Abstract:
PURPOSE:Breast density is a significant breast cancer risk factor. Although various methods are used to estimate breast density, there is no standard measurement for this important factor. The authors are developing a breast density standardization method for use in full field digital mammography (FFDM). The approach calibrates for interpatient acquisition technique differences. The calibration produces a normalized breast density pixel value scale. The method relies on first generating a baseline (BL) calibration dataset, which required extensive phantom imaging. Standardizing prospective mammograms with calibration data generated in the past could introduce unanticipated error in the standardized output if the calibration dataset is no longer valid. METHODS:Sample points from the BL calibration dataset were imaged approximately biweekly over an extended timeframe. These serial samples were used to evaluate the BL dataset reproducibility and quantify the serial calibration accuracy. The cumulative sum (Cusum) quality control method was used to evaluate the serial sampling. RESULTS:There is considerable drift in the serial sample points from the BL calibration dataset that is x-ray beam dependent. Systematic deviation from the BL dataset caused significant calibration errors. This system drift was not captured with routine system quality control measures. Cusum analysis indicated that the drift is a sign of system wear and eventual x-ray tube failure. CONCLUSIONS:The BL calibration dataset must be monitored and periodically updated, when necessary, to account for sustained system variations to maintain the calibration accuracy.
journal_name
Med Physjournal_title
Medical physicsauthors
Heine JJ,Cao K,Beam Cdoi
10.1118/1.3250842subject
Has Abstractpub_date
2009-12-01 00:00:00pages
5380-90issue
12eissn
0094-2405issn
2473-4209journal_volume
36pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:To compare organ specific cancer incidence risks for standard and complex external beam radiotherapy (including cone beam CT verification) following breast conservation surgery for early breast cancer. METHOD:Doses from breast radiotherapy and kilovoltage cone beam CT (CBCT) exposures were obtained from thermo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4748332
更新日期:2012-10-01 00:00:00
abstract:PURPOSE:The use of 4D computed tomography (4D-CT) of the lung is important in lung cancer radiotherapy for tumor localization and treatment planning. Sometimes, dense sampling is not acquired along the superior-inferior direction. This disadvantage results in an interslice thickness that is much greater than in-plane v...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4899185
更新日期:2014-11-01 00:00:00
abstract:PURPOSE:The collimator monitoring fill factor (CM-FF) introduced by Stelljes et al. (2017) and the FWHM fill factor (FWHM-FF) introduced by Gago-Arias et al. (2012) were determined using the measured photon fluence response functions of various 2D-arrays. The error detection capabilities of 2D-arrays were studied by co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13417
更新日期:2019-04-01 00:00:00
abstract:PURPOSE:Developed herein is a three-dimensional (3D) flow contrast imaging system leveraging advancements in the extension of laser speckle contrast imaging theories to deep tissues along with our recently developed finite-element diffuse correlation tomography (DCT) reconstruction scheme. This technique, termed speckl...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4922206
更新日期:2015-07-01 00:00:00
abstract::Nowadays, digital subtraction angiography systems must be able to sustain real-time acquisition (30 frames per second) of 512 x 512 x 8 bit images and store several sequences of such images on low cost and general-purpose mass memories. Concretely, that means a 7.8 Mbytes per second rate and about 780 Mbytes disk spac...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596309
更新日期:1989-11-01 00:00:00
abstract::The purposes of this study are: (i) to design field flattening filters for the Leipzig applicators of 2 and 3 cm of inner diameter with the source traveling parallel to the applicator contact surface, which are accessories of the microSelectron-HDR afterloader (Nucletron, Veenendaal, The Netherlands). These filters, m...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2825622
更新日期:2008-02-01 00:00:00
abstract:BACKGROUND:The rapid development and complexity of new x-ray computed tomography (CT) technologies and the need for evidence-based optimization of image quality with respect to radiation and contrast media dose call for an updated approach towards CT performance evaluation. AIMS:This report offers updated testing guid...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13763
