Assessment of the limiting spatial resolution of an MRI scanner by direct analysis of the edge spread function.

Abstract:

:Limiting spatial resolution is a key metric of the quality of magnetic resonance (MR) images, which can provide an indication of the smallest region that can effectively be imaged. In this paper a novel methodology for measuring the limiting spatial resolution of MR images is mathematically analyzed and successfully implemented on phantom images. The methodology presented in this paper is based on a direct fit of a mathematical expression of the edge spread function (ESF) profile to the ESF data acquired at the interface between different materials. The mathematical expression of ESF was determined by approximating the line spread function (LSF) of the system with a sinc function. The proposed methodology can be applied using signal data from magnitude MRI spin echo images and is not sensitive to noise amplification introduced by differentiating the ESF to produce the LSF, as performed in previous studies. In addition, the proposed methodology provides a quantitative, representative measurement of the limiting spatial resolution of MR images.

journal_name

Med Phys

journal_title

Medical physics

authors

Delakis I,Xanthis C,Kitney RI

doi

10.1118/1.3097633

subject

Has Abstract

pub_date

2009-05-01 00:00:00

pages

1637-42

issue

5

eissn

0094-2405

issn

2473-4209

journal_volume

36

pub_type

杂志文章
  • Surface dose rate calibration of Sr-90 plane ophthalmic applicators.

    abstract::Calibration of an imported strontium-90 ophthalmic applicator at the U.S. National Bureau of Standards (now the National Institute of Standards and Technology) has disclose a significant discrepancy in dose rate calibration (32%-35%) with that quoted by the manufacturer. The University of Wisconsin has investigated th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596702

    authors: Goetsch SJ,Sunderland KS

    更新日期:1991-03-01 00:00:00

  • Scatter rejection by electronic collimation.

    abstract::An electronic scanning-slit technology is under development which involves replacing paired fore and aft slits for scatter rejection with only one fore slit. As the slit scans across the portion of the patient to be imaged, pulsed x-ray exposures produce images of the slit in successive positions, which are digitized ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595940

    authors: Plenkovich D,Sorenson JA,Kruger RA

    更新日期:1986-03-01 00:00:00

  • Accuracy of a 3D laser∕camera surface imaging system for setup verification of the pelvic and thoracic regions in radiotherapy treatments.

    abstract:PURPOSE:The aim of this paper is to investigate the accuracy of a laser∕camera surface imaging system (Sentinel) when used on patients treated in the thorax or pelvic regions and to evaluate system employment conditions and patient setup procedures that provide more accurate results. METHODS:The system was tested on t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4769428

    authors: Pallotta S,Simontacchi G,Marrazzo L,Ceroti M,Paiar F,Biti G,Bucciolini M

    更新日期:2013-01-01 00:00:00

  • Use of CEA TVS film for measuring high energy photon beam dose distributions.

    abstract::CEA TVS film is a therapy verification film that has been recently introduced in the North American market. This film features linear characteristic curves for photon energies from 137Cs to 18 MV as reported by Cheng and Das [Med. Phys. 23, 1225 (1996)]. In Saskatoon, TVS film was investigated for its application in t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598316

    authors: Cadman P

    更新日期:1998-08-01 00:00:00

  • Dose rate and SDD dependence of commercially available diode detectors.

    abstract::The dose-rate dependence of commercially available diode detectors was measured under both high instantaneous dose-rate (pulsed) and low dose rate (continuous, Co-60) radiation. The dose-rate dependence was measured in an acrylic miniphantom at a 5-cm depth in a 10 x 10 cm2 collimator setting, by varying source-to-det...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1650563

    authors: Saini AS,Zhu TC

    更新日期:2004-04-01 00:00:00

  • A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate 192 Ir brachytherapy.

    abstract:PURPOSE:A joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the Australasian Brachytherapy Group (ABG) with the charge, among others, to develop a set of well-defined test case plans and perform calculations and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12459

    authors: Ma Y,Vijande J,Ballester F,Tedgren ÅC,Granero D,Haworth A,Mourtada F,Fonseca GP,Zourari K,Papagiannis P,Rivard MJ,Siebert FA,Sloboda RS,Smith R,Chamberland MJP,Thomson RM,Verhaegen F,Beaulieu L

