Abstract:
:A method is described for obtaining S values between a tumor and its host organ for use with the MIRD formalism. It applies the point-source specific absorbed fractions for an infinite water medium, tabulated by Berger, to a rectangular solid of arbitrary dimensions which contains a rectangular tumor of arbitrary dimensions. Contributions from pairs of source and target volume elements are summed for the S values between the tumor and itself, between the remaining healthy host organ and itself, and between the tumor and the remaining healthy host organ, with the reciprocity theorem assumed for the last. This method labeled MTUMOR, is interfaced with the widely used MIRDOSE program which incorporates the MIRD formalism. An example is calculated.
journal_name
Med Physjournal_title
Medical physicsauthors
Stinchcomb TG,Durham JS,Fisher DRdoi
10.1118/1.596732subject
Has Abstractpub_date
1991-05-01 00:00:00pages
555-8issue
3eissn
0094-2405issn
2473-4209journal_volume
18pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:To evaluate the availability and performance of pencil beam algorithm for fast neutrons radiotherapy dose calculations and to achieve improvements in universality, speed and inhomogeneities corrections. METHODS:Pencil beam (PB) method uses integration of dose kernel cross field size to estimate dose distributi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735630
更新日期:2012-06-01 00:00:00
abstract::Intensity modulated radiotherapy (IMRT) requires extensive knowledge of multileaf collimator (MLC) leaf positioning accuracy, precision, and long-term reproducibility. We have developed a technique to efficiently measure the absolute position of each MLC leaf, over the range of leaf positions utilized in IMRT, based o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1564091
更新日期:2003-05-01 00:00:00
abstract:PURPOSE:The need for an accurate lesion segmentation tool in 18FDG PET is a prerequisite for the estimation of lesion response to therapy, for radionuclide dosimetry, and for the application of 18FDG PET to radiotherapy planning. In this work, the authors have developed an iterative method based on a mathematical fit d...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3222732
更新日期:2009-10-01 00:00:00
abstract::A comparison of two methods of scatter compensation in single photon emission computed tomography (SPECT) imaging is made on the basis of improvements in quantification. The methods, scatter-window subtraction and constrained deconvolution of an average point source response function (PSRF), are described; the theoret...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596453
更新日期:1990-11-01 00:00:00
abstract:PURPOSE:To commission and benchmark a vendor-supplied (Varian Medical Systems) Monte Carlo phase-space data for the 6 MV flattening filter free (FFF) energy mode on a TrueBeam linear accelerator for the purpose of quality assurance of clinical volumetric modulated arc therapy (VMAT) treatment plans. A method for render...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4773883
更新日期:2013-02-01 00:00:00
abstract::Tissue absorbed dose (D) is a computed result for internal emitters. For fixed geometries, D is calculated by a matrix (S) multiplication of the integrated activity vector (Ã). The last quantity is usually measured by nuclear imaging of activity in various source organs and performing a temporal integration. Ã is the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735750
更新日期:2012-06-01 00:00:00
abstract::The purpose of this work is to calculate the dose perturbations due to the presence of iodine contrast media in catheter-based intravascular brachytherapy (IVBT). The EGSnrc Monte Carlo system was used to perform the calculation for the two most commonly used beta and gamma sources (90Sr and 192Ir as well as for a var...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1367279
更新日期:2001-05-01 00:00:00
abstract::A theoretical analysis of the x-ray phase contrast imaging and its validation via synchrotron radiation imaging is here presented. Two different mathematical models have been followed: the simpler ray-optical approach and the more rigorous Fresnel-Kirchoff diffraction theory. Subsequently, the conditions upon which th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2126207
更新日期:2005-12-01 00:00:00
abstract::The design and construction of a Styrofoam cutter used in the fabrication of custom shielding blocks is described. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594206
更新日期:1975-11-01 00:00:00
abstract::A commercial optical system developed by Solid Photography, Inc., has been used to generate precise paraffin--polyethylene tissue compensators. A program with the objective of constructing a medical facility has been undertaken to access patient topology for treatment planning, tissue-compensator fabrication, and pati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594447
更新日期:1978-11-01 00:00:00
abstract::Deformable image registration is an important tool for image-guided radiotherapy. Physics-model-based deformable image registration using finite element analysis is one of the methods currently being investigated. The calculation accuracy of finite element analysis is dependent on given boundary conditions, which are ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1774131
更新日期:2004-09-01 00:00:00
abstract:PURPOSE:Several treatment response metrics, such as RECIST and PERCIST, have been established for assessing individual solid tumors. However, metastatic prostate cancer poses a unique challenge to these metrics because bone lesions are often numerous and non-measureable. This study investigated the impact of using diff...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735035
更新日期:2012-06-01 00:00:00
abstract::This study compared air exposures during conventional dental and maxillofacial radiography and similar views using free-focus radiography with conventional image receptors. The results show that periapical type surveys on nonscreen film placed extraorally or in the buccal fold may be carried out with an exposure to th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594690
更新日期:1980-07-01 00:00:00
abstract:PURPOSE:To evaluate two deformable image registration (DIR) algorithms for the purpose of contour mapping to support image guided adaptive radiotherapy (IGART) with 4D cone beam CT (4DCBCT). METHODS:Eleven locally advanced non-small cell lung cancer (NSCLC) patients underwent one planning 4D fan- beam CT (4DFBCT) and ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735821
