Multigroup discrete ordinates modeling of 125I 6702 seed dose distributions using a broad energy-group cross section representation.

Abstract:

:Our purpose in this work is to demonstrate that the efficiency of dose-rate computations in 125I brachytherapy, using multigroup discrete ordinates radiation transport simulations, can be significantly enhanced using broad energy group cross sections without a loss of accuracy. To this end, the DANTSYS multigroup discrete ordinates neutral particle transport code was used to estimate the absorbed dose-rate distributions around an 125I-model 6702 seed in two-dimensional (2-D) cylindrical R-Z geometry for four different problems spanning the geometries found in clinical practice. First, simulations with a high resolution 210 energy groups library were used to analyze the photon flux spectral distribution throughout this set of problems. These distributions were used to design an energy group structure consisting of three broad groups along with suitable weighting functions from which the three-group cross sections were derived. The accuracy of 2-D DANTSYS dose-rate calculations was benchmarked against parallel Monte Carlo simulations. Ray effects were remedied by using the DANTSYS internal first collision source algorithm. It is demonstrated that the 125I primary photon spectrum leads to inappropriate weighting functions. An accuracy of +/-5% is achieved in the four problem geometries considered using geometry-independent three-group libraries derived from either material-specific weighting functions or a single material-independent weighting function. Agreement between Monte Carlo and the three-group DANTSYS calculations, within three standard Monte Carlo deviations, is observed everywhere except for a limited region along the Z axis of rotational symmetry, where ray effects are difficult to mitigate. The three-group DANTSYS calculations are 10-13 times faster than ones with a 210-group cross section library for 125I dosimetry problems. Compared to 2-D EGS4 Monte Carlo calculations, the 3-group DANTSYS simulations are a 100-fold more efficient. Provided that these efficiency gains can be sustained in three-dimensional geometries, the results suggest that discrete ordinates simulations may have the potential to serve as an efficient and accurate dose-calculation algorithm for low-energy brachytherapy treatment planning.

journal_name

Med Phys

journal_title

Medical physics

authors

Daskalov GM,Baker RS,Rogers DW,Williamson JF

doi

10.1118/1.1429238

subject

Has Abstract

pub_date

2002-02-01 00:00:00

pages

113-24

issue

2

eissn

0094-2405

issn

2473-4209

journal_volume

29

pub_type

杂志文章
  • Intensity-modulation radiotherapy using independent collimators: an algorithm study.

    abstract::The purpose of this work is to investigate algorithms for the delivery of intensity-modulated fields using independent collimators (IC). Two heuristic algorithms are proposed to calculate jaw-setting sequences for arbitrary 2D intensity distributions. The first algorithm is based on searching the whole intensity matri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598794

    authors: Dai JR,Hu YM

    更新日期:1999-12-01 00:00:00

  • Patient specific optimization of the relation between CT-hounsfield units and proton stopping power with proton radiography.

    abstract::The purpose of this work is to show the feasibility of using in vivo proton radiography of a radiotherapy patient for the patient individual optimization of the calibration from CT-Hounsfield units to relative proton stopping power. Water equivalent tissue (WET) calibrated proton radiographs of a dog patient treated f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1833041

    authors: Schneider U,Pemler P,Besserer J,Pedroni E,Lomax A,Kaser-Hotz B

    更新日期:2005-01-01 00:00:00

  • Treatment planning algorithm corrections accounting for random setup uncertainties in fractionated stereotactic radiotherapy.

    abstract::A number of relocatable head fixation systems have become commercially available or developed in-house to perform fractionated stereotactic radiotherapy (SRT) treatment. The uncertainty usually quoted for the target repositioning in SRT is over 2 mm, more than twice that of stereotactic radiosurgery (SRS) systems. Thi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598930

    authors: Zavgorodni SF

    更新日期:2000-04-01 00:00:00

  • Traceable micro-CT scaling accuracy phantom for applications requiring exact measurement of distances or volumes.

    abstract:PURPOSE:Volumetric x-ray microcomputed tomography (CT) can be employed in a variety of quantitative research applications such as image-guided interventions or characterization of medical devices. To ensure the highest geometric fidelity of images for these applications, a phantom and image processing algorithm have be...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4752083

    authors: Waring CS,Bax JS,Samarabandu A,Holdsworth DW,Fenster A,Lacefield JC

    更新日期:2012-10-01 00:00:00

  • Dose enhancement in radiotherapy of small lung tumors using inline magnetic fields: A Monte Carlo based planning study.

