Abstract:
:Recent absorbed-dose-based protocols allow for two methods of calibrating electron beams using plane-parallel chambers, one using the N(Co)D,w for a plane-parallel chamber, and the other relying on cross-calibration of the plane-parallel chamber in a high-energy electron beam against a cylindrical chamber which has an N(Co)D,w factor. The second method is recommended as it avoids problems associated with the Pwall correction factors at 60Co for plane-parallel chambers which are used in the determination of the beam quality conversion factors. In this article we investigate the consistency of these two methods for the PTW Roos, Scanditronics NACP02, and PTW Markus chambers. We processed our data using both the AAPM TG-51 and the IAEA TRS-398 protocols. Wall correction factors in 60Co beams and absorbed-dose beam quality conversion factors for 20 MeV electrons were derived for these chambers by cross-calibration against a cylindrical ionization chamber. Systematic differences of up to 1.6% were found between our values of Pwall and those from the Monte Carlo calculations underlying AAPM TG-51, and up to 0.6% when comparing with the IAEA TRS-398 protocol. The differences in Pwall translate directly into differences in the beam quality conversion factors in the respective protocols. The relatively large spread in the experimental data of Pwall, and consequently the absorbed-dose beam quality conversion factor, confirms the importance of the cross-calibration technique when using plane-parallel chambers for calibrating clinical electron beams. We confirmed that for well-guarded plane-parallel chambers, the fluence perturbation correction factor at d(max) is not significantly different from the value at d(ref). For the PTW Markus chamber the variation in the latter factor is consistent with published fits relating it to average energy at depth.
journal_name
Med Physjournal_title
Medical physicsauthors
Stewart KJ,Seuntjens JPdoi
10.1118/1.1449876subject
Has Abstractpub_date
2002-03-01 00:00:00pages
284-9issue
3eissn
0094-2405issn
2473-4209journal_volume
29pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:This study (1) examines a variety of real-world cases where systematic errors were not detected by widely accepted methods for IMRT/VMAT dosimetric accuracy evaluation, and (2) drills-down to identify failure modes and their corresponding means for detection, diagnosis, and mitigation. The primary goal of detai...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4826166
更新日期:2013-11-01 00:00:00
abstract:PURPOSE:An electrically floating radio frequency (RF) shielded PET insert with individual PET detectors shielded by separate Faraday cages enables the MRI built-in body RF coil to be used at least as an RF transmitter, in which the RF field penetrates the imaging region inside the PET ring through the narrow gaps betwe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13132
更新日期:2018-10-01 00:00:00
abstract:PURPOSE:The treatment of moving targets with scanned proton beams is challenging. For motion mitigation, an Active Breathing Coordinator (ABC) can be used to assist breath-holding. The delivery of pencil beam scanning fields often exceeds feasible breath-hold durations, requiring high breath-hold reproducibility. We ev...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13195
更新日期:2018-12-01 00:00:00
abstract::We employed an elastic reservoir filled with tissue-equivalent fluid as an x-ray beam filter for exposure equalization. The filter is designed to be placed between the upper compression plate and the breast. During compression, it will conform to the shape of the peripheral region of the breast and fill the space betw...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596502
更新日期:1990-03-01 00:00:00
abstract:PURPOSE:To present EBT2 film verification of treatment planning with the eXtend System, a relocatable frame system for multiple-fraction or serial multiple-session radiosurgery. METHODS:A human head shaped phantom simulated the verification process for fractionated Gamma Knife (GK) treatment. Phantom preparation for e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735487
更新日期:2012-06-01 00:00:00
abstract::Respiration can cause tumors in the thorax or abdomen to move by as much as 3 cm; this movement can adversely affect the planning and delivery of radiation treatment. Several techniques have been used to compensate for respiratory motion, but all have shortcomings. Manufacturers of computed tomography (CT) equipment h...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2044427
更新日期:2006-01-01 00:00:00