    更新日期:2017-11-01 00:00:00

  • The Cole relaxation frequency as a parameter to identify cancer in breast tissue.

    abstract:PURPOSE:To correlate the Cole relaxation frequencies obtained from measurements of the electrical properties of breast tissue to the presence or absence of cancer. METHODS:Four-lead impedance measurements were obtained on ex vivo specimens extracted during surgery from 187 volunteer patients. Data were acquired with a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4725172

    authors: Gregory WD,Marx JJ,Gregory CW,Mikkelson WM,Tjoe JA,Shell J

    更新日期:2012-07-01 00:00:00

  • A correction-based dose calculation algorithm for kilovoltage x rays.

    abstract::Frequent and repeated imaging procedures such as those performed in image-guided radiotherapy (IGRT) programs may add significant dose to radiosensitive organs of radiotherapy patients. It has been shown that kV-CBCT results in doses to bone that are up to a factor of 3-4 higher than those in surrounding soft tissue. ...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.3014197

    authors: Ding GX,Pawlowski JM,Coffey CW

    更新日期:2008-12-01 00:00:00

  • Convolutional neural network-based dosimetry evaluation of esophageal radiation treatment planning.

    abstract:PURPOSE:A dosimetry evaluation model for treatment planning of esophageal radiation therapy is developed using a deep learning model. The model predicts dose volume histogram (DVH) from distance to target histogram (DTH) based on stacked de-noise auto-encoder (SDAE) and one-dimensional convolutional network (1D-CN). M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14434

    authors: Jiang D,Yan H,Chang N,Li T,Mao R,Du C,Guo B,Liu J

    更新日期:2020-10-01 00:00:00

  • Measurement of x-ray attenuation coefficients of aqueous solutions of indocyanine green and glycated chitosan.

    abstract::We report our experimental results of measurements of x-ray attenuation coefficients of aqueous solutions of a light absorbing dye, indocyanine green, and an immunoadjuvant, glycated chitosan. In the treatment of metastatic tumors in rats using a novel laser immunotherapy these solutions were administered in situ. The...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598633

    authors: Xu F,Liu H,Wu X,Jiang H,Nordquist RE,Chen WR

    更新日期:1999-07-01 00:00:00

  • In-vivo rectal dose measurements with diodes to avoid misadministrations during intracavitary high dose rate brachytherapy for carcinoma of the cervix.

    abstract::Our purpose in this paper is to present an in vivo dosimetry program designed both for measuring the rectal dose and for avoiding misadministrations in gynecological intracavitary implants. A device containing an energy compensated diode was specially designed for these measurements. Our calibration procedure as well ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598598

    authors: Alecu R,Alecu M

    更新日期:1999-05-01 00:00:00

  • Liver segmentation in contrast enhanced CT data using graph cuts and interactive 3D segmentation refinement methods.

    abstract:PURPOSE:Liver segmentation is an important prerequisite for the assessment of liver cancer treatment options like tumor resection, image-guided radiation therapy (IGRT), radiofrequency ablation, etc. The purpose of this work was to evaluate a new approach for liver segmentation. METHODS:A graph cuts segmentation metho...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3682171

    authors: Beichel R,Bornik A,Bauer C,Sorantin E

    更新日期:2012-03-01 00:00:00

  • A dosimetry review system for cooperative group research.

    abstract::The validity of conclusions drawn from multi-institutional radiotherapy studies is dependent upon the degree to which participating hospitals adhere to study requirements. A major effort undertaken by the Quality Assurance Review Center (QARC) assesses whether or not patient data which are deemed evaluable actually co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595221

    authors: Reinstein LE,McShan D,Glicksman AS

    更新日期:1982-03-01 00:00:00

  • Technical Note: Impact of region of interest size and location in Gafchromic film dosimetry.

    abstract:PURPOSE:To evaluate dependence of measured dose on size and location of region of interest (ROI) in Gafchromic EBT3 film dosimetry. METHODS:Gafchromic EBT3 films were irradiated perpendicularly using the 6MV beam from a linear accelerator at 10 cm depth (100 cm SSD) of a 30 × 30 × 20 cm3 solid water phantom for a rang...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12885

    authors: Gholizadeh Sendani N,Karimian A,Ferreira C,Alaei P

    更新日期:2018-05-01 00:00:00

  • Evaluation of CT-based lean-body SUV.

