Image-based iterative compensation of motion artifacts in computed tomography.

Abstract:

PURPOSE:This article presents an iterative method for compensation of motion artifacts for slowly rotating computed tomography (CT) systems. Patient's motion introduces inconsistencies among projections and yields severe reconstruction artifacts for free-breathing acquisitions. Streaks and doubling of structures can appear and the resolution is limited by strong blurring. METHODS:The rationale of the proposed motion compensation method is to iteratively correct the reconstructed image by first decomposing the perceived motion in projection space, then reconstructing the motion artifacts in image space, and finally subtracting the artifacts from an initial image. The initial image is reconstructed from the acquired data and might contain motion blur artifacts but, nevertheless, is considered as a reference for estimating the reconstruction artifacts. RESULTS:Qualitative and quantitative figures are shown for experiments based on numerically simulated projections of a sequence of clinical images resulting from a respiratory-gated helical CT acquisition. The border of the diaphragm becomes progressively sharper and the contrast improves for small structures in the lungs. CONCLUSIONS:The originality of the technique stems from the fact that the patient motion is not explicitly estimated but the motion artifacts are reconstructed in image space. This approach could provide sharp static anatomical images on interventional C-arm systems or on slowly rotating X-ray equipments in radiotherapy.

journal_name

Med Phys

journal_title

Medical physics

authors

Schretter C,Rose G,Bertram M

doi

10.1118/1.3244035

subject

Has Abstract

pub_date

2009-11-01 00:00:00

pages

5323-30

issue

11

eissn

0094-2405

issn

2473-4209

journal_volume

36

pub_type

杂志文章
  • Computer-aided detection of breast cancers using Haar-like features in automated 3D breast ultrasound.

    abstract:PURPOSE:Automated 3D breast ultrasound (ABUS) has gained interest in breast imaging. Especially for screening women with dense breasts, ABUS appears to be beneficial. However, since the amount of data generated is large, the risk of oversight errors is substantial. Computer aided detection (CADe) may be used as a secon...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4914162

    authors: Tan T,Mordang JJ,van Zelst J,Grivegnée A,Gubern-Mérida A,Melendez J,Mann RM,Zhang W,Platel B,Karssemeijer N

    更新日期:2015-04-01 00:00:00

  • Characterization of a mammographic system based on single photon counting pixel arrays coupled to GaAs x-ray detectors.

    abstract::The authors report on the imaging capabilities of a mammographic system demonstrator based on GaAs pixel detectors operating in single photon counting (SPC) mode. The system imaging performances have been assessed by means of the transfer functions: The modulation transfer function (MTF), the normalized noise power sp...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3097284

    authors: Amendolia SR,Bisogni MG,Delogu P,Fantacci ME,Paternoster G,Rosso V,Stefanini A

    更新日期:2009-04-01 00:00:00

  • Objective characterization of GE discovery CT750 HD scanner: gemstone spectral imaging mode.

    abstract:PURPOSE:To objectively characterize the performance of the gemstone spectral imaging (GSI) mode of GE CT750 HD scanner from a user's perspective. METHODS:A regular scan protocol that approximates the adult abdomen scan protocol frequently used in the authors' institute was selected as the baseline, and a GSI protocol ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3551999

    authors: Zhang D,Li X,Liu B

    更新日期:2011-03-01 00:00:00

  • Energy dependent calibration of XR-QA2 radiochromic film with monochromatic and polychromatic x-ray beams.

    abstract:PURPOSE:This work investigates the energy response and dose-response curve determinations for XR-QA2 radiochromic film dosimetry system used for synchrotron radiation work and for quality assurance in diagnostic radiology, in the range of effective energies 18-46.5 keV. METHODS:Pieces of XR-QA2 films were irradiated, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4939063

    authors: Di Lillo F,Mettivier G,Sarno A,Tromba G,Tomic N,Devic S,Russo P

    更新日期:2016-01-01 00:00:00

  • Predicting 3D body shape and body composition from conventional 2D photography.

    abstract:PURPOSE:Total and regional body composition are important indicators of health and mortality risk, but their measurement is usually restricted to controlled environments in clinical settings with expensive and specialized equipment. A method that approaches the accuracy of the current gold standard method, dual-energy ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14492

    authors: Tian IY,Ng BK,Wong MC,Kennedy S,Hwaung P,Kelly N,Liu E,Garber AK,Curless B,Heymsfield SB,Shepherd JA