abstract:PURPOSE:The accuracy of a six degree of freedom (6DoF) couch was evaluated using a novel method. METHODS:Cone beam CT (CBCT) images of a 3D phantom (IsoCal) were acquired with different, known combinations of couch pitch and roll angles. Pitch and roll angles between the maximum allowable values of 357 and 3 degrees w...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12342
更新日期:2017-08-01 00:00:00
abstract:PURPOSE:The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD). METHODS:Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and exp...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4813906
更新日期:2013-08-01 00:00:00
abstract::Image intensifier-television-video digitizer (IITVD) systems are commonly used for digital planar image acquisition in radiology. However, the well-known distortions inherent in these systems limit their utility in research and in some clinical applications where quantitatively correct images are required. Software co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596718
更新日期:1991-03-01 00:00:00
abstract:PURPOSE:Range uncertainties limit the potential of charged particle therapy. In vivo and online range verification techniques could increase the confidence in the dose delivery distribution and lead to more conformal treatments. Prompt gamma imaging and prompt gamma spectroscopy (PGS) have been demonstrated for such a ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12795
更新日期:2018-04-01 00:00:00
abstract:PURPOSE:Mega-voltage cone-beam CT (MVCBCT) imaging can be used to monitor changes in neck flexion and calculate the true spinal cord dose during radiotherapy. To sum the dose over multiple fractions and compare with the planned dose requires deformable image registration. This study investigates the accuracy of deforma...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734919
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To determine the diagnostic efficacy of optical coherence tomography (OCT) to identify cervical intraepithelial neoplasia (CIN) grade 2 or higher by computer-aided diagnosis (CADx). METHODS:OCT has been investigated as a screening/diagnostic tool in the management of preinvasive and early invasive cancers of t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3523098
更新日期:2011-01-01 00:00:00
abstract::Effects of changes in the physics of EGSnrc compared to EGS4/PRESTA on energy deposition kernels for monoenergetic photons and on dose point kernels for beta sources in water are investigated. In the diagnostic energy range, Compton binding corrections were found to increase the primary energy fraction up to 4.5% at 3...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1861412
更新日期:2005-03-01 00:00:00
abstract::Dose calculations for treatment planning of photon beam radiotherapy require a model of the beam to drive the dose calculation models. The beam shaping process involves scattering and filtering that yield radiation components which vary with collimator settings. The necessity to model these components has motivated th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1898485
更新日期:2005-06-01 00:00:00
abstract:PURPOSE:TransitQA is an innovative method for Tomotherapy transit dosimetry using the on-board detector (OBD). Our previously published model for Tomotherapy treatment plan verification (AirQA) has been enhanced to take into account patient and couch transmission. AirQA estimates the OBD signal during irradiation with ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12672
更新日期:2018-01-01 00:00:00
abstract:PURPOSE:In recent years, laser-based acceleration of charged particles has rapidly progressed and medical applications, e.g., in radiotherapy, might become feasible in the coming decade. Requirements are monoenergetic particle beams with long-term stable and reproducible properties as well as sufficient particle intens...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3301598
更新日期:2010-04-01 00:00:00
abstract::The physical imaging performance of ST-V, ST-VA, and ST-VN computed radiography image plates, read with a Philips AC3 acquisition system, was investigated at 70 kVp with 0.5 mm of copper beam filtration for four different entrance air kerma values: 0.5, 2.6, 26, and 260 micro Gy. Measurements included characteristic r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598412
更新日期:1998-11-01 00:00:00
abstract::In this paper a novel technique is proposed and validated for radiosurgery treatment planning of arteriovenous malformations (AVMs). The technique was developed for frameless radiosurgery by means of the CyberKnife, a nonisocentric, linac-based system which allows highly conformed isodose surfaces to be obtained, whil...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1751252
更新日期:2004-06-01 00:00:00
