Automatic three-dimensional correlation of CT-CT, CT-MRI, and CT-SPECT using chamfer matching.

Abstract:

:Image correlation is often required to utilize the complementary information in CT, MRI, and SPECT. A practical method for automatic image correlation in three-dimensions (3D) based on chamfer matching is described. The method starts with automatic extraction of contour points in one modality and automatic segmentation of the corresponding feature in the other modality. A distance transform is applied to the segmented volume and a cost function is defined that operates between the contour points and the distance transform. Matching is performed by iteratively optimizing the cost function for 3D translation, rotation, and scaling of the contour points. The complete matching process including segmentation requires no user interaction and takes about 100 s on an HP715/50 workstation. Perturbation tests on clinical data with cost functions based on mean, rms, and maximum distances in combination with two general purpose optimization procedures have been performed. The performance of the methods has been quantified in terms of accuracy, capture range, and reliability. The best results on clinical data are obtained with the cost function based on the mean distance and the simplex optimization method. The accuracy is 0.3 mm for CT-CT, 1.0 mm for CT-MRI, and 0.7 mm for CT-SPECT correlation of the head. The accuracy is usually at subpixel level but is limited by global geometric distortions, e.g., for CT-MRI correlation. Both for CT-CT and CT-MRI correlation the capture range is about 6 cm, which is higher than normal differences in patient setup found on the scanners (less than 4 cm). This means that the correlation procedure seldom fails (better than 98% reliability) and user interaction is unnecessary. For CT-SPECT matching the capture range is about 3 cm (80% reliability), and must be further improved. The method has already been introduced in clinical practice.

journal_name

Med Phys

journal_title

Medical physics

authors

van Herk M,Kooy HM

doi

10.1118/1.597344

subject

Has Abstract

pub_date

1994-07-01 00:00:00

pages

1163-78

issue

7

eissn

0094-2405

issn

2473-4209

journal_volume

21

pub_type

杂志文章
  • Evaluation of carbon nanotube x-ray source array for stationary head computed tomography.

    abstract:PURPOSE:Stationary computed tomography (s-CT) conceptually offers several advantages over existing rotating gantry-based CT. Over the last 40 yr, s-CT has been investigated using different technological approaches. We are developing a s-CT system specifically for head/brain imaging using carbon nanotube (CNT)-based fie...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14696

    authors: Spronk D,Luo Y,Inscoe CR,Lee YZ,Lu J,Zhou O

    更新日期:2020-12-31 00:00:00

  • Toward consensus on quantitative assessment of medical imaging systems.

    abstract::Consensus has been developing over the past few decades on a number of measurements required for the laboratory assessment of medical imaging modalities. Nevertheless, understanding of the connection between these measurements and human observer performance in a broad range of tasks remains far from complete. Focusing...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.597511

    authors: Metz CE,Wagner RF,Doi K,Brown DG,Nishikawa RM,Myers KJ

    更新日期:1995-07-01 00:00:00

  • Automation of routine elements for spot-scanning proton patient-specific quality assurance.

    abstract:PURPOSE:At our institution, all proton patient plans undergo patient-specific quality assurance (PSQA) prior to treatment delivery. For intensity-modulated proton beam therapy, quality assurance is complex and time consuming, and it may involve multiple measurements per field. We reviewed our PSQA workflow and identifi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13246

    authors: Hernandez Morales D,Shan J,Liu W,Augustine KE,Bues M,Davis MJ,Fatyga M,Johnson JE,Mundy DW,Shen J,Younkin JE,Stoker JB

    更新日期:2019-01-01 00:00:00

  • The dosimetric properties of an intraoperative radiation therapy applicator system for a Mevatron-80.

    abstract::An applicator system for intraoperative radiation therapy has been fabricated which does not require physical docking with the accelerator. A dosimetric study has been completed which documents the properties of this system for a variety of electron beam energies, applicator sizes, collimator settings, both primary an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596338

    authors: Nelson CE,Cook R,Rakfal S

    更新日期:1989-09-01 00:00:00

  • A new method to combine 3D reconstruction volumes for multiple parallel circular cone beam orbits.

    abstract:PURPOSE:This article presents a new reconstruction method for 3D imaging using a multiple 360 degrees circular orbit cone beam CT system, specifically a way to combine 3D volumes reconstructed with each orbit. The main goal is to improve the noise performance in the combined image while avoiding cone beam artifacts. M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3484058

    authors: Baek J,Pelc NJ

    更新日期:2010-10-01 00:00:00

  • Leakage and scatter radiation from a double scattering based proton beamline.