    abstract:PURPOSE:The authors introduce a novel method for defining standardized uptake values (SUVs) in PET∕CT based on routinely collected CT data. The goal of the study is to reduce, if possible, the variability of SUV in a heterogeneous population. Two well established methods for defining SUV are based on body weight (BW) a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4816656

    authors: Hamill JJ,Sunderland JJ,LeBlanc AK,Kojima CJ,Wall J,Martin EB

    更新日期:2013-09-01 00:00:00

  • WE-G-211-02: Origins and Development of Magnetic Resonance Imaging.

    abstract::The method of magnetic resonance imaging (MRI) was an extension of nuclear magnetic resonance (NMR) spectroscopy that was enabled by computational systems capable of performing the Fast Fourier Transform. Initially, a diverse group of methods were proposed for producing images with NMR, with the multi-slice spin-warp ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736176

    authors: Clarke G

    更新日期:2012-06-01 00:00:00

  • Differentiation between diamagnetic and paramagnetic cerebral lesions based on magnetic susceptibility mapping.

    abstract:PURPOSE:Identification of calcifications and hemorrhages is essential for the etiological diagnosis of cerebral lesions. The purpose of this work was to develop a robust method for characterization of para- and diamagnetic intracerebral lesions based on clinical gradient-echo magnetic resonance phase data acquired at 1...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3481505

    authors: Schweser F,Deistung A,Lehr BW,Reichenbach JR

    更新日期:2010-10-01 00:00:00

  • An anthropomorphic torso section phantom for ultrasonic imaging.

    abstract::Using stable materials capable of mimicking any soft tissues of the human body--quantitatively with respect to speed of sound, density, and attenuation coefficient and semiquantitatively with respect to scatter--we have constructed a torso section phantom containing simulated bowel gas, kidney, kidney fat pad, liver, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594657

    authors: Madsen EL,Zagzebski JA,Ghilardi-Netto T

    更新日期:1980-01-01 00:00:00

  • Anatomical pulmonary magnetic resonance imaging segmentation for regional structure-function measurements of asthma.

    abstract:PURPOSE:Pulmonary magnetic-resonance-imaging (MRI) and x-ray computed-tomography have provided strong evidence of spatially and temporally persistent lung structure-function abnormalities in asthmatics. This has generated a shift in their understanding of lung disease and supports the use of imaging biomarkers as inter...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4948999

    authors: Guo F,Svenningsen S,Eddy RL,Capaldi DPI,Sheikh K,Fenster A,Parraga G

    更新日期:2016-06-01 00:00:00

  • Effective and equivalent organ doses in patients undergoing coronary angiography and percutaneous coronary intervention.

    abstract:PURPOSE:Recent recommendations of the International Commission on Radiological Protection state that the use of effective dose (E) for assessing patient exposure has severe limitations, though it can be kept for dose comparisons. In cardiology procedures, the equivalent dose (H(T)) is one of the most appropriate dose q...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3561508

    authors: Compagnone G,Ortolani P,Domenichelli S,Ovi V,Califano G,Dall'Ara G,Marzocchi A

    更新日期:2011-04-01 00:00:00

  • The use of a diode matrix in commissioning activities for electron energies > or = 9 MeV: a feasibility study.

    abstract::The contribution of a commercially available diode matrix (MapCHECK, provided by Sun Nuclear, Melbourne, FL) for the commissioning procedures of the voxel based Monte Carlo (VMC++) algorithm for electron beams of MasterPlan treatment planning system was investigated. The attention is mainly focused on the calculation ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3081414

    authors: Borca VC,Pasquino M,Ozzello F,Tofani S

    更新日期:2009-04-01 00:00:00

  • SU-E-T-635: Effect of Planning Parameters on Tomotherapy Dosimetric Quality and Treatment Efficiency.

