most image-reconstruction algorithms are based on the assumption of a detector with an isotropic sensitivity, the geometry of the detector often leads to a response with spa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3589141
更新日期:2011-07-01 00:00:00