    abstract::Proton beams offer several advantages over conventional radiation techniques for treating cancer and other diseases. These advantages might be negated if the leakage and scatter radiation from the beamline and patient are too large. Although the leakage and scatter radiation for the double scattering proton beamlines ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2805086

    authors: Moyers MF,Benton ER,Ghebremedhin A,Coutrakon G

    更新日期:2008-01-01 00:00:00

  • Performance of a 41 x 41 cm2 amorphous silicon flat panel x-ray detector designed for angiographic and R&F imaging applications.

    abstract::We measured the physical imaging performance of a 41 x 41 cm2 amorphous silicon flat panel detector designed for angiographic and R&F imaging applications using methods from the emerging IEC standard for the measurement of detective quantum efficiency (DQE) in digital radiographic detectors. Measurements on 12 product...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1609151

    authors: Granfors PR,Aufrichtig R,Possin GE,Giambattista BW,Huang ZS,Liu J,Ma B

    更新日期:2003-10-01 00:00:00

  • SU-E-J-58: Patient-Specific Biomechanical Head and Neck Models for Interfraction Dose Accumulation.

    abstract:PURPOSE:In this abstract, we discuss a biomechanical head and neck model that will be able to represent patient setup variations as well as physiologic changes and subsequently enable dose calculations on the deformed anatomy. METHODS:We selected Multi Pose MRI as the imaging modality to aid in model development and v...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734893

    authors: Santhanam A,Ennis D,Low D,Kupelian P

    更新日期:2012-06-01 00:00:00

  • Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology.

    abstract::The performance of an indirect-detection, active matrix flat-panel imager (FPI) at diagnostic energies is reported in terms of measured and theoretical signal size, noise power spectrum (NPS), and detective quantum efficiency (DQE). Based upon a 1536 x 1920 pixel, 127 microns pitch array of a-Si:H thin-film transistor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598243

    authors: Siewerdsen JH,Antonuk LE,el-Mohri Y,Yorkston J,Huang W,Cunningham IA

    更新日期:1998-05-01 00:00:00

  • A simple model for transit dosimetry based on a water equivalent EPID.

    abstract:PURPOSE:The aim of this study was to demonstrate a new model for implementing a transit dosimetry system as a means of in vivo dose verification with a water equivalent electronic portal imaging device (WE-EPID) and a conventional treatment planning system (TPS). METHOD AND MATERIALS:A standard amorphous silicon (a-Si...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12742

    authors: Deshpande S,Blake SJ,Xing A,Metcalfe PE,Holloway LC,Vial P

    更新日期:2018-03-01 00:00:00

  • Gafchromic EBT2 film dosimetry in reflection mode with a novel plan-based calibration method.

    abstract:PURPOSE:A dosimetric system formed by Gafchromic EBT2 radiochromic film and Epson Expression 10000XL flatbed scanner was commissioned for dosimetry. In this paper, several open questions concerning the commissioning of radiochromic films for dosimetry were addressed: (a) is it possible to employ this dosimetric system ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4772075

    authors: Mendez I,Hartman V,Hudej R,Strojnik A,Casar B

    更新日期:2013-01-01 00:00:00

  • A limit on dose reduction possible with CT reconstruction algorithms without prior knowledge of the scan subject.

    abstract:PURPOSE:To find an upper bound on the maximum dose reduction possible for any reconstruction algorithm, analytic or iterative, that result from the inclusion of the data statistics. The authors do not analyze noise reduction possible from prior knowledge or assumptions about the object. METHODS:The authors examined th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4941954

    authors: Hsieh SS,Chesler DA,Fleischmann D,Pelc NJ

    更新日期:2016-03-01 00:00:00

  • Photon dose calculation incorporating explicit electron transport.

    abstract::Significant advances have been made in recent years to improve photon dose calculation. However, accurate prediction of dose perturbation effects near the interfaces of different media, where charged particle equilibrium is not established, remain unsolved. Furthermore, changes in atomic number, which affect the multi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597611

    authors: Yu CX,Mackie TR,Wong JW

    更新日期:1995-07-01 00:00:00

  • Bremsstrahlung production at 50 MeV in different target materials and configurations.

