Anniversary paper: evolution of ultrasound physics and the role of medical physicists and the AAPM and its journal in that evolution.

Abstract:

:Ultrasound has been the greatest imaging modality worldwide for many years by equipment purchase value and by number of machines and examinations. It is becoming increasingly the front end imaging modality; serving often as an extension of the physician's fingers. We believe that at the other extreme, high-end systems will continue to compete with all other imaging modalities in imaging departments to be the method of choice for various applications, particularly where safety and cost are paramount. Therapeutic ultrasound, in addition to the physiotherapy practiced for many decades, is just coming into its own as a major tool in the long progression to less invasive interventional treatment. The physics of medical ultrasound has evolved over many fronts throughout its history. For this reason, a topical review, rather than a primarily chronological one is presented. A brief review of medical ultrasound imaging and therapy is presented, with an emphasis on the contributions of medical physicists, the American Association of Physicists in Medicine (AAPM) and its publications, particularly its journal Medical Physics. The AAPM and Medical Physics have contributed substantially to training of physicists and engineers, medical practitioners, technologists, and the public.

journal_name

Med Phys

journal_title

Medical physics

authors

Carson PL,Fenster A

doi

10.1118/1.2992048

subject

Has Abstract

pub_date

2009-02-01 00:00:00

pages

411-28

issue

2

eissn

0094-2405

issn

2473-4209

journal_volume

36

pub_type

杂志文章,评审
  • Skeletal dosimetry for external exposures to photons based on microCT images of spongiosa: consideration of voxel resolution, cluster size, and medullary bone surfaces.

    abstract::Skeletal dosimetry based on microCT images of trabecular bone has recently been introduced to calculate the red bone marrow (RBM) and the bone surface cell (BSC) equivalent doses in human phantoms for external exposure to photons. In order to use the microCT images for skeletal dosimetry, spongiosa voxels in the skele...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3242266

    authors: Kramer R,Khoury HJ,Vieira JW,Robson Brown KA

    更新日期:2009-11-01 00:00:00

  • Dosimetric problems at low monitor unit settings for scanned and scattering foil electron beams.

    abstract::Electron beam dosimetry at low monitor unit (MU) settings is important for dosimetric applications. Dose linearity, beam flatness, and beam energies were studied at low MU settings with various dose rates for different types of linear accelerators. It is observed that for the scattering foil units, the dose/MU is a sm...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597328

    authors: Das IJ,Harrington JC,Akber SF,Tomer AF,Murray JC,Cheng CW

    更新日期:1994-06-01 00:00:00

  • Analyzing the impact of intrafraction motion: correlation of different dose metrics with changes in target D95%.

    abstract:PURPOSE:A number of techniques are available to determine the dosimetric impact of intrafraction motion during intensity modulated radiation therapy (IMRT). Motion-induced dose perturbations can be determined both computationally and experimentally using a number of different dosimetric metrics. However, these measures...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3605633

    authors: Waghorn BJ,Meeks SL,Langen KM

    更新日期:2011-08-01 00:00:00

  • Monte Carlo assessment of computed tomography dose to tissue adjacent to the scanned volume.

    abstract::The assessment of the radiation dose to internal organs or to an embryo or fetus is required on occasion for risk assessment or for comparing imaging studies. Limited resources hinder the ability to accurately assess the radiation dose received to locations outside the tissue volume actually scanned during computed to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1312809

    authors: Boone JM,Cooper VN 3rd,Nemzek WR,McGahan JP,Seibert JA

    更新日期:2000-10-01 00:00:00

  • Comparison of p-type commercial electron diodes for in vivo dosimetry.

    abstract::This paper compares the characteristics of three types of commercial p-type electron diodes specially designed for in vivo dosimetry (Scanditronix EDD2, Sun Nuclear QED 111200-0 and PTW T60010E diodes coupled with a Therados DPD510 dosimeter) in electron fields with energies from 4.5 to 21 MeV, and in conditions simil...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1630492

    authors: Marre D,Marinello G

    更新日期:2004-01-01 00:00:00

  • A simple test phantom for stereotactic computed tomography.

