Patient specific optimization of the relation between CT-hounsfield units and proton stopping power with proton radiography.

Abstract:

:The purpose of this work is to show the feasibility of using in vivo proton radiography of a radiotherapy patient for the patient individual optimization of the calibration from CT-Hounsfield units to relative proton stopping power. Water equivalent tissue (WET) calibrated proton radiographs of a dog patient treated for a nasal tumor were used as baseline in comparison with integrated proton stopping power through the calibrated CT of the dog. In an optimization procedure starting with a stoichiometric calibration curve, the calibration was modified randomly. The result of this iteration is an optimized calibration curve which was used to recalculate the dose distribution of the patient. One result of this experiment was that the mean value of the deviations between WET calculations based on the stoichiometric calibration curve and the measurements was shifted systematically away from zero. The calibration produced by the optimization procedure reduced this shift to around 0.4 mm. Another result was that the precision of the calibration, reflected as the standard deviation of the normally distributed deviations between WET calculation and measurement, could be reduced from 7.9 to 6.7 mm with the optimized calibration. The dose distributions based on the two calibration curves showed major deviations at the distal end of the target volume.

journal_name

Med Phys

journal_title

Medical physics

authors

Schneider U,Pemler P,Besserer J,Pedroni E,Lomax A,Kaser-Hotz B

doi

10.1118/1.1833041

subject

Has Abstract

pub_date

2005-01-01 00:00:00

pages

195-9

issue

1

eissn

0094-2405

issn

2473-4209

journal_volume

32

pub_type

杂志文章
  • A Monte Carlo estimation of effective dose in chest tomosynthesis.

    abstract:PURPOSE:The recent introduction of digital tomosynthesis imaging into routine clinical use has enabled the acquisition of volumetric patient data within a standard radiographic examination. Tomosynthesis requires the acquisition of multiple projection views, requiring additional dose compared to a standard projection e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3250907

    authors: Sabol JM

    更新日期:2009-12-01 00:00:00

  • Measurement of primary bremsstrahlung spectrum from an 8-MeV linear accelerator.

    abstract::The bremsstrahlung spectrum from an 8-MeV linear accelerator has been measured using a NaI(T1) spectrometer system. The spectrum shows a low-energy cutoff at 0.4 MeV and the maximum photon energy to be approximately 6% greater than the nominal energy. The maximum emission of energy fluence was 1.6 and 1.8 MeV for meas...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594221

    authors: Levy LB,Waggener RG,Wright AE

    更新日期:1976-05-01 00:00:00

  • Detector dose response in megavoltage small photon beams. II. Pencil beam perturbation effects.

    abstract:PURPOSE:To quantify detector perturbation effects in megavoltage small photon fields and support the theoretical explanation on the nature of quality correction factors in these conditions. METHODS:In this second paper, a modern approach to radiation dosimetry is defined for any detector and applied to small photon fi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4930798

    authors: Bouchard H,Kamio Y,Palmans H,Seuntjens J,Duane S

    更新日期:2015-10-01 00:00:00

  • Direct-conversion flat-panel imager with avalanche gain: feasibility investigation for HARP-AMFPI.

    abstract::The authors are investigating the concept of a direct-conversion flat-panel imager with avalanche gain for low-dose x-ray imaging. It consists of an amorphous selenium (a-Se) photoconductor partitioned into a thick drift region for x-ray-to-charge conversion and a relatively thin region called high-gain avalanche rush...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.3002314

    authors: Wronski MM,Rowlands JA

    更新日期:2008-12-01 00:00:00

  • Automatic learning-based beam angle selection for thoracic IMRT.

    abstract:PURPOSE:The treatment of thoracic cancer using external beam radiation requires an optimal selection of the radiation beam directions to ensure effective coverage of the target volume and to avoid unnecessary treatment of normal healthy tissues. Intensity modulated radiation therapy (IMRT) planning is a lengthy process...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4908000

    authors: Amit G,Purdie TG,Levinshtein A,Hope AJ,Lindsay P,Marshall A,Jaffray DA,Pekar V

    更新日期:2015-04-01 00:00:00

  • Selecting beam weight and wedge filter on the basis of dose gradient analysis.