    abstract::A combination of Monte Carlo, convolution, and experimental techniques have been used to investigate bremsstrahlung production at 50 MeV in full-range targets to produce narrow elementary photon beams for scanning. Calculations using the ITS 3.0 Monte Carlo system for various target designs, including particle transpo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597681

    authors: Sätherberg A,Andreo P,Karlsson M

    更新日期:1996-04-01 00:00:00

  • Repeatability of SUV measurements in serial PET.

    abstract:PURPOSE:The standardized uptake value (SUV) is a quantitative measure of FDG tumor uptake frequently used as a tool to monitor therapeutic response. This study aims to (i) assess the reproducibility and uncertainty of SUV max and SUV mean, due to purely statistical, i.e., nonbiological, effects and (ii) to establish th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3578604

    authors: Schwartz J,Humm JL,Gonen M,Kalaigian H,Schoder H,Larson SM,Nehmeh SA

    更新日期:2011-05-01 00:00:00

  • Fast dose optimization for rotating shield brachytherapy.

    abstract:PURPOSE:To provide a fast computational method, based on the proximal graph solver (POGS) - A convex optimization solver using the alternating direction method of multipliers (ADMM), for calculating an optimal treatment plan in rotating shield brachytherapy (RSBT). RSBT treatment planning has more degrees of freedom th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12486

    authors: Cho M,Wu X,Dadkhah H,Yi J,Flynn RT,Kim Y,Xu W

    更新日期:2017-10-01 00:00:00

  • Monte Carlo assessment of computed tomography dose to tissue adjacent to the scanned volume.

    abstract::The assessment of the radiation dose to internal organs or to an embryo or fetus is required on occasion for risk assessment or for comparing imaging studies. Limited resources hinder the ability to accurately assess the radiation dose received to locations outside the tissue volume actually scanned during computed to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1312809

    authors: Boone JM,Cooper VN 3rd,Nemzek WR,McGahan JP,Seibert JA

    更新日期:2000-10-01 00:00:00

  • SU-F-BRCD-09: Total Variation (TV) Based Fast Convergent Iterative CBCT Reconstruction with GPU Acceleration.

    abstract:PURPOSE:To improve image quality and reduce imaging dose in CBCT for radiation therapy applications and to realize near real-time image reconstruction based on use of a fast convergence iterative algorithm and acceleration by multi-GPUs. METHODS:An iterative image reconstruction that sought to minimize a weighted leas...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735747

    authors: Xu Q,Yang D,Tan J,Anastasio M

    更新日期:2012-06-01 00:00:00

  • Performance tests of two portable mini gamma cameras for medical applications.

    abstract::We have developed two prototypes of portable gamma cameras for medical applications based on a previous prototype designed and tested by our group. These cameras use a CsI(Na) continuous scintillation crystal coupled to the new flat-panel-type multianode position-sensitive photomultiplier tube, H8500 from Hamamatsu Ph...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2358199

    authors: Sánchez F,Fernández MM,Giménez M,Benlloch JM,Rodríguez-Alvarez MJ,García de Quirós F,Lerche Ch,Pavón N,Palazón JA,Martínez J,Sebastiá A

    更新日期:2006-11-01 00:00:00

  • Active energy selective image detector for dual-energy computed radiography.

    abstract::A new energy selective detector for dual energy computed radiography has been developed that combines many of the advantages of x-ray tube voltage switching and single exposure double screen detectors. The new active detector utilizes electro-optical modulation of the response of the storage phosphor screens to allow ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597831

    authors: Alvarez RE

    更新日期:1996-10-01 00:00:00

  • Comments on "Sampling techniques for the evaluation of treatment plans" [Med. Phys. 20, 151-161 (1993)].

    abstract::We believe that, for the purpose of evaluation and optimization of treatment plans, quasirandom sampling is superior to grid sampling and should be the method of choice. We believe it to be on average more efficient than grid sampling (i.e., more accurate for any given number of dose estimates) and, even more importan...

    journal_title:Medical physics

    pub_type: 评论,信件

    doi:10.1118/1.597103

    authors: Niemierko A,Goitein M

    更新日期:1993-09-01 00:00:00

  • Wedge-shaped dose distributions by computer-controlled collimator motion.

    abstract::We have recently installed a linear accelerator, modified to allow computer control of several machine parameters during irradiation of the patient. As an initial feasibility study of computer-controlled radiation therapy, its application to produce wedge-shaped dose distributions by moving the collimator jaws has bee...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594440

    authors: Kijewski PK,Chin LM,Bjärngard BE

    更新日期:1978-09-01 00:00:00

  • Reduction of ring artifacts in CBCT: detection and correction of pixel gain variations in flat panel detectors.