    更新日期:2020-12-01 00:00:00

  • Poster - Thurs Eve-31: Clinical implementation and experience with EPID-based precision isocentre localization.

    abstract::Modern linear accelerators contain multiple isocentres, defined by the mechanical motions of gantry, collimator and table. Isocentre localization for these motions has been performed using film and manual evaluations which have difficulty in relating the individual motions. To address these limitations, we have develo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965950

    authors: Heaton R,Smale J,Norrlinger B,Wang Y,van Prooijen M,Islam M

    更新日期:2008-07-01 00:00:00

  • An investigation of a new amorphous silicon electronic portal imaging device for transit dosimetry.

    abstract::The relationship between the pixel value and exit dose was investigated for a new commercially available amorphous silicon electronic portal imaging device. The pixel to dose mapping function was established to be linear for detector distances between 116.5 cm to 150 cm from the source, radiation field sizes from 5 x ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1508108

    authors: Grein EE,Lee R,Luchka K

    更新日期:2002-10-01 00:00:00

  • Four-dimensional inverse treatment planning with inclusion of implanted fiducials in IMRT segmented fields.

    abstract::The purpose of this study is to develop a 4D inverse planning strategy capable of controlling the appearance of the implanted fiducial(s) in segmented IMRT fields for cine MV or combined MV/kV image-guided IMRT. This work is focused on enhancing the visibility of the implanted fiducial(s) in 4D IMRT inverse planning, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3121425

    authors: Ma Y,Lee L,Keshet O,Keall P,Xing L

    更新日期:2009-06-01 00:00:00

  • Imaging of moving fiducial markers during radiotherapy using a fast, efficient active pixel sensor based EPID.

    abstract:PURPOSE:The purpose of this work was to investigate the use of an experimental complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) for tracking of moving fiducial markers during radiotherapy. METHODS:The APS has an active area of 5.4 × 5.4 cm and maximum full frame read-out rate of 20 frame s(-1),...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3651632

    authors: Osmond JP,Zin HM,Harris EJ,Lupica G,Allinson NM,Evans PM

    更新日期:2011-11-01 00:00:00

  • Dosimetric properties of radiophotoluminescent glass rod detector in high-energy photon beams from a linear accelerator and cyber-knife.

    abstract::A fully automatic radiophotoluminescent glass rod dosimeter (GRD) system has recently become commercially available. This article discusses the dosimetric properties of the GRD including uniformity and reproducibility of signal, dose linearity, and energy and directional dependence in high-energy photon beams. In addi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1758351

    authors: Arakia F,Moribe N,Shimonobou T,Yamashita Y

    更新日期:2004-07-01 00:00:00

  • Radiologic validation of a fast neutron multileaf collimator.

    abstract::Teletherapy with high linear energy transfer radiations (LET), perhaps more than with low LET types, requires careful beam collimation to limit effects to normal structures. Intensity modulated techniques may also hold promise in this regard. Accordingly, a remote computer-controlled, high-resolution multileaf collima...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2760026

    authors: Farr JB,Maughan RL,Yudelev M,Blosser E,Brandon J,Horste T,Forman JD

    更新日期:2007-09-01 00:00:00

  • Primary dose in photon beams with lateral electron disequilibrium.

    abstract::It is shown that in narrow monoenergetic photon beams under conditions of lateral electron disequilibrium, primary absorbed dose P(r) is a simple function of beam radius r: P(r) = P lambda.(1 - e(-gamma.r)), where P lambda is the primary dose in broad beams for which complete lateral electron equilibrium exists, and g...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596741

    authors: Nizin PS,Chang XS

    更新日期:1991-07-01 00:00:00

  • The dosimetric properties of an intraoperative radiation therapy applicator system for a Mevatron-80.

    abstract::An applicator system for intraoperative radiation therapy has been fabricated which does not require physical docking with the accelerator. A dosimetric study has been completed which documents the properties of this system for a variety of electron beam energies, applicator sizes, collimator settings, both primary an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596338

    authors: Nelson CE,Cook R,Rakfal S

    更新日期:1989-09-01 00:00:00

  • Clinical implementation and commissioning of the MedAustron Particle Therapy Accelerator for non-isocentric scanned proton beam treatments.

    abstract:PURPOSE:This paper describes the clinical implementation and medical commissioning of the MedAustron Particle Therapy Accelerator (MAPTA) for non-isocentric scanned proton beam treatments. METHODS:Medical physics involvement during technical commissioning work is presented. Acceptance testing procedures, including adv...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13928

    authors: Grevillot L,Osorio Moreno J,Letellier V,Dreindl R,Elia A,Fuchs H,Carlino A,Kragl G,Palmans H,Vatnitsky S,Stock M

