Abstract:
PURPOSE:The electronic portal imaging device (EPID) is a system for checking the patient setup; as a result of its integration with the linear accelerator and software customized for dosimetry, it is increasingly used for verification of the delivery of fixed-field intensity-modulated radiation therapy (IMRT). In order to extend such an approach to intensity-modulated arc therapy (IMAT), the combined use of an EPID system and a portal dose image prediction (PDIP) tool has been investigated. METHODS:The dosimetric behavior of an EPID system, mechanically reinforced to maintain its positional stability during the accelerator gantry rotation, has been studied to assess its ability to measure portal dose distributions for IMAT treatment beams. In addition, the PDIP tool of a commercial treatment planning system, commonly used for static IMRT dosimetry, has been validated for simulating the PDIs of IMAT treatment fields. The method has been applied to the delivery verification of 23 treatment fields that were measured in their dual mode of IMRT and IMAT modalities. RESULTS:The EPID system has proved to be appropriate for measuring the PDIs of IMAT fields; additionally the PDIP tool was able to simulate these accurately. The results are quite similar to those obtained for static IMRT treatment verification, although it was necessary to investigate the dependence of the EPID signal and of the accelerator monitor chamber response on variable dose rate. CONCLUSIONS:Our initial tests indicate that the EPID system, together with the PDIP tool, is a suitable device for the verification of IMAT plan delivery; however, additional tests are necessary to confirm these results.
journal_name
Med Physjournal_title
Medical physicsauthors
Iori M,Cagni E,Paiusco M,Munro P,Nahum AEdoi
10.1118/1.3271107subject
Has Abstractpub_date
2010-01-01 00:00:00pages
377-90issue
1eissn
0094-2405issn
2473-4209journal_volume
37pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:This work describes the performance characterization of a cone-beam CT-guided radiosurgery device, the Gamma Knife® Icon™. METHODS:The performance tests have been categorized into: (a) image quality and mechanical integrity; (b) image coregistration fidelity; (c) adaptive treatment delivery quality; (d) high d...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13073
更新日期:2018-06-29 00:00:00
abstract:PURPOSE:Micro-CT is widely used for small animal imaging in preclinical studies of cardiopulmonary disease, but further development is needed to improve spatial resolution, temporal resolution, and material contrast. We present a technique for visualizing the changing distribution of iodine in the cardiac cycle with du...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736809
更新日期:2012-08-01 00:00:00
abstract::The mixed-field dosimetry for 252Cf Applicator Tube (AT) type medical sources available from Oak Ridge National Laboratory (ORNL) has been characterized using ionization chambers, a GM counter, and Monte Carlo methods. Unlike the AAPM Task Group No. 43 (TG-43), specification of dose to muscle instead of water is recom...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598646
更新日期:1999-08-01 00:00:00
abstract:PURPOSE:There is interest in developing linac-MR systems for MRI-guided radiation therapy. To date, the designs for such linac-MR devices have been restricted to a transverse geometry where the static magnetic field is oriented perpendicular to the direction of the incident photon beam. This work extends possibilities ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3475942
更新日期:2010-09-01 00:00:00
abstract::Spectrally resolved bioluminescence optical tomography is an approach to recover images of, for example, Luciferase activity within a volume using multiwavelength emission data from internal bioluminescence sources. The underlying problem of uniqueness associated with nonspectrally resolved intensity-based bioluminesc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2982138
更新日期:2008-11-01 00:00:00
abstract:PURPOSE:Within the European project ALLEGRO (grant agreement no. 231965), the out-of-field dose delivered to a patient when treated with different radiotherapy modalities was investigated. The study compared the dose distribution during photon and particle irradiations both in a water and an anthropomorphic phantom to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735792
更新日期:2012-06-01 00:00:00
abstract::The purpose of this paper is to examine the thermal dose distribution, to configure the optimal absorbed power deposition, and to design an appropriate heating strategy for ultrasound thermal therapy. This work employs simulation programs, which are based on the transient bio-heat transfer equation and an ideal absorb...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1406516