更新日期:2019-11-01 00:00:00
abstract:PURPOSE:Since the introduction of clinical x-ray phase-contrast mammography (PCM), a technique that exploits refractive-index variations to create edge enhancement at tissue boundaries, a number of optimization studies employing physical image-quality metrics have been performed. Ideally, task-based assessment of PCM w...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3676183
更新日期:2012-02-01 00:00:00
abstract::Small photon fields are increasingly used in modern radiotherapy and especially in IMRT and SRS/SRT treatments. The uncertainties related to small field profile measurements can introduce significant systematic errors to the overall treatment process. These measurements are challenging mainly due to the absence of cha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2977829
更新日期:2008-10-01 00:00:00
abstract:PURPOSE:The most common metric for comparing measured to calculated dose planes is a pass rate generated using percent difference, distance-to-agreement (DTA), or some combination of the two (e.g. gamma evaluation). The grid of analyzed points often corresponds to a dosimeter array with low areal-density of point detec...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735070
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Variations during breast tissue development can influence later breast cancer risk. In particular, prolonged nulliparity increases risk. The authors used optical spectroscopy to compare breast tissue in 115 nulliparous women aged 31-40 (group 2) to 140 nulliparous women aged 18-21 (group 1), and also to 36 paro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3276737
更新日期:2010-02-01 00:00:00
abstract::In this paper, two new boundary tracing algorithms for segmentation of breast masses are presented. These new algorithms are based on the dynamic programming-based boundary tracing (DPBT) algorithm proposed in Timp and Karssemeijer, [S. Timp and N. Karssemeijer, Med. Phys. 31, 958-971 (2004)] The DPBT algorithm contai...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2791034
更新日期:2007-11-01 00:00:00
abstract:PURPOSE:The depth dose of a monoenergetic broad parallel proton beam has been modeled in a number of ways, but evidently not yet for oblique incidence. The purpose of this investigation is to find an accurate analytic formula for this case, which can then be used to model the depth dose of a broad beam with an initial ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3495969
更新日期:2010-11-01 00:00:00
abstract:PURPOSE:To develop and evaluate the impact on lesion conspicuity of a software-based x-ray scatter correction algorithm for digital breast tomosynthesis (DBT) imaging into which a precomputed library of x-ray scatter maps is incorporated. METHODS:A previously developed model of compressed breast shapes undergoing mamm...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4866229
更新日期:2014-03-01 00:00:00
abstract:PURPOSE:Accurate calculation of proton stopping power ratio (SPR) relative to water is crucial to proton therapy treatment planning, since SPR affects prediction of beam range. Current standard practice derives SPR using a single CT scan. Recent studies showed that dual-energy CT (DECT) offers advantages to accurately ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12796
更新日期:2018-04-01 00:00:00
abstract::Using stable materials capable of mimicking any soft tissues of the human body--quantitatively with respect to speed of sound, density, and attenuation coefficient and semiquantitatively with respect to scatter--we have constructed a torso section phantom containing simulated bowel gas, kidney, kidney fat pad, liver, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594657
更新日期:1980-01-01 00:00:00
abstract::For an effective radiotherapy the exact tumor location must be determined. The localization has to take into account patient's setup position as well as internal organ motion. Among the different localization methods, the use of a computer tomography (CT) scanner in the therapy room has been proposed recently. Achievi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2103447
更新日期:2005-11-01 00:00:00
abstract::The purpose of this study was to implement the Monte Carlo method for clinical radiotherapy dose calculations. We used the EGS4/BEAM code to obtain the phase-space data for 6-20 MeV electron beams and 4, 6, and 15 MV photon beams for Varian Clinac 1800, 2100C, and 2300CD accelerators. A multiple-source model was used ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598729
更新日期:1999-10-01 00:00:00