    abstract::An easy-to-use phantom has been constructed for checking the accuracy of a stereotactic computed tomography localization system. This phantom has been used on a commercially available stereotactic radiosurgery system. With this system, the phantom reference point, whose location is established by means of a precision ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597034

    authors: Ekstrand KE,Olds WW,Branch CL

    更新日期:1993-03-01 00:00:00

  • Gold nanoparticle enhanced proton therapy: A Monte Carlo simulation of the effects of proton energy, nanoparticle size, coating material, and coating thickness on dose and radiolysis yield.

    abstract:PURPOSE:Radiosensitizer enhanced radiotherapy provides the possibility of improved treatment outcomes by preferentially increasing the effectiveness of radiation within the tumor. Proton therapy offers improved sparing of tissue distal of the tumor along the beam path and reduced integral dose compared to conventional ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13923

    authors: Peukert D,Kempson I,Douglass M,Bezak E

    更新日期:2020-02-01 00:00:00

  • A framework for quantification and visualization of segmentation accuracy and variability in 3D lateral ventricle ultrasound images of preterm neonates.

    abstract:PURPOSE:Intraventricular hemorrhage (IVH) is a major cause of brain injury in preterm neonates. Three dimensional ultrasound (US) imaging systems have been developed to visualize 3D anatomical structure of preterm neonatal intracranial ventricular system with IVH and ventricular dilation. To allow quantitative analysis...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4932366

    authors: Chen Y,Qiu W,Kishimoto J,Gao Y,Chan RH,de Ribaupierre S,Fenster A,Chiu B

    更新日期:2015-11-01 00:00:00

  • Free-focus radiography using conventional films--radiation exposures in a simulated clinical study.

    abstract::This study compared air exposures during conventional dental and maxillofacial radiography and similar views using free-focus radiography with conventional image receptors. The results show that periapical type surveys on nonscreen film placed extraorally or in the buccal fold may be carried out with an exposure to th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594690

    authors: Jensen TW,Randall GJ,Goldberg AJ

    更新日期:1980-07-01 00:00:00

  • Resolution of pinhole collimators used with gamma cameras.

    abstract::The line spread function (LSF) of an imaging system incorporating a pinhole of 0.275 cm radius and a scintillation camera has been measured and its full width at half maximum (FWHM) compared to the values predicted by an expression based on the resolution index of Anger. In most cases, the actual resolution of the sys...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594755

    authors: Goulet P,Joy ML

    更新日期:1980-09-01 00:00:00

  • Performance characterization of an integrated cone-beam CT system for dedicated gamma radiosurgery.

    abstract:PURPOSE:This work describes the performance characterization of a cone-beam CT-guided radiosurgery device, the Gamma Knife® Icon™. METHODS:The performance tests have been categorized into: (a) image quality and mechanical integrity; (b) image coregistration fidelity; (c) adaptive treatment delivery quality; (d) high d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13073

    authors: Sarfehnia A,Ruschin M,Chugh B,Yeboah C,Becker N,Cho YB,Lee Y

    更新日期:2018-06-29 00:00:00

  • Upgrade and benchmarking of a 4D treatment planning system for scanned ion beam therapy.

    abstract:PURPOSE:Upgrade and benchmarking of a research 4D treatment planning system (4DTPS) suitable for realistic patient treatment planning and treatment simulations taking into account specific requirements for scanned ion beam therapy, i.e., modeling of dose heterogeneities due to interplay effects and range changes caused...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4800802

    authors: Richter D,Schwarzkopf A,Trautmann J,Krämer M,Durante M,Jäkel O,Bert C

    更新日期:2013-05-01 00:00:00

  • A Monte Carlo investigation of low-Z target image quality generated in a linear accelerator using Varian's VirtuaLinac.

    abstract:PURPOSE:The focus of this work was the demonstration and validation of VirtuaLinac with clinical photon beams and to investigate the implementation of low-Z targets in a TrueBeam linear accelerator (Linac) using Monte Carlo modeling. METHODS:VirtuaLinac, a cloud based web application utilizing Geant4 Monte Carlo code,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4861818

    authors: Parsons D,Robar JL,Sawkey D

    更新日期:2014-02-01 00:00:00

  • Precision of dosimetry-related measurements obtained on current multidetector computed tomography scanners.