更新日期:2001-10-01 00:00:00
abstract::Amorphous selenium (a-Se) based real-time flat-panel imagers (FPIs) are finding their way into the digital radiology department because they offer the practical advantages of digital x-ray imaging combined with an image quality that equals or outperforms that of conventional systems. The temporal imaging characteristi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2042248
更新日期:2005-10-01 00:00:00
abstract:PURPOSE:The authors combine the registration of 2D beam's eye view (BEV) images and 3D planning computed tomography (CT) images, with relative, markerless tumor tracking to provide automatic absolute tracking of physician defined volumes such as the gross tumor volume (GTV). METHODS:During treatment of lung SBRT cases...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4900603
更新日期:2014-12-01 00:00:00
abstract:PURPOSE:Accurately predicting outcome (i.e., overall survival (OS) time) for higher grade glioma (HGG) has great clinical value and would provide optimized guidelines for treatment planning. Radiomics focuses on revealing underlying pathophysiological information in biomedical images for disease analysis and demonstrat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13288
更新日期:2019-01-01 00:00:00
abstract::A method is described for obtaining S values between a tumor and its host organ for use with the MIRD formalism. It applies the point-source specific absorbed fractions for an infinite water medium, tabulated by Berger, to a rectangular solid of arbitrary dimensions which contains a rectangular tumor of arbitrary dime...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596732
更新日期:1991-05-01 00:00:00
abstract:PURPOSE:To compare optimization characteristics, plan quality, and treatment delivery efficiency between total marrow irradiation (TMI) plans using the new TomoTherapy graphic processing unit (GPU) based dose engine and CPU/cluster based dose engine. METHODS:Five TMI plans created on an anthropomorphic phantom were op...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4810936
更新日期:2013-07-01 00:00:00
abstract::Intensity modulated radiotherapy (IMRT) requires extensive knowledge of multileaf collimator (MLC) leaf positioning accuracy, precision, and long-term reproducibility. We have developed a technique to efficiently measure the absolute position of each MLC leaf, over the range of leaf positions utilized in IMRT, based o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1564091
更新日期:2003-05-01 00:00:00
abstract:PURPOSE:This work concerns computed tomography (CT)-based cardiac functional analysis (CFA) with a reduced radiation dose. As CT-CFA requires images over the entire heartbeat, the scans are often performed at 10-20% of the tube current settings that are typically used for coronary CT angiography. A large image noise th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12425
更新日期:2017-09-01 00:00:00
abstract:PURPOSE:Lung cancer is a major cause of cancer deaths, and the 5-year survival rate of stage IV lung cancer patients is only 2%. However, the 5-year survival rate of stage I lung cancer patients significantly increases to 50%. As such, spiral computed tomography (CT) scans are necessary to diagnose high-risk lung cance...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12331
更新日期:2017-08-01 00:00:00
abstract::Accurately assessing the quality of prostate brachytherapy intraoperatively would be valuable for improved clinical outcome by ensuring the delivery of a prescribed tumoricidal radiation dose to the entire prostate gland. One necessary step towards this goal is the robust and rapid localization of implanted seeds. Sev...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1624755
更新日期:2003-12-01 00:00:00
abstract::To achieve increased image acquisition speed or better image quality, several read-out methods for a matrix ionization chamber system have been investigated. In this device, which is applied for portal imaging in radiation therapy, 256 x 256 small liquid-filled ionization chambers are scanned by switching the polarizi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596829
更新日期:1992-03-01 00:00:00
abstract:PURPOSE:Lower radiation tolerance of the whole liver hinders dose escalations of stereotactic body radiation therapy (SBRT) in hepatocellular carcinoma (HCC) treatment. This study was conducted to define the exact doses that result in radiation-induced liver disease (RILD) as well as to determine dose constraints for t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4953831
更新日期:2016-07-01 00:00:00
