Abstract:
PURPOSE:The focus of this work was the demonstration and validation of VirtuaLinac with clinical photon beams and to investigate the implementation of low-Z targets in a TrueBeam linear accelerator (Linac) using Monte Carlo modeling. METHODS:VirtuaLinac, a cloud based web application utilizing Geant4 Monte Carlo code, was used to model the Linac treatment head components. Particles were propagated through the lower portion of the treatment head using BEAMnrc. Dose distributions and spectral distributions were calculated using DOSXYZnrc and BEAMdp, respectively. For validation, 6 MV flattened and flattening filter free (FFF) photon beams were generated and compared to measurement for square fields, 10 and 40 cm wide and at dmax for diagonal profiles. Two low-Z targets were investigated: a 2.35 MeV carbon target and the proposed 2.50 MeV commercial imaging target for the TrueBeam platform. A 2.35 MeV carbon target was also simulated in a 2100EX Clinac using BEAMnrc. Contrast simulations were made by scoring the dose in the phosphor layer of an IDU20 aSi detector after propagating through a 4 or 20 cm thick phantom composed of water and ICRP bone. RESULTS:Measured and modeled depth dose curves for 6 MV flattened and FFF beams agree within 1% for 98.3% of points at depths greater than 0.85 cm. Ninety three percent or greater of points analyzed for the diagonal profiles had a gamma value less than one for the criteria of 1.5 mm and 1.5%. The two low-Z target photon spectra produced in TrueBeam are harder than that from the carbon target in the Clinac. Percent dose at depth 10 cm is greater by 3.6% and 8.9%; the fraction of photons in the diagnostic energy range (25-150 keV) is lower by 10% and 28%; and contrasts are lower by factors of 1.1 and 1.4 (4 cm thick phantom) and 1.03 and 1.4 (20 cm thick phantom), for the TrueBeam 2.35 MV/carbon and commercial imaging beams, respectively. CONCLUSIONS:VirtuaLinac is a promising new tool for Monte Carlo modeling of novel target designs. A significant spectral difference is observed between the low-Z target beam on the Clinac platform and the proposed imaging beam line on TrueBeam, with the former providing greater diagnostic energy content.
journal_name
Med Physjournal_title
Medical physicsauthors
Parsons D,Robar JL,Sawkey Ddoi
10.1118/1.4861818subject
Has Abstractpub_date
2014-02-01 00:00:00pages
021719issue
2eissn
0094-2405issn
2473-4209journal_volume
41pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::The objective of this work is to assess the suitability and performance of a new dosimeter system with a novel geometry for the quality assurance (QA) of volumetric modulated arc therapy (VMAT). The new dosimeter system consists of a hollow cylinder (15 and 25 cm inner and outer diameters) with 124 diodes embedded in ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3117563
更新日期:2009-05-01 00:00:00
abstract::A micro-angiographic detector was designed and its performance was previously tested to evaluate its feasibility as an improvement over current x-ray detectors for neuro-interventional imaging. The detector was shown to have a modulation transfer function value of about 2% at the Nyquist frequency of 10 cycles/mm and ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1617550
更新日期:2003-11-01 00:00:00
abstract::Image correlation is often required to utilize the complementary information in CT, MRI, and SPECT. A practical method for automatic image correlation in three-dimensions (3D) based on chamfer matching is described. The method starts with automatic extraction of contour points in one modality and automatic segmentatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597344
更新日期:1994-07-01 00:00:00
abstract::An important aspect of the intensity modulated radiotherapy (IMRT) process is that of optimizing the beam intensity profiles. Most such methods use a comparison between the defined dose distribution (including prescription dose and dose limits for critical structures) and the current distribution. The comparison may i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1428756
更新日期:2002-01-01 00:00:00
abstract::Single photon emission computed tomography (SPECT) was investigated for imaging on-board radiation therapy machines in order to localize functional and molecular targets. A computer-simulated female NCAT phantom was positioned supine on a flat-top treatment couch. Twenty tumor locations were defined in the upper torso...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3113902
更新日期:2009-05-01 00:00:00
abstract:PURPOSE:Compton camera imaging (CCI) systems are currently under investigation for radiotherapy dose reconstruction and verification. The ability of such a system to provide real-time images during dose delivery will be limited by the computational speed of the image reconstruction algorithm. In this work, the authors ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3519873
更新日期:2011-01-01 00:00:00