    abstract::This study proposes an algorithm for selecting beam weight, wedge angle, and wedge orientation for three-dimensional radiation therapy treatment planning. According to dose gradient analysis, the necessary and sufficient condition for achieving a homogeneous dose over the target volume is that the total vector sum of ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1286591

    authors: Dai J,Zhu Y

    更新日期:2000-08-01 00:00:00

  • MO-F-BRCD-01: Stereotactic Body Radiation Therapy: Updates on Clinical, Biological, and Physics/QA:SBRT (Part 1): Biological and Clinical Updates.

    abstract::Stereotactic Body Radiation Therapy (SBRT) is an important form of cancer therapy with increasingly broad application across a spectrum of tumor types in primary and metastatic settings. In this presentation the radiation biology, clinical experience from various trials, and cautionary updates on normal tissue toleran...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735812

    authors: Read P

    更新日期:2012-06-01 00:00:00

  • Fully automatic deformable registration of pretreatment MRI/CT for image-guided prostate radiotherapy planning.

    abstract:PURPOSE:In prostate radiotherapy, dose distribution may be calculated on CT images, while the MRI can be used to enhance soft tissue visualization. Therefore, a registration between MR and CT images could improve the overall treatment planning process, by improving visualization with a demonstrated interobserver deline...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12629

    authors: Hamdan I,Bert J,Rest CCL,Tasu JP,Boussion N,Valeri A,Dardenne G,Visvikis D

    更新日期:2017-12-01 00:00:00

  • Compressed sensing for longitudinal MRI: An adaptive-weighted approach.

    abstract:PURPOSE:Repeated brain MRI scans are performed in many clinical scenarios, such as follow up of patients with tumors and therapy response assessment. In this paper, the authors show an approach to utilize former scans of the patient for the acceleration of repeated MRI scans. METHODS:The proposed approach utilizes the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4928148

    authors: Weizman L,Eldar YC,Ben Bashat D

    更新日期:2015-09-01 00:00:00

  • Radiofrequency penetration and absorption in the human body: limitations to high-field whole-body nuclear magnetic resonance imaging.

    abstract::This study presents experimental results about the effective depth of penetration and about the radiofrequency (rf) power absorption in humans as a function of frequency. The frequency range investigated covers 10 up to 220 MHz. For the main part, the results were derived from bench measurements of the quality factor ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595995

    authors: Röschmann P

    更新日期:1987-11-01 00:00:00

  • Regularization strategies in statistical image reconstruction of low-dose x-ray CT: A review.

    abstract::Statistical image reconstruction (SIR) methods have shown potential to substantially improve the image quality of low-dose x-ray computed tomography (CT) as compared to the conventional filtered back-projection (FBP) method. According to the maximum a posteriori (MAP) estimation, the SIR methods are typically formulat...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.13123

    authors: Zhang H,Wang J,Zeng D,Tao X,Ma J

    更新日期:2018-10-01 00:00:00

  • Combined mixed approach algorithm for in-line phase-contrast x-ray imaging.

    abstract:PURPOSE:In the past decade, phase-contrast imaging (PCI) has been applied to study different kinds of tissues and human body parts, with an increased improvement of the image quality with respect to simple absorption radiography. A technique closely related to PCI is phase-retrieval imaging (PRI). Indeed, PCI is an ima...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3447727

    authors: De Caro L,Scattarella F,Giannini C,Tangaro S,Rigon L,Longo R,Bellotti R

    更新日期:2010-07-01 00:00:00

  • Branch order regression for modeling brain vasculature.

    abstract:PURPOSE:Many biological objects, including neuronal dendrites, blood vasculature, airways, phylogenetic trees, produce tree structured data. Current methods of analysis either ignore the complex structure of trees or use distance-based methods which limit the scope of multivariate modeling. METHODS:We propose a branch...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12751

    authors: Roy Choudhury K,Skwerer S

    更新日期:2018-03-01 00:00:00

  • Potential increase in biological effectiveness from field timing optimization for stereotactic body radiation therapy.

    abstract:PURPOSE:Stereotactic body radiation therapy (SBRT) is a radiotherapy technique which uses high dose fractions with multiple coplanar and noncoplanar beams. Due to the large fractional doses, treatments are typically protracted and there are more fields than in conventional radiation treatment schemes. The effect of tem...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4709605

    authors: Schmitt JD,Warren GW,Wang IZ

    更新日期:2012-06-01 00:00:00

  • An optimized ultrasound detector for photoacoustic breast tomography.

