Abstract:
BACKGROUND:Deep learning methods for radiomics/computer-aided diagnosis (CADx) are often prohibited by small datasets, long computation time, and the need for extensive image preprocessing. AIMS:We aim to develop a breast CADx methodology that addresses the aforementioned issues by exploiting the efficiency of pre-trained convolutional neural networks (CNNs) and using pre-existing handcrafted CADx features. MATERIALS & METHODS:We present a methodology that extracts and pools low- to mid-level features using a pretrained CNN and fuses them with handcrafted radiomic features computed using conventional CADx methods. Our methodology is tested on three different clinical imaging modalities (dynamic contrast enhanced-MRI [690 cases], full-field digital mammography [245 cases], and ultrasound [1125 cases]). RESULTS:From ROC analysis, our fusion-based method demonstrates, on all three imaging modalities, statistically significant improvements in terms of AUC as compared to previous breast cancer CADx methods in the task of distinguishing between malignant and benign lesions. (DCE-MRI [AUC = 0.89 (se = 0.01)], FFDM [AUC = 0.86 (se = 0.01)], and ultrasound [AUC = 0.90 (se = 0.01)]). DISCUSSION/CONCLUSION:We proposed a novel breast CADx methodology that can be used to more effectively characterize breast lesions in comparison to existing methods. Furthermore, our proposed methodology is computationally efficient and circumvents the need for image preprocessing.
journal_name
Med Physjournal_title
Medical physicsauthors
Antropova N,Huynh BQ,Giger MLdoi
10.1002/mp.12453subject
Has Abstractpub_date
2017-10-01 00:00:00pages
5162-5171issue
10eissn
0094-2405issn
2473-4209journal_volume
44pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:To find an upper bound on the maximum dose reduction possible for any reconstruction algorithm, analytic or iterative, that result from the inclusion of the data statistics. The authors do not analyze noise reduction possible from prior knowledge or assumptions about the object. METHODS:The authors examined th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4941954
更新日期:2016-03-01 00:00:00
abstract:PURPOSE:Potential collision between the patient∕couch and the gantry could delay the start of the treatment and reduce clinical efficiency. The ability to accurately detect possible collisions during the treatment planning phase is desired. Such collision detection should account for the specific proton gantry design, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4760988
更新日期:2012-11-01 00:00:00
abstract:PURPOSE:To compare and evaluate intensity-based registration methods for computation of serial x-ray mammogram correspondence. METHODS:X-ray mammograms were simulated from MRIs of 20 women using finite element methods for modeling breast compressions and employing a MRI/x-ray appearance change model. The parameter con...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3457470
更新日期:2010-09-01 00:00:00
abstract::In proton therapy, it is important to evaluate the field irradiated with protons and the deposited dose distribution in a patient's body. Positron emitters generated through fragmentation reactions of target nuclei can be used for this purpose. By detecting the annihilation gamma rays from the positron emitters, the a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2712572
更新日期:2007-05-01 00:00:00
abstract::We measured the characteristic curve, modulation transfer function (MTF), and the Wiener spectrum of a commercially available computed radiographic (CR) system with photostimulable phosphor plate (imaging plate, IP). The characteristic curve (system response) obtained by an inverse-square x-ray sensitometry showed a w...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596402
更新日期:1989-01-01 00:00:00
abstract:PURPOSE:To evaluate both the Calypso Systems' (Calypso Medical Technologies, Inc., Seattle, WA) localization accuracy in the presence of wireless metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters of dose verification system (DVS, Sicel Technologies, Inc., Morrisville, NC) and the dosimeters' reading...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3578602
更新日期:2011-05-01 00:00:00
abstract:PURPOSE:To evaluate the dose distribution of a 120-MeV laser-plasma accelerated electron beam which may be of potential interest for high-energy electron radiation therapy. METHODS:In the interaction between an intense laser pulse and a helium gas jet, a well collimated electron beam with very high energy is produced....
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4719962
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Dose verification in highly conformal radiation therapy such as IMRT or proton therapy can benefit from the high spatial resolution offered by radio-chromic films such as Gafchromic EBT or EBT2. Recently, a new generation of these films, EBT3, has become available. The composition and thickness of the sensitive...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4737890
更新日期:2012-08-01 00:00:00
abstract::Respiratory motion can introduce significant errors in radiotherapy. Conventional CT scans as commonly used for treatment planning can include severe motion artifacts that result from interplay effects between the advancing scan plane and object motion. To explicitly include organ/target motion in treatment planning a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1869852
更新日期:2005-04-01 00:00:00
abstract::Our purpose in this paper is to present an in vivo dosimetry program designed both for measuring the rectal dose and for avoiding misadministrations in gynecological intracavitary implants. A device containing an energy compensated diode was specially designed for these measurements. Our calibration procedure as well ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598598
更新日期:1999-05-01 00:00:00
abstract::Intraoperative three-dimensional reconstruction of seed locations during prostate brachytherapy for purposes of immediate computation of radiation dosimetry is an active area of current investigation, including methods which use multiple fluoroscopic projections. A simulation study using seed locations extracted from ...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1118/1.1707740
更新日期:2004-05-01 00:00:00
abstract::Manganese (Mn) is an essential nutrient for growth and development. Unfortunately, overexposure can lead to neurological damage, which is manifested as a movement disorder marked by tremors. Preclinical symptoms have been found in populations occupationally exposed to the element, and it is suggested that in late stag...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1517613
更新日期:2002-11-01 00:00:00
abstract:PURPOSE:To develop an automatic knot placement algorithm to enable the use of NonUniform Rational B-Splines (NURBS) in deformable image registration. METHODS:The authors developed a two-step approach to fit a known displacement vector field (DVF). An initial fit was made with uniform knot spacing. The error generated ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3609416