    abstract:PURPOSE:Computed tomography (CT) intrascanner and interscanner variability has not been well characterized. Thus, the purpose of this study was to examine the within-run, between-run, and between-scanner precision of physical dosimetry-related measurements collected over the course of 1 yr on three different makes and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3426000

    authors: Mathieu KB,McNitt-Gray MF,Zhang D,Kim HJ,Cody DD

    更新日期:2010-08-01 00:00:00

  • Optimization of the dose delivery in a few field techniques using radiobiological objective functions.

    abstract::A method for finding optimal primary fluence profiles for multiple field external beam radiation therapy techniques has been developed using a radiobiologically based objective function that quantifies the probability of achieving complication-free tumor control, P+. The objective function P+ has the valuable property...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596971

    authors: Södertröm S,Brahme A

    更新日期:1993-07-01 00:00:00

  • Automated segmentation of lungs with severe interstitial lung disease in CT.

    abstract:PURPOSE:Accurate segmentation of lungs with severe interstitial lung disease (ILD) in thoracic computed tomography (CT) is an important and difficult task in the development of computer-aided diagnosis (CAD) systems. Therefore, we developed in this study a texture analysis-based method for accurate segmentation of lung...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3222872

    authors: Wang J,Li F,Li Q

    更新日期:2009-10-01 00:00:00

  • Exposure artifacts in raster scanned equalization radiography.

    abstract::The image artifacts characteristic of a scanning chest radiographic system are reviewed. The technique employs a pulsed beam of radiation swept in an overlapping raster pattern that can result in severe ripple and scan line artifacts with improper scanning parameters. A one-dimensional treatment of the scanner geometr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595492

    authors: Plewes DB,Vogelstein E

    更新日期:1984-03-01 00:00:00

  • A novel off-axis scanning method for an enlarged ellipse cone-beam computed tomography field of view.

    abstract:PURPOSE:Current on-board imaging systems commonly used by modern linear accelerators (LINACs) have a limited field of view (FOV) for a cone-beam CT (CBCT) scan, which is typically less than 50 cm. Consequently, truncation artifacts often occur for large patients. The goal of this work is to investigate a novel method t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3514130

    authors: Li T,Li X,Yang Y,Heron DE,Huq MS

    更新日期:2010-12-01 00:00:00

  • Vision 20/20: Molecular-guided surgical oncology based upon tumor metabolism or immunologic phenotype: Technological pathways for point of care imaging and intervention.

    abstract::Surgical guidance with fluorescence has been demonstrated in individual clinical trials for decades, but the scientific and commercial conditions exist today for a dramatic increase in clinical value. In the past decade, increased use of indocyanine green based visualization of vascular flow, biliary function, and tis...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4951732

    authors: Pogue BW,Paulsen KD,Samkoe KS,Elliott JT,Hasan T,Strong TV,Draney DR,Feldwisch J

    更新日期:2016-06-01 00:00:00

  • A method for avoiding overlap of left and right lungs in shape model guided segmentation of lungs in CT volumes.

    abstract:PURPOSE:The automated correct segmentation of left and right lungs is a nontrivial problem, because the tissue layer between both lungs can be quite thin. In the case of lung segmentation with left and right lung models, overlapping segmentations can occur. In this paper, the authors address this issue and propose a so...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4894817

    authors: Gill G,Bauer C,Beichel RR

    更新日期:2014-10-01 00:00:00

  • Computerized radiographic texture measures for characterizing bone strength: a simulated clinical setup using femoral neck specimens.

    abstract::We are investigating computerized methods to ultimately characterize bone trabecular pattern from clinical skeletal radiographs. In this paper, we present a "phantom" for potential use in the development and evaluation of computerized methods for characterizing radiographic trabecular patterns and ultimately bone stre...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598743

    authors: Chinander MR,Giger ML,Martell JM,Jiang C,Favus MJ

    更新日期:1999-11-01 00:00:00

  • Technical Note: Study of the electron transport parameters used in PENELOPE for the Monte Carlo simulation of Linac targets.

    abstract:PURPOSE:The Monte Carlo simulation of electron transport in Linac targets using the condensed history technique is known to be problematic owing to a potential dependence of absorbed dose distributions on the electron step length. In the PENELOPE code, the step length is partially determined by the transport parameters...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4916686

    authors: Rodriguez M,Sempau J,Brualla L

    更新日期:2015-06-01 00:00:00

  • A mouse radiation-induced liver disease model for stereotactic body radiation therapy validated in patients with hepatocellular carcinoma.