    abstract:PURPOSE:Photoacoustic imaging has proven to be able to detect vascularization-driven optical absorption contrast associated with tumors. In order to detect breast tumors located a few centimeter deep in tissue, a sensitive ultrasound detector is of crucial importance for photoacoustic mammography. Further, because the ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4792462

    authors: Xia W,Piras D,van Hespen JC,van Veldhoven S,Prins C,van Leeuwen TG,Steenbergen W,Manohar S

    更新日期:2013-03-01 00:00:00

  • Practical cone-beam lambda tomography.

    abstract::As a potentially important technology for medical x-ray computed tomography (CT), lambda tomography (LT) is to reconstruct a gradient-like image only from local projection data. Based on our recently derived exact fan-beam LT formula, [H. Y. Gu and G. Wang, Int. J. Biomed. Imaging 2006(1), 1-9 (2006)] here we propose ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2348767

    authors: Yu H,Ye Y,Wang G

    更新日期:2006-10-01 00:00:00

  • A Laplace transform pair model for spectral reconstruction.

    abstract::A four-parameter Laplace transform pair model, which accurately reconstructs an experimental bremsstrahlung spectrum from attenuation data, is presented. Computed spectral values with both aluminum and copper attenuators generally agree with experimental 70-kVp data to better than 2%. Reconstructed spectra at other kV...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595193

    authors: Archer BR,Wagner LK

    更新日期:1982-11-01 00:00:00

  • Sheet beam x-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticles.

    abstract:PURPOSE:X-ray fluorescence computed tomography (XFCT) experiments have typically used pencil beams for data acquisition, which yielded good quality images of gold nanoparticles (AuNP) but prolonged the imaging time. Here we propose three novel collimator geometries for use with faster sheet beam XFCT data acquisition. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12893

    authors: Dunning CAS,Bazalova-Carter M

    更新日期:2018-06-01 00:00:00

  • Bremsstrahlung production at 50 MeV in different target materials and configurations.

    abstract::A combination of Monte Carlo, convolution, and experimental techniques have been used to investigate bremsstrahlung production at 50 MeV in full-range targets to produce narrow elementary photon beams for scanning. Calculations using the ITS 3.0 Monte Carlo system for various target designs, including particle transpo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597681

    authors: Sätherberg A,Andreo P,Karlsson M

    更新日期:1996-04-01 00:00:00

  • WE-G-BRB-03: On the Detectability of Jaw Decalibrations with the DAVID System.

    abstract:PURPOSE:To evaluate if the recently described problems with the calibration of jaws at Varian linear accelerators can be detected with the DAVID system. METHODS:Recently Varian Clinac field size issues resulted in a widespread medical device correction notice, stating that incorrect jaw positioning due to excessive co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736189

    authors: Poppe B,Looe H,Harder D

    更新日期:2012-06-01 00:00:00

  • An evaluation of ionization chambers for the relative dosimetry of kilovoltage x-ray beams.

    abstract::In this work, the authors have evaluated ten different ionization chambers for the relative dosimetry of kilovoltage x-ray beams in the energy range of 50-280 kVp. Percentage depth doses in water and relative detector response (in Solid Water and in air) were measured for each of the x-ray beams studied using a number...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3183820

    authors: Hill R,Mo Z,Haque M,Baldock C

    更新日期:2009-09-01 00:00:00

  • Anisotropy functions for 103Pd, 125I, and 192Ir interstitial brachytherapy sources.

    abstract::Anisotropy of dose distributions around 103Pd, 125I, and 192Ir sources for interstitial brachytherapy was examined. Dose rates around 125I models 6702 and 6711 and 192Ir sources were measured using lithium fluoride thermoluminescence dosimeters (LiF TLDs) in a water-equivalent, solid phantom. From these measured data ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597110

    authors: Nath R,Meigooni AS,Muench P,Melillo A

    更新日期:1993-09-01 00:00:00

  • Reduction of peak acoustic pressure and shaping of heated region by use of multifoci sonications in MR-guided high-intensity focused ultrasound mediated mild hyperthermia.

