Detector dose response in megavoltage small photon beams. II. Pencil beam perturbation effects.

Abstract:

PURPOSE:To quantify detector perturbation effects in megavoltage small photon fields and support the theoretical explanation on the nature of quality correction factors in these conditions. METHODS:In this second paper, a modern approach to radiation dosimetry is defined for any detector and applied to small photon fields. Fano's theorem is adapted in the form of a cavity theory and applied in the context of nonstandard beams to express four main effects in the form of perturbation factors. The pencil-beam decomposition method is detailed and adapted to the calculation of perturbation factors and quality correction factors. The approach defines a perturbation function which, for a given field size or beam modulation, entirely determines these dosimetric factors. Monte Carlo calculations are performed in different cavity sizes for different detection materials, electron densities, and extracameral components. RESULTS:Perturbation effects are detailed with calculated perturbation functions, showing the relative magnitude of the effects as well as the geometrical extent to which collimating or modulating the beam impacts the dosimetric factors. The existence of a perturbation zone around the detector cavity is demonstrated and the approach is discussed and linked to previous approaches in the literature to determine critical field sizes. CONCLUSIONS:Monte Carlo simulations are valuable to describe pencil beam perturbation effects and detail the nature of dosimetric factors in megavoltage small photon fields. In practice, it is shown that dosimetric factors could be avoided if the field size remains larger than the detector perturbation zone. However, given a detector and beam quality, a full account for the detector geometry is necessary to determine critical field sizes.

journal_name

Med Phys

journal_title

Medical physics

authors

Bouchard H,Kamio Y,Palmans H,Seuntjens J,Duane S

doi

10.1118/1.4930798

subject

Has Abstract

pub_date

2015-10-01 00:00:00

pages

6048-61

issue

10

eissn

0094-2405

issn

2473-4209

journal_volume

42

pub_type

杂志文章
  • Comparing calibration methods of electron beams using plane-parallel chambers with absorbed-dose to water based protocols.

    abstract::Recent absorbed-dose-based protocols allow for two methods of calibrating electron beams using plane-parallel chambers, one using the N(Co)D,w for a plane-parallel chamber, and the other relying on cross-calibration of the plane-parallel chamber in a high-energy electron beam against a cylindrical chamber which has an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1449876

    authors: Stewart KJ,Seuntjens JP

    更新日期:2002-03-01 00:00:00

  • SU-E-J-192: Static Breath-Hold MRI Based Measurement of Change in Pulmonary Function Following a Course of Radiation Therapy.

    abstract:PURPOSE:Radiation Therapy (RT) induced pulmonary function change may depend on the location, underlying function of that lung prior to radiations, radiation dose/fractionation and other factors. We propose to evaluate the radiation induced pulmonary function change using static breath-hold MRI scans with vascular infor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735033

    authors: Ding K,Cao K,Du K,Chen Q,Ennis D,Christensen G,Reinhardt J,Libby B,Benedict S,Sheng K

    更新日期:2012-06-01 00:00:00

  • Future of medical physics: Real-time MRI-guided proton therapy.

    abstract::With the recent clinical implementation of real-time MRI-guided x-ray beam therapy (MRXT), attention is turning to the concept of combining real-time MRI guidance with proton beam therapy; MRI-guided proton beam therapy (MRPT). MRI guidance for proton beam therapy is expected to offer a compelling improvement to the c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12371

    authors: Oborn BM,Dowdell S,Metcalfe PE,Crozier S,Mohan R,Keall PJ

    更新日期:2017-08-01 00:00:00

  • Potential of high-Z contrast agents in clinical contrast-enhanced computed tomography.

    abstract:PURPOSE:Currently, only iodine- and barium-based contrast media (CM) are used in clinical contrast-enhanced computed tomography (CE-CT). High-Z metals would produce a higher contrast at equal mass density for the x-ray spectra used in clinical CT. Using such materials might allow for significant dose reductions in CE-C...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3658738

    authors: Nowak T,Hupfer M,Brauweiler R,Eisa F,Kalender WA

    更新日期:2011-12-01 00:00:00

  • A real time dose monitoring and dose reconstruction tool for patient specific VMAT QA and delivery.

    abstract:PURPOSE:To develop a real time dose monitoring and dose reconstruction tool to identify and quantify sources of errors during patient specific volumetric modulated arc therapy (VMAT) delivery and quality assurance. METHODS:The authors develop a VMAT delivery monitor tool called linac data monitor that connects to the ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4764482

    authors: Tyagi N,Yang K,Gersten D,Yan D

    更新日期:2012-12-01 00:00:00

  • Sci-Fri PM: Planning-04: Dose escalation study using anatomy-based aperture IMRT and SPECT perfusion images for lung cancer.