    abstract:PURPOSE:Lower radiation tolerance of the whole liver hinders dose escalations of stereotactic body radiation therapy (SBRT) in hepatocellular carcinoma (HCC) treatment. This study was conducted to define the exact doses that result in radiation-induced liver disease (RILD) as well as to determine dose constraints for t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4953831

    authors: Wu ZF,Zhang JY,Shen XY,Zhou LY,Gao YB,Hu Y,Zeng ZC

    更新日期:2016-07-01 00:00:00

  • Feasibility of MRI-only treatment planning for proton therapy in brain and prostate cancers: Dose calculation accuracy in substitute CT images.

    abstract:PURPOSE:Magnetic resonance imaging (MRI) is increasingly used for radiotherapy target delineation, image guidance, and treatment response monitoring. Recent studies have shown that an entire external x-ray radiotherapy treatment planning (RTP) workflow for brain tumor or prostate cancer patients based only on MRI refer...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4958677

    authors: Koivula L,Wee L,Korhonen J

    更新日期:2016-08-01 00:00:00

  • SU-E-T-145: MRI Gel Dosimetry Applied to Dose Profile Determination for 50kV X-Ray Tube.

    abstract:PURPOSE:The aim of this study was to use MRI gel dosimetry to determine the dose profile of 50kV MAGNUM® X-ray tube, MOXTEK Inc., in order to calibrate small solid dosimeters of alanine, tooth enamel and LiF-TLDs, commonly used in clinical quality assurance and datation dosimetry. METHODS:MAGIC-f polymer gel was kept ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735203

    authors: Schwarcke M,Marques T,Nicolucci P,Filho OB

    更新日期:2012-06-01 00:00:00

  • Mammogram synthesis using a three-dimensional simulation. III. Modeling and evaluation of the breast ductal network.

    abstract::A method is proposed for realistic simulation of the breast ductal network as part of a computer three-dimensional (3-D) breast phantom. The ductal network is simulated using tree models. Synthetic trees are generated based upon a description of ductal branching by ramification matrices (R matrices), whose elements re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1586453

    authors: Bakic PR,Albert M,Brzakovic D,Maidment AD

    更新日期:2003-07-01 00:00:00

  • Mitigating differential baseline shifts in locally advanced lung cancer patients using an average anatomy model.

    abstract:BACKGROUND AND PURPOSE:Differential baseline shifts between primary tumor and involved lymph nodes in locally advanced lung cancer patients compromise the accuracy of radiotherapy. The purpose of this study was to evaluate the performance of an average anatomy model (AAM) derived from repeat imaging and deformable regi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12271

    authors: Abdoli M,Van Kranen SR,Stankovic U,Rossi MMG,Belderbos JSA,Sonke JJ

    更新日期:2017-07-01 00:00:00

  • Photon and electron response of silicon-diode neutron detectors.

    abstract::The photon response of silicon-diode neutron detectors is analyzed theoretically and measured in the 15-25-MeV region. The main mechanism for producing a response in the diode is shown to be the displacement of silicon atoms by scattering of electrons. If the photon source is an electron accelerator target, the respon...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594403

    authors: McCall RC,Jenkins TM,Oliver GD Jr

    更新日期:1978-01-01 00:00:00

  • Medical applications of shortwave FM radar: remote monitoring of cardiac and respiratory motion.

    abstract:PURPOSE:This article introduces the use of low power continuous wave frequency modulated radar for medical applications, specifically for remote monitoring of vital signs in patients. METHODS:Gigahertz frequency radar measures the electromagnetic wave signal reflected from the surface of a human body and from tissue b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3267038

    authors: Mostov K,Liptsen E,Boutchko R

    更新日期:2010-03-01 00:00:00

  • Assessment of the limiting spatial resolution of an MRI scanner by direct analysis of the edge spread function.

    abstract::Limiting spatial resolution is a key metric of the quality of magnetic resonance (MR) images, which can provide an indication of the smallest region that can effectively be imaged. In this paper a novel methodology for measuring the limiting spatial resolution of MR images is mathematically analyzed and successfully i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3097633

    authors: Delakis I,Xanthis C,Kitney RI

    更新日期:2009-05-01 00:00:00