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:This study aimed to introduce heat map, a graphical data presentation method widely used in gene expression experiments, to the presentation and interpretation of image fidelity assessment data of compressed computed tomography (CT) images. METHODS:The authors used actual assessment data that consisted of five...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3611046
更新日期:2011-08-01 00:00:00
abstract:PURPOSE:The previously described 2D standardized vessel-wall-plus-plaque thickness (VWT) maps constructed from 3D ultrasound vessel wall measurements using an arc-length (AL) scaling approach adjusted the geometric variability of carotid arteries and has allowed for the comparisons of VWT distributions in longitudinal ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4966702
更新日期:2016-12-01 00:00:00
abstract::In patients with lymphoma, identification and quantification of the tumor extent on serial CT examinations is critical for assessing tumor response to therapy. In this paper, we present a computer method to automatically match and segment lymphomas in follow-up CT images. The method requires that target lymph nodes in...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2404617
更新日期:2007-01-01 00:00:00
abstract::In the case of non-small cell lung cancer, doses typically prescribed (60-66 Gy) are not sufficient to ensure a satisfactory tumor control probability. Dose escalation needs to be realized, but dose to organs at risk (OARs) must be kept under widely accepted clinical thresholds. Also, lung functionality is not homogen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965976
更新日期:2008-07-01 00:00:00
abstract:PURPOSE:A critical step in adaptive radiotherapy (ART) workflow is deformably registering the simulation CT with the daily or weekly volumetric imaging. Quantifying the deformable image registration accuracy under these circumstances is a complex task due to the lack of known ground-truth landmark correspondences betwe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12321
更新日期:2017-08-01 00:00:00
abstract:PURPOSE:To investigate the critical structure sparing achievable by biological optimization for modulated volumetric arc (VMAT) of head and neck (H&N) cancer. METHODS:Ten H&N VMAT patients who were originally planned and treated with simultaneous integrated boost technique using dose-volume based optimization, were se...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735671
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To develop a novel system for patient-specific combined optimization of couch, collimator, and gantry angles for use in volumetric modulated arc therapy (VMAT) treatment planning. The system was designed to produce highly compact dose distributions by extensively sampling the 4π space. Automated fixed couch tra...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13887
更新日期:2020-02-01 00:00:00
abstract:PURPOSE:Compton camera imaging (CCI) systems are currently under investigation for radiotherapy dose reconstruction and verification. The ability of such a system to provide real-time images during dose delivery will be limited by the computational speed of the image reconstruction algorithm. In this work, the authors ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3519873
更新日期:2011-01-01 00:00:00
abstract::A commercially available open MRI unit is under routine use for radiation therapy simulation. The effects of a gradient distortion correction (GDC) program used to post process the images were assessed by comparison with the known geometry of a phantom. The GDC reduced the magnitude of the distortions at the periphery...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1513991
更新日期:2002-11-01 00:00:00
abstract::Two new liquid ionization chamber (LIC) designs, consisting of cylindrical and plane-parallel configurations, are presented. They are designed to be suitable for high-precision measurements of absorbed dose-to-water at dose rates and photon energies typical for LDR intermediate photon energy brachytherapy sources. The...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598268
更新日期:1998-06-01 00:00:00
abstract:PURPOSE:The aim of this study is to understand the characteristics of secondary electrons generated from the interaction of gold nanoparticles (GNPs) with x-rays as a function of nanoparticle size and beam energy and thereby further the understanding of GNP-enhanced radiotherapy. METHODS:The effective range, deflectio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3539623
更新日期:2011-02-01 00:00:00
abstract:PURPOSE:Cone-beam computed tomography (CBCT) is an increasingly utilized imaging modality for the diagnosis and treatment planning of the patients with craniomaxillofacial (CMF) deformities. Accurate segmentation of CBCT image is an essential step to generate three-dimensional (3D) models for the diagnosis and treatmen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4868455
更新日期:2014-04-01 00:00:00
abstract::In this work, we present a calcification-detection scheme that automatically localizes calcifications in a previously detected cluster in order to generate the input for a cluster-classification scheme developed in the past. The calcification-detection scheme makes use of three pieces of a priori information: the loca...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1559884
更新日期:2003-05-01 00:00:00
abstract:PURPOSE:The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD). METHODS:Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and exp...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4813906
更新日期:2013-08-01 00:00:00
abstract:PURPOSE:To investigate image-registration errors when using fiducial markers with a manual method and the point-based rigid-body registration (PRBR) algorithm in accelerated partial breast irradiation (APBI) patients, with accompanying fiducial deviations. METHODS:Twenty-two consecutive patients were enrolled in a pro...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1118/1.4915534
更新日期:2015-04-01 00:00:00
abstract:PURPOSE:To assess and compare the dosimetric impact of dynamic multileaf collimator (DMLC) tracking and gating as motion correction strategies to account for intrafraction motion during conventionally fractionated prostate radiotherapy. METHODS:A dose reconstruction method was used to retrospectively assess the dose d...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4892605
更新日期:2014-09-01 00:00:00