    更新日期:2020-02-01 00:00:00

  • TU-E-BRB-01: Similar-Case-Based Optimization of Beam Arrangements in Stereotactic Body Radiation Therapy.

    abstract:PURPOSE:The quality of a treatment plan for stereotactic body radiotherapy (SBRT) depends on an experience of each treatment planner. Therefore, the treatment plans are subjectively determined by comparison of several treatment plans developed by time consuming iterative manners, while considering the benefit to a tumo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735950

    authors: Magome T,Arimura H,Shioyama Y,Mizoguchi A,Tokunaga C,Nakamura K,Honda H,Ohki M,Toyofuku F,Hirata H

    更新日期:2012-06-01 00:00:00

  • Fast iterative algorithms for three-dimensional inverse treatment planning.

    abstract::Three types of iterative algorithms, algebraic inverse treatment planning (AITP), simultaneous iterative inverse treatment planning (SIITP), and iterative least-square inverse treatment planning (ILSITP), differentiated according to their updating sequences, were generalized to three dimension with true beam geometry ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598374

    authors: Xing L,Hamilton RJ,Spelbring D,Pelizzari CA,Chen GT,Boyer AL

    更新日期:1998-10-01 00:00:00

  • Performance evaluation of computed tomography systems: Summary of AAPM Task Group 233.

    abstract:BACKGROUND:The rapid development and complexity of new x-ray computed tomography (CT) technologies and the need for evidence-based optimization of image quality with respect to radiation and contrast media dose call for an updated approach towards CT performance evaluation. AIMS:This report offers updated testing guid...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13763

    authors: Samei E,Bakalyar D,Boedeker KL,Brady S,Fan J,Leng S,Myers KJ,Popescu LM,Ramirez Giraldo JC,Ranallo F,Solomon J,Vaishnav J,Wang J

    更新日期:2019-11-01 00:00:00

  • SU-E-T-142: Evaluation of the Energy Dependence of Gafchromic EBT3 Film for Electron Beams.

    abstract:PURPOSE:To evaluate the energy dependence of Gafchromic EBT3 film for establishing a quality assurance method of bolus electron conformal radiotherapy. METHODS:We irradiated electron beam to EBT3 films, which were set in the water tank. The linear accelerator used was Varian Clinac 21EX. The energy of electron beams w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735200

    authors: Inoue T,Sugimoto S,Fukata K,Kurokawa C,Ozawa S,Sasai K

    更新日期:2012-06-01 00:00:00

  • Implementation of a quality assurance program for computerized treatment planning systems.

    abstract::In the present investigation, the necessary tests for implementing a quality assurance program for a commercial treatment planning system (TPS), recently installed at Sao Paulo University School of Medicine Clinicas Hospital-Brazil, was established and performed in accordance with the new IAEA publication TRS 430, and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2742779

    authors: Camargo PR,Rodrigues LN,Furnari L,Rubo RA

    更新日期:2007-07-01 00:00:00

  • Reference standard and statistical model for intersite and temporal comparisons of CT attenuation in a multicenter quantitative lung study.

    abstract:PURPOSE:The purpose of this study was to detect and analyze anomalies between a large number of computed tomography (CT) scanners, tracked over time, utilized to collect human pulmonary CT data for a national multicenter study: chronic obstructive pulmonary disease genetic epidemiology study (COPDGene). METHODS:A cust...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4747342

    authors: Sieren JP,Newell JD,Judy PF,Lynch DA,Chan KS,Guo J,Hoffman EA

    更新日期:2012-09-01 00:00:00

  • Effect of beam number on organ-at-risk sparing in dynamic multileaf collimator delivery of intensity modulated radiation therapy.

    abstract::Due to practical limitations such as inter- and intraleaf transmission, nondivergent leaf end design, and leaf scatter, multileaf collimators (MLCs) are unable to accurately produce the ideal fluence patterns generated by inverse planning systems. Consequently, low dose regions receive substantially more radiation tha...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2779862

    authors: Popple RA,Fiveash JB,Brezovich IA

    更新日期:2007-10-01 00:00:00

  • Cascaded systems analysis of shift-variant image quality in slit-scanning breast tomosynthesis.