    abstract:PURPOSE:To report on significant dose enhancement effects caused by magnetic fields aligned parallel to 6 MV photon beam radiotherapy of small lung tumors. Findings are applicable to future inline MRI-guided radiotherapy systems. METHODS:A total of eight clinical lung tumor cases were recalculated using Monte Carlo me...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4938580

    authors: Oborn BM,Ge Y,Hardcastle N,Metcalfe PE,Keall PJ

    更新日期:2016-01-01 00:00:00

  • A randomization approach to handling data scaling in nuclear medicine.

    abstract:PURPOSE:In medical imaging, data scaling is sometimes desired to handle the system complexity, such as uniformity calibration. Since the data are usually saved in short integer, conventional data scaling will first scale the data in floating point format and then truncate or round the floating point data to short integ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3431573

    authors: Bai C,Conwell R,Kindem J

    更新日期:2010-06-01 00:00:00

  • Clinical reference dosimetry: comparison between AAPM TG-21 and TG-51 protocols.

    abstract::We compare the results of absorbed dose determined at reference conditions according to the AAPM TG-21 dose calibration protocol and the new AAPM TG-51 protocol. The AAPM TG-21 protocol for absorbed dose calibration is based on ionization chambers having exposure calibration factors for 60Co gamma rays, N(x). The new ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598999

    authors: Ding GX,Cygler JE,Kwok CB

    更新日期:2000-06-01 00:00:00

  • Performance characteristics of A 150 plastic-equivalent gases in A 150 plastic proportional counters for 14.8-MeV neutrons.

    abstract::Two recently developed A 150 plastic-equivalent gas mixtures have been tested for suitability in proportional counter applications. Methane- and propane-based "tissue-equivalent" gases were also included for comparison purposes. Event-size weighted dose distributions were measured in a 14.8-MeV neutron beam. Resolutio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595536

    authors: DeLuca PM Jr,Schell MC,Pearson DW,Higgins PD,Attix FH

    更新日期:1984-07-01 00:00:00

  • Efficient low-dose CT artifact mitigation using an artifact-matched prior scan.

    abstract:PURPOSE:Low-dose CT has attracted increasing attention due to growing concerns about radiation exposure in medical scans. However, the frugal use of x-ray radiation inevitably reduces the quality of the CT images, introducing artifacts such as noise and streaks which make the reconstructed images difficult to read in c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736528

    authors: Xu W,Mueller K

    更新日期:2012-08-01 00:00:00

  • Toward the combined optimization of dynamic axes (CODA) for stereotactic radiotherapy and radiosurgery using fixed couch trajectories.

    abstract:PURPOSE:To develop a novel system for patient-specific combined optimization of couch, collimator, and gantry angles for use in volumetric modulated arc therapy (VMAT) treatment planning. The system was designed to produce highly compact dose distributions by extensively sampling the 4π space. Automated fixed couch tra...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13887

    authors: MacDonald RL,Syme A,Little B,Ward L,Thomas CG

    更新日期:2020-02-01 00:00:00

  • Diagnostic efficacy of computer extracted image features in optical coherence tomography of the precancerous cervix.

    abstract:PURPOSE:To determine the diagnostic efficacy of optical coherence tomography (OCT) to identify cervical intraepithelial neoplasia (CIN) grade 2 or higher by computer-aided diagnosis (CADx). METHODS:OCT has been investigated as a screening/diagnostic tool in the management of preinvasive and early invasive cancers of t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3523098

    authors: Kang W,Qi X,Tresser NJ,Kareta M,Belinson JL,Rollins AM

    更新日期:2011-01-01 00:00:00

  • MO-D-BRB-11: Out-Of-Field Dose Measurements in Radiotherapy Using Photons and Particles.

    abstract:PURPOSE:Within the European project ALLEGRO (grant agreement no. 231965), the out-of-field dose delivered to a patient when treated with different radiotherapy modalities was investigated. The study compared the dose distribution during photon and particle irradiations both in a water and an anthropomorphic phantom to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735792

    authors: Kaderka R,Durante M,Berger T,Reitz G,Tessa C

    更新日期:2012-06-01 00:00:00

  • SU-E-T-590: Procedure for Verification and Inter-Comparison of IMRT Beam Models.