abstract::Quantitative evaluation of cardiac image data obtained using multidetector row computed tomography (CT) is compromised by partial scan reconstructions, which improve the temporal resolution but significantly increase image-to-image CT number variations for a fixed region of interest compared to full reconstruction ima...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2805476
更新日期:2007-12-01 00:00:00
abstract:PURPOSE:Transcranial focused ultrasound is an emerging therapeutic modality that can be used to perform noninvasive neurosurgical procedures. The current clinical transcranial phased array operates at 650 kHz, however the development of a higher frequency array would enable more precision, while reducing the risk of st...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4829510
更新日期:2013-12-01 00:00:00
abstract::Monte Carlo (MC) techniques can be used to build a simulation model of an electron accelerator to calculate output factors for electron fields. This can be useful during commissioning of electron beams from a linac and in clinical practice where irregular fields are also encountered. The Monte Carlo code BEAM/EGS4 was...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1373402
更新日期:2001-06-01 00:00:00
abstract:PURPOSE:To develop a deformable mapping technique to match corresponding lesions between digital breast tomosynthesis (DBT) and automated breast ultrasound (ABUS) images. METHODS:External fiducial markers were attached to the surface of two CIRS multi-modality compressible breast phantoms (A and B) containing multiple...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13113
更新日期:2018-10-01 00:00:00
abstract::Spectra, yields, average energies, and kerma rates in tissue of neutrons from 21-MeV deuteron bombardment of deuterium gas targets have been calculated for target thicknesses of 1, 3.5, and 5 MeV. A high pressure gas cell was constructed and was filled with 33 atm of D2 gas (equivalent to an energy loss of 3.5 MeV for...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594561
更新日期:1979-05-01 00:00:00
abstract::In the case of non-small cell lung cancer, doses typically prescribed (60-66 Gy) are not sufficient to ensure a satisfactory tumor control probability. Dose escalation needs to be realized, but dose to organs at risk (OARs) must be kept under widely accepted clinical thresholds. Also, lung functionality is not homogen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965976
更新日期:2008-07-01 00:00:00
abstract:PURPOSE:To develop a computer-driven and thus less user-dependent method, allowing for a simple and straightforward generation of a Monte Carlo (MC) beam model of a scanned proton and carbon ion beam delivery system. METHODS:In a first step, experimental measurements were performed for proton and carbon ion energies i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14647
更新日期:2020-12-07 00:00:00
abstract::The head-scatter factors H were examined for four different linear accelerators and were found to be similar at field sizes larger than 3 x 3 cm2. Sharply reduced values for small collimator openings were observed for all the accelerators. It is concluded that the head-scatter (or collimator-scatter) factor has two ma...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597256
更新日期:1994-01-01 00:00:00
abstract::In this report we describe an improvement upon the design by Stanton and Lightfoot for a simple photographic null method to determine the kVp of a diagnostic region x-ray source. The new version has two primary advantages over the Ardran and Crooks design in that it is both simpler and less expensive to produce. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595716
更新日期:1985-03-01 00:00:00
abstract::In this study, we present an algorithm for three-dimensional (3-D) dose reconstruction using portal images obtained with an electronic portal imaging device (EPID). For this purpose an algorithm for 2-D dose reconstruction, which was previously developed in our institution, was adapted. The external contour of the pat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1589496
更新日期:2003-09-01 00:00:00
abstract:PURPOSE:Deformable registration generally relies on the assumption that the sought spatial transformation is smooth. Yet, breathing motion involves sliding of the lung with respect to the chest wall, causing a discontinuity in the motion field, and the smoothness assumption can lead to poor matching accuracy. In respon...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3679009
更新日期:2012-02-01 00:00:00
abstract:PURPOSE:Mega-voltage cone-beam CT (MVCBCT) imaging can be used to monitor changes in neck flexion and calculate the true spinal cord dose during radiotherapy. To sum the dose over multiple fractions and compare with the planned dose requires deformable image registration. This study investigates the accuracy of deforma...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734919
更新日期:2012-06-01 00:00:00