abstract:PURPOSE:Theoretical models of the detective quantum efficiency (DQE) of x-ray detectors are an important step in new detector development by providing an understanding of performance limitations and benchmarks. Previous cascaded-systems analysis (CSA) models accounted for photoelectric interactions only. This paper des...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4794495
更新日期:2013-04-01 00:00:00
abstract::The Gafchromic EBT was recently introduced in film dosimetry for external beam therapy (EBT). The high spatial resolution, weak energy dependence, and near-tissue equivalence of EBT films make them suitable for measurement of dose distributions in radiotherapy, especially intensity-modulated radiation therapy (IMRT). ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2362876
更新日期:2006-11-01 00:00:00
abstract::A method to determine the bone mineral density of the calcaneum has been reported earlier by our laboratory. In this method, the calcaneum is irradiated by a 60-keV photon beam from 241Am source and both the coherent and Compton scattered photons are detected by a high-purity Ge detector. The bone mineral density is d...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595669
更新日期:1985-07-01 00:00:00
abstract:PURPOSE:The electronic portal imaging device (EPID) is a system for checking the patient setup; as a result of its integration with the linear accelerator and software customized for dosimetry, it is increasingly used for verification of the delivery of fixed-field intensity-modulated radiation therapy (IMRT). In order...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3271107
更新日期:2010-01-01 00:00:00
abstract:PURPOSE:Compton camera imaging (CCI) systems are currently under investigation for radiotherapy dose reconstruction and verification. The ability of such a system to provide real-time images during dose delivery will be limited by the computational speed of the image reconstruction algorithm. In this work, the authors ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3519873
更新日期:2011-01-01 00:00:00
abstract:PURPOSE:To compare and evaluate intensity-based registration methods for computation of serial x-ray mammogram correspondence. METHODS:X-ray mammograms were simulated from MRIs of 20 women using finite element methods for modeling breast compressions and employing a MRI/x-ray appearance change model. The parameter con...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3457470
更新日期:2010-09-01 00:00:00
abstract::A method for optimizing MR imaging pulse sequence parameters in a statistical framework is presented. Parameters are defined to be optimal when the resulting scalar images yield optimal image segmentations using Bayesian pixel classification. Thus, Bayes risk is used as the objective function to minimize. Approximatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597425
更新日期:1995-10-01 00:00:00
abstract:PURPOSE:The purpose of this study was to provide updated radiation dose from diagnostic exams performed for pregnant patients suspected of pulmonary embolism (PE) using the recently developed BREP phantoms of pregnant woman and the fetus. Also to challenge the validity of current recommendations suggest that ventilatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12558
更新日期:2017-11-01 00:00:00
abstract:PURPOSE:In C-arm computed tomography (CT), the field of view (FOV) is often not sufficient to acquire certain anatomical structures, e.g., a full hip or thorax. Proposed methods to extend the FOV use a fixed detector displacement and a 360° scan range to double the radius of the FOV. These trajectories are designed for...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4915542
更新日期:2015-05-01 00:00:00
abstract:PURPOSE:The spot characteristics for proton pencil beam scanning (PBS) were measured and analyzed over a 16 month period, which included one major site configuration update and six cyclotron interventions. The results provide a reference to establish the quality assurance (QA) frequency and tolerance for proton pencil ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4939663
更新日期:2016-02-01 00:00:00
abstract:PURPOSE:Radiochromic film provides dose measurement at high spatial resolution, but often is not preferred for routine evaluation of patient-specific intensity modulated radiation therapy (IMRT) plans owing to ease-of-use factors. The authors have established an efficient protocol that combines calibration and measurem...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4754797
更新日期:2012-10-01 00:00:00
abstract::Stereo x-ray radiography attracts increasing attention in major clinical applications. The purpose of this paper is to analyze the 3D localization error for breast biopsy procedures and provide guidelines for improving its accuracy. Our prototype is a CCD based digital stereo x-ray imaging system. The mathematical mod...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598953
更新日期:2000-05-01 00:00:00