    abstract::In the case of non-small cell lung cancer, doses typically prescribed (60-66 Gy) are not sufficient to ensure a satisfactory tumor control probability. Dose escalation needs to be realized, but dose to organs at risk (OARs) must be kept under widely accepted clinical thresholds. Also, lung functionality is not homogen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965976

    authors: St-Hilaire J,Lavoie C,Beaulieu F,Dagnault A,Morin F,Gingras L,Tremblay D,Beaulieu L

    更新日期:2008-07-01 00:00:00

  • SU-E-I-94: External Beam Radiation Cherenkov Emission in Tissue Used for Tissue Oxygen Sensing.

    abstract:PURPOSE:To show that Cherenkov emission is generated by external radiotherapy beam in tissue, and could serve as optical source to excite an oxygen sensitive phosphor, Oxyphor G4, within tissue. The intensity and lifetime of the phosphorescence was measured with a time-gated system and reveals the oxygenation levels in...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734811

    authors: Zhang R,Kanick S,Vinogradov S,Esipova T,Pogue B

    更新日期:2012-06-01 00:00:00

  • MO-A-217BCD-01: Internal Emitter Dose Estimation.

    abstract::Tissue absorbed dose (D) is a computed result for internal emitters. For fixed geometries, D is calculated by a matrix (S) multiplication of the integrated activity vector (Ã). The last quantity is usually measured by nuclear imaging of activity in various source organs and performing a temporal integration. Ã is the ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735750

    authors: Williams L

    更新日期:2012-06-01 00:00:00

  • Suitability of laser stimulated TLD arrays as patient dose monitors in high dose x-ray imaging.

    abstract::Skin entrance doses of patients undergoing interventional x-ray procedures are capable of causing skin damage and should be monitored routinely. Single TLD chips are not suitable because the location of maximum skin exposure cannot be predicted. Most photographic films are too sensitive at diagnostic x-ray energies fo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597973

    authors: Geise RA,Schueler BA,Lien W,Jones SC

    更新日期:1997-10-01 00:00:00

  • Constrained reconstruction: a superresolution, optimal signal-to-noise alternative to the Fourier transform in magnetic resonance imaging.

    abstract::Many problems in physics involve imaging objects with high spatial frequency content in a limited amount of time. The limitation of available experimental data leads to the infamous problem of diffraction limited data which manifests itself by causing ringing in the image. This ringing is due to the interference pheno...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596427

    authors: Haacke EM,Liang ZP,Izen SH

    更新日期:1989-05-01 00:00:00

  • 3D MTF estimation using sphere phantoms for cone-beam computed tomography systems.

    abstract:PURPOSE:For cone-beam computed tomography (CBCT) systems, we propose a sphere phantom based method to estimate the full three-dimensional (3D) modulation transfer function (MTF). METHODS:The FDK reconstruction of CBCT system in a local region was modeled by a triple convolution operator. Afterward, we calculated the d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14147

    authors: Lee C,Song HD,Baek J

    更新日期:2020-07-01 00:00:00

  • An empirical model for independent dose verification of the Gamma Knife treatment planning.

    abstract::A formalism for an independent dose verification of the Gamma Knife treatment planning is developed. It is based on the approximation that isodose distribution for a single shot is in the shape of an ellipsoid in three-dimensional space. The dose profiles for a phantom along each of the three major axes are fitted to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1501139

    authors: Phaisangittisakul N,Ma L

    更新日期:2002-09-01 00:00:00

  • Determination of the reference air kerma rate for 192Ir brachytherapy sources and the related uncertainty.

    abstract::Different methods exist to determine the air kerma calibration factor of an ionization chamber for the spectrum of a 192Ir high-dose-rate (HDR) or pulsed-dose-rate (PDR) source. An analysis of two methods to obtain such a calibration factor was performed: (i) the method recommended by [Goetsch et al., Med. Phys. 18, 4...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1791352

    authors: van Dijk E,Kolkman-Deurloo IK,Damen PM

    更新日期:2004-10-01 00:00:00

  • ARPM-net: A novel CNN-based adversarial method with Markov random field enhancement for prostate and organs at risk segmentation in pelvic CT images.