abstract:PURPOSE:To compare organ specific cancer incidence risks for standard and complex external beam radiotherapy (including cone beam CT verification) following breast conservation surgery for early breast cancer. METHOD:Doses from breast radiotherapy and kilovoltage cone beam CT (CBCT) exposures were obtained from thermo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4748332
更新日期:2012-10-01 00:00:00
abstract::The Monte Carlo (MC) method has been shown through many research studies to calculate accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient tissues where the effects of electron transport cannot be accurately handled with conventional, deterministic dose algorithms. Despite its p...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.2795842
更新日期:2007-12-01 00:00:00
abstract:PURPOSE:Over the last ten years, there has been an extensive growth in the development of microSPECT imagers. Most of the systems are based on the combination of conventional, relatively large gamma cameras with poor intrinsic spatial resolution and multipinhole collimators working in large magnification mode. Spatial ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4822621
更新日期:2013-11-01 00:00:00
abstract:PURPOSE:This article presents an iterative method for compensation of motion artifacts for slowly rotating computed tomography (CT) systems. Patient's motion introduces inconsistencies among projections and yields severe reconstruction artifacts for free-breathing acquisitions. Streaks and doubling of structures can ap...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3244035
更新日期:2009-11-01 00:00:00
abstract::An automated data-acquisition and analysis system has been developed for dosimetry measurements on the pion therapy beam at the Clinton P. Anderson Meson Physics Facility Biomedical Channel in Los Alamos using a PDP-11/45 computer and CAMAC interface. Initialization, test, and monitor programs allow the user to set th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594418
更新日期:1978-03-01 00:00:00
abstract::Modern computed tomography (CT) scanners use cone-beam configurations for increasing volume coverage, improving x-ray-tube utilization, and yielding isotropic spatial resolution. Recently, there have been significant developments in theory and algorithms for exact image reconstruction from cone-beam projections. In pa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2337270
更新日期:2006-10-01 00:00:00
abstract:PURPOSE:In fractionated radiation therapy, image guidance with daily tomographic imaging becomes more and more clinical routine. In principle, this allows for daily computation of the delivered dose and for accumulation of these daily dose distributions to determine the actually delivered total dose to the patient. How...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3697524
更新日期:2012-04-01 00:00:00
abstract::Limiting spatial resolution is a key metric of the quality of magnetic resonance (MR) images, which can provide an indication of the smallest region that can effectively be imaged. In this paper a novel methodology for measuring the limiting spatial resolution of MR images is mathematically analyzed and successfully i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3097633
更新日期:2009-05-01 00:00:00
abstract:PURPOSE:Detailed characterization of changes in vessel size is crucial for the diagnosis and management of a variety of vascular diseases. Because clinical measurement of vessel size is typically dependent on the radiologist's subjective interpretation of the vessel borders, it is often prone to high inter- and intra-u...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12580
更新日期:2017-12-01 00:00:00
abstract:PURPOSE:The standardized uptake value (SUV) is a quantitative measure of FDG tumor uptake frequently used as a tool to monitor therapeutic response. This study aims to (i) assess the reproducibility and uncertainty of SUV max and SUV mean, due to purely statistical, i.e., nonbiological, effects and (ii) to establish th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3578604
更新日期:2011-05-01 00:00:00
abstract::We present a technique for semiautomated segmentation of human prostates using suprapubic ultrasound (US) images. In this approach, a speckle reducing anisotropic diffusion (SRAD) is applied to enhance the images and the instantaneous coefficient of variation (ICOV) is utilized for edge detection. Segmentation is acco...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1809791
更新日期:2004-12-01 00:00:00
abstract::The assessment of the radiation dose to internal organs or to an embryo or fetus is required on occasion for risk assessment or for comparing imaging studies. Limited resources hinder the ability to accurately assess the radiation dose received to locations outside the tissue volume actually scanned during computed to...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1312809
更新日期:2000-10-01 00:00:00