    abstract:PURPOSE:To investigate how the setting of optimization parameters, fractional dose and tuning structure in tomotherapy treatment planning affects plan dosimetric quality and treatment efficiency. METHODS:A digital phantom to simulate head and neck radiotherapy was constructed for this study. Tumor was 10cm long C-shap...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735724

    authors: Lian J,Burkhardt K,Chera B,Chang S

    更新日期:2012-06-01 00:00:00

  • Eddy current disruption: effect on nuclear magnetic resonance coil impedance and power loss.

    abstract::We present a theoretical development and experimental verification of a description of power loss and sample resistance for a lossy sample in a nuclear magnetic resonance radio frequency coil for a sample geometry where the eddy current streamlines are disrupted from their usually assumed circular paths. Specifically ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596336

    authors: Harpen MD

    更新日期:1989-09-01 00:00:00

  • Computerized analysis of mammographic microcalcifications in morphological and texture feature spaces.

    abstract::We are developing computerized feature extraction and classification methods to analyze malignant and benign microcalcifications on digitized mammograms. Morphological features that described the size, contrast, and shape of microcalcifications and their variations within a cluster were designed to characterize microc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598389

    authors: Chan HP,Sahiner B,Lam KL,Petrick N,Helvie MA,Goodsitt MM,Adler DD

    更新日期:1998-10-01 00:00:00

  • TU-E-217BCD-07: Pilot Study on Consistency in Size Metrics for a Multimodality PEM/MR Breast Imaging Approach.

    abstract:PURPOSE:In this study, we evaluated the degree of consistency between size metrics obtained from PEM and MRI to determine the intrinsic effectiveness of a multimodality approach using these two systems for breast imaging. METHODS:Under an IRB-approved protocol, 42 cases were considered (16 patients with 28 lesions), e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735979

    authors: Sadinski M,Giger M,Drukker K,Yamaguchi K,Lan L,Li H

    更新日期:2012-06-01 00:00:00

  • An artificial neural network for estimating scatter exposures in portable chest radiography.

    abstract::An adaptive linear element (Adaline) was developed to estimate the two-dimensional scatter exposure distribution in digital portable chest radiographs (DPCXR). DPCXRs and quantitative scatter exposure measurements at 64 locations throughout the chest were acquired for ten radiographically normal patients. The Adaline ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596978

    authors: Lo JY,Floyd CE Jr,Baker JA,Ravin CE

    更新日期:1993-07-01 00:00:00

  • Conceptual design of beryllium targets for the generation of neutron beams for radiation therapy by the (p,n) reaction.

    abstract::A conceptual design is presented showing that, by judiciously choosing the beryllium target thickness and the backstop material, improvements can be achieved in dose-rate, skin sparing, and penetration of neutron beams generated by the same proton accelerator. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594748

    authors: Awschalom M,Rosenberg I

    更新日期:1980-09-01 00:00:00

  • The water-equivalence of phantom materials for 90Sr-90Y beta particles.

    abstract::Intravascular brachytherapy requires that the dose be specified within millimeters of the source. High dose gradients near brachytherapy sources require that the source-detector distance be accurately known for dosimetry purposes. Solid phantoms can be designed to accommodate these stringent requirements. This study r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1376176

    authors: Buckley LA,Thomadsen BR,DeWerd LA

    更新日期:2001-06-01 00:00:00

  • Development of a Monte Carlo multiple source model for inclusion in a dose calculation auditing tool.

    abstract:PURPOSE:The Imaging and Radiation Oncology Core Houston (IROC-H) (formerly the Radiological Physics Center) has reported varying levels of agreement in their anthropomorphic phantom audits. There is reason to believe one source of error in this observed disagreement is the accuracy of the dose calculation algorithms an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12426

    authors: Faught AM,Davidson SE,Fontenot J,Kry SF,Etzel C,Ibbott GS,Followill DS

    更新日期:2017-09-01 00:00:00

  • Determination of x-ray tube focal spot position.

    abstract::In x-ray spectral measurement using a semiconductor detector system, accurate positioning of the detector in front of the anode is very important. This needs accurate determination of the focal spot position on the target in an x-ray tube. We present a simple technique to determine the focal spot position accurately. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597122

    authors: Kubota H,Ozaki Y,Matsumoto M,Kanamori H

    更新日期:1993-07-01 00:00:00