    abstract:PURPOSE:The implementation of an accurate beam model is an integral part of the commissioning of any planning system. This process is especially challenging in the case of IMRT beam models owing to the complexity of small field sizes and MLC leaf-end and tongue-and-groove effects. The question of how to judge the quali...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735679

    authors: Veltchev I,Fourkal E,Price R,Ma C

    更新日期:2012-06-01 00:00:00

  • DCE-MRI defined subvolumes of a brain metastatic lesion by principle component analysis and fuzzy-c-means clustering for response assessment of radiation therapy.

    abstract:PURPOSE:To develop a pharmacokinetic modelfree framework to analyze the dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) data for assessment of response of brain metastases to radiation therapy. METHODS:Twenty patients with 45 analyzable brain metastases had MRI scans prior to whole brain radiation thera...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4842556

    authors: Farjam R,Tsien CI,Lawrence TS,Cao Y

    更新日期:2014-01-01 00:00:00

  • Performance evaluation of computed tomography systems: Summary of AAPM Task Group 233.

    abstract:BACKGROUND:The rapid development and complexity of new x-ray computed tomography (CT) technologies and the need for evidence-based optimization of image quality with respect to radiation and contrast media dose call for an updated approach towards CT performance evaluation. AIMS:This report offers updated testing guid...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13763

    authors: Samei E,Bakalyar D,Boedeker KL,Brady S,Fan J,Leng S,Myers KJ,Popescu LM,Ramirez Giraldo JC,Ranallo F,Solomon J,Vaishnav J,Wang J

    更新日期:2019-11-01 00:00:00

  • Analysis of fractionation correction methodologies for multiple phase treatment plans in radiation therapy.

    abstract:PURPOSE:Radiation therapy is often delivered by multiple sequential treatment plans. For an accurate radiobiological evaluation of the overall treatment, fractionation corrections to each dose distribution must be applied before summing the three-dimensional dose matrix of each plan since the simpler approach of perfor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4792636

    authors: Mavroidis P,Ferreira BC,Papanikolaou N,Lopes Mdo C

    更新日期:2013-03-01 00:00:00

  • Experimental verification of a technique for predicting scattered radiation transfer: application to low photon energies.

    abstract::It is shown that predictions can be made of scatter-to-primary ratios for a variety of mammographic configurations. The different configurations can be produced by changes in source-detector distance; source-phantom distance; air gap; photon energy; phantom composition, thickness, and cross-sectional area. A detailed ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595807

    authors: Bernstein H,Muntz EP

    更新日期:1986-11-01 00:00:00

  • Assessment of flat panel LCD primary class display performance based on AAPM TG 18 acceptance protocol.

    abstract::The image display is an important component of the Picture Archiving and Communication System (PACS) and of digital imaging in general. In this paper, we assess the display performance of 32 different flat panel LCD devices, in terms of their reflection, luminance response, luminance uniformity, resolution, noise, vei...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1764946

    authors: Jung H,Kim HJ,Kang WS,Yoo SK,Fujioka K,Hasegawa M,Samei E

    更新日期:2004-07-01 00:00:00

  • SU-E-J-170: Clinical Evaluation of Positioning Accuracy of Two Immobilization Devices for Stereotactic Body Radiotherapy Using Cone Beam CT.

    abstract:PURPOSE:To evaluate the patient positioning accuracy and reproducibility of two commercially available immobilization systems for Stereotactic Body Radiotherapy (SBRT) treatment. METHODS:Forty one patients with lung (n=21) or liver (n=20) malignancies were assigned to one of the two immobilization devices: Elekta ster...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735009

    authors: Cao M,Cao N,Cardenes H,Fakiris A,Desrosiers C,Das I

    更新日期:2012-06-01 00:00:00

  • Segmentation of the prostate from suprapubic ultrasound images.

    abstract::We present a technique for semiautomated segmentation of human prostates using suprapubic ultrasound (US) images. In this approach, a speckle reducing anisotropic diffusion (SRAD) is applied to enhance the images and the instantaneous coefficient of variation (ICOV) is utilized for edge detection. Segmentation is acco...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1809791

    authors: Yu Y,Molloy JA,Acton ST

    更新日期:2004-12-01 00:00:00

  • Technical Note: Identification of an optimal electromagnetic sensor for in vivo electromagnetic-tracked scintillation dosimeter for HDR brachytherapy.

    abstract:PURPOSE:Brachytherapy is a treatment modality which delivers large doses of radiation in a reduced number of visits. Since a small number of large dose-per-fraction is administered in high dose rate brachytherapy, ensuring the right dose is delivered is highly critical. In this work, a scintillation detector is coupled...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13508

    authors: Tho D,Beaulieu L

    更新日期:2019-05-01 00:00:00

  • Cumulative sum quality control for calibrated breast density measurements.