    abstract:PURPOSE:Digital breast tomosynthesis (DBT) is becoming an important part of breast cancer screening and diagnosis. Compared to two-dimensional mammography, tomosynthesis introduces limited three-dimensional (3D) resolution, but maintains high in-plane resolution, low dose, and allows for similar clinical protocols. The...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13116

    authors: Berggren K,Cederström B,Lundqvist M,Fredenberg E

    更新日期:2018-10-01 00:00:00

  • Thermoluminescent dosimetry of the SourceTech Medical model STM1251 125I seed.

    abstract::Many new models of 125I seeds are being introduced, mainly due to the increase in prostate seed implants. We have evaluated the SourceTech Medical (STM), model STM1251, 125I seed using thermoluminescent dosimeters (TLDs) in a solid water phantom. TLD cubes, LiF TLD-100, with dimension 1 mm on each edge, were irradiate...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1577251

    authors: Chiu-Tsao ST,Duckworth TL,Hsiung CY,Li Z,Williamson J,Patel NS,Harrison LB

    更新日期:2003-07-01 00:00:00

  • Reconstruction of 4-MV bremsstrahlung spectra from measured transmission data.

    abstract::Transmission data for 4-MV bremsstrahlung beams have been measured with a combination of lead and aluminum attenuators. From these data, the original energy spectra have been reconstructed using an iterative least-squares technique, previously evaluated by simulation studies. The spectra on the central axis for three ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595356

    authors: Huang PH,Kase KR,Bjärngard BE

    更新日期:1983-11-01 00:00:00

  • Ultrasonic tissue characterization via 2-D spectrum analysis: theory and in vitro measurements.

    abstract::A theoretical model is described for application in ultrasonic tissue characterization using a calibrated 2-D spectrum analysis method. This model relates 2-D spectra computed from ultrasonic backscatter signals to intrinsic physical properties of tissue microstructures, e.g., size, shape, and acoustic impedance. The ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2436978

    authors: Liu T,Lizzi FL,Ketterling JA,Silverman RH,Kutcher GJ

    更新日期:2007-03-01 00:00:00

  • A survey of the information gained from planning treatment with a computer.

    abstract::We designed a questionnaire to be filled out by the physicist at the time of planning treatment with the aid of a computer in order to assess what was learned during the course of the planning session. We analyzed the results to gauge the impact of the 70 treatment planning sessions conducted during the one month peri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596302

    authors: Doppke KP,Goitein M

    更新日期:1988-03-01 00:00:00

  • Recent progress in x-ray stereoscopes.

    abstract::An improved reconstructed stereoscopic x-ray image display system, based on the principle of binocular parallax, is described. Pulse-synchronized operation of two triode x-ray tubes and one plumbicon TV camera is employed to separate the left and right images for presentation to the two eyes, respectively. The princip...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595365

    authors: Zhang S,King PH,Pang XD

    更新日期:1983-09-01 00:00:00

  • Cascaded-systems analyses and the detective quantum efficiency of single-Z x-ray detectors including photoelectric, coherent and incoherent interactions.

    abstract:PURPOSE:Theoretical models of the detective quantum efficiency (DQE) of x-ray detectors are an important step in new detector development by providing an understanding of performance limitations and benchmarks. Previous cascaded-systems analysis (CSA) models accounted for photoelectric interactions only. This paper des...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4794495

    authors: Yun S,Tanguay J,Kim HK,Cunningham IA

    更新日期:2013-04-01 00:00:00

  • A deep feature fusion methodology for breast cancer diagnosis demonstrated on three imaging modality datasets.

    abstract:BACKGROUND:Deep learning methods for radiomics/computer-aided diagnosis (CADx) are often prohibited by small datasets, long computation time, and the need for extensive image preprocessing. AIMS:We aim to develop a breast CADx methodology that addresses the aforementioned issues by exploiting the efficiency of pre-tra...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12453

    authors: Antropova N,Huynh BQ,Giger ML

    更新日期:2017-10-01 00:00:00

  • A novel and individualized robust optimization method using normalized dose interval volume constraints (NDIVC) for intensity-modulated proton radiotherapy.

    abstract:PURPOSE:Intensity-modulated proton therapy (IMPT) is known to be sensitive to patient setup and range uncertainty issues. Multiple robust optimization methods have been developed to mitigate the impact of these uncertainties. Here, we propose a new robust optimization method, which provides an alternative way of robust...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13276

    authors: Shan J,Sio TT,Liu C,Schild SE,Bues M,Liu W

    更新日期:2019-01-01 00:00:00