abstract:PURPOSE:A dosimetry evaluation model for treatment planning of esophageal radiation therapy is developed using a deep learning model. The model predicts dose volume histogram (DVH) from distance to target histogram (DTH) based on stacked de-noise auto-encoder (SDAE) and one-dimensional convolutional network (1D-CN). M...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14434
更新日期:2020-10-01 00:00:00
abstract::The geometric accuracy and precision of an image-guided treatment system were assessed. Image guidance is performed using an x-ray volume imaging (XVI) system integrated with a linear accelerator and treatment planning system. Using an amorphous silicon detector and x-ray tube, volumetric computed tomography images ar...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2143141
更新日期:2006-01-01 00:00:00
abstract:PURPOSE:Precise segmentation of clinical target volume (CTV) is the key to stomach cancer radiotherapy. We proposed a novel stochastic width - deep neural network (SW-DNN) for better automatically contouring stomach CTV METHODS: SW-DNN was an end-to-end approach, of which the core component was a novel SW mechanism tha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14733
更新日期:2021-01-27 00:00:00
abstract:PURPOSE:Automatic breast ultrasound (ABUS) imaging has become an essential tool in breast cancer diagnosis since it provides complementary information to other imaging modalities. Lesion segmentation on ABUS is a prerequisite step of breast cancer computer-aided diagnosis (CAD). This work aims to develop a deep learnin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14569
更新日期:2020-10-30 00:00:00
abstract:PURPOSE:The aim of this study was to implement a Dirichlet process mixture (DPM) model for automatic tumor edge identification on (18)F-fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) images by optimizing the parameters on which the algorithm depends, to validate it experimentally, and to test its robus...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4947123
更新日期:2016-05-01 00:00:00
abstract::The fast imaging method named skipped phase encoding and edge deghosting (SPEED) has been demonstrated to reduce scan time considerably with typical magnetic resonance imaging data. In this work, SPEED is simplified with improved efficiency to accelerate the scan of sparse objects; we refer to this method as S-SPEED. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2750966
更新日期:2007-08-01 00:00:00
abstract:PURPOSE:To compare how the inclusion of the uncertainties in dose and optical density affects the results of the calibration of Gafchromic(®) EBT3 radiochromic films. METHODS:Five methods of least square minimization were compared for calibration of radiochromic films. These differed in the way in which the uncertaint...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4811238
更新日期:2013-07-01 00:00:00
abstract:PURPOSE:The aim of this study was to demonstrate a new model for implementing a transit dosimetry system as a means of in vivo dose verification with a water equivalent electronic portal imaging device (WE-EPID) and a conventional treatment planning system (TPS). METHOD AND MATERIALS:A standard amorphous silicon (a-Si...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12742
更新日期:2018-03-01 00:00:00
abstract::The resolution has been evaluated for an experimental x-ray image intensifier employing three microchannel plates (MCPs) as the photon absorber and electron multipliers. The line spread function (LSF) was measured and used for determination of the modulation transfer function (MTF). The MTF was found to be independent...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594463
更新日期:1978-01-01 00:00:00
abstract:PURPOSE:The quality of a treatment plan for stereotactic body radiotherapy (SBRT) depends on an experience of each treatment planner. Therefore, the treatment plans are subjectively determined by comparison of several treatment plans developed by time consuming iterative manners, while considering the benefit to a tumo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735950
更新日期:2012-06-01 00:00:00
abstract::We believe that, for the purpose of evaluation and optimization of treatment plans, quasirandom sampling is superior to grid sampling and should be the method of choice. We believe it to be on average more efficient than grid sampling (i.e., more accurate for any given number of dose estimates) and, even more importan...
journal_title:Medical physics
pub_type: 评论,信件
doi:10.1118/1.597103
更新日期:1993-09-01 00:00:00
abstract:PURPOSE:In the past decade, phase-contrast imaging (PCI) has been applied to study different kinds of tissues and human body parts, with an increased improvement of the image quality with respect to simple absorption radiography. A technique closely related to PCI is phase-retrieval imaging (PRI). Indeed, PCI is an ima...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3447727
更新日期:2010-07-01 00:00:00