    abstract:PURPOSE:Ablative hyperthermia (>55 °C) has been used as a definitive treatment for accessible solid tumors not amenable to surgery, whereas mild hyperthermia (40-45 °C) has been shown effective as an adjuvant for both radiotherapy and chemotherapy. An optimal mild hyperthermia treatment is spatially accurate, with prec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4769116

    authors: Partanen A,Tillander M,Yarmolenko PS,Wood BJ,Dreher MR,Kohler MO

    更新日期:2013-01-01 00:00:00

  • Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging.

    abstract:PURPOSE:The possible clinical applications which can be performed using a newly developed detector depend on the detector's characteristic performance in a number of metrics including the dynamic range, resolution, uniformity, and stability. The authors have evaluated a prototype energy resolved fast photon counting x-...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4892174

    authors: Cho HM,Barber WC,Ding H,Iwanczyk JS,Molloi S

    更新日期:2014-09-01 00:00:00

  • Design and optimization of large area thin-film CdTe detector for radiation therapy imaging applications.

    abstract:PURPOSE:The authors investigate performance of thin-film cadmium telluride (CdTe) in detecting high-energy (6 MV) x rays. The utilization of this material has become technologically feasible only in recent years due to significant development in large area photovoltaic applications. METHODS:The CdTe film is combined w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3438082

    authors: Parsai EI,Shvydka D,Kang J

    更新日期:2010-08-01 00:00:00

  • MOSFET dosimetry for microbeam radiation therapy at the European Synchrotron Radiation Facility.

    abstract::Preclinical experiments are carried out with approximately 20-30 microm wide, approximately 10 mm high parallel microbeams of hard, broad-"white"-spectrum x rays (approximately 50-600 keV) to investigate microbeam radiation therapy (MRT) of brain tumors in infants for whom other kinds of radiotherapy are inadequate an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1562169

    authors: Bräuer-Krisch E,Bravin A,Lerch M,Rosenfeld A,Stepanek J,Di Michiel M,Laissue JA

    更新日期:2003-04-01 00:00:00

  • Incorporation of treatment plan spatial and temporal dose patterns into a prostate intrafractional motion management strategy.

    abstract:PURPOSE:Periodic MV∕KV radiographs taken during volumetric modulated arc therapy (VMAT) for hypofractionated treatment provide guidance in intrafractional motion management. The choice of imaging frequency and timing are key components in delivering the desired dose while reducing associated overhead such as imaging do...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4742846

    authors: Zhang P,Hunt M,Happersett L,Cox B,Mageras G

    更新日期:2012-09-01 00:00:00

  • Characterization of a two-dimensional liquid-filled ion chamber detector array used for verification of the treatments in radiotherapy.

    abstract:PURPOSE:The purpose of the study is to investigate the characteristics of a two-dimensional (2D) liquid-filled ion chamber detector array, which is used for the verification of radiotherapy treatment plans that use small field sizes of up to 10 × 10 cm. METHODS:The device used in this study was Octavius 1000 SRS model...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4870439

    authors: Markovic M,Stathakis S,Mavroidis P,Jurkovic IA,Papanikolaou N

    更新日期:2014-05-01 00:00:00

  • Development of optical process for accessing three-dimensional patient topology.

    abstract::A commercial optical system developed by Solid Photography, Inc., has been used to generate precise paraffin--polyethylene tissue compensators. A program with the objective of constructing a medical facility has been undertaken to access patient topology for treatment planning, tissue-compensator fabrication, and pati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594447

    authors: Lerch IA,Barish RJ,Stern H

    更新日期:1978-11-01 00:00:00

  • Interplay effect on a 6-MV flattening-filter-free linear accelerator with high dose rate and fast multi-leaf collimator motion treating breast and lung phantoms.

    abstract:PURPOSE:Using a new linear accelerator with high dose rate (800 MU/min), fast MLC motions (5.0 cm/s), fast gantry rotation (15 s/rotation), and 1 cm wide MLCs, we aimed to quantify the effects of complexity, arc number, and fractionation on interplay for breast and lung treatments under target motion. METHODS:To study...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12899

    authors: Netherton T,Li Y,Nitsch P,Shaitelman S,Balter P,Gao S,Klopp A,Muruganandham M,Court L

    更新日期:2018-06-01 00:00:00