    abstract:PURPOSE:In using flat panel detectors (FPD) for cone beam computed tomography (CBCT), pixel gain variations may lead to structured nonuniformities in projections and ring artifacts in CBCT images. Such gain variations can be caused by change in detector entrance exposure levels or beam hardening, and they are not accou...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4893278

    authors: Altunbas C,Lai CJ,Zhong Y,Shaw CC

    更新日期:2014-09-01 00:00:00

  • Dose distribution of a 125 keV mean energy microplanar x-ray beam for basic studies on microbeam radiotherapy.

    abstract::A multislit collimator was designed and fabricated for basic studies on microbeam radiation therapy (MRT) with an x-ray energy of about 100 keV. It consists of 30 slits that are 25 microm high, 30 mm wide, and 5 mm thick in the beam direction. The slits were made of 25 microm-thick polyimide sheets that were separated...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2940157

    authors: Ohno Y,Torikoshi M,Suzuki M,Umetani K,Imai Y,Uesugi K,Yagi N

    更新日期:2008-07-01 00:00:00

  • SU-E-I-103: Detecting Anomalous Pixels and Correlated Artifacts in Digital Detectors from Flat-Field Images.

    abstract:PURPOSE:Anomalous pixels may be defined as those pixels whose exposure response relationship is deviant from the typical, expected or calibrated response. A group of anomalous pixels may Result in visible correlated artifacts. Here we demonstrate an approach to identify anomalous pixels and correlated artifacts using f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734820

    authors: Dave J,Gingold E,Yorkston J,Bercha I,Goldman L,Walz-Flannigan A,Willis C

    更新日期:2012-06-01 00:00:00

  • X-ray imaging with amorphous selenium: X-ray to charge conversion gain and avalanche multiplication gain.

    abstract::Fluoroscopy is a low dose imaging technique. As such, a very sensitive detector is required to create images of good quality. Present day flat panel active matrix read out systems introduce an amount of noise that inhibits present direct and indirect methods from producing optimal quality images at fluoroscopic exposu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1513157

    authors: Hunt DC,Kirby SS,Rowlands JA

    更新日期:2002-11-01 00:00:00

  • Automated registration of large deformations for adaptive radiation therapy of prostate cancer.

    abstract::Available deformable registration methods are often inaccurate over large organ variation encountered, for example, in the rectum and bladder. The authors developed a novel approach to accurately and effectively register large deformations in the prostate region for adaptive radiation therapy. A software tool combinin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3095777

    authors: Godley A,Ahunbay E,Peng C,Li XA

    更新日期:2009-04-01 00:00:00

  • Technical Note: On maximizing Cherenkov emissions from medical linear accelerators.

    abstract:PURPOSE:Cherenkov light during MV radiotherapy has recently found imaging and therapeutic applications but is challenged by relatively low fluence. Our purpose is to investigate the feasibility of increasing Cherenkov light production during MV radiotherapy by increasing photon energy and applying specialized beam-hard...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12927

    authors: Shrock Z,Yoon SW,Gunasingha R,Oldham M,Adamson J

    更新日期:2018-07-01 00:00:00

  • Deterministic photon kerma distribution based on the Boltzmann equation for external beam radiation therapy.

    abstract::A photon transport algorithm for fully three-dimensional radiotherapy treatment planning has been developed based on the discrete ordinates (SN) solution of the Boltzmann equation. The algorithm is characterized by orthogonal adaptive meshes, which place additional points where large gradients occur and a procedure to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2960247

    authors: Yuan J,Jette D,Chen W

    更新日期:2008-09-01 00:00:00

  • MO-F-BRA-02: Evaluation of 4D CT to 4D Cone-Beam CT Deformable Image Registration for Lung Cancer Adaptive Radiation Therapy.

    abstract:PURPOSE:To evaluate two deformable image registration (DIR) algorithms for the purpose of contour mapping to support image guided adaptive radiotherapy (IGART) with 4D cone beam CT (4DCBCT). METHODS:Eleven locally advanced non-small cell lung cancer (NSCLC) patients underwent one planning 4D fan- beam CT (4DFBCT) and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735821

    authors: Balik S,Hugo G,Weiss E,Jan N,Roman N,Sleeman W,Fatyga M,Christensen G,Murphy M,Lu J,Keall P,Williamson J

    更新日期:2012-06-01 00:00:00