    abstract:PURPOSE:Breast density is a significant breast cancer risk factor. Although various methods are used to estimate breast density, there is no standard measurement for this important factor. The authors are developing a breast density standardization method for use in full field digital mammography (FFDM). The approach c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3250842

    authors: Heine JJ,Cao K,Beam C

    更新日期:2009-12-01 00:00:00

  • Effect of phantom voxelization in CT simulations.

    abstract::In computer simulations of x-ray CT systems one can either use continuous geometrical descriptions for phantoms or a voxelized representation. The voxelized approach allows arbitrary phantoms to be defined without being confined to geometrical shapes. The disadvantage of the voxelized approach is that inherent errors ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1461841

    authors: Goertzen AL,Beekman FJ,Cherry SR

    更新日期:2002-04-01 00:00:00

  • Reduction of ring artifacts in CBCT: detection and correction of pixel gain variations in flat panel detectors.

    abstract:PURPOSE:In using flat panel detectors (FPD) for cone beam computed tomography (CBCT), pixel gain variations may lead to structured nonuniformities in projections and ring artifacts in CBCT images. Such gain variations can be caused by change in detector entrance exposure levels or beam hardening, and they are not accou...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4893278

    authors: Altunbas C,Lai CJ,Zhong Y,Shaw CC

    更新日期:2014-09-01 00:00:00

  • Dosimetric problems at low monitor unit settings for scanned and scattering foil electron beams.

    abstract::Electron beam dosimetry at low monitor unit (MU) settings is important for dosimetric applications. Dose linearity, beam flatness, and beam energies were studied at low MU settings with various dose rates for different types of linear accelerators. It is observed that for the scattering foil units, the dose/MU is a sm...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597328

    authors: Das IJ,Harrington JC,Akber SF,Tomer AF,Murray JC,Cheng CW

    更新日期:1994-06-01 00:00:00

  • Limitations of two-dimensional treatment planning programs.

    abstract::Some limitations of conventional two-dimensional computer programs used to plan radiation therapy are presented. These include: a lack of involvement in defining the clinical problem; deficiencies in the algorithms for computing dose; failure to compute dose throughout the volume of interest; an inability to handle tr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595226

    authors: Goitein M

    更新日期:1982-07-01 00:00:00

  • Determining Pion, the correction factor for recombination losses in an ionization chamber.

    abstract::The 1983 AAPM protocol for the determination of absorbed dose from high-energy photon and electron beams recommends using Pion (the reciprocal of collection efficiency), as determined by the two-voltage technique, to correct for recombination losses in ionization chambers. Methods and data for the determination of ion...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595574

    authors: Weinhous MS,Meli JA

    更新日期:1984-11-01 00:00:00

  • Dosimetric verification of helical tomotherapy for total scalp irradiation.

    abstract::Total scalp irradiation is a treatment technique used for a variety of superficial malignancies. Helical tomotherapy is an effective technique used for total scalp irradiation. Recent published work has shown the TomoTherapy planning system to overestimate the superficial dose. In this study, the superficial doses for...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2996288

    authors: Hardcastle N,Soisson E,Metcalfe P,Rosenfeld AB,Tome WA

    更新日期:2008-11-01 00:00:00

  • Proton magnetic resonance spectroscopy in the brain: report of AAPM MR Task Group #9.

    abstract::AAPM Magnetic Resonance Task Group #9 on proton magnetic resonance spectroscopy (MRS) in the brain was formed to provide a reference document for acquiring and processing proton (1H) MRS acquired from brain tissue. MRS is becoming a common adjunct to magnetic resonance imaging (MRI), especially for the differential di...

    journal_title:Medical physics

    pub_type: 指南,杂志文章,实务指引,评审

    doi:10.1118/1.1501822

    authors: Drost DJ,Riddle WR,Clarke GD,AAPM MR Task Group #9.

    更新日期:2002-09-01 00:00:00

  • A filtering method for signal equalization in region-of-interest fluoroscopy.

    abstract::A method to significantly reduce the exposure area product in fluoroscopy using a pre-patient region-of-interest (ROI) attenuator is presented. The attenuator has a thin central region and a gradually increasing thickness away from the center. It is shown that the unwanted brightening artifact caused by the attenuator...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1470205

    authors: Robert N,Komljenovic PT,Rowlands JA

    更新日期:2002-05-01 00:00:00