更新日期:2011-08-01 00:00:00
abstract:PURPOSE:The Small Animal Radiation Research Platform (SARRP) has been developed for conformal microirradiation with on-board cone beam CT (CBCT) guidance. The graphics processing unit (GPU)-accelerated Superposition-Convolution (SC) method for dose computation has been integrated into the treatment planning system (TPS...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12862
更新日期:2018-05-01 00:00:00
abstract::Absorbed doses from main charged-particle beams and charged-particle fragments have been measured with high accuracy for particle therapy, but there are few reports for doses from neutron components produced as fragments. This study describes the measurements on neutron doses produced by carbon beams; microdosimetric ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2767933
更新日期:2007-09-01 00:00:00
abstract::A fast method of seed matching and reconstruction in prostate brachytherapy is proposed. Previous approaches have required all seeds to be matched with all other seeds in other projections. The fast cross-projection algorithm for the reconstruction of seeds (Fast-CARS) allows for matching of a given seed with a subset...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1489044
更新日期:2002-07-01 00:00:00
abstract::The absorbed dose values determined with the Exradin and PTW-Markus plane-parallel chambers were compared to the values obtained with the ferrous sulphate dosimetry for a number of the Philips SL25 and the Therac 20 electron beams. For the plane-parallel chambers, the cavity-gas calibration factor Ngaspp, was derived ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597800
更新日期:1996-03-01 00:00:00
abstract:PURPOSE:This paper presents the design of a micro-CT guided small animal robotic needle positioning system. In order to simplify the robotic design and maintain a small targeting error, a novel implementation of the remote center of motion is used in the system. The system has been developed with the objective of achie...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4771958
更新日期:2013-01-01 00:00:00
abstract:PURPOSE:Particle therapy is becoming increasingly available world-wide for precise tumor targeting, its favorable depth dose deposition, and increased biological damage to tumor tissue compared to conventional photon therapy. As demand increases for improved robustness and conformality, next-generation secondary dose c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14417
更新日期:2020-10-01 00:00:00
abstract::Up to the present, the majority of low contrast object evaluations performed on phantom images have been accomplished in a subjective fashion. This is mainly due to the time and effort required to manually measure each radiograph with a densitometer to obtain quantitative results. However, with the development of digi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1543153
更新日期:2003-03-01 00:00:00
abstract::Our purpose in this work is to demonstrate that the efficiency of dose-rate computations in 125I brachytherapy, using multigroup discrete ordinates radiation transport simulations, can be significantly enhanced using broad energy group cross sections without a loss of accuracy. To this end, the DANTSYS multigroup disc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1429238
更新日期:2002-02-01 00:00:00
abstract::The immediate goal of clinically based x-ray-transmission computed tomography (CT) is to provide a measurement of the x-ray linear attenuation coefficient in cross section with the ultimate goal of impacting on patient management and care. To do this with the accuracy needed for clinical goals requires the careful int...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.594381
更新日期:1977-03-01 00:00:00
abstract:PURPOSE:In dose guided radiation therapy, incident fluence is one of the important parameters for both influence verification and dose reconstruction. The objective of this investigation was to develop a method to obtain the incident fluence for dose reconstruction in dose guided radiation therapy (DGRT). METHODS:An i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735593
更新日期:2012-06-01 00:00:00
abstract::Computed tomography is sensitive to changes in the imaged distribution during acquisition of the projection data. Previous investigations have emphasized discrete or discontinuous changes in the imaged object. Recent advances have motivated our investigation of object time-dependence characterized by a continuous func...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594458
更新日期:1978-11-01 00:00:00
abstract::The attenuating properties of several types of lead (Pb)-based and non-Pb radiation shielding materials were studied and a correlation was made of radiation attenuation, materials properties, calculated spectra and ambient dose equivalent. Utilizing the well-characterized x-ray and gamma ray beams at the National Rese...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2426404
更新日期:2007-02-01 00:00:00
abstract::This is an introductory tutorial to the field of microdosimetry. Following a brief historical outline, we review the physics of experimental and theoretical microdosimetry and the application of microdosimetry to radiation biology within the so-called "site" approximation. Modern interpretations of microdosimetry that...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.596616
更新日期:1991-11-01 00:00:00
abstract::Intensity modulated radiation therapy (IMRT) treatment planning typically considers beam optimization and beam delivery as separate tasks. Following optimization, a multi-leaf collimator (MLC) or other beam delivery device is used to generate fluence patterns for patient treatment delivery. Due to limitations and char...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1477230
更新日期:2002-06-01 00:00:00
abstract::We are developing a computer program for automated detection of clustered microcalcifications on mammograms. In this study, we investigated the effectiveness of a signal classifier based on a convolution neural network (CNN) approach for improvement of the accuracy of the detection program. Fifty-two mammograms with c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597428
更新日期:1995-10-01 00:00:00
abstract:PURPOSE:To demonstrate the feasibility of compressed sensing (CS) to accelerate the acquisition of hyperpolarized (HP) 129 Xe multi-b diffusion MRI for quantitative assessments of lung microstructural morphometry. METHODS:Six healthy subjects and six chronic obstructive pulmonary disease (COPD) subjects underwent HP 1...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12944
更新日期:2018-07-01 00:00:00
abstract::Deionized water is commonly used to couple microwave applicators to the patient surface in the administration of local hyperthermia. Profiles of the specific absorption rate (SAR) at 1-cm depth show that deionized water coupling significantly distorts the SAR distributions of the Clini-Therm 915-MHz 10 X 10 and 15 X 1...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595881
更新日期:1986-05-01 00:00:00