    abstract:PURPOSE:The research is to develop a novel CNN-based adversarial deep learning method to improve and expedite the multi-organ semantic segmentation of CT images and to generate accurate contours on pelvic CT images. METHODS:Planning CT and structure datasets for 120 patients with intact prostate cancer were retrospect...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14580

    authors: Zhang Z,Zhao T,Gay H,Zhang W,Sun B

    更新日期:2020-11-05 00:00:00

  • Superiorization: an optimization heuristic for medical physics.

    abstract:PURPOSE:To describe and mathematically validate the superiorization methodology, which is a recently developed heuristic approach to optimization, and to discuss its applicability to medical physics problem formulations that specify the desired solution (of physically given or otherwise obtained constraints) by an opti...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4745566

    authors: Herman GT,Garduno E,Davidi R,Censor Y

    更新日期:2012-09-01 00:00:00

  • Evaluation of delivered monitor unit accuracy of gated step-and-shoot IMRT using a two-dimensional detector array.

    abstract:PURPOSE:To overcome the problem of organ motion in intensity-modulated radiation therapy (IMRT), gated IMRT is often used for the treatment of lung cancer. In this study, the authors investigated the accuracy of the delivered monitor units (MUs) from each segment during gated IMRT using a two-dimensional detector array...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3310806

    authors: Cheong KH,Kang SK,Lee M,Kim SS,Park S,Hwang TJ,Kim KJ,Oh DH,Bae H,Suh TS

    更新日期:2010-03-01 00:00:00

  • A framework for defining FLASH dose rate for pencil beam scanning.

    abstract:PURPOSE:To develop a method of (a) calculating the dose rate of voxels within a proton field delivered using pencil beam scanning (PBS), and (b) reporting a representative dose rate for the PBS treatment field that enables correspondence between multiple treatment modalities. This method takes into account the unique s...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14456

    authors: Folkerts MM,Abel E,Busold S,Perez JR,Krishnamurthi V,Ling CC

    更新日期:2020-12-01 00:00:00

  • Comparison of x ray computed tomography number to proton relative linear stopping power conversion functions using a standard phantom.

    abstract:PURPOSE:Adequate evaluation of the results from multi-institutional trials involving light ion beam treatments requires consideration of the planning margins applied to both targets and organs at risk. A major uncertainty that affects the size of these margins is the conversion of x ray computed tomography numbers (XCT...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4870956

    authors: Moyers MF

    更新日期:2014-06-01 00:00:00

  • VMAT and IMRT plan-specific correction factors for linac-based ionization chamber dosimetry.

    abstract:PURPOSE:The determination of absorbed dose to water from external beam radiotherapy using radiation detectors is currently rooted in calibration protocols that do not account for modulations encountered in patient-specific deliveries. Detector response in composite clinical fields has not been extensively studied due t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13293

    authors: Desai VK,Labby ZE,Hyun MA,DeWerd LA,Culberson WS

    更新日期:2019-02-01 00:00:00

  • The effects of target size and tissue density on the minimum margin required for random errors.

    abstract::The minimum margins required to compensate for random geometric uncertainties in the delivery of radiotherapy treatment were determined for a spherical Clinical Target Volume, using an analytic model for the cumulative dose. Margins were calculated such that the minimum dose in the target would be no less than 95% of ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1809991

    authors: Witte MG,van der Geer J,Schneider C,Lebesque JV,van Herk M

    更新日期:2004-11-01 00:00:00

  • Shimming with permanent magnets for the x-ray detector in a hybrid x-ray/ MR system.

    abstract::In this x-ray/MR hybrid system an x-ray flat panel detector is placed under the patient cradle, close to the MR volume of interest (VOI), where the magnetic field strength is approximately 0.5 T. Immersed in this strong field, several electronic components inside the detector become magnetized and create an additional...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2963994

    authors: Wen Z,Fahrig R,Williams ST,Pelc NJ

    更新日期:2008-09-01 00:00:00

  • Introduction of heat map to fidelity assessment of compressed CT images.

    abstract:PURPOSE:This study aimed to introduce heat map, a graphical data presentation method widely used in gene expression experiments, to the presentation and interpretation of image fidelity assessment data of compressed computed tomography (CT) images. METHODS:The authors used actual assessment data that consisted of five...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3611046

    authors: Lee H,Kim B,Kim KJ,Seo J,Park S,Shin YG,Lee KH

    更新日期:2011-08-01 00:00:00

  • Performance of a high-sensitivity dedicated cardiac SPECT scanner for striatal uptake quantification in the brain based on analysis of projection data.