abstract:PURPOSE:To develop a new scintillating fiber-based electronic portal imaging device (EPID) with a high quantum efficiency (QE) while preserving an adequate spatial resolution. METHODS:Two prototypes were built: one with a single pixel readout and the other with an active matrix flat-panel imager (AMFPI) for readout. T...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13900
更新日期:2020-01-01 00:00:00
abstract:PURPOSE:The management of thoracic malignancies with radiation therapy is complicated by continuous target motion. In this study, a real time motion analysis approach is proposed to improve the accuracy of patient setup. METHODS:For 11 lung cancer patients a long training fluoroscopy was acquired before the first trea...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1118/1.4794489
更新日期:2013-04-01 00:00:00
abstract:PURPOSE:To develop a real-time markerless 3D tumor tracking using kilovoltage (kV) cone-beam CT (CBCT) projection images during volumetric modulated arc therapy (VMAT) treatment of lung tumors. METHODS:The authors have developed a method to identify the position of lung tumors during VMAT treatment, where the current ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4821545
更新日期:2013-10-01 00:00:00
abstract::The large variation of x-ray fluence at the detector in cone-beam CT (CBCT) poses a significant challenge to detectors' limited dynamic range, resulting in the loss of skinline as well as reduction of CT number accuracy, contrast-to-noise ratio, and image uniformity. The authors investigate the performance of a bowtie...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3017470
更新日期:2009-01-01 00:00:00
abstract:PURPOSE:The paper presents a complete computer-aided detection (CAD) system for the detection of lung nodules in computed tomography images. A new mixed feature selection and classification methodology is applied for the first time on a difficult medical image analysis problem. METHODS:The CAD system was trained and t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3633941
更新日期:2011-10-01 00:00:00
abstract::The accuracy of interpolation or averaging procedures for obtaining the calibration coefficient N(K) for 192Ir high-dose-rate brachytherapy sources has been investigated using the EGSnrc Monte Carlo simulation system. It is shown that the widely used two-point averaging procedure of Goetsch et al. [Med. Phys. 18, 462 ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2239198
更新日期:2006-09-01 00:00:00
abstract:PURPOSE:Dynamic 18 F-FDG PET allows quantitative estimation of cerebral glucose metabolism both at the regional and local (voxel) level. Although sensitive to noise and highly computationally expensive, nonlinear least-squares (NLS) optimization stands as the reference approach for the estimation of the kinetic model p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13366
更新日期:2019-03-01 00:00:00
abstract::Vessel size measurement is perhaps the most often performed quantitative analysis in diagnostic and interventional angiography. Although automated vessel sizing techniques are generally considered to have good accuracy and precision, we have observed that clinicians rarely use these techniques in standard clinical pra...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1562491
更新日期:2003-04-01 00:00:00
abstract::Interchange or transfer of radiographic techniques through measurement of penetration quality is discussed. The usefulness of this achievement is verified using an aluminum step wedge. Also, the procedure described provides a method for performance evaluation of kVp compensation on diagnostic x-ray installations. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594156
更新日期:1975-01-01 00:00:00
abstract::For radiation dosimetry calculations of radiolabeled monoclonal antibodies, (MAB), pharmacokinetics are critical. Specifically, pharmacokinetic modeling is a useful component of estimation of cumulated activity in various source organs in the body. It is thus important to formulate general methods of pharmacokinetic m...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.597047
更新日期:1993-03-01 00:00:00
abstract::An easy-to-use phantom has been constructed for checking the accuracy of a stereotactic computed tomography localization system. This phantom has been used on a commercially available stereotactic radiosurgery system. With this system, the phantom reference point, whose location is established by means of a precision ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597034
更新日期:1993-03-01 00:00:00
abstract::An integrating solid-state dosimeter has been developed to detect ultraviolet radiation using the process of "direct" ultraviolet stimulation. This process yields a thermoluminescent signal after an exposure to ultraviolet radiation, without prior exposure to ionizing radiation. Magnesium oxide crystals were found to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594259
更新日期:1976-11-01 00:00:00