    abstract:PURPOSE:The authors have previously reported the advantages of high-sensitivity single-photon emission computed tomography (SPECT) systems for imaging structures located deep inside the brain. DaTscan (Isoflupane I-123) is a dopamine transporter (DaT) imaging agent that has shown potential for early detection of Parkin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4794488

    authors: Park MA,Moore SC,Müller SP,McQuaid SJ,Kijewski MF

    更新日期:2013-04-01 00:00:00

  • Computer-aided detection of mammographic microcalcifications: pattern recognition with an artificial neural network.

    abstract::We are developing a computer program for automated detection of clustered microcalcifications on mammograms. In this study, we investigated the effectiveness of a signal classifier based on a convolution neural network (CNN) approach for improvement of the accuracy of the detection program. Fifty-two mammograms with c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597428

    authors: Chan HP,Lo SC,Sahiner B,Lam KL,Helvie MA

    更新日期:1995-10-01 00:00:00

  • Vision 20/20: Molecular-guided surgical oncology based upon tumor metabolism or immunologic phenotype: Technological pathways for point of care imaging and intervention.

    abstract::Surgical guidance with fluorescence has been demonstrated in individual clinical trials for decades, but the scientific and commercial conditions exist today for a dramatic increase in clinical value. In the past decade, increased use of indocyanine green based visualization of vascular flow, biliary function, and tis...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4951732

    authors: Pogue BW,Paulsen KD,Samkoe KS,Elliott JT,Hasan T,Strong TV,Draney DR,Feldwisch J

    更新日期:2016-06-01 00:00:00

  • Tolerance limits and methodologies for IMRT measurement-based verification QA: Recommendations of AAPM Task Group No. 218.

    abstract:PURPOSE:Patient-specific IMRT QA measurements are important components of processes designed to identify discrepancies between calculated and delivered radiation doses. Discrepancy tolerance limits are neither well defined nor consistently applied across centers. The AAPM TG-218 report provides a comprehensive review a...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.12810

    authors: Miften M,Olch A,Mihailidis D,Moran J,Pawlicki T,Molineu A,Li H,Wijesooriya K,Shi J,Xia P,Papanikolaou N,Low DA

    更新日期:2018-04-01 00:00:00

  • Feasibility of a simple method of hybrid collimation for megavoltage grid therapy.

    abstract:PURPOSE:Megavoltage grid therapy is currently delivered with step-and-shoot multisegment techniques or using a high attenuation block with divergent holes. However, the commercial availability of grid blocks is limited, their construction is difficult, and step-and-shoot techniques require longer treatment times and ar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4801902

    authors: Almendral P,Mancha PJ,Roberto D

    更新日期:2013-05-01 00:00:00

  • Fast dose optimization for rotating shield brachytherapy.

    abstract:PURPOSE:To provide a fast computational method, based on the proximal graph solver (POGS) - A convex optimization solver using the alternating direction method of multipliers (ADMM), for calculating an optimal treatment plan in rotating shield brachytherapy (RSBT). RSBT treatment planning has more degrees of freedom th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12486

    authors: Cho M,Wu X,Dadkhah H,Yi J,Flynn RT,Kim Y,Xu W

    更新日期:2017-10-01 00:00:00

  • Small SRS photon field profile dosimetry performed using a PinPoint air ion chamber, a diamond detector, a novel silicon-diode array (DOSI), and polymer gel dosimetry. Analysis and intercomparison.

    abstract::Small photon fields are increasingly used in modern radiotherapy and especially in IMRT and SRS/SRT treatments. The uncertainties related to small field profile measurements can introduce significant systematic errors to the overall treatment process. These measurements are challenging mainly due to the absence of cha...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2977829

    authors: Pappas E,Maris TG,Zacharopoulou F,Papadakis A,Manolopoulos S,Green S,Wojnecki C

    更新日期:2008-10-01 00:00:00

  • Sample size requirements for estimating effective dose from computed tomography using solid-state metal-oxide-semiconductor field-effect transistor dosimetry.

    abstract:PURPOSE:Effective dose (ED) is a widely used metric for comparing ionizing radiation burden between different imaging modalities, scanners, and scan protocols. In computed tomography (CT), ED can be estimated by performing scans on an anthropomorphic phantom in which metal-oxide-semiconductor field-effect transistor (M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4868693

    authors: Trattner S,Cheng B,Pieniazek RL,Hoffmann U,Douglas PS,Einstein AJ

    更新日期